potentialpaper

Rollout-Level Calibration for Failure Monitoring in Generative Robot Policies

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:06 UTC · e13c116c5ea0 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "rzLZ8Frrte"
- }
- ],
- "title": "Rollout-Level Calibration for Failure Monitoring in Generative Robot Policies",
- "authors": [],
- "abstract": "Failure monitors for generative robot policies must raise timely alarms while limiting false positives on executions that would otherwise\nsucceed. We introduce RoLCA (Rollout-Level Conformal Alerting), a modular layer that aggregates progress-matched score evidence over\ntime and across channels, then split-conformally calibrates its maximum over eligible monitoring times using successful rollouts only. Under exchangeability of successful rollouts, RoLCA provides finite-sample rollout-level false-positive control for causal scoring, aggregation, fusion, and monitoring rules fixed independently of threshold calibration. The guarantee is marginal over the calibration\ndraw and the next successful rollout, without requiring within-rollout independence. Across 30,502 rollouts in six task--backbone cells,\ncalibrated monitors operate near the nominal false-positive rate in two sealed confirmations, but detection gains depend on the monitoring\nconvention. On the second confirmation, a post-hoc comparison yields a 7.6-percentage-point paired recall gain over matched running-average OR under fixed-horizon monitoring; this advantage is not established after stop-at-success recalibration. Fusion improves early recall over a rollout-trained single channel but does not consistently outperform execution consistency alone. A clock-only baseline detects all timeout failures in this population under stop-at-success evaluation, motivating assessment of early warning beyond eventual coverage.\nThese results separate false-alarm validity from detection power and underscore the need for explicit monitoring intervals, matched\ncomparators, and timing baselines.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "cee09603-3b52-4eb3-bc4d-be33e4176801"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Rollout-Level Calibration for Failure Monitoring in Generative Robot Policies",
+ "authors": [],
+ "abstract": "Failure monitors for generative robot policies must raise timely alarms while limiting false positives on executions that would otherwise\nsucceed. We introduce RoLCA (Rollout-Level Conformal Alerting), a modular layer that aggregates progress-matched score evidence over\ntime and across channels, then split-conformally calibrates its maximum over eligible monitoring times using successful rollouts only. Under exchangeability of successful rollouts, RoLCA provides finite-sample rollout-level false-positive control for causal scoring, aggregation, fusion, and monitoring rules fixed independently of threshold calibration. The guarantee is marginal over the calibration\ndraw and the next successful rollout, without requiring within-rollout independence. Across 30,502 rollouts in six task--backbone cells,\ncalibrated monitors operate near the nominal false-positive rate in two sealed confirmations, but detection gains depend on the monitoring\nconvention. On the second confirmation, a post-hoc comparison yields a 7.6-percentage-point paired recall gain over matched running-average OR under fixed-horizon monitoring; this advantage is not established after stop-at-success recalibration. Fusion improves early recall over a rollout-trained single channel but does not consistently outperform execution consistency alone. A clock-only baseline detects all timeout failures in this population under stop-at-success evaluation, motivating assessment of early warning beyond eventual coverage.\nThese results separate false-alarm validity from detection power and underscore the need for explicit monitoring intervals, matched\ncomparators, and timing baselines.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}