potentialpaper

Four Cells Are Not the Same Dose: Size-Conditioned Spatial Lesions in Detection Transformers

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:23 UTC · 221bf1581a61 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "m7t5Ub0475"
- }
- ],
- "title": "Four Cells Are Not the Same Dose: Size-Conditioned Spatial Lesions in Detection Transformers",
- "authors": [],
- "abstract": "A spatial lesion that removes four feature cells can erase most of a small object's footprint while barely affecting a large one. We test whether this mismatch changes conclusions drawn from decoder cross-attention in frozen DETR and Conditional DETR checkpoints. On a preregistered 4,000-image COCO holdout, the small-minus-large local-quality contrasts for four in-box versus four out-of-box cells are 0.02136 and 0.02325. When we instead remove the same 0.02 clean mean-head attention mass from each eligible query, both 95% image-bootstrap intervals fall inside the prespecified ±0.005 equivalence region. This low-dose result applies only to eligible GT-matched objects: the four-cell gate excludes 60.3% of candidate small objects. At an exploratory dose of 0.40, size contrasts rise again, so equal mass is not a general explanation of size sensitivity. Prediction-selected detector AP effects are small and differ from the GT-matched local estimand. An exploratory deformable sampling-footprint candidate improves small-object AP in an author-designated summary, but the baseline fails a prespecified feasibility gate and conflicting source records preclude a validated improvement claim. The practical contribution is a dose-aware spatial-ablation protocol that reports eligibility and the detector-level readout alongside query-level effects.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "7876918a-b428-4ffb-aa09-48ab9b5c08d3"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "Four Cells Are Not the Same Dose: Size-Conditioned Spatial Lesions in Detection Transformers",
+ "authors": [],
+ "abstract": "A spatial lesion that removes four feature cells can erase most of a small object's footprint while barely affecting a large one. We test whether this mismatch changes conclusions drawn from decoder cross-attention in frozen DETR and Conditional DETR checkpoints. On a preregistered 4,000-image COCO holdout, the small-minus-large local-quality contrasts for four in-box versus four out-of-box cells are 0.02136 and 0.02325. When we instead remove the same 0.02 clean mean-head attention mass from each eligible query, both 95% image-bootstrap intervals fall inside the prespecified ±0.005 equivalence region. This low-dose result applies only to eligible GT-matched objects: the four-cell gate excludes 60.3% of candidate small objects. At an exploratory dose of 0.40, size contrasts rise again, so equal mass is not a general explanation of size sensitivity. Prediction-selected detector AP effects are small and differ from the GT-matched local estimand. An exploratory deformable sampling-footprint candidate improves small-object AP in an author-designated summary, but the baseline fails a prespecified feasibility gate and conflicting source records preclude a validated improvement claim. The practical contribution is a dose-aware spatial-ablation protocol that reports eligibility and the detector-level readout alongside query-level effects.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}