potentialpaper

One-Step Curvature Probes Miss the Fitting Operator: Retained Capacity and Terminal Null-Space Correction for Continual Learning

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:02 UTC · 723824cf6165 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "hg3cESNAzn"
- }
- ],
- "title": "One-Step Curvature Probes Miss the Fitting Operator: Retained Capacity and Terminal Null-Space Correction for Continual Learning",
- "authors": [],
- "abstract": "A one-step curvature probe evaluates an initial direction, whereas continual\nlearners are judged after reaching comparable new-task fit. These quantities\nneed not agree. In an overparameterized linearization, projected gradient\ndescent converges to\n$\\Delta_P=PJ^\\top(JPJ^\\top)^{-1}r$, and its squared-displacement inflation is\nexactly the reciprocal of the direction-specific retained fitting capacity\n$c_P(r)=\\lVert J^+r\\rVert^2/\n\\lVert PJ^\\top(JPJ^\\top)^{-1}r\\rVert^2$. More generally, the\nterminal old-task quadratic ratio factorizes as\n$1/[c_P(r)G_{\\rm end}(P,r)]$, where $G_{\\rm end}$ compares curvature along the\nnormalized endpoint directions. In the rank-one case, $G_{\\rm end}$ equals the one-step probe gain; for multiple outputs, the two gains need not agree. The terminal quadratic further\ndecomposes into a common curvature-optimal fitting floor and an\nalgorithm-dependent null-space excess. This geometry identifies the\nvariable omitted by a matched-norm probe and yields terminal null-space\ncorrection, a post-hoc operation that preserves linearized new-task\noutputs on its Jacobian batch. In separate controlled checks, the local quadratic has slope $1.0012$\n($R^2=0.9997$); projection reduces the matched-norm quadratic by\n$4.03\\times$ while terminal forgetting changes by only\n$5.34\\times10^{-4}$. Across five common-threshold configurations,\nprojection produces the larger signed old-task loss change in $73/99$\nmatched pairs. In the eligible-subset probe study, median gain ranges\nfrom about $3\\times$ to $>1000\\times$ (eight pairs at the upper end).\nThe common-threshold rank sweep shows median retained fitting capacity\nfalling from $0.88$ to $0.19$. A fixed-rank comparison separates terminal\nforgetting when probe gain is approximately matched, whereas the\ncapacity-matched contrast remains compatible with effects of either sign. On\nPermuted MNIST and Split CIFAR-100, terminal correction decreases signed\nold-task loss in $166/180$ method--dataset--seed pairs under the all-seed\nintention-to-correct analysis. Because acceptance and outcome reporting use\nthe same held-out split, this result is descriptive and test-conditioned.\nTogether, the results replace gain-only interpretation with a matched-fit\naccount: in the fixed-Jacobian quadratic model, terminal cost depends jointly\non retained fitting capacity, endpoint-direction curvature, and the\nnull-space component selected by optimization.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "86d466be-8d47-4012-92bf-c8018e52f68d"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "One-Step Curvature Probes Miss the Fitting Operator: Retained Capacity and Terminal Null-Space Correction for Continual Learning",
+ "authors": [],
+ "abstract": "A one-step curvature probe evaluates an initial direction, whereas continual\nlearners are judged after reaching comparable new-task fit. These quantities\nneed not agree. In an overparameterized linearization, projected gradient\ndescent converges to\n$\\Delta_P=PJ^\\top(JPJ^\\top)^{-1}r$, and its squared-displacement inflation is\nexactly the reciprocal of the direction-specific retained fitting capacity\n$c_P(r)=\\lVert J^+r\\rVert^2/\n\\lVert PJ^\\top(JPJ^\\top)^{-1}r\\rVert^2$. More generally, the\nterminal old-task quadratic ratio factorizes as\n$1/[c_P(r)G_{\\rm end}(P,r)]$, where $G_{\\rm end}$ compares curvature along the\nnormalized endpoint directions. In the rank-one case, $G_{\\rm end}$ equals the one-step probe gain; for multiple outputs, the two gains need not agree. The terminal quadratic further\ndecomposes into a common curvature-optimal fitting floor and an\nalgorithm-dependent null-space excess. This geometry identifies the\nvariable omitted by a matched-norm probe and yields terminal null-space\ncorrection, a post-hoc operation that preserves linearized new-task\noutputs on its Jacobian batch. In separate controlled checks, the local quadratic has slope $1.0012$\n($R^2=0.9997$); projection reduces the matched-norm quadratic by\n$4.03\\times$ while terminal forgetting changes by only\n$5.34\\times10^{-4}$. Across five common-threshold configurations,\nprojection produces the larger signed old-task loss change in $73/99$\nmatched pairs. In the eligible-subset probe study, median gain ranges\nfrom about $3\\times$ to $>1000\\times$ (eight pairs at the upper end).\nThe common-threshold rank sweep shows median retained fitting capacity\nfalling from $0.88$ to $0.19$. A fixed-rank comparison separates terminal\nforgetting when probe gain is approximately matched, whereas the\ncapacity-matched contrast remains compatible with effects of either sign. On\nPermuted MNIST and Split CIFAR-100, terminal correction decreases signed\nold-task loss in $166/180$ method--dataset--seed pairs under the all-seed\nintention-to-correct analysis. Because acceptance and outcome reporting use\nthe same held-out split, this result is descriptive and test-conditioned.\nTogether, the results replace gain-only interpretation with a matched-fit\naccount: in the fixed-Jacobian quadratic model, terminal cost depends jointly\non retained fitting capacity, endpoint-direction curvature, and the\nnull-space component selected by optimization.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}