Condition-Dependent Probe Calibration in a World Model’s Own Rollouts
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:17 UTC · 101bd2338028 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "zS2IETPnol"- }- ],- "title": "Condition-Dependent Probe Calibration in a World Model’s Own Rollouts",- "authors": [],- "abstract": "Interpretability work on world models reads latents with probes calibrated on encoder outputs, then reuses them on latents the model generates with its own dynamics; read that way, the intervention effects a model imagines have been found not to match the environment’s. We ask whether that is lost information or a change in the measurement’s own calibration, and whether that calibration is stable across rollout conditions, holding a TD-MPC2 model fixed and varying only how the probe is calibrated. The measured physical variables stay linearly recoverable: on perturbed cheetah states, a map from rolled to encoded latents fit without the targets restores an encoder-calibrated readout from $R^2 = 0.038$ to $0.823$. The map is specific to the condition it was fit in: it keeps only part of its benefit at other horizons, can do worse than no map on another state distribution, and is poorly captured by an orthogonal map, while identity plus a rank-16 correction recovers most of its gain. Recalibration also changes intervention-consistency effect sizes, by up to $2.6\\times$ across four comparisons, without reversing any feature-versus-control separation; in the $2.6\\times$ comparison a post-hoc check finds both readouts above $R^2 = 0.99$ on the corresponding states. In a second architecture, LeWorldModel on Reacher, the encoder-calibrated readout stays almost perfectly accurate on the model’s training distribution, so the large TD-MPC2 mismatch is not universal across the settings tested.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "01ebf631-7b07-493c-9018-a0b076f97143"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Condition-Dependent Probe Calibration in a World Model’s Own Rollouts",+ "authors": [],+ "abstract": "Interpretability work on world models reads latents with probes calibrated on encoder outputs, then reuses them on latents the model generates with its own dynamics; read that way, the intervention effects a model imagines have been found not to match the environment’s. We ask whether that is lost information or a change in the measurement’s own calibration, and whether that calibration is stable across rollout conditions, holding a TD-MPC2 model fixed and varying only how the probe is calibrated. The measured physical variables stay linearly recoverable: on perturbed cheetah states, a map from rolled to encoded latents fit without the targets restores an encoder-calibrated readout from $R^2 = 0.038$ to $0.823$. The map is specific to the condition it was fit in: it keeps only part of its benefit at other horizons, can do worse than no map on another state distribution, and is poorly captured by an orthogonal map, while identity plus a rank-16 correction recovers most of its gain. Recalibration also changes intervention-consistency effect sizes, by up to $2.6\\times$ across four comparisons, without reversing any feature-versus-control separation; in the $2.6\\times$ comparison a post-hoc check finds both readouts above $R^2 = 0.99$ on the corresponding states. In a second architecture, LeWorldModel on Reacher, the encoder-calibrated readout stays almost perfectly accurate on the model’s training distribution, so the large TD-MPC2 mismatch is not universal across the settings tested.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}