potentialpaper

When Fisher Information Mispredicts Prior Sensitivity: Model Misspecification, Not Noise

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:18 UTC · c26024f7c7c4 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "BYfFscESp0"
- }
- ],
- "title": "When Fisher Information Mispredicts Prior Sensitivity: Model Misspecification, Not Noise",
- "authors": [],
- "abstract": "Physics-based inverse models resolve what the measurements cannot determine by adding a prior, so\npart of every recovered quantity comes from the prior rather than from the object measured. Fisher\ninformation is the standard tool for predicting how large that part is. We show that the prediction\nfails, characterise when, and give the mechanism. For a maximum a posteriori fit whose Fisher\nmatrix has a near-null direction $v$, the omitted curvature term multiplies every parameter's prior\nsensitivity by a single scalar, $1 - v^\\top C v / \\lambda$, in which the parameter index cancels.\nThe sign of that scalar is the correlation between the fit residual and the model's curvature along\n$v$. That correlation vanishes for noise independent of the model, which is what the standard\njustification assumes. On 4{,}608 clinical MRI exams it does not vanish, and two nulls built from\nthe cohort's own residuals reject both halves of the assumption. The Fisher prediction is then too\nlarge by 29--38\\%, exceeds the measured sensitivity in $92.8\\%$ to $98.8\\%$ of exams, and loses the\nordering across exams for $T_1$. Because the error occupies one eigendirection, it can be repaired\nwithout computing the curvature: shifting a single eigenvalue recovers 92--99\\% of the full-Hessian\ncorrection at two gradient evaluations, whatever the parameter count. Both the failure and the repair reproduce on public diffusion MRI from another laboratory\nand on outdoor photovoltaic modules, and both vanish on transit photometry, where the\nresidual is genuinely noise. The same substitution underlies Laplace\napproximations, influence functions and Fisher-based continual learning. Measured on a neural\nnetwork, with weight decay as the prior, Fisher over-predicts how far the weights follow a shifted\nprior by $2.0$ to $3.4$ times across seven widths, and the exact curvature recovers it to $0.5\\%$.\nOn the clinical images, self-supervised networks differing only in random seed disagree $2$ to\n$3.2\\times$ more along the unconstrained direction than across it. What the measurements cannot\ndetermine, the training run decides.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "1df93930-dffb-41f8-909e-862251cc59f8"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "When Fisher Information Mispredicts Prior Sensitivity: Model Misspecification, Not Noise",
+ "authors": [],
+ "abstract": "Physics-based inverse models resolve what the measurements cannot determine by adding a prior, so\npart of every recovered quantity comes from the prior rather than from the object measured. Fisher\ninformation is the standard tool for predicting how large that part is. We show that the prediction\nfails, characterise when, and give the mechanism. For a maximum a posteriori fit whose Fisher\nmatrix has a near-null direction $v$, the omitted curvature term multiplies every parameter's prior\nsensitivity by a single scalar, $1 - v^\\top C v / \\lambda$, in which the parameter index cancels.\nThe sign of that scalar is the correlation between the fit residual and the model's curvature along\n$v$. That correlation vanishes for noise independent of the model, which is what the standard\njustification assumes. On 4{,}608 clinical MRI exams it does not vanish, and two nulls built from\nthe cohort's own residuals reject both halves of the assumption. The Fisher prediction is then too\nlarge by 29--38\\%, exceeds the measured sensitivity in $92.8\\%$ to $98.8\\%$ of exams, and loses the\nordering across exams for $T_1$. Because the error occupies one eigendirection, it can be repaired\nwithout computing the curvature: shifting a single eigenvalue recovers 92--99\\% of the full-Hessian\ncorrection at two gradient evaluations, whatever the parameter count. Both the failure and the repair reproduce on public diffusion MRI from another laboratory\nand on outdoor photovoltaic modules, and both vanish on transit photometry, where the\nresidual is genuinely noise. The same substitution underlies Laplace\napproximations, influence functions and Fisher-based continual learning. Measured on a neural\nnetwork, with weight decay as the prior, Fisher over-predicts how far the weights follow a shifted\nprior by $2.0$ to $3.4$ times across seven widths, and the exact curvature recovers it to $0.5\\%$.\nOn the clinical images, self-supervised networks differing only in random seed disagree $2$ to\n$3.2\\times$ more along the unconstrained direction than across it. What the measurements cannot\ndetermine, the training run decides.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}