potentialpaper

EAGLE: Grounding Multimodal LLM Judges for AI-Generated Image Assessment via Evidence Anchors

Update ICLR 2027 submission Qask3lw679: 1 note

@openreview[bot] · 2026-11-25 02:28 UTC · e190d913f4eb ·

Evidence

reviews/openreview/qask3lw679/notes/sepdg4eghu.json modified

+++ b/reviews/openreview/qask3lw679/notes/sepdg4eghu.json
@@ -13,12 +13,12 @@
"critical_strengths": "1. The cross-dataset results are strong and hold against a trained same-backbone baseline. EAGLE has the best SRCC and PLCC in every column of Table 2, which covers both transfer directions and both criteria. The more informative comparison is the LoRA-adapted holistic baseline in Table 5, which shares the frozen backbone and the supervision; EAGLE beats it on both criteria in both transfer directions. This supports an improvement in transfer between the two datasets tested.\n2. The ablations cover components, losses, and query structure. Table 5 separates the two branches, removes anchor interaction, removes structured queries, and trains criteria individually; Table 3 separates the ranking and diversity losses. Appendix C.1 reports trainable parameters and per-sample training and inference time, so the cost of the added module is visible.",
"critical_weaknesses": "1. The paper does not show that the anchors cause each criterion to rely on its intended evidence.\n- Table 4 perturbs only EAGLE; no trained baseline or ablated variant is tested under the same interventions.\n- Shared queries interact with text even for visual criteria, and Equations 6 and 7 read final-layer MLLM states, so evidence sources are not strictly separated.\n- Figure 4 is a qualitative example, and Table 5 shows predictive gains rather than which evidence the scores rely on.\n2. Run-to-run variance is unreported, and the cross-dataset gain stated in Section 4.2 does not match Table 2.\n- Tables 1-5 report no run-to-run variance, although several margins are 0.1-0.2 points (e.g., HPDv2 SRCC 85.3 vs. 85.1).\n- Section 4.2 reports gains of \"up to 7.4 SRCC and 8.8 PLCC\" over M3-AGIQA, but Table 2 gives maxima of 8.1 and 11.5.",
"questions_for_authors": "1. If the Table 5 LoRA baseline receives the Table 4 interventions with the same inputs and instructions, is its criterion-specific pattern weaker than EAGLE's?\n2. How large is run-to-run variation relative to the 0.1-0.2-point margins in Tables 1-5?\n3. Do the AGIQA-3K and AIGCIQA2023 baseline numbers taken from the original works (Section 4.1) use the same test splits as EAGLE?\n4. Which Table 2 entries produce the \"up to 7.4 SRCC and 8.8 PLCC\" gains reported in Section 4.2?\n5. What values are used for σ (Equation 3), δ (Equation 12), and the similarity function in Equation 13?",
"flag_for_ethics_review": "No",
- "rating": 2,
+ "rating": 3,
"confidence": 3
},
"createdAt": "2026-10-19T15:42:39.174Z",
- "modifiedAt": "2026-11-18T10:05:22.227Z",
+ "modifiedAt": "2026-11-25T01:43:57.790Z",
"url": "https://openreview.net/forum?id=Qask3lw679&noteId=SepdG4eghu",
"license": "CC-BY-4.0"
}