Update ICLR 2027 submission 55ESL48ES7: 1 note
@openreview[bot] · 2026-11-25 09:23 UTC · bb88f2919e15 ·
reviews/openreview/55esl48es7/notes/cczsa02s2g.json modified
+++ b/reviews/openreview/55esl48es7/notes/cczsa02s2g.json@@ -14,12 +14,12 @@"critical_weaknesses": "**W1. The method described in the paper does not match the released configuration.** In the README's canonical entry point (`run_pvp.sh` with `default.yaml`), both visual pins have weight 0, the pseudo-Huber field is used only in the first third of the blocks, the last block is trained with pure KL, which Table 1 presents as collapsing, and the pseudo-Huber scale is 0.5·RMS rather than the 0.25·RMS of Eq. 3. It is therefore unclear whether Table 2 was produced by the method described in §3, and the promised per-cell manifests are a comment-only stub.\n\n**W2. The headline gain cannot be attributed to the proposed objective.** The W2 baselines were run by the authors without a stated protocol, while PVP additionally uses the rotation stage, four times as many calibration images (4,096 vs. 1,024), finer activation granularity and QDrop. The only matched objective swap yields +0.64 / +0.28, whereas the rotation stage alone gives +5.61. Results for the same configuration also differ across tables (59.54, 59.21, 63.154, where even AdaRound reaches 62.729 in Table 10), and no variance is reported (Tables 2, 5, 10; Fig. 5b).","questions_for_authors": "1. Which exact configuration produced the main tables? Please explain the relation between the recommended entry point (pins off, depth-mixed objective, pure KL on the last block, c = 0.5) and the method of §3, and release the as-run per-cell configurations.\n2. In the main ImageNet comparison, are the calibration count, granularity, high-precision exceptions and rotation stage matched across methods, and how were the W2 baseline rows produced? Beyond absolute values and pseudo-Huber, how does d_j differ from LS-ViT's diagonal?\n3. Given that direct KL also has the worse *fit* metric (2.282 vs. 1.467 on DeiT-T), what supports the overfitting explanation rather than optimization difficulty — especially since PD-Quant, which also optimizes a prediction-difference KL, reaches 25.56 / 31.45 at W2A3?\n4. Since Table 5 states one 50-epoch linear-probe protocol for both arms, how do you explain CIFAR-100 Top-1 falling from 62.84 to 53.02 while retrieval improves by 3.38 after adding the rotation stage? Please also reconcile the conflicting entries above and state which are canonical.","flag_for_ethics_review": "No","details_of_ethics_concerns": "Not applicable",- "rating": 2,+ "rating": 3,"confidence": 4},"createdAt": "2026-10-20T15:32:48.697Z",- "modifiedAt": "2026-11-20T09:07:14.123Z",+ "modifiedAt": "2026-11-25T08:31:17.026Z","url": "https://openreview.net/forum?id=55ESL48ES7¬eId=CcZSA02s2G","license": "CC-BY-4.0"}