Four Cells Are Not the Same Dose: Size-Conditioned Spatial Lesions in Detection Transformers
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:23 UTC · 221bf1581a61 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "m7t5Ub0475"- }- ],- "title": "Four Cells Are Not the Same Dose: Size-Conditioned Spatial Lesions in Detection Transformers",- "authors": [],- "abstract": "A spatial lesion that removes four feature cells can erase most of a small object's footprint while barely affecting a large one. We test whether this mismatch changes conclusions drawn from decoder cross-attention in frozen DETR and Conditional DETR checkpoints. On a preregistered 4,000-image COCO holdout, the small-minus-large local-quality contrasts for four in-box versus four out-of-box cells are 0.02136 and 0.02325. When we instead remove the same 0.02 clean mean-head attention mass from each eligible query, both 95% image-bootstrap intervals fall inside the prespecified ±0.005 equivalence region. This low-dose result applies only to eligible GT-matched objects: the four-cell gate excludes 60.3% of candidate small objects. At an exploratory dose of 0.40, size contrasts rise again, so equal mass is not a general explanation of size sensitivity. Prediction-selected detector AP effects are small and differ from the GT-matched local estimand. An exploratory deformable sampling-footprint candidate improves small-object AP in an author-designated summary, but the baseline fails a prespecified feasibility gate and conflicting source records preclude a validated improvement claim. The practical contribution is a dose-aware spatial-ablation protocol that reports eligibility and the detector-level readout alongside query-level effects.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "7876918a-b428-4ffb-aa09-48ab9b5c08d3"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Four Cells Are Not the Same Dose: Size-Conditioned Spatial Lesions in Detection Transformers",+ "authors": [],+ "abstract": "A spatial lesion that removes four feature cells can erase most of a small object's footprint while barely affecting a large one. We test whether this mismatch changes conclusions drawn from decoder cross-attention in frozen DETR and Conditional DETR checkpoints. On a preregistered 4,000-image COCO holdout, the small-minus-large local-quality contrasts for four in-box versus four out-of-box cells are 0.02136 and 0.02325. When we instead remove the same 0.02 clean mean-head attention mass from each eligible query, both 95% image-bootstrap intervals fall inside the prespecified ±0.005 equivalence region. This low-dose result applies only to eligible GT-matched objects: the four-cell gate excludes 60.3% of candidate small objects. At an exploratory dose of 0.40, size contrasts rise again, so equal mass is not a general explanation of size sensitivity. Prediction-selected detector AP effects are small and differ from the GT-matched local estimand. An exploratory deformable sampling-footprint candidate improves small-object AP in an author-designated summary, but the baseline fails a prespecified feasibility gate and conflicting source records preclude a validated improvement claim. The practical contribution is a dose-aware spatial-ablation protocol that reports eligibility and the detector-level readout alongside query-level effects.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}