potentialpaper

Reference-Aware Fairness Auditing: Separating Label Artifacts from Model Bias

Update ICLR 2027 submission WzTL9FaGqJ: 1 note

@openreview[bot] · 2026-11-26 02:28 UTC · 5b0b30b0009f ·

Evidence

reviews/openreview/wztl9fagqj/notes/g3736mhdvd.json modified

+++ b/reviews/openreview/wztl9fagqj/notes/g3736mhdvd.json
@@ -13,12 +13,19 @@
"critical_strengths": "1. RAFA adjusts the evaluation only that does not require retraining. This makes the method easy to implement.\n2. This paper clearly articulates the conditions under which the method is effective and openly explains the scenarios in which noise estimation fails (CheXpert, LIDC, crowd counting), as well as the sensitivity of the results to noise estimation errors (Appendix C). This enhances the reliability of RAFA for reuse.",
"critical_weaknesses": "W1: This paper discusses the more intuitive aspects of RAFA (Equations 3–6), but the most critical part—noise estimation—is only specifically mentioned in Section 4. Furthermore, the controlled experiments only validated the subtraction step, which corresponds to “known to the auditor here: this tests the adjustment itself, not the estimation of label noise” (L204–206). Experiments on real-world data succeeded only once (fetal weight); CheXpert, LIDC (Section 5, Appendix E), and crowd counting (Appendix F) all failed to produce accurate estimates, suggesting that the robustness and validity of RAFA require further investigation.\n\nW2. The paper’s main results are based on assumptions that cannot be externally verified. Specifically, in hypothesis R2, the two predictors used in Equation (7) are both based on the same ultrasound examination. The common error between them leads to an overestimation of the noise estimate. The paper’s own crowd counting experiment indicates that such common errors may be the dominant factor (accounting for 73–87% of the error variance). R3. Label errors caused by backprojection may also be correlated with model error. Appendix C only altered the magnitude of the noise and did not change this correlation. However, within each stratum, the estimated noise values were as large as the adjusted model error (Table 2); therefore, the figure of 73% may lack robustness.\n\nMinor issues.\n\n- This paper contrasts RAFA with methods that operate by “correcting labels or modifying training” (L048–049). This is inconsistent with the evaluation-related studies cited in the text (Fogliato et al., 2020; Adebayo et al., 2023). The text does not discuss the literature on imperfect reference standards.\n- The abstract states that the paper explains how to validate these conditions in practice, but the main text asserts that R2 and R3 cannot be tested using audit data (L161–162).\n- Only continuous errors are covered; FNR or AUC are not addressed.\n- The term “Reference” in the method name is not defined.",
"questions_for_authors": "Q1: Is it possible for both predictors in the R2 hypothesis to be wrong at the same time?\n\nFor scans performed one or two days before delivery, the label noise should be close to 0. What is Cov(e_DL, e_Hadlock) for this subset? If it is close to σ0² (σ0 = 0.351, L353), it would suggest that the estimated “noise” actually absorbs the common error of the two predictors.\n\nIs it possible to add a third predictor for double-check? After controlling for gestational week, will the noise curve (Eq. 8) change?\n\nQ2: In the R3 hypothesis, within each stratum, assume the correlation coefficient between model error and label error is ρ. How does the 73% figure vary with ρ? At what value of ρ does the statement “unequal label noise explains most of the measured disparity” no longer hold?\n\nQ3: RAFA only requires second-order statistics for each group. Please disclose the number of examinations in each STD stratum, as well as Var(e_DL), Var(e_Hadlock), and Cov(e_DL, e_Hadlock). This would allow Table 2 and Eq. 8 to be reproduced without disclosing the private dataset. We also recommend adding a table describing the data characteristics: how out-of-sample predictions are made, the reference baseline for z-scores, which version of Hadlock is used, and exclusion criteria.\n\nQ4: Aside from the “failure signal,” how can auditors verify that R1–R3 hold true so they can confidently use the adjusted figures?\n\nHow does this approach differ from the sensitivity analysis in Fogliato et al. (2020) and the correction methods for “imperfect reference standards” in medicine? Is it possible to conduct an experimental comparison?\n\nQ5:\n- What does σ0 = 0.351 on Line 353 represent? When STD approaches 0, there should be almost no projection error.\n- The term “Reference” used in the method title \"R\"AFA is not defined.\n- Why is the 73% point estimate noticeably higher than the bootstrap median of 64%?\n- Since s(g) is the standard deviation of the error after removing the mean, a certain group being systematically overestimated or underestimated is not within the scope of this analysis. How should this be interpreted? (The paper assumes E[ε|g] = 0.)\n- Ethical review and data usage terms for fetal data (there is no ethics statement in the full text).\n\nQ6: Apply this to demographic groups to see if it changes the conclusions regarding fairness; extend this to classification metrics (FNR, AUC).",
"flag_for_ethics_review": "No",
- "rating": 2,
+ "rating": 1,
"confidence": 2
},
"createdAt": "2026-10-22T03:51:15.063Z",
- "modifiedAt": "2026-11-23T13:23:20.865Z",
+ "modifiedAt": "2026-11-26T01:57:15.501Z",
"url": "https://openreview.net/forum?id=WzTL9FaGqJ&noteId=g3736MhDVd",
- "license": "CC-BY-4.0"
+ "license": "CC-BY-4.0",
+ "scoreChanges": [
+ {
+ "field": "rating",
+ "from": 2,
+ "at": "2026-11-26T02:28:43.603Z"
+ }
+ ]
}