potentialpaper

SIGCell: Sketched Isotropic Gaussianization of Cell Tokens for Transferable Cytometry Set Encoder

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:21 UTC · cbe2171055ec ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "NWJi0waxCm"
- }
- ],
- "title": "SIGCell: Sketched Isotropic Gaussianization of Cell Tokens for Transferable Cytometry Set Encoder",
- "authors": [],
- "abstract": "Cytometry measures dozens of protein markers on hundreds of thousands of single cells in a blood sample and is a standard tool for profiling the human immune system. However, even with the same marker panel, cytometry data varies greatly across institutions, so a model trained at one institution does not transfer smoothly to another. Existing pretrained cytometry encoders have largely been evaluated within the data they were trained on, or fine-tuned anew with labels for each downstream dataset, so whether a frozen encoder transfers to another institution remains open. We introduce a cell-SIGReg loss term that improves the transferability of set encoders, and present SIGCell (Sketched Isotropic Gaussianized Cell set encoder), a transferable cytometry set encoder trained with it. We identify a sample-context bias in masked set encoders: a cell's token depends strongly on which sample it is encoded with, which is associated with poor transfer of source-fitted cell-type read-outs across samples and institutions. Cell-SIGReg applies the sketched isotropic Gaussian regularizer to the cell tokens pooled over a mini-batch of samples, penalizing the separating structure between samples. We benchmark SIGCell against other pretrained cytometry encoders and classical baseline algorithms. On external datasets, SIGCell improves COVID-19 severity grading (balanced accuracy $.501$, against at most $.441$ for the other frozen representations) and transfers a source-fitted COVID-19 detection rule across institutions without target-cohort labels (AUROC $.949$ and $.995$ on two external datasets, first among ten models). Ablations and token-level analyses show that the gain is associated with a much weaker sample-context bias: the share of cell-token variance that lies between samples falls from $.93$--$.98$ to $.12$--$.24$. Cell-level latent regularization is thus a simple way to improve cross-institution transfer in cytometry set encoders.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "273a15f6-eb83-4209-84c6-59085822b4fb"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "SIGCell: Sketched Isotropic Gaussianization of Cell Tokens for Transferable Cytometry Set Encoder",
+ "authors": [],
+ "abstract": "Cytometry measures dozens of protein markers on hundreds of thousands of single cells in a blood sample and is a standard tool for profiling the human immune system. However, even with the same marker panel, cytometry data varies greatly across institutions, so a model trained at one institution does not transfer smoothly to another. Existing pretrained cytometry encoders have largely been evaluated within the data they were trained on, or fine-tuned anew with labels for each downstream dataset, so whether a frozen encoder transfers to another institution remains open. We introduce a cell-SIGReg loss term that improves the transferability of set encoders, and present SIGCell (Sketched Isotropic Gaussianized Cell set encoder), a transferable cytometry set encoder trained with it. We identify a sample-context bias in masked set encoders: a cell's token depends strongly on which sample it is encoded with, which is associated with poor transfer of source-fitted cell-type read-outs across samples and institutions. Cell-SIGReg applies the sketched isotropic Gaussian regularizer to the cell tokens pooled over a mini-batch of samples, penalizing the separating structure between samples. We benchmark SIGCell against other pretrained cytometry encoders and classical baseline algorithms. On external datasets, SIGCell improves COVID-19 severity grading (balanced accuracy $.501$, against at most $.441$ for the other frozen representations) and transfers a source-fitted COVID-19 detection rule across institutions without target-cohort labels (AUROC $.949$ and $.995$ on two external datasets, first among ten models). Ablations and token-level analyses show that the gain is associated with a much weaker sample-context bias: the share of cell-token variance that lies between samples falls from $.93$--$.98$ to $.12$--$.24$. Cell-level latent regularization is thus a simple way to improve cross-institution transfer in cytometry set encoders.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}