ERIA: An Instruction-Optimized Agent for Clinical EEG Reporting
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:21 UTC · 04fd6a50e7db ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "QMicLPmjE0"- }- ],- "title": "ERIA: An Instruction-Optimized Agent for Clinical EEG Reporting",- "authors": [],- "abstract": "Clinical EEG interpretation is substantially more complex than classifying short signal segments; it must assess technical quality, characterize background and behavioral states across long recordings, identify interictal and ictal abnormalities, reconcile uncertain evidence, and synthesize these findings into a clinically meaningful report. We introduce ERIA (EEG Reporting and Instruction-Optimized Agent), a locally deployable EEG interpretation framework that enables a single 27B language-model controller to analyze whole-recording EEGs by orchestrating specialized parametric and signal-processing tools. ERIA combines specialized tools for detecting background abnormality, sleep–wake states, seizure-like activity, and interictal epileptiform discharges with deterministic spectral, amplitude, symmetry, montage, and signal-quality analyses, covering multiple clinically relevant domains reflected in EEG reporting guidelines. Rather than relying on EEG-specific controller fine-tuning, a proprietary frontier model, or multi-agent orchestration, ERIA keeps the controller weights, specialist tools, and safety constraints fixed and optimizes only its natural-language analysis policy with GEPA (Genetic-Pareto), a reflective prompt optimizer, using feedback from expert-written EEG reports. Compared with the raw policy, GEPA substantially improves physician-aligned whole-recording report quality, while the resulting policy transfers to external EEG benchmarks. We evaluate performance on CerebraGloss-Bench short-segment clinical interpretation and BrainBench Foundational Analysis, where ERIA performs competitively with the models evaluated in the original benchmarks. These results show that carefully selected specialist tools and language-level policy optimization can extend the clinical and general EEG capabilities of a single locally executable model while preserving local inference, traceable tool use, and a comparatively simple deployment architecture.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "d87a1a49-6b31-4955-8596-395de1351445"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "ERIA: An Instruction-Optimized Agent for Clinical EEG Reporting",+ "authors": [],+ "abstract": "Clinical EEG interpretation is substantially more complex than classifying short signal segments; it must assess technical quality, characterize background and behavioral states across long recordings, identify interictal and ictal abnormalities, reconcile uncertain evidence, and synthesize these findings into a clinically meaningful report. We introduce ERIA (EEG Reporting and Instruction-Optimized Agent), a locally deployable EEG interpretation framework that enables a single 27B language-model controller to analyze whole-recording EEGs by orchestrating specialized parametric and signal-processing tools. ERIA combines specialized tools for detecting background abnormality, sleep–wake states, seizure-like activity, and interictal epileptiform discharges with deterministic spectral, amplitude, symmetry, montage, and signal-quality analyses, covering multiple clinically relevant domains reflected in EEG reporting guidelines. Rather than relying on EEG-specific controller fine-tuning, a proprietary frontier model, or multi-agent orchestration, ERIA keeps the controller weights, specialist tools, and safety constraints fixed and optimizes only its natural-language analysis policy with GEPA (Genetic-Pareto), a reflective prompt optimizer, using feedback from expert-written EEG reports. Compared with the raw policy, GEPA substantially improves physician-aligned whole-recording report quality, while the resulting policy transfers to external EEG benchmarks. We evaluate performance on CerebraGloss-Bench short-segment clinical interpretation and BrainBench Foundational Analysis, where ERIA performs competitively with the models evaluated in the original benchmarks. These results show that carefully selected specialist tools and language-level policy optimization can extend the clinical and general EEG capabilities of a single locally executable model while preserving local inference, traceable tool use, and a comparatively simple deployment architecture.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}