potentialpaper

When Can A Trajectory Be Aligned? An Information Bound for Amplitude-Phase Separation

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:18 UTC · 8ab50029032e ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "fwv6xSOiov"
- }
- ],
- "title": "When Can A Trajectory Be Aligned? An Information Bound for Amplitude-Phase Separation",
- "authors": [],
- "abstract": "Elastic functional data analysis separates trajectories into amplitude and phase by warping\neach one onto a common template and taking the warps as the phase, and recent work makes the\nwarp a neural network that integrates a positive velocity field. Developed for densely sampled\ncurves, it is now applied to trajectories with very few samples: contrast-enhanced MRI with\nthree post-contrast frames, or ICU chemistry panels drawn three times in two days. We compute\nthe Fisher information a set of measurement times carries about a warp parameter. Under the within-exam baseline normalisation these pipelines apply, it depends\non the centred derivative of the response and the tangent direction of the warp family,\nneither of which involves the estimator, so the bound follows from acquisition metadata alone\nand holds for a network of arbitrary capacity. It implies that a warp pinning both ends of the\ntime axis, the construction these differentiable pipelines are built from, cannot represent a\nrigid arrival delay at all; that a response with constant derivative carries no timing\ninformation once its onset precedes the window, at any sample size or SNR; and that fitting an\nunknown amplitude costs $3.7\\times$ on a near-monotone response. Across six warp families and\nthree encoders, in simulation and on real acquisitions, no configuration exceeds the bound,\nand the endpoint-pinned family recovers $0.595$ of the arrival variation against $1.03$ for\nfree-endpoint ones: impaired on real scans rather than disabled as it is in simulation. On $3{,}303$ prostate DCE-MRI examinations across two protocols, thinning a dense acquisition\ndegrades a measured arrival estimate from $0.25$\\,s at forty samples to $20.1$\\,s at three,\nand the bound tracks that degradation across a $119$-fold range ($r=0.96$). Sample count alone\norders those schedules equally well; holding it at six and moving only where the six fall, the\nbound still orders the measured error. Applied to PhysioNet 2012 timestamps\nalone, the same calculation spans $10.6\\times$ across $25$ ICU variables.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "fe682c35-15ab-4b98-b19d-07e15e134423"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "When Can A Trajectory Be Aligned? An Information Bound for Amplitude-Phase Separation",
+ "authors": [],
+ "abstract": "Elastic functional data analysis separates trajectories into amplitude and phase by warping\neach one onto a common template and taking the warps as the phase, and recent work makes the\nwarp a neural network that integrates a positive velocity field. Developed for densely sampled\ncurves, it is now applied to trajectories with very few samples: contrast-enhanced MRI with\nthree post-contrast frames, or ICU chemistry panels drawn three times in two days. We compute\nthe Fisher information a set of measurement times carries about a warp parameter. Under the within-exam baseline normalisation these pipelines apply, it depends\non the centred derivative of the response and the tangent direction of the warp family,\nneither of which involves the estimator, so the bound follows from acquisition metadata alone\nand holds for a network of arbitrary capacity. It implies that a warp pinning both ends of the\ntime axis, the construction these differentiable pipelines are built from, cannot represent a\nrigid arrival delay at all; that a response with constant derivative carries no timing\ninformation once its onset precedes the window, at any sample size or SNR; and that fitting an\nunknown amplitude costs $3.7\\times$ on a near-monotone response. Across six warp families and\nthree encoders, in simulation and on real acquisitions, no configuration exceeds the bound,\nand the endpoint-pinned family recovers $0.595$ of the arrival variation against $1.03$ for\nfree-endpoint ones: impaired on real scans rather than disabled as it is in simulation. On $3{,}303$ prostate DCE-MRI examinations across two protocols, thinning a dense acquisition\ndegrades a measured arrival estimate from $0.25$\\,s at forty samples to $20.1$\\,s at three,\nand the bound tracks that degradation across a $119$-fold range ($r=0.96$). Sample count alone\norders those schedules equally well; holding it at six and moving only where the six fall, the\nbound still orders the measured error. Applied to PhysioNet 2012 timestamps\nalone, the same calculation spans $10.6\\times$ across $25$ ICU variables.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}