potentialpaper

LAnoDet: Self-Supervised Lung Anomaly Detection with Transformer-Based Diffusion Models

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:02 UTC · dcbbe07f0c5b ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "dHFzmpoUzS"
- }
- ],
- "title": "LAnoDet: Self-Supervised Lung Anomaly Detection with Transformer-Based Diffusion Models",
- "authors": [],
- "abstract": "Detecting anomalies in chest X-rays is central to the timely diagnosis of lung disease, but labelled abnormal images are scarce and the abnormalities are often subtle. Reconstruction-based generative models trained only on normal images offer a label-free alternative in which an anomaly is revealed by the error between an image and its reconstruction. We identify three limitations of current diffusion-based detectors: convolutional U-Net backbones capture local texture but not the long-range structure of the thorax, whereas global self-attention costs quadratic time in the number of patches; the noise-prediction objective and stochastic sampler inject sampling variance into the very residual that serves as the anomaly score; and a fixed timestep code gives the network no control over how diffusion time is represented. We propose LAnoDet, in which each component answers one of the above limitations: (1) a time-embedded Transformer encoder–decoder whose attention is factorised into row and column multi-head attention (RC-MHA), reducing the cost of attention from O(N^2d) to O(N^1.5d) while preserving structured spatial dependencies; (2) a deterministic reverse process that reconstructs the clean image at every timestep with a mean-squared-error objective instead of predicting and subtracting noise; and (3) a learnable timestep embedding added to the patch and positional embeddings. Trained only on normal chest X-rays from COVIDx CXR-4, LAnoDet reaches 96.2% accuracy, 97.3% sensitivity, 96.9% F1 score and 96.51% AUC on COVID-19 detection and transfers without retraining to a pneumonia dataset with 96.78% accuracy, 98.34% sensitivity, 97.71% F1 score and 97.16% AUC, matching or exceeding supervised classifiers reported on these datasets. A sixteen-variant ablation shows that row–column attention, skip connections and the learnable time embedding each contribute, the full model exceeding its global self-attention counterpart by 4.17 AUC points.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "6071f2d8-b0cb-429f-ba74-82e30f88d492"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "LAnoDet: Self-Supervised Lung Anomaly Detection with Transformer-Based Diffusion Models",
+ "authors": [],
+ "abstract": "Detecting anomalies in chest X-rays is central to the timely diagnosis of lung disease, but labelled abnormal images are scarce and the abnormalities are often subtle. Reconstruction-based generative models trained only on normal images offer a label-free alternative in which an anomaly is revealed by the error between an image and its reconstruction. We identify three limitations of current diffusion-based detectors: convolutional U-Net backbones capture local texture but not the long-range structure of the thorax, whereas global self-attention costs quadratic time in the number of patches; the noise-prediction objective and stochastic sampler inject sampling variance into the very residual that serves as the anomaly score; and a fixed timestep code gives the network no control over how diffusion time is represented. We propose LAnoDet, in which each component answers one of the above limitations: (1) a time-embedded Transformer encoder–decoder whose attention is factorised into row and column multi-head attention (RC-MHA), reducing the cost of attention from O(N^2d) to O(N^1.5d) while preserving structured spatial dependencies; (2) a deterministic reverse process that reconstructs the clean image at every timestep with a mean-squared-error objective instead of predicting and subtracting noise; and (3) a learnable timestep embedding added to the patch and positional embeddings. Trained only on normal chest X-rays from COVIDx CXR-4, LAnoDet reaches 96.2% accuracy, 97.3% sensitivity, 96.9% F1 score and 96.51% AUC on COVID-19 detection and transfers without retraining to a pneumonia dataset with 96.78% accuracy, 98.34% sensitivity, 97.71% F1 score and 97.16% AUC, matching or exceeding supervised classifiers reported on these datasets. A sixteen-variant ablation shows that row–column attention, skip connections and the learnable time embedding each contribute, the full model exceeding its global self-attention counterpart by 4.17 AUC points.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}