A Controlled Benchmark for Weight-Space Model Merging Across Medical Imaging Domains
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:15 UTC · c20544d7c9ad ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "BSIyOUo9Jd"- }- ],- "title": "A Controlled Benchmark for Weight-Space Model Merging Across Medical Imaging Domains",- "authors": [],- "abstract": "Consolidating medical-imaging specialists into a shared model requires preserving performance across distinct imaging domains. Weight-space model merging offers a way to combine independently fine-tuned encoders without retraining, but comparisons between merging methods are sensitive to validation protocols. Official evaluation scripts for TSV-Merge and isotropic merging use wider scaling-coefficient ranges for selected spectral methods than for other tunable baselines. We introduce a controlled benchmark spanning dermoscopy, chest radiography, and histopathology, with three binary tasks and $2{,}000$ training images per specialist. We compare 11 methods across seven vision-transformer backbones and three seeds using a shared scaling-coefficient grid. The best observed merger reaches $0.811$ mean AUROC against $0.853$ for task-aware specialist routing, with tuned Task Arithmetic close behind at $0.808$. We also introduce Gram-LS, a closed-form method based on task-vector projection constraints that performs comparably to tuned summation. Within-method validation tuning improves Gram-LS and Task Arithmetic by approximately $0.030$--$0.035$ AUROC, exceeding the $0.019$ spread among five leading tuned methods, while search bounds can change method rankings. Iso-C and Iso-CTS fall $0.10$--$0.13$ AUROC below tuned summation. These findings establish tuned summation as a strong baseline in this setting and show that specialist references and validation protocols are essential to assessing the performance cost of consolidation.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "efe00d6b-925f-4c7d-8f4a-47aba0cb1ccf"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "A Controlled Benchmark for Weight-Space Model Merging Across Medical Imaging Domains",+ "authors": [],+ "abstract": "Consolidating medical-imaging specialists into a shared model requires preserving performance across distinct imaging domains. Weight-space model merging offers a way to combine independently fine-tuned encoders without retraining, but comparisons between merging methods are sensitive to validation protocols. Official evaluation scripts for TSV-Merge and isotropic merging use wider scaling-coefficient ranges for selected spectral methods than for other tunable baselines. We introduce a controlled benchmark spanning dermoscopy, chest radiography, and histopathology, with three binary tasks and $2{,}000$ training images per specialist. We compare 11 methods across seven vision-transformer backbones and three seeds using a shared scaling-coefficient grid. The best observed merger reaches $0.811$ mean AUROC against $0.853$ for task-aware specialist routing, with tuned Task Arithmetic close behind at $0.808$. We also introduce Gram-LS, a closed-form method based on task-vector projection constraints that performs comparably to tuned summation. Within-method validation tuning improves Gram-LS and Task Arithmetic by approximately $0.030$--$0.035$ AUROC, exceeding the $0.019$ spread among five leading tuned methods, while search bounds can change method rankings. Iso-C and Iso-CTS fall $0.10$--$0.13$ AUROC below tuned summation. These findings establish tuned summation as a strong baseline in this setting and show that specialist references and validation protocols are essential to assessing the performance cost of consolidation.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}