potentialpaper

Learning How Much, Not Just What: Cross-Patient Burden Order for CT Vision-Language Pretraining

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:20 UTC · c4f888b08487 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "wysjE8cE3E"
- }
- ],
- "title": "Learning How Much, Not Just What: Cross-Patient Burden Order for CT Vision-Language Pretraining",
- "authors": [],
- "abstract": "Volumetric CT vision–language pretraining learns 3D representations from scan–report pairs, but global and anatomy-aware objectives supervise only correspondence: they establish what is present and leave how much unconstrained. Nothing separates a mild from an extensive case of the same finding along a consistent direction, so the graded burden language in reports collapses into a present/absent signal. Longitudinal supervision would supply this order, but patient-matched CT pairs are scarce at scale; cross-sectional cohorts already encode weak burden cues across different patients. We introduce Spectrum, an anatomy-conditioned framework that represents each study at whole-study and organ scopes. For each organ-mapped pathology, a rule-based scorer mines confidence-filtered lower-to-higher pairs of different patients, and Burden-Direction Alignment (BDA) aligns the pathology-conditioned image delta with the report delta at each scope, separating that direction from its reverse. Because the endpoints are different people, a target-conditioned aligner first makes them comparable, so the delta reflects burden rather than between-patient variation. BDA further separates the selected direction from its reverse, anchors it to the observed higher-burden endpoint, and enforces consistency across ordered triplets. Since every pair is drawn within a single pathology, BDA is designed to constrain intra-class structure that image–report contrast alone never touches. Spectrum attains 85.6 zero-shot AUROC on CT-RATE and 72.7 on external RAD-ChestCT, with consistent gains in linear probing and retrieval. Weak cross-patient order is thus a scalable complement to anatomy-aware correspondence, yielding burden-aware CT representations without longitudinal data.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "ca667c09-8fa6-48b8-96da-c0c8ac3e4f58"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Learning How Much, Not Just What: Cross-Patient Burden Order for CT Vision-Language Pretraining",
+ "authors": [],
+ "abstract": "Volumetric CT vision–language pretraining learns 3D representations from scan–report pairs, but global and anatomy-aware objectives supervise only correspondence: they establish what is present and leave how much unconstrained. Nothing separates a mild from an extensive case of the same finding along a consistent direction, so the graded burden language in reports collapses into a present/absent signal. Longitudinal supervision would supply this order, but patient-matched CT pairs are scarce at scale; cross-sectional cohorts already encode weak burden cues across different patients. We introduce Spectrum, an anatomy-conditioned framework that represents each study at whole-study and organ scopes. For each organ-mapped pathology, a rule-based scorer mines confidence-filtered lower-to-higher pairs of different patients, and Burden-Direction Alignment (BDA) aligns the pathology-conditioned image delta with the report delta at each scope, separating that direction from its reverse. Because the endpoints are different people, a target-conditioned aligner first makes them comparable, so the delta reflects burden rather than between-patient variation. BDA further separates the selected direction from its reverse, anchors it to the observed higher-burden endpoint, and enforces consistency across ordered triplets. Since every pair is drawn within a single pathology, BDA is designed to constrain intra-class structure that image–report contrast alone never touches. Spectrum attains 85.6 zero-shot AUROC on CT-RATE and 72.7 on external RAD-ChestCT, with consistent gains in linear probing and retrieval. Weak cross-patient order is thus a scalable complement to anatomy-aware correspondence, yielding burden-aware CT representations without longitudinal data.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}