potentialpaper

Biologically informed generation of protein levels with flow matching

Update ICLR 2027 submission 7d1FUD0fR3: 1 note

@openreview[bot] · 2026-11-24 15:35 UTC · 963602360ac8 ·

Evidence

reviews/openreview/7d1fud0fr3/notes/el3skqmz5f.json modified

+++ b/reviews/openreview/7d1fud0fr3/notes/el3skqmz5f.json
@@ -13,12 +13,12 @@
"critical_strengths": "- Using sequence embeddings to modulate expression gives a principled way to handle protein panels that differ across experiments, and it allows predictions for proteins with no training data (the NEAT-seq experiment), which lookup-table approaches such as CAPTAIN and totalVI cannot make.\n- Encoding heterogeneous metadata as text embeddings is a practical answer to the inconsistent metadata fields across public datasets, and the metadata ablations make some attempt to measure its contribution.\n- The model is small (1.1M parameters, about 6 hours on one GPU), and the inclusion of a discriminative variant trained under the same pipeline is a useful control that more papers should report.",
"critical_weaknesses": "- The claim to be the first flow-matching single-cell foundation model rests only on a recent non-peer-reviewed review [1]. The paper does not discuss earlier flow-based single-cell generative models such as CFGen.\n- The Dataset103_1 zero-shot test count (161,764) equals the training count (145,587) plus the held-out count (16,177), suggesting training cells were evaluated. Zero-shot rows in Tables 2 and 10 also match Table 1 exactly despite supposedly using smaller subsets.\n- The paper claims top performance on all datasets, but scTranslator and even the RNA baseline beat RnaProFlo on GSE194122. CAPTAIN-FT and scTranslator-FT also win on the macaque and Perturb-CITE-seq generalization tests.\n- Cell prompts include test-set cell type labels and Seurat clusters, which in CITE-seq are often derived from protein data. Baselines get no comparable information, and test-set ablations without these fields are missing.\n- Removing the niche attention changes validation cosine only from 0.945 to 0.944 (Table 14). The spatial gains likely come from fine-tuning alone.\n\n[1] Jiang, Shiyu, et al. \"The Landscape of Single-Cell Foundation Models: Design Principles, Applications, and Open Challenges.\" (2026).",
"questions_for_authors": "- Since RnaProDisc matches RnaProFlo on every task, what does the flow-matching formulation add? Can you show that generated protein distributions match observed ones, for example with a distributional distance or per-cell variance calibration?\n- Why is scProTrans compared only in the zero-shot setting, and how were the abstract’s headline improvements (13.9% cosine, 48.2% MSE) computed?",
"flag_for_ethics_review": "No",
- "rating": 2,
+ "rating": 3,
"confidence": 3
},
"createdAt": "2026-10-22T04:07:04.163Z",
- "modifiedAt": "2026-11-06T12:37:59.555Z",
+ "modifiedAt": "2026-11-22T21:22:11.855Z",
"url": "https://openreview.net/forum?id=7d1FUD0fR3&noteId=El3SkQMz5f",
"license": "CC-BY-4.0"
}