Error-Controlled Discovery of Protein Interactions via Conformal Calibration
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:20 UTC · 05016546a272 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "skTyU1azIW"- }- ],- "title": "Error-Controlled Discovery of Protein Interactions via Conformal Calibration",- "authors": [],- "abstract": "Protein language models (PLMs) are powerful predictors of protein interactions, but strong benchmark performance does not ensure reliable discoveries. We introduce PPI-Caliper, a model-agnostic framework that adapts conformal calibration to select interactions at user-specified false discovery rate (FDR) levels using held-out labels without retraining the predictor. Across five species, two PLM-based predictors, and two human training-data versions for each predictor, PPI-Caliper keeps empirical FDR at or below the target level under in-distribution calibration. Under distribution shift, transferred thresholds tend to become conservative when predictive performance improves, but can fail to control FDR when performance deteriorates. PPI-Caliper connects pre-trained interaction scores to explicit error targets and demonstrates why reliable biological discovery requires evaluating calibration alongside predictive accuracy.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "768bb74a-712f-4f75-9ac9-f57bab28fb44"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Error-Controlled Discovery of Protein Interactions via Conformal Calibration",+ "authors": [],+ "abstract": "Protein language models (PLMs) are powerful predictors of protein interactions, but strong benchmark performance does not ensure reliable discoveries. We introduce PPI-Caliper, a model-agnostic framework that adapts conformal calibration to select interactions at user-specified false discovery rate (FDR) levels using held-out labels without retraining the predictor. Across five species, two PLM-based predictors, and two human training-data versions for each predictor, PPI-Caliper keeps empirical FDR at or below the target level under in-distribution calibration. Under distribution shift, transferred thresholds tend to become conservative when predictive performance improves, but can fail to control FDR when performance deteriorates. PPI-Caliper connects pre-trained interaction scores to explicit error targets and demonstrates why reliable biological discovery requires evaluating calibration alongside predictive accuracy.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}