potentialpaper

UEPS: Robust and Efficient MRI Reconstruction

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:18 UTC · 4176d5b3105b ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "0uYfL0n2mS"
- }
- ],
- "title": "UEPS: Robust and Efficient MRI Reconstruction",
- "authors": [],
- "abstract": "Deep unrolled models (DUM) have become the state-of-the-art for accelerated MRI reconstruction, yet their robustness under domain shift remains a critical barrier to clinical adoption. In this work, we identify coil sensitivity map (CSM) estimation as the primary bottleneck limiting generalization. To address this, we propose UEPS, a novel DUM architecture featuring three key designs: (i) an Un-rolled Expanded (UE) design that eliminates CSM dependency by reconstructing each coil independently; (ii) progressive resolution, which leverages k-space-to- image mapping for efficient coarse-to-fine refinement; and (iii) sparse attention tailored to MRI’s 1D undersampling nature. These physics-grounded designs en- able gains in robustness and computational efficiency. We construct a large-scale zero-shot transfer benchmark comprising 10 out-of-distribution (OOD) test sets spanning diverse clinical shifts—anatomy, view, contrast, vendor, field strength, and coil configurations. Extensive experiments demonstrate that UEPS consis- tently and substantially outperforms existing DUM, end-to-end, diffusion, and un- trained methods across all OOD tests, achieving state-of-the-art robustness with low-latency inference suitable for real-time deployment.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "b12c7395-ef79-4b5e-8e16-b741bb13ae44"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "UEPS: Robust and Efficient MRI Reconstruction",
+ "authors": [],
+ "abstract": "Deep unrolled models (DUM) have become the state-of-the-art for accelerated MRI reconstruction, yet their robustness under domain shift remains a critical barrier to clinical adoption. In this work, we identify coil sensitivity map (CSM) estimation as the primary bottleneck limiting generalization. To address this, we propose UEPS, a novel DUM architecture featuring three key designs: (i) an Un-rolled Expanded (UE) design that eliminates CSM dependency by reconstructing each coil independently; (ii) progressive resolution, which leverages k-space-to- image mapping for efficient coarse-to-fine refinement; and (iii) sparse attention tailored to MRI’s 1D undersampling nature. These physics-grounded designs en- able gains in robustness and computational efficiency. We construct a large-scale zero-shot transfer benchmark comprising 10 out-of-distribution (OOD) test sets spanning diverse clinical shifts—anatomy, view, contrast, vendor, field strength, and coil configurations. Extensive experiments demonstrate that UEPS consis- tently and substantially outperforms existing DUM, end-to-end, diffusion, and un- trained methods across all OOD tests, achieving state-of-the-art robustness with low-latency inference suitable for real-time deployment.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}