Predict-Then-Adapt: Cross-Plane Joint-Embedding for Test-Time Medical Segmentation
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:18 UTC · 9fc06907064e ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "WhRpXMEjTr"- }- ],- "title": "Predict-Then-Adapt: Cross-Plane Joint-Embedding for Test-Time Medical Segmentation",- "authors": [],- "abstract": "Test-time medical image segmentation adapts source-trained models to unlabeled target volumes under distribution shifts. Existing methods mainly derive adaptation signals from model predictions or individual slices, leaving the intrinsic three-dimensional structure of test volumes underexploited. In particular, orthogonal views observe the same anatomy with exact voxel-wise correspondence, providing natural within-volume supervision. However, a representation that is predictable across views may not remain compatible with the source-trained segmentation task. We propose \\textbf{CP-JEPA}, a \\textbf{C}ross-\\textbf{P}lane \\textbf{J}oint-\\textbf{E}mbedding \\textbf{P}redictive \\textbf{A}daptation framework following a \\textbf{predict-then-adapt} principle. CP-JEPA models cross-plane prediction and task-space translation as two complementary stages. It first predicts masked target-view representations from geometrically corresponding orthogonal views, constructing a JEPA-style objective within each test volume. It then compares the cross-plane prediction with a capacity-matched axial control to isolate geometry-specific counterfactual evidence and translates this evidence into bounded, source-anchored segmentation corrections. CP-JEPA supports both single- and continual-volume adaptation by resetting volume-specific predictive states while selectively retaining reliable task-space evidence across cases. We evaluate CP-JEPA on multi-organ MRI segmentation under single- and continual-volume deployment, with and without labeled target-development data used only for configuration. Across DINOv3- and U-Net-based backbones, CP-JEPA achieves the strongest macro-average performance in three of four evaluation settings and ranks second in the remaining setting, outperforming the strongest TTA baselines by approximately $1.0$ Dice point on average.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "7f4e9837-33e7-43bc-9c4a-9875a5d6b4fe"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Predict-Then-Adapt: Cross-Plane Joint-Embedding for Test-Time Medical Segmentation",+ "authors": [],+ "abstract": "Test-time medical image segmentation adapts source-trained models to unlabeled target volumes under distribution shifts. Existing methods mainly derive adaptation signals from model predictions or individual slices, leaving the intrinsic three-dimensional structure of test volumes underexploited. In particular, orthogonal views observe the same anatomy with exact voxel-wise correspondence, providing natural within-volume supervision. However, a representation that is predictable across views may not remain compatible with the source-trained segmentation task. We propose \\textbf{CP-JEPA}, a \\textbf{C}ross-\\textbf{P}lane \\textbf{J}oint-\\textbf{E}mbedding \\textbf{P}redictive \\textbf{A}daptation framework following a \\textbf{predict-then-adapt} principle. CP-JEPA models cross-plane prediction and task-space translation as two complementary stages. It first predicts masked target-view representations from geometrically corresponding orthogonal views, constructing a JEPA-style objective within each test volume. It then compares the cross-plane prediction with a capacity-matched axial control to isolate geometry-specific counterfactual evidence and translates this evidence into bounded, source-anchored segmentation corrections. CP-JEPA supports both single- and continual-volume adaptation by resetting volume-specific predictive states while selectively retaining reliable task-space evidence across cases. We evaluate CP-JEPA on multi-organ MRI segmentation under single- and continual-volume deployment, with and without labeled target-development data used only for configuration. Across DINOv3- and U-Net-based backbones, CP-JEPA achieves the strongest macro-average performance in three of four evaluation settings and ranks second in the remaining setting, outperforming the strongest TTA baselines by approximately $1.0$ Dice point on average.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}