POST-TRAIN THE MAP YOU SOLVE: DEPLOYMENT-ALIGNED SPECIALIZATION FOR FEW-STEP FLOW SAMPLING
Import ICLR 2027 submission 3U3vPwgTAR: 19 notes
@openreview[bot] · 2026-11-22 20:19 UTC · 49a43a3bb8aa
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,19 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "3U3vPwgTAR"+ }+ ],+ "title": "POST-TRAIN THE MAP YOU SOLVE: DEPLOYMENT-ALIGNED SPECIALIZATION FOR FEW-STEP FLOW SAMPLING",+ "authors": [],+ "abstract": "Flow matching trains a continuous velocity field, but few-step sampling deploys a solver- and budget-specific finite map. We post-train that exact map by differentiating a terminal distribution objective through the deployed solver. A shared field–clock repair is followed by tiny solver-specific residual clocks, activated only when held-out target alignment predicts a gain. At 12 field evaluations on a public conditional-flow receiver trained with C²OT (conditional optimal transport), shared repair lowers mean CleanFID10k from 46.824 to 7.704; a 120-parameter residual package reaches 7.334 and is favorable in 10/10 retrainings for each active solver. On the official Scalable Interpolant Transformer (SiT) checkpoint, a frozen finite-stage operator improves Heun and fourth-order Runge–Kutta in every paired 50,000-sample ImageNet Fréchet Inception Distance (FID) evaluation and transfers without target-budget fitting to 8 and 24 field evaluations. B-series analysis and measured error orders trace these gains to tableau-dependent finite-step error. The alignment rule also predicts held-out directions on a second architecture and non-image receivers, while an alternative objective and independent feature representations corroborate the effect. The method keeps one field across solvers and adds no field evaluations; held-out evidence determines which residual clocks are stored.",+ "year": 2027,+ "venue": "ICLR 2027 (under review)",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/3u3vpwgtar/forms.json added
+++ b/reviews/openreview/3u3vpwgtar/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/02hlxdmqwa.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/02hlxdmqwa.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "02HlXDmqwA",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer GXNN",+ "content": {+ "paper_summary": "This paper proposes a deployment aligned post-training method that repairs the exact few step solver budget sampling map of flow models via shared field clock adaptation and selective residual clocks, improving low NFE generation without adding field evaluations.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "1.The paper is well-structured and presents a comprehensive methodological framework.\n2.Extensive theoretical derivations and analyses support the proposed method.",+ "critical_weaknesses": "1. The full two-stage pipeline is mainly validated on CIFAR-10 receivers, while ImageNet SiT experiments only evaluate a frozen finite-stage temporal operator.\n2. The experiments mainly rely on internal controls and lack sufficient matched comparisons against representative few step sampling and solver optimization baselines.\n3. The introduction is overly compressed and fails to clearly convey the core motivation and intuition.\n4. The first figure in the appendix, which presents qualitative sample comparisons under fixed noises, is blurry and difficult to interpret.",+ "questions_for_authors": "See the Weakness.",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 2+ },+ "createdAt": "2026-10-22T09:38:55.920Z",+ "modifiedAt": "2026-11-06T12:34:59.036Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=02HlXDmqwA",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/1snocdzmbm.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/1snocdzmbm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "1sNOCdzMBm",+ "replyTo": "jkZ6dF5vu4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair NgE7",+ "content": {+ "comment": "Dear Reviewer,\n\nThe discussion deadline is approaching. Please review the authors’ responses and clearly indicate whether they adequately address your concerns. Kindly update your score if appropriate.\n\nBest regards,\n\nAC"+ },+ "createdAt": "2026-11-19T02:16:24.984Z",+ "modifiedAt": "2026-11-19T02:16:24.984Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=1sNOCdzMBm",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/312kd8fhvn.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/312kd8fhvn.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "312kd8fhvn",+ "replyTo": "7ifpqcjYrh",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer,\n\nThanks for the response.\n\nOur motivation is that good continuous-time dynamics do not necessarily yield good few-step samples, because generation quality also depends on the deployed solver and evaluation budget. We therefore adapt the finite-step sampling process while retaining one shared velocity field. Stage I provides the main improvement through shared field-and-clock adaptation; Stage II offers optional solver-specific refinement, with an exact shared-clock fallback.\n\nBesides, we have provided direct answers to your initial questions and implemented the corresponding revisions. Please feel free to raise any remaining concerns, so that we can further respond and revise our work accordingly.\n\nCould you please point to the specific statement or logical step that remains unclear, or explain which premise you find unconvincing? This would help us address your concern directly.\n\nBest,\n\nThe authors."+ },+ "createdAt": "2026-11-19T11:56:41.494Z",+ "modifiedAt": "2026-11-19T12:04:22.250Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=312kd8fhvn",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/6o0jr2t6fz.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/6o0jr2t6fz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6o0JR2T6Fz",+ "replyTo": "02HlXDmqwA",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Comment 1. Full two-stage validation on ImageNet SiT\n\n> **Question.** The ImageNet SiT experiments validate only the frozen temporal operator. The full two-stage procedure is mainly tested on CIFAR-10 receivers, so the current evidence does not establish transfer of the full method to ImageNet.\n\n**Response 1**\n\nThank you for identifying this gap. We added full experiments on SiT-XL/2 ImageNet-256.\n\nStage I updates 28,222,880 prespecified field parameters and 8 shared-clock logits for 192 updates. From the same Stage-I model, we then construct Continued Shared, Solver-specific Residual, and Shared-capacity Control.\n\nThe residual and shared-capacity controls each have 14 extra clock degrees of freedom, with different function families.\n\nAt NFE12 and CFG1.5, every condition uses 50,000 images from the same paired generation stream. Each cell gives ADM-FID50k / DINOv2 FD / CLIP-FID.\n\n| Method | Heun | RK4 |\n| ------------------- | -------------------------------- | -------------------------------- |\n| Original Uniform | 5.660788 / 233.418433 / 4.751316 | 3.626882 / 195.753637 / 3.665255 |\n| Frozen Finite-stage | 5.012748 / 223.237866 / 4.415269 | 3.443654 / 192.274793 / 3.551778 |\n| Shared Adaptation | 3.993210 / 197.755778 / 3.990408 | 2.853464 / 168.864649 / 3.274840 |\n| Continued Shared | 4.009560 / 198.105315 / 3.998850 | 2.866288 / 169.146239 / 3.280756 |\n| Raw Residual | 4.000501 / 198.031288 / 3.993177 | 2.855850 / 168.951369 / 3.275201 |\n| Shared Capacity | 3.995885 / 197.673120 / 3.991805 | 2.858884 / 168.908310 / 3.278103 |\n\nShared Adaptation substantially improves all three distances for both solvers. Raw Residual Candidates give no further improvement.\n\nThe experiment supports two conclusions.\n\n1. **Stage-I field-and-clock adaptation improves low-NFE generation on ImageNet SiT.**\n2. Stage-II residual refinement does not always add a gain for every architecture and solver.\n\nWe will present the original frozen-operator experiments and the new full field-adapted experiments separately.\n### Comment 2. Direct comparisons with few-step sampling and solver optimization\n\n> **Question.** Direct comparisons with representative few-step sampling and solver optimization methods are missing.\n\n**Response 2**\n\nThank you for pointing out this gap. We added ImageNet-256 comparisons covering training-free samplers, optimized timestep schedules, and learned specialized solvers. The implementation is available in the [anonymous code repository](https://anonymous.4open.science/r/few-step-sampler-review-11B8/).\n\nWe also accounted for acquisition and adaptation costs consistently to compare methods at the same NFE and similar adaptation budgets. All main quality comparisons use NFE12 and the same initial pretrained checkpoint.\n\n#### A. ImageNet-256 generation quality\n\nThe comparison includes the following methods.\n\n- **Native sampler.** Uniform Native Midpoint.\n- **Optimized schedule.** AYS MC128 Resource Port.\n- **Training-free solver.** STORK Order-2.\n- **Solver with clock.** STORK + Frozen Clock.\n- **Learned solver.** Bespoke RK2 Full-port and Resource-cut.\n- **Specialized few-step method.** BézierFlow SiT Compatibility Port.\n- **Ours.** Shared Adaptation with Heun and RK4.\n\nEach condition uses 50,000 generated images. Lower is better for ADM-FID50k, DINOv2 FD, and CLIP-FID.\n\n| Method | ADM-FID50k ↓ | DINOv2 FD ↓ | CLIP-FID ↓ |\n| --------------------------------- | -----------: | -------------: | -----------: |\n| BézierFlow SiT Compatibility Port | 3.184069 | 182.942166 | 3.379921 |\n| STORK Order-2 | 3.131723 | 182.870190 | 3.293903 |\n| STORK + Frozen Clock | 3.087859 | 181.441707 | 3.272954 |\n| Bespoke RK2 Full-port | 2.884906 | 179.971207 | **3.155823** |\n| Bespoke RK2 Resource-cut | 2.911586 | 181.370197 | 3.167371 |\n| Ours: Shared Adaptation (Heun) | 3.993210 | 197.755778 | 3.990408 |\n| **Ours: Shared Adaptation (RK4)** | **2.853464** | **168.864649** | 3.274840 |\n\nShared RK4 is competitive on ImageNet-256.\n\n1. **Against BézierFlow.** ADM-FID50k decreases from 3.184069 to 2.853464, DINOv2 FD from 182.942166 to 168.864649, and CLIP-FID from 3.379921 to 3.274840. All three distances are lower in this SiT compatibility-port comparison.\n2. **Against Bespoke.** Shared RK4 scores 2.853464 and 168.864649 on ADM-FID50k and DINOv2 FD. These are lower than Full-port's 2.884906 and 179.971207 and Resource-cut's 2.911586 and 181.370197. Bespoke has better CLIP-FID.\n3. **Against STORK.** Shared RK4 has lower ADM-FID50k and DINOv2 FD than both STORK configurations, with slightly higher CLIP-FID.\n\nThese results support competitive performance across multiple metrics in this low-NFE ImageNet deployment setting."+ },+ "createdAt": "2026-11-13T16:26:05.659Z",+ "modifiedAt": "2026-11-13T16:26:05.659Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=6o0JR2T6Fz",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/7ifpqcjyrh.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/7ifpqcjyrh.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "7ifpqcjYrh",+ "replyTo": "Lwwbo4pon0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer GXNN",+ "content": {+ "comment": "Considering the confusion regarding motivation, I maintain my original score."+ },+ "createdAt": "2026-11-19T11:23:35.460Z",+ "modifiedAt": "2026-11-19T11:23:35.460Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=7ifpqcjYrh",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/cgyna8jvsa.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/cgyna8jvsa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "cGyNa8JVSa",+ "replyTo": "UkNHSvsD8y",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "#### B. FID50k across ten independent refinement runs\n\nWe fixed the original Stage-I model, ran residual refinement independently ten times, and evaluated each refinement seed on three independent generation streams.\n\n| Solver | Mean FID reduction ± SD across refinement seeds | Seed × stream conditions improving all three distances |\n| ------ | ----------------------------------------------- | ------------------------------------------------------ |\n| RK3 | **0.958958 ± 0.071951** | **30/30** |\n| RK4 | **0.137326 ± 0.020552** | **30/30** |\n\nFID reduction is shared FID minus residual-package FID, so a positive value means improvement.\n\nFor each refinement seed, we first averaged the FID differences across its three streams. We then calculated the sample standard deviation across the ten seed means.\n\nBoth RK3 and RK4 improve **all three distances in all 30 seed × stream conditions**. This provides FID-level evidence for repeatability across refinement runs and generation streams on the fixed Stage-I receiver.\n\n#### C. Three sources of variability\n\n**(a) Stage-I adaptation variability**\n\nWith the package and refinement seed fixed, both solvers improve FID50k on all three Stage-I models. All three distances improve on every stream. Two models were excluded from capacity selection, providing independent validation across Stage-I adaptations.\n\n**(b) Refinement-seed variability**\n\nWith the original receiver fixed, ten independent refinement runs each improve all three metrics on three generation streams. Each solver achieves 30/30 improvements. The mean FID reduction and between-seed standard deviation quantify refinement-seed variability.\n\n**(c) Generation-stream variability**\n\nBoth experiments use three independent generation streams. The observed improvements therefore extend beyond the earlier fixed-stream evaluation.\n\n#### D. Revised interpretation of the original 10/10 result\n\nWe will revise Supplementary Table 46 and the related text. The original 10/10 result refers only to ten refinement-seed proxy improvements on a fixed Stage-I receiver and a fixed 2,048-sample evaluation stream.\n\nThe new experiments add the following evidence.\n\n- FID50k confirmation on three independent Stage-I models.\n- FID50k confirmation across ten independent refinement runs.\n- Repeated evaluation on three independent generation streams.\n- Improvements in FID, DINOv2 FD, and CLIP-FID for RK3 and RK4 in every corresponding condition.\n\nWe will report the original proxy result alongside the new model, refinement-seed, and generation-stream evaluations. These provide formal FID-level evidence of the added gain for RK3 and RK4.\n### Comment 3. Metric labels in the SiT cross-budget experiments\n\n> **Question.** Were the SiT cross-budget results incorrectly described as FID improvements?\n>\n> The NFE8 and NFE24 values in Section 5.2 match the projected Fréchet risk differences in Supplementary Table 52. Please clarify the metrics and provide corresponding ADM-FID50k results.\n\n**Response 3**\n\nThank you for identifying this reporting error. **The projected Fréchet risk differences were incorrectly labeled as FID improvements.** We corrected this in the updated PDF.\n\nThe original values are projected risk differences.\n\n| Solver | NFE8 | NFE24 |\n| ------ | ------ | ------ |\n| Heun | 0.3707 | 0.0165 |\n| RK4 | 0.0311 | 0.0054 |\n\nThey evaluate the proxy training objective. We also completed ADM-FID50k, DINOv2 FD, and CLIP-FID evaluations for 16 cross-budget conditions.\n\n#### A. Heun\n\n| NFE | Branch | ADM-FID50k ↓ | DINOv2 FD ↓ | CLIP-FID ↓ |\n| ---- | ------------ | ------------: | -------------: | -----------: |\n| 8 | Uniform | 14.690812 | 357.759507 | 8.502115 |\n| 8 | Grid | 14.436746 | 358.101928 | 8.400083 |\n| 8 | Continuous | 14.271673 | 350.669697 | 8.387267 |\n| 8 | Finite-stage | **11.947994** | **327.990600** | **7.455960** |\n| 24 | Uniform | 2.620245 | 169.618430 | 3.091858 |\n| 24 | Grid | 2.628747 | 170.016143 | 3.088179 |\n| 24 | Continuous | 2.616144 | 169.232569 | 3.085041 |\n| 24 | Finite-stage | **2.562640** | **167.792927** | **3.030234** |"+ },+ "createdAt": "2026-11-13T16:24:32.951Z",+ "modifiedAt": "2026-11-13T16:24:32.951Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=cGyNa8JVSa",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/cjxov8l44d.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/cjxov8l44d.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "cJXoV8L44D",+ "replyTo": "QSWcTAaUQ2",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "#### B. Further comparison with BézierFlow\n\nWe directly compared against the BézierFlow SiT Compatibility Port at NFE12.\n\n| Method | ADM-FID50k ↓ | DINOv2 FD ↓ | CLIP-FID ↓ |\n| --------------------------------- | ------------ | -------------- | ------------ |\n| BézierFlow SiT Compatibility Port | 3.184069 | 182.942166 | 3.379921 |\n| **Ours: Shared Adaptation (RK4)** | **2.853464** | **168.864649** | **3.274840** |\n\nOur RK4 configuration achieves lower values on all three distances in this comparison.\n\nWe also checked different BézierFlow training configurations.\n\n| BézierFlow Configuration | FID |\n| ------------------------------- | ---------- |\n| Same trajectory, 125 updates | 3.2237 |\n| Same trajectory, 500 updates | 3.2243 |\n| Increased to 200 training pairs | 3.1513 |\n| Ours: Shared Adaptation (RK4) | **2.8535** |\n| Ours: Shared Model + Midpoint | **2.8420** |\n\nIncreasing BézierFlow updates from 125 to 500 on the same trajectory did not improve FID. Increasing the number of training pairs to 200 reduced FID, but it remained above Shared RK4.\n\nDeploying the same shared model with Midpoint gives **FID 2.8420**.\n\n#### C. Optimized schedules and specialized solvers\n\nWe added ImageNet-256 comparisons with training-free samplers, optimized schedules, and learned specialized solvers at NFE12.\n\n| Method | ADM-FID50k ↓ | DINOv2 FD ↓ | CLIP-FID ↓ |\n| --------------------------------- | ------------ | -------------- | ------------ |\n| STORK Order-2 | 3.131723 | 182.870190 | 3.293903 |\n| STORK + Frozen Clock | 3.087859 | 181.441707 | 3.272954 |\n| Bespoke RK2 Full-port | 2.884906 | 179.971207 | **3.155823** |\n| Bespoke RK2 Resource-cut | 2.911586 | 181.370197 | 3.167371 |\n| Ours: Shared Adaptation (Heun) | 3.993210 | 197.755778 | 3.990408 |\n| **Ours: Shared Adaptation (RK4)** | **2.853464** | **168.864649** | 3.274840 |\n\nShared RK4 has lower ADM-FID50k and DINOv2 FD than both Bespoke configurations, while Bespoke has better CLIP-FID.\n\nShared RK4 also has lower ADM-FID50k and DINOv2 FD than STORK, with slightly higher CLIP-FID.\n\nThe supplement reports full results for Uniform Native Midpoint and the AYS MC128 Resource Port.\n\nThese results support competitiveness in the tested low-NFE ImageNet configurations.\n\n#### D. Quality at similar adaptation cost\n\nTo address your request, we measured acquisition costs on ImageNet-256.\n\n| Method | Acquisition Cost (seconds) |\n| ------------------------------------------------------------ | -------------------------- |\n| Uniform Native Midpoint | 0 |\n| AYS-flow-grid Heun (MC128 Port) | 7,463.81 |\n| Bespoke RK2 Full-budget Port | 15,034.45 |\n| Bespoke RK2 Resource-cut Port | 9,571.74 |\n| Ours: Shared Adaptation (Stage I only) | 7,822.59 |\n| Ours: Full Pipeline (Stage I + Residual Candidates + Selection) | 9,574.85 |\n\nThe full procedure costs 9,574.85 seconds, only **3.11 seconds** more than Bespoke Resource-cut's 9,571.74 seconds. At this similar cost, Shared RK4 has lower ADM-FID50k and DINOv2 FD, while Bespoke has better CLIP-FID.\n\nStage I alone costs 7,822.59 seconds. Stage II adds 1,752.26 seconds for candidate acquisition and selection.\n\nIn this SiT setting, the prespecified development selection rule chooses the exact Stage-I fallback for both Heun and RK4. **Removing Stage II preserves final deployment quality and saves its acquisition cost.**\n\n#### E. Interaction between training and deployment solvers\n\nWe added a full 2×2 experiment on CIFAR-10, using Heun and Midpoint as both training and deployment solvers.\n\nThe table summarizes FID50k for all four combinations. \n\n| Training solver | Heun deployment | Midpoint deployment |\n| --------------- | ------------------: | ------------------: |\n| Heun | **8.9048 ± 0.1904** | 6.4433 ± 0.2545 |\n| Midpoint | 36.4151 ± 1.1783 | **4.0793 ± 0.0562** |\n\n**The benefit of a training solver depends on the deployment solver.** Heun training gives lower FID with Heun deployment, while Midpoint training gives lower FID with Midpoint deployment.\n\nThe original CIFAR-10 Heun result therefore does not establish the framework's performance limit. The controlled Midpoint experiment achieves better quality, and the full cross experiment supports a substantial interaction between training and deployment solvers.\n\nWe will report FID50k, DINOv2 FD, and CLIP-FID for all four combinations in the supplement and account for the interaction when interpreting solver performance."+ },+ "createdAt": "2026-11-13T16:31:16.482Z",+ "modifiedAt": "2026-11-13T16:31:16.482Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=cJXoV8L44D",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/iawcfktn7c.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/iawcfktn7c.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "IaWCFKtN7c",+ "replyTo": "02HlXDmqwA",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair NgE7",+ "content": {+ "comment": "Dear Reviewer,\n\nThe discussion deadline is approaching. Please review the authors’ responses and clearly indicate whether they adequately address your concerns. Kindly update your score if appropriate.\n\nBest regards,\n\nAC"+ },+ "createdAt": "2026-11-19T02:16:10.894Z",+ "modifiedAt": "2026-11-19T02:16:10.894Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=IaWCFKtN7c",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/jkz6df5vu4.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/jkz6df5vu4.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "jkZ6dF5vu4",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer vr7v",+ "content": {+ "paper_summary": "The paper post-trains the exact few-step sampling map of a flow-matching model for a given solver and NFE. In Stage I, a terminal distribution loss is differentiated through the deployed solver; the loss is a Fréchet distance on projected Inception pool-3 features, plus FM anchor terms. This updates a late subset of the network and a 16-logit monotone time reparameterization (\"clock\") shared across Heun, RK3, and RK4. In Stage II, the network is frozen, small solver-specific residual clocks are learned, and a held-out alignment statistic decides whether each one is deployed. On a C2OT CIFAR-10 model at NFE=12, mean CleanFID10k drops from 46.8 to 7.70 after Stage I and to 7.33 after Stage II. On SiT-XL/2, a finite-stage temporal operator improves Heun and RK4 FID50k by 0.56 and 0.14. Further experiments cover B-series analysis, transfer across budgets and RK2 tableaus, composition with STORK, and four non-image domains.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "+ Optimizing the deployed solver- and budget-specific map is well motivated. The method adds no NFE at deployment and keeps a single field across solvers.\n+ The B-series analysis and the NFE-decay study (5.586% → 2.513% → 0.250%) support the claim that the gains come from finite-step error.\n+ Statistical practice is careful (paired streams, multiple seeds, rules frozen before confirmation, 50k-sample FID), and the coverage is broad, including non-image domains.",+ "critical_weaknesses": "- The Stage I objective is a Fréchet distance on CleanFID Inception features, essentially the same network as the evaluation metric. The headline C2OT gain (46.8 → 7.7) may therefore partly reflect metric fitting.\n- Quality is not competitive: BézierFlow reaches 6.19/5.08/3.96 FID50k at NFE=8/12/24, versus 20.56/9.43/5.49 for the proposed method (Sec. 5.9). Optimized schedules and bespoke solvers are not compared.\n- Stage II adds considerable machinery for small gains (4.8% on C2OT, none for Heun), and heavy non-standard terminology makes the paper hard to follow.",+ "questions_for_authors": "1. Can you report the main C2OT and SiT results with features independent of the training objective (e.g., DINOv2 FD and CLIP-FID for all rows)?\n2. How does the method compare with an optimized timestep schedule (Sabour et al., 2024) or bespoke solvers (Shaul et al., 2024) at the same NFE and a similar adaptation cost?\n3. On SiT, how much benefit is lost if Stage II is removed?",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 2+ },+ "createdAt": "2026-10-22T03:47:27.647Z",+ "modifiedAt": "2026-11-06T12:35:00.213Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=jkZ6dF5vu4",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/lwwbo4pon0.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/lwwbo4pon0.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Lwwbo4pon0",+ "replyTo": "6o0JR2T6Fz",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "#### B. Acquisition and adaptation costs\n\nWe measured ImageNet-256 acquisition costs to compare methods at similar adaptation budgets.\n\n| Method | Acquisition Cost (seconds) |\n| ------------------------------------------------------------ | -------------------------- |\n| Uniform Native Midpoint | 0 |\n| AYS-flow-grid Heun (MC128 Port) | 7,463.81 |\n| Bespoke RK2 Full-budget Port | 15,034.45 |\n| Bespoke RK2 Resource-cut Port | 9,571.74 |\n| Ours: Shared Adaptation (Stage I only) | 7,822.59 |\n| Ours: Full Pipeline (Stage I + Residual Candidates + Selection) | 9,574.85 |\n\nThe zero cost for Uniform Native Midpoint means no extra model adaptation. Inference still requires computation.\n\n- Stage-I Shared Adaptation costs **7,822.59 seconds**, similar to the AYS MC128 Port's 7,463.81 seconds.\n- Stage I costs less than Bespoke Resource-cut's 9,571.74 seconds.\n- The full two-stage procedure costs 9,574.85 seconds, less than Bespoke Full-budget's 15,034.45 seconds.\n- The full procedure and Bespoke Resource-cut differ by only **3.11 seconds, or about 0.0325%**.\n\nAt this nearly equal measured acquisition cost, Shared RK4 has lower ADM-FID50k and DINOv2 FD, while Bespoke has better CLIP-FID. This compares both quality and adaptation cost.\n\n#### C. Cross-budget transfer and reuse across configurations\n\nOur method also addresses reuse of an adapted pretrained model across solvers and budgets.\n\nOn CIFAR-10, one shared adaptation costs **281.55 seconds** and is reused across eight prespecified solver/budget configurations. Adaptation uses Heun NFE8/16. Evaluation includes NFE12, NFE24, and other prespecified solvers without acquiring a new shared model for each configuration.\n\nOn ImageNet-256 SiT, we acquire the finite-stage temporal operator at NFE12, freeze it, and apply it directly at NFE8 and NFE24 without refitting or selecting it for those budgets.\n\nFor Heun NFE8, ADM-FID50k decreases from the Continuous Control's 14.271673 to 11.947994. At NFE24, it decreases from 2.616144 to 2.562640. For RK4 NFE8, it decreases from 7.610743 to 7.471832. The RK4 NFE24 gain is 0.000362.\n\nThe learned time parameterization thus transfers to multiple NFE settings without further adaptation to the target budget.\n\n### Comment 3. Introduction and method intuition\n\n> **Question.** The Introduction is too compressed and does not adequately explain the motivation or method intuition.\n\n**Response 3**\n\nWe reorganized the Introduction around the gap between continuous-time models and finite-step deployment before introducing the optimization objectives and numerical analysis. Please see the updated PDF.\n\n### Comment 4. Blurred qualitative comparison\n\n> **Question.** The first fixed-noise qualitative comparison in the appendix is blurred and hard to read.\n\n**Response 4**\n\nThank you. We are temporarily unable to retrieve the generated image due to device issues. We will remake and replace the figure later."+ },+ "createdAt": "2026-11-13T16:27:37.273Z",+ "modifiedAt": "2026-11-13T16:27:37.273Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=Lwwbo4pon0",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/p2evdtrvar.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/p2evdtrvar.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "p2evdtRvAR",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer qRBU",+ "content": {+ "paper_summary": "This paper addresses the mismatch between continuous-time flow-matching training and few-step deployment by directly optimizing the discrete solver–budget map. Stage I jointly adapts a restricted subset of velocity-field parameters and a shared monotone clock across solvers using a terminal distribution objective with flow-matching regularization. Stage II freezes the field and learns lightweight solver-specific clock refinements. A held-out alignment statistic is proposed to guide their deployment, without additional field evaluations at inference. On a public C2OT-trained class-conditional CIFAR-10 model at NFE12, mean CleanFID10k across Heun, RK3, and RK4 decreases from 46.824 to 7.704 after shared adaptation and to 7.334 with selected refinements. A separate finite-stage temporal operator improves NFE12 ADM-FID50k over grid and continuous-clock controls on frozen SiT-XL/2 for both Heun and RK4. Further analyses examine solver dependence, residual capacity, diminishing gains at higher NFE, and transfer limitations.",+ "presentation": 2,+ "informativeness": 3,+ "soundness": 2,+ "critical_strengths": "**1. A practically useful deployment-aligned design supported by low-NFE results.**\n\nThe paper directly optimizes the discrete solver–budget map used at inference. Its two-stage design combines shared field–clock adaptation with lightweight solver-specific clock refinement, allowing multiple solvers to reuse one adapted velocity field without additional field evaluations. Table 1 demonstrates substantial improvements from shared adaptation over the untouched C2OT-trained CIFAR-10 model at NFE12. Separately, Table 2 shows that a finite-stage temporal operator improves NFE12 ADM-FID50k over grid and continuous-clock controls for both Heun and RK4 on a frozen SiT-XL/2 checkpoint. These results support the practical value of adapting sampling behavior to the deployment configuration.\n\n**2. Informative analysis of solver-dependent calibration and its limitations.**\n\nThe paper examines matched versus mismatched deployment solvers, residual capacity, equal-compute refinement, and diminishing gains at higher NFE. These experiments show that the gains from solver-specific adaptation and the preferred residual-clock capacity vary across solvers and receivers, and that retaining a shared clock can be preferable. The inclusion of negative results and independent-feature evaluations helps characterize the scope of the method. This analysis is consequential because it provides evidence about when specialization is useful, rather than relying solely on aggregate improvements.",+ "critical_weaknesses": "**1. The incremental benefit of the selected residual-clock package could be isolated more convincingly.**\n\nMost of the headline C2OT improvement comes from shared field–clock adaptation. In the residual-capacity study, positive-capacity candidates receive additional refinement updates, whereas the zero-capacity action retains the Stage-I clock. A continued-shared-clock comparison under matched optimization budgets would help assess whether the selected (0,32,8) package offers gains beyond additional shared-clock optimization; isolating the effect of increased capacity would require an appropriate capacity control. The SB-CFM equal-compute control provides useful supporting evidence, but its FID gains are concentrated in RK3: Heun and RK4 worsen in FID on average, while the pooled FID50k improvement is 0.805% (supplementary Table 39). In the accompanying DINOv2 evaluation, however, conditioning improves FD in 8/9 cells and KID in 9/9 cells. Moreover, supplementary Section 30 explicitly limits the selected C2OT package's validation to one frozen receiver, with no selected-action FID50k or second-backbone confirmation. These limitations qualify the attribution and robustness of the selected residual package, rather than the demonstrated benefit of shared adaptation.\n\n**2. Some transfer and robustness statements need clearer distinctions between proxy and FID evidence.**\n\nSection 5.2 describes SiT cross-budget improvements as FID gains, but the reported values match the projected Fréchet-risk differences in supplementary Table 52, whose surrounding text refers to a future FID evaluation. Similarly, the 10/10 residual-retraining result in supplementary Table 46 measures proxy improvement on a fixed Stage-I receiver and evaluation stream, rather than repeated FID confirmation. The main text should identify these metrics and statistical units explicitly. These reporting issues limit the strength of the cross-budget transfer and robustness claims, while leaving the directly reported C2OT and SiT NFE12 FID improvements intact.",+ "questions_for_authors": "**1. Attribution of the selected residual package’s gains.**\n\nFor the C2OT (0,32,8) package, how does refinement compare with continuing to optimize the shared clock under matched optimization budgets, batches, noises, and solver exposure? Is an appropriate capacity-controlled comparison available for this package to distinguish solver-specific parameterization from increased clock capacity? These controls would clarify how much of the incremental gain is attributable to specialization.\n\n**2. Validation scope and robustness of the selected package.**\n\nSupplementary Section 30 limits the selected package’s validation to one frozen C2OT receiver, while supplementary Table 46 reports 10/10 proxy improvements for each active solver on a fixed evaluation stream. Are FID-level comparisons available for this specific package across independently adapted Stage-I models or repeated refinement runs? Please distinguish refinement-seed robustness, Stage-I adaptation variability, and generation-stream variability when interpreting the 10/10 result.\n\n**3. SiT cross-budget metrics.**\n\nSection 5.2 describes the NFE8 and NFE24 improvements as FID gains, but the reported values match the projected Fréchet-risk differences in supplementary Table 52, whose surrounding text refers to a future FID evaluation. Are corresponding ADM-FID50k results available? If not, please clarify that this SiT cross-budget result demonstrates transfer in projected risk and revise the associated claims accordingly.",+ "flag_for_ethics_review": "No",+ "rating": 3,+ "confidence": 2+ },+ "createdAt": "2026-10-22T12:14:31.687Z",+ "modifiedAt": "2026-11-06T12:34:57.507Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=p2evdtRvAR",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/pg0c6ygnbg.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/pg0c6ygnbg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "pG0C6YgnBG",+ "replyTo": "cGyNa8JVSa",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "#### B. RK4\n\n| NFE | Branch | ADM-FID50k ↓ | DINOv2 FD ↓ | CLIP-FID ↓ |\n| ---- | ------------ | -----------: | -------------: | -----------: |\n| 8 | Uniform | 7.769353 | 272.327843 | 5.687817 |\n| 8 | Grid | 7.719096 | 271.610109 | 5.669960 |\n| 8 | Continuous | 7.610743 | 270.798442 | 5.608978 |\n| 8 | Finite-stage | **7.471832** | **269.493747** | **5.478290** |\n| 24 | Uniform | 2.262377 | 157.353009 | 2.819068 |\n| 24 | Grid | 2.253491 | **157.118874** | 2.820448 |\n| 24 | Continuous | 2.254748 | 157.195933 | 2.819543 |\n| 24 | Finite-stage | **2.253128** | 157.152908 | **2.813731** |\n\n#### C. Representative comparisons\n\n| Solver / NFE | Control | Control ADM-FID50k | Frozen Finite-stage ADM-FID50k | FID Improvement |\n| ------------ | ---------- | ------------------ | ------------------------------ | --------------- |\n| Heun / 8 | Continuous | 14.271673 | 11.947994 | 2.323679 |\n| Heun / 24 | Continuous | 2.616144 | 2.562640 | 0.053503 |\n| RK4 / 8 | Continuous | 7.610743 | 7.471832 | 0.138911 |\n| RK4 / 24 | Grid | 2.253491 | 2.253128 | 0.000362 |\n\nThese results show how the cross-budget gain varies with solver and budget.\n\nWe will clearly distinguish projected risk, ADM-FID50k, and independent-feature evaluation. We will retain the **near-zero RK4 NFE24 result** and the adverse changes in the relevant metrics."+ },+ "createdAt": "2026-11-13T16:24:44.395Z",+ "modifiedAt": "2026-11-13T16:24:44.395Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=pG0C6YgnBG",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/qswctaauq2.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/qswctaauq2.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QSWcTAaUQ2",+ "replyTo": "jkZ6dF5vu4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Comment 1. Metric fitting in Stage I\n\n> **Question.** Stage I optimizes Fréchet distance in CleanFID Inception features, and final evaluation uses the same feature network. Does this cause metric fitting?\n>\n> The C2OT reduction from 46.8 to 7.7 may partly reflect fitting to the evaluation metric. Please add independent metrics such as DINOv2 FD and CLIP-FID.\n\n**Response 1**\n\nThank you for raising the possible dependence between the training objective and evaluation metric.\n\nWe added **DINOv2-L/14 FD and CLIP ViT-B/32 Fréchet distance** to the main C2OT and SiT experiments, using the same saved images as the Inception evaluation.\n\nThe C2OT NFE12 results are below.\n\n| Solver / Arm | Inception FID50k | DINOv2 FD | CLIP-FID |\n| ---------------------- | ---------------- | --------- | -------- |\n| Heun Original | 60.7317 | 449.9330 | 18.0311 |\n| Heun Shared / Selected | 5.2044 | 276.0942 | 4.6713 |\n| RK3 Original | 33.6879 | 346.8749 | 12.2536 |\n| RK3 Shared | 6.4163 | 268.0954 | 7.1348 |\n| RK3 Selected | 5.4275 | 264.4108 | 5.8238 |\n| RK4 Original | 39.9393 | 360.1251 | 14.0622 |\n| RK4 Shared | 5.2778 | 260.1031 | 6.1451 |\n| RK4 Selected | 5.1480 | 259.3405 | 5.8425 |\n\nAll shared-adaptation arms improve DINOv2 FD and CLIP-FID over the original model. Both active residual arms also improve these independent distances over their shared starting points.\n\nThe main gains therefore extend beyond the Inception feature space used in training.\n\nWe also tested training-feature and projection-dimension sensitivity using Inception, DINOv2, and CLIP features with 16-, 32-, and 64-dimensional projections.\n\nAll **nine training configurations** outperform the matched zero-fit control in the two feature spaces excluded from their training objective.\n\nWe will add these independent-feature evaluations and clearly state the training features, evaluation features, and sample counts for FID10k and FID50k.\n\n### Comment 2. Generation quality and external baselines\n\n> **Question.** Generation quality remains less competitive than methods such as BézierFlow. Comparisons with optimized timestep schedules and specialized solvers are missing.\n\n**Response 2**\n\nThank you for identifying these gaps. We considered the results of BézierFlow, optimized schedules, and specialized solvers, then added controlled comparisons and mechanism analysis on CIFAR-10 and ImageNet-256.\n\nThe new experiments show that **performance depends strongly on the training solver, deployment solver, and their interaction with the adapted velocity field**. We address quality, solver interaction, and deployment applicability below. Code is available in the [anonymous repository](https://anonymous.4open.science/r/few-step-sampler-review-11B8/).\n\n#### A. The original CIFAR-10 quality gap\n\nWe agree with your observation about the original Heun configuration. It did not achieve a better FID than BézierFlow at NFE8, NFE12, or NFE24.\n\nWe then tested Midpoint training and Midpoint deployment with the same initial checkpoint, NFE12, training objective, model capacity, and 64 optimization updates.\n\n| Method | FID50k ↓ | DINOv2 FD ↓ | CLIP-FID ↓ |\n| ------------------------------------------------- | ------------------- | ------------ | ---------- |\n| BézierFlow Fixed Compatibility Artifact | 5.0717 | 382.8416 | 5.1506 |\n| **Ours: Midpoint Training → Midpoint Deployment** | **4.0793 ± 0.0562** | **374.3220** | **2.5748** |\n\nAll three distances improve.\n\n- Inception FID50k decreases from 5.0717 to **4.0793**, about **19.6%**.\n- DINOv2 FD decreases from 382.8416 to 374.3220.\n- CLIP-FID decreases from 5.1506 to 2.5748.\n\nAll three metrics improve in **all nine paired conditions** formed by three independent training seeds and three independent generation streams.\n\nThe corresponding Heun training and deployment results in the same CIFAR-10 diagnostic are below.\n\n| Method | FID50k ↓ |\n| --------------------------------------------- | ------------------- |\n| BézierFlow Fixed Compatibility Artifact | 5.0717 |\n| Ours: Heun Training → Heun Deployment | 8.9208 ± 0.1920 |\n| Ours: Midpoint Training → Midpoint Deployment | **4.0793 ± 0.0562** |\n\nThe original gap is concentrated in the Heun configuration. It does not establish an overall lack of competitiveness for the adaptation framework on CIFAR-10."+ },+ "createdAt": "2026-11-13T16:28:24.998Z",+ "modifiedAt": "2026-11-13T16:28:24.998Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=QSWcTAaUQ2",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/snlimknuep.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/snlimknuep.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "SnLiMKnueP",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair NgE7",+ "content": {+ "title": "Reminder: Discussion Deadline — November 18",+ "comment": "Dear Reviewers,\n\nThank you for your valuable time and contributions to ICLR. This is a friendly reminder to review the authors' responses and engage in discussions with them. The discussion deadline is **November 18**.\n\nThank you for your continued efforts!\n\nACs"+ },+ "createdAt": "2026-11-16T01:35:59.310Z",+ "modifiedAt": "2026-11-16T01:35:59.310Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=SnLiMKnueP",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/u26jhb1eub.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/u26jhb1eub.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "U26jHB1EUB",+ "replyTo": "cJXoV8L44D",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "#### F. Method scope and contributions\n\nBézierFlow focuses on absolute quality for few-step generation. Our work addresses adapting pretrained Flow Matching models to practical low-NFE deployment.\n\nOur method has three main features.\n\n**(a) Shared field-and-clock adaptation**\n\nWe jointly adjust part of the velocity field and a shared time parameterization to adapt finite-step generation without an external teacher.\n\n**(b) Reuse across configurations and budgets**\n\nOn CIFAR-10, one shared adaptation costs 281.55 seconds and is reused across eight prespecified solver/budget configurations.\n\nOn ImageNet-256, the frozen finite-stage temporal operator acquired at NFE12 transfers directly to NFE8 and NFE24 without refitting.\n\n**(c) Conditional solver-specific refinement**\n\nResidual refinement is retained only when validation supports it. Otherwise, deployment returns exactly to the shared adaptation.\n\nOur contribution is a deployment-aware post-training framework for pretrained Flow Matching models. Shared adaptation, reuse across configurations, and optional specialization improve low-step deployment. We do not claim superiority to BézierFlow across all datasets and NFE settings.\n\n### Comment 3. Stage-II complexity and benefit\n\n> **Question.** Stage II adds complexity for a small gain. How much performance is lost if Stage II is removed on SiT?\n\n**Response 3**\n\nThank you for this question.\n\n#### A. Direct comparison on SiT-XL/2 ImageNet-256\n\n| Solver | Stage-I FID | Raw Residual FID | Final selection |\n| ------ | ----------- | ---------------- | ---------------- |\n| Heun | 3.993210 | 4.000501 | Stage-I Fallback |\n| RK4 | 2.853464 | 2.855850 | Stage-I Fallback |\n\nNeither raw residual candidate improves on Stage I. The development selection rule, fixed before formal evaluation, chooses the exact Stage-I fallback for both solvers.\n\nThus, **removing Stage II causes no deployment-quality loss in this SiT setting**.\n\nRemoving residual training and selection reduces the shared acquisition cost from 9,574.851 to 7,822.585 seconds, saving **1,752.266 seconds**. This is a one-time shared acquisition and selection saving. Inference speed is unaffected, and the saving is not counted separately for each solver.\n\n#### B. Larger, repeatable gains on C2OT–RK3\n\nThe table shows NFE12 FID50k results on the original paired generation stream.\n\n| Stage-I model | Stage I | With fixed Stage II | Relative FID reduction |\n| ------------------------ | ------- | ------------------- | ---------------------- |\n| Original selection model | 6.4163 | 5.4275 | **15.41%** |\n| Additional model 1 | 6.3271 | 4.9968 | **21.03%** |\n| Additional model 2 | 5.9179 | 4.7085 | **20.44%** |\n\nWe will clarify that **Stage I is the core of the method, and Stage II is optional solver-specific refinement**. Its value depends on the model, solver, and deployment budget. Extra residual parameters do not guarantee better quality.\n\n### Comment 4. Nonstandard terminology\n\n> **Question.** Too many nonstandard terms make the method hard to understand.\n\n**Response 4**\n\nThank you for pointing this out. We will use consistent terminology across the Abstract, Introduction, Methods, tables, and figure captions, and reduce repeated descriptions of the framework while retaining the mathematical definitions and reproducibility details. Please see the updated PDF."+ },+ "createdAt": "2026-11-13T16:31:29.213Z",+ "modifiedAt": "2026-11-13T16:31:29.213Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=U26jHB1EUB",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/uknhsvsd8y.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/uknhsvsd8y.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "UkNHSvsD8y",+ "replyTo": "p2evdtRvAR",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Comment 1. Attribution of the residual-clock gain\n\n> **Question.** How do you show that the selected residual clock gains from solver-specific specialization rather than additional shared-clock optimization?\n>\n> In the capacity experiment, positive-capacity candidates receive extra updates, while the zero-capacity candidate retains the Stage-I clock. The gain may therefore come from the extra optimization budget.\n>\n> Please add two controls.\n>\n> - Continue optimizing the shared clock with the same update budget.\n> - Control for capacity to distinguish added parameters from solver-specific parameterization.\n\n**Response 1**\n\nThank you for raising this issue. We added **Continued Shared Clock** and **Shared-capacity Control** experiments. All controls start from the same frozen Stage-I model and use paired training batches, noise, and solver exposure.\n\nWe tested 48 updates per candidate, 96 updates across the two retained candidates, and 192 updates matching the original four-capacity experiment. The 192-update controls use the same four blocks of random numbers for 48 updates each, with continuous optimizer state.\n\nThe table shows the 192-update controls at NFE12 using 50,000 paired generated images. Each cell gives Inception FID / DINOv2 FD / CLIP-FID. Lower is better for all three.\n\n| Solver | Selected Action | Continued Shared (192 updates) | Shared Capacity (192 updates) |\n| ------ | -------------------------- | ------------------------------ | ----------------------------- |\n| Heun | 5.2044 / 276.0942 / 4.6713 | 5.5399 / 274.5299 / 3.3062 | 5.7395 / 278.1588 / 3.3396 |\n| RK3 | 5.4275 / 264.4108 / 5.8238 | 5.6606 / 266.4934 / 6.2483 | 6.0504 / 269.9290 / 7.0170 |\n| RK4 | 5.1480 / 259.3405 / 5.8425 | 4.8606 / 259.4046 / 5.1462 | 4.8296 / 260.6999 / 4.5061 |\n\nThese results support an independent contribution from **solver-specific specialization**, especially for the RK3.\n\nThe selected C2OT residual package contains 40 active residual logits, giving 38 softmax degrees of freedom. We added a corresponding Shared39 capacity control, plus Shared32 and Common-K8 controls. Different solvers implement different finite-step numerical maps. Their local sensitivity directions and full responses to time reparameterization therefore differ, so the gain depends on the solver.\n\n### Comment 2. Validation scope and robustness of the selected residual package\n\n> **Question.** Do the 10/10 residual retraining results establish robustness across models and random seeds?\n>\n> Supplementary Section 30 limits validation to one frozen C2OT receiver. The 10/10 results in Supplementary Table 46 are proxy improvements with a fixed Stage-I receiver and evaluation stream.\n>\n> Please provide FID comparisons across independent Stage-I models or independent refinement runs. Distinguish refinement-seed robustness, Stage-I adaptation variability, and generation-stream variability.\n\n**Response 2**\n\nWe completed additional FID50k experiments with **three independent Stage-I models, ten residual refinement seeds, and three independent generation streams**. All 105 experimental conditions and 315 distance measurements passed the full validation checks.\n\nThe fixed residual package now has formal confirmation across Stage-I models, independent refinement runs, and generation streams.\natability across refinement runs and generation streams on the fixed Stage-I receiver.\n\n#### A. FID50k across independent Stage-I models\n\nWe fixed the selected residual package and refinement seed, then evaluated three independent Stage-I models on three independent generation streams each.\n\nThe table reports the arithmetic mean of the three FID50k values. Each stream is evaluated separately. The images are not pooled into an FID150k evaluation.\n\n| Stage-I Model | RK3: Shared → Residual Package | RK4: Shared → Residual Package |\n| --------------------------------------- | ------------------------------ | ------------------------------ |\n| 20281951 (original selection model) | 6.4031 → **5.4284** | 5.2799 → **5.1531** |\n| 20281952 (additional independent model) | 6.3536 → **5.0358** | 4.7986 → **4.7162** |\n| 20281953 (additional independent model) | 5.9291 → **4.7370** | 4.5624 → **4.4295** |\n\nThe two additional models, 20281952 and 20281953, were not used to select residual capacity. They provide validation beyond the original selection model.\n\n- RK3 improves FID50k on all three Stage-I models.\n- RK4 also improves FID50k on all three models.\n- For both solvers, FID, DINOv2 FD, and CLIP-FID improve on every generation stream of every Stage-I model.\n\nThe gain thus transfers to two independently adapted Stage-I models beyond the model used for selection."+ },+ "createdAt": "2026-11-13T16:23:27.121Z",+ "modifiedAt": "2026-11-13T16:57:59.416Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=UkNHSvsD8y",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/v1ltmyd0xz.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/v1ltmyd0xz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "v1LTmyd0xZ",+ "replyTo": "p2evdtRvAR",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer qRBU",+ "content": {+ "comment": "Thank you for the detailed responses and the additional experiments.\n\nQ2 and Q3 are resolved. The new FID50k results across Stage-I models (including two not used for capacity selection), refinement seeds, and generation streams address the robustness question. The corrected SiT metric labels, together with the new ADM-FID50k results, address the reporting issue. I appreciate that the near-zero RK4 NFE24 result will be retained.\n\nFor Q1, the new controls support solver-specific specialization for RK3, which improves on both controls in all three distances. For RK4, however, the selected residual is worse than both the continued-shared clock and the shared-capacity control in Inception FID (5.1480 vs. 4.8606 and 4.8296) and CLIP-FID (5.8425 vs. 5.1462 and 4.5061), while DINOv2 FD marginally favors the residual (259.34 vs. 259.40 and 260.70). Please state in the revision that, under these controls, the specialization benefit is supported for RK3 but not for RK4.\n\nPlease also reconcile the residual parameter count. The paper reports 120 active parameters (96 for RK3 and 24 for RK4), whereas the response states 40 active logits, and the Shared39 control appears to be sized from the latter. The paper’s figures coincide with the “Scalars” entries for K = 32 and K = 8 in Supplementary Table 44. Please clarify which count is correct and, if needed, correct the abstract, Section 3.3, and Supplementary Section 30.\n\nThese points qualify the residual-clock claims but do not change my overall assessment. I will keep my rating."+ },+ "createdAt": "2026-11-18T07:39:34.499Z",+ "modifiedAt": "2026-11-18T07:39:34.499Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=v1LTmyd0xZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/xj3bf5kpjw.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/xj3bf5kpjw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "XJ3Bf5Kpjw",+ "replyTo": "Lwwbo4pon0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer,\n\nAs the rebuttal window is drawing to a close, we would be thankful if you could spare some time to look over our responses to your questions.\n\nYour opinions mean a lot to us. Thank you very much for your careful review and constructive guidance.\n\nBest regards,\n\nThe Authors"+ },+ "createdAt": "2026-11-19T10:49:24.735Z",+ "modifiedAt": "2026-11-19T10:49:24.735Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=XJ3Bf5Kpjw",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/notes/zp6azwy81v.json added
+++ b/reviews/openreview/3u3vpwgtar/notes/zp6azwy81v.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Zp6aZWY81V",+ "replyTo": "U26jHB1EUB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer,\n\nAs the rebuttal window is drawing to a close, we would be thankful if you could spare some time to look over our responses to your questions.\n\nYour opinions mean a lot to us. Thank you very much for your careful review and constructive guidance.\n\nBest regards,\n\nThe Authors"+ },+ "createdAt": "2026-11-19T10:47:54.367Z",+ "modifiedAt": "2026-11-19T10:48:51.845Z",+ "url": "https://openreview.net/forum?id=3U3vPwgTAR¬eId=Zp6aZWY81V",+ "license": "CC-BY-4.0"+}
reviews/openreview/3u3vpwgtar/submission.json added
+++ b/reviews/openreview/3u3vpwgtar/submission.json@@ -0,0 +1,21 @@+{+ "schema": "submission/1",+ "id": "3U3vPwgTAR",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 46220,+ "keywords": [+ "flow matching",+ "generative models",+ "numerical ODE solvers",+ "temporal allocation",+ "few-step sampling",+ "sampling schedules",+ "zero-target-fit transfer"+ ],+ "url": "https://openreview.net/forum?id=3U3vPwgTAR",+ "license": "CC-BY-4.0"+}
versions/v_n7tqa7ey.json added
+++ b/versions/v_n7tqa7ey.json@@ -0,0 +1,21 @@+{+ "date": "2026-09-18",+ "kind": "submitted",+ "label": "ICLR 2027",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 46220,+ "url": "https://openreview.net/forum?id=3U3vPwgTAR",+ "reviews": "openreview/3u3vpwgtar",+ "evidence": [+ "https://openreview.net/forum?id=3U3vPwgTAR"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=3U3vPwgTAR",+ "evidence": [+ "https://openreview.net/forum?id=3U3vPwgTAR"+ ]+}