potentialpaper

EviFlow: Structured-Noise Flow Matching for Multi-Rater Segmentation

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:06 UTC · 354ba6dcbaa8 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "37XGtiYROj"
- }
- ],
- "title": "EviFlow: Structured-Noise Flow Matching for Multi-Rater Segmentation",
- "authors": [],
- "abstract": "Multi-rater segmentation requires coherent alternative delineations, not merely variable pixelwise predictions. We introduce EviFlow, a conditional flow-matching sampler driven by spatially coherent base noise, together with a distribution-aware evaluation protocol. We establish that, for binary masks on a fixed finite grid, the generalized energy distance (GED) with ground distance is exactly the squared maximum mean discrepancy under the Jaccard kernel. Its strict positive definiteness makes this GED a strictly proper population divergence; the variant with ground distance is strictly proper as well. We distinguish these population guarantees from U- and V-statistic estimation and complement GED with Hungarian-matched IoU (HM-IoU), dispersion, and simple stochastic references. Replacing independent base noise with normalized blurred Gaussian noise yields coherent whole-object alternatives: on LIDC-IDRI with four raters and nine seeds, energy GED decreases from 0.178±0.014 to 0.092±0.022 and HM-IoU rises from 0.361±0.027 to 0.489±0.029. Baseline tuning changes the comparison substantially: a validation-tuned Probabilistic U-Net is not significantly different on energy GED and is better on Jaccard MMD and HM-IoU, whereas its untuned counterpart is the weakest learned stochastic baseline on LIDC GED. On LNDb, EviFlow achieves lower energy GED than the tuned Probabilistic U-Net; additional benchmarks reveal dataset-dependent trade-offs. These findings show the value of structured generative noise and establish a practical case for reporting distributional fit, sample fidelity, dispersion, and baseline tuning together.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "a71be199-8b98-43ae-8409-54a806bd3c4e"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "EviFlow: Structured-Noise Flow Matching for Multi-Rater Segmentation",
+ "authors": [],
+ "abstract": "Multi-rater segmentation requires coherent alternative delineations, not merely variable pixelwise predictions. We introduce EviFlow, a conditional flow-matching sampler driven by spatially coherent base noise, together with a distribution-aware evaluation protocol. We establish that, for binary masks on a fixed finite grid, the generalized energy distance (GED) with ground distance is exactly the squared maximum mean discrepancy under the Jaccard kernel. Its strict positive definiteness makes this GED a strictly proper population divergence; the variant with ground distance is strictly proper as well. We distinguish these population guarantees from U- and V-statistic estimation and complement GED with Hungarian-matched IoU (HM-IoU), dispersion, and simple stochastic references. Replacing independent base noise with normalized blurred Gaussian noise yields coherent whole-object alternatives: on LIDC-IDRI with four raters and nine seeds, energy GED decreases from 0.178±0.014 to 0.092±0.022 and HM-IoU rises from 0.361±0.027 to 0.489±0.029. Baseline tuning changes the comparison substantially: a validation-tuned Probabilistic U-Net is not significantly different on energy GED and is better on Jaccard MMD and HM-IoU, whereas its untuned counterpart is the weakest learned stochastic baseline on LIDC GED. On LNDb, EviFlow achieves lower energy GED than the tuned Probabilistic U-Net; additional benchmarks reveal dataset-dependent trade-offs. These findings show the value of structured generative noise and establish a practical case for reporting distributional fit, sample fidelity, dispersion, and baseline tuning together.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}