Neural Conditional Simulation for PDE Refinement
Import ICLR 2027 submission aP806kHcn2: 25 notes
@openreview[bot] · 2026-11-22 21:22 UTC · 574291fcd71a
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,19 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "aP806kHcn2"+ }+ ],+ "title": "Neural Conditional Simulation for PDE Refinement",+ "authors": [],+ "abstract": "Refining a cheap coarse PDE solution to high fidelity is a conditional\nsimulation problem, not a regression one. Under squared-error loss the optimal\npredictor is the conditional mean, which by the law of total variance discards\nall conditional variability and so cannot serve as a realization of the fine\nfield. For Gaussian fields the answer is classical. Kriging supplies the\nconditional mean, and Matheron's construction adds an innovation drawn from\nthe Schur-complement covariance to produce an exact sample in one pass. The\nfields that matter in practice, such as turbulence, stochastically forced\ndynamics, and precipitation, break these assumptions with innovations that\nare input-dependent, heteroscedastic, and heavy-tailed. We introduce Neural Conditional Simulation (NCS), which keeps the\nclassical recipe but learns the innovation. NCS is initialized at the exact\nGaussian simulator, trained end to end with strictly proper scoring rules, and\nsamples through a coarse-to-fine cascade at one network pass per level.\nBecause the Gaussian simulator is embedded as a zero-correction fallback and\nreported as a baseline, every result isolates the nonlinear\nconditional-simulation gain, which highlights the improvement that learning adds beyond exact\nGaussian conditioning. On the near-Gaussian Allen-Cahn and Navier-Stokes\nbenchmarks, this gain is small, as expected, and NCS matches the calibration\nof the best classical baseline to within a few percent. On the GARD-LENS\nprecipitation ensemble, where the Gaussian assumptions break, NCS is the only\nmethod that is globally variance-calibrated at competitive CRPS and spectral error (Fortin-corrected\n$\\sigma/s = 0.96$): across $132$ noise-schedule settings of the diffusion\nbaselines, every setting with $\\sigma/s \\ge 0.9$ has higher CRPS and more than twice\nthe spectral error. The heavy precipitation tail, however, is under-reproduced by NCS\ntrained with the energy score ($\\kappa/\\kappa_{\\mathrm{data}} = 0.17$); tuned\nconsistency models reach it only while under-dispersed ($\\sigma/s \\le 0.57$). Our supply-versus-reach diagnostic\nattributes this deficit to the objective rather than the source. A scale-free\nflatness term closes $93\\%$ of an analogous deficit on a controlled system. On GARD-LENS, \nwhere the deficit depends on amplitude, an amplitude-conditional objective recovers most of \nthe tail while keeping calibration and spectrum within their guards. With the same backbone and no\nmore parameters than CorrDiff, NCS matches multi-step diffusion baselines such as\nEDM and CorrDiff in accuracy and proper score while using two network passes\ninstead of $35$ which reduces per-member wall-clock time by $17$-$36\\times$.",+ "year": 2027,+ "venue": "ICLR 2027 (under review)",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://potentialpaper.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/ap806khcn2/forms.json added
+++ b/reviews/openreview/ap806khcn2/forms.json@@ -0,0 +1,183 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "additional_comments_on_reviewer_discussion",+ "label": "Reviewer discussion",+ "type": "text"+ },+ {+ "key": "recommendation",+ "label": "Recommendation",+ "type": "choice"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "soundness",+ "presentation",+ "informativeness"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "soundness",+ "label": "Soundness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "presentation",+ "label": "Presentation",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "informativeness",+ "label": "Informativeness",+ "type": "score",+ "min": 1,+ "max": 3+ },+ {+ "key": "paper_summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "critical_strengths",+ "label": "Strengths",+ "type": "text"+ },+ {+ "key": "critical_weaknesses",+ "label": "Weaknesses",+ "type": "text"+ },+ {+ "key": "questions_for_authors",+ "label": "Questions for the authors",+ "type": "text"+ },+ {+ "key": "flag_for_ethics_review",+ "label": "Flag for ethics review",+ "type": "choice",+ "omitWhen": [+ "No",+ "No ethics review needed."+ ]+ },+ {+ "key": "details_of_ethics_concerns",+ "label": "Ethics concerns",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/237ugfwbnl.json added
+++ b/reviews/openreview/ap806khcn2/notes/237ugfwbnl.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "237UGfWbNL",+ "replyTo": "apq8GBfPyf",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Q1: Why is this combination reasonable beyond being correct, and what theoretical advantage does it give?**\n\nThe combination is reasonable because each component removes a part of the problem that would otherwise have to be learned, and the theory states which part. The advantages are structural, each following from Section 4, with the measured effect size added where reported. They concern what is supplied and where training starts, not learning rates.\n\n**1. Training starts at the classical solution, and the model class contains it.** Because $g_\\theta$ is initialized at the identity, Gaussian conditional simulation (GCS) is the initial point of NCS and a member of its model class. The NCS class's best population energy score is therefore no worse than GCS's. For jointly Gaussian fields with exact covariance, GCS is the exact conditional law (Prop. 2) and hence the minimizer of any strictly proper score (Cor. 3), so population training has no incentive to leave it. More generally, with the energy score of Eq. 4 and finite first moments, the excess population risk at initialization is exactly $\\frac{1}{2} D_E(P,Q)$, averaged over conditions. Here $P$ is the true conditional law, $Q$ its Gaussian approximation, and\n\n$$\nD_E(P,Q)=2\\mathbb{E}\\lVert X-Y\\rVert-\\mathbb{E}\\lVert X-X'\\rVert-\\mathbb{E}\\lVert Y-Y'\\rVert\n$$\n\nis the energy distance, with $X,X'$ and $Y,Y'$ independent draws from $Q$ and $P$. A white-noise generator may contain Matheron's sampler in its class, but its initialization does not place it there. Because GCS is reported in every table, any departure from this starting point is visible.\n\n**2. The affine part does not have to be learned.** By Lemma 1, the innovation left after the kriging mean is uncorrelated with the condition. The conditional structure that remains for the network is the non-affine mean $m(c) - m_{\\mathrm{lin}}(c)$ (Eq. 12) and the higher-order, condition-dependent shape of the innovation. Everything an affine map explains is supplied in closed form, without gradient training; a sampler without this stage must learn it too. Lemma 2 gives its size: a source fitted to the marginal residual over-disperses by exactly $\\mathrm{Cov}(m_{\\mathrm{lin}}(c))$. We measure this as a variance excess of 2.08× on weakly conditioned Navier–Stokes, 1.77× on Burgers and 1.35× on Allen–Cahn (Appendix E.2.1).\n\n**3. The second-order structure is in place before training.** The source carries the estimated Schur-complement spectrum of the innovation (Eq. 22). The untrained model therefore has the right spectrum and spread for Gaussian fields, up to estimation error and the stationary approximation. This matters because the learned transport moves the spectrum little in our experiments. In the factorial of Table 12, replacing the affine transport with the full network changes logPSD by less than 0.2, while fitting the source reduces it from 1.3–1.7 to 0.1–0.5.\n\n**4. Deficits can be attributed to a component.** The kriging mean, the source and the transport act primarily on different quantities: the affine mean, the second-order law of the innovation, and the condition-dependent remainder (Lemma 1). A deficit can therefore be traced to a component, enabling the supply/reach protocol. In a monolithic generator, a wrong spectrum or light tail cannot be so assigned.\n\n**5. Relation to the theory of energy-score training.** The energy distance is the maximum mean discrepancy of a distance-induced kernel (Sejdinovic et al., 2013), so energy-score training is minimum-MMD estimation. Consistency is established for minimum-MMD estimators and scoring-rule-trained generative networks under the conditions stated there (Briol et al., 2019; Pacchiardi et al., 2024). What NCS adds concerns the approximation side. The excess score of a fitted model splits into an estimation term and an approximation term, the gap between the best model in the class and the true law. Because GCS lies in the NCS class, the approximation term is at most the GCS gap from point 1, $\\frac{1}{2} D_E(P_c,Q_c)$ averaged over conditions. It is zero for Gaussian fields, and NCS attains this bound at initialization.\n\nThe measurable consequence of (1) and (2) is that the value of learning is reported, not assumed. Every table contains the zero-learning sampler as a paired baseline. The gain is small where the field is near-Gaussian (CRPS 0.425 → 0.409 on Allen–Cahn) and large where it is not (2.460 → 1.571 on GARD-LENS).\n\nThese statements concern the identity initialization and model class, with covariances estimated under the stationary approximation. We would be glad to hear whether this addresses the concern.\n\nReferences: Sejdinovic et al. (2013), Equivalence of distance-based and RKHS-based statistics in hypothesis testing. Briol et al. (2019), Statistical inference for generative models with maximum mean discrepancy. Pacchiardi et al. (2024), Probabilistic forecasting with generative networks via scoring rule minimization."+ },+ "createdAt": "2026-11-16T13:10:15.023Z",+ "modifiedAt": "2026-11-16T13:10:15.023Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=237UGfWbNL",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/3q5l5g5ntw.json added
+++ b/reviews/openreview/ap806khcn2/notes/3q5l5g5ntw.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3Q5l5g5NTw",+ "replyTo": "hg2tZqYNm3",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 2/2",+ "comment": "> *Q2: How is the common coarse condition built? Sensitivity to bias in independently generated coarse inputs?*\n\nWe will describe it more precisely in Appendix D.1. For each day, the condition is the ensemble mean of the high-resolution members, block-averaged by $4\\times$ ($128^2 \\rightarrow 32^2$). The same condition is used for all members and by every method. Data are split by day, so no test day is seen during training. Two consequences, which we will state in Sec. 4, Appendix D.1 and the limitations:\n\n- The condition is shared across members, so all between-member variability must be generated by the model. The task is therefore conditional reconstruction given a consistent coarse field.\n- Robustness to coarse-model bias is untested on GARD-LENS, because the dataset has no independently produced coarse field. On our synthetic test cases, the coarse condition is a separate noise-free solve on the coarse grid, not a coarsening of the fine members, so those results already exercise an independent coarse solve.\n\nAs a controlled sensitivity test we offer a condition-member mismatch sweep on Navier-Stokes. Our Navier-Stokes simulator allows us to set how far the members' large scales drift from the condition. We sweep it from the training value ($\\tau = 1$) through weaker settings ($\\tau = 4, 16$) to fully free, and add one setting that is similar to GARD-LENS. All settings share the same random seeds, so the conditions are identical across settings. The members differ in their large scales and, slightly, in their fine-scale statistics; in particular, power in the finest resolved band is up to about 15% higher when free. We take the models trained on the current dataset and evaluate them, without retraining, on every setting. This measures how a deployed model responds to a coarse input that does not match the members it was trained against. The mismatch $m$ is the relative distance between each member's coarsened large scales and the test conditions, which gives the sweep a model-independent axis.\n\nES (mean over 3 seeds; $\\sigma/s$ in parentheses)\n\n| Setting | $m$ | NCS | CorrDiff | EDM | Consistency | GCS | PNO |\n|---|:---:|---:|---:|---:|---:|---:|---:|\n| GARD-style | 0.14 | 310.8 (0.98) | 309.0 (1.00) | 310.7 (1.00) | 310.5 (1.02) | 312.4 (1.01) | 336.6 |\n| $\\tau=1$ | 0.19 | 312.6 (0.97) | 310.9 (1.00) | 312.8 (0.99) | 312.9 (0.93) | 314.8 (1.00) | 341.6 |\n| $\\tau=4$ | 0.39 | 345.2 (0.89) | 342.9 (0.91) | 343.7 (0.91) | 345.4 (0.87) | 344.8 (0.92) | 374.3 |\n| $\\tau=16$ | 0.50 | 369.7 (0.83) | 367.0 (0.85) | 367.1 (0.86) | 369.6 (0.82) | 367.7 (0.86) | 398.5 |\n| free | 0.54 | 380.9 (0.81) | 378.1 (0.83) | 378.0 (0.83) | 380.9 (0.78) | 378.4 (0.84) | 409.8 |\n\nThe table shows that all methods degrade by the same amount. From $\\tau = 1$ to free, ES rises by 20.0-21.9% for every arm including GCS (NCS +21.9%, Consistency +21.7%, CorrDiff +21.6%, EDM +20.8%, GCS +20.2%, PNO +20.0%), and $\\sigma/s$ falls by 16-17% for all. The degradation is graceful, and no learned method is disproportionately fragile when the coarse input stops matching the members. Since the conditions are identical across settings, a frozen model sees the same input and is scored against different targets, so the rise reflects both the condition's loss of information and a small shift in the members' fine-scale statistics. Furthermore, we are generating a precipitation dataset with independently simulated coarse fields. Unfortunately, this requires substantial GPU resources and is not yet finished, so we cannot report results from it in this rebuttal.\n\n`[REVISION]` We state clearly construction and consequences in Sec. 4, Appendix D.1 and the limitations. Additionally, we add the sweep to the appendix with the framing above."+ },+ "createdAt": "2026-11-12T08:15:19.966Z",+ "modifiedAt": "2026-11-12T08:15:19.966Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=3Q5l5g5NTw",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/3uadlnnpzs.json added
+++ b/reviews/openreview/ap806khcn2/notes/3uadlnnpzs.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3uaDlNNPZS",+ "replyTo": "M1LKWDMUp4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 2/5",+ "comment": "> *Q1b, Q1c. Speedup at the best validated budgets; timing on small vs. large Navier-Stokes.*\n\nThe $17$-$35\\times$ figure is at the default schedule (35 NFE). The budget sweep shows that EDM reaches its own quality floor at about 9-11 NFE on Allen-Cahn and Navier-Stokes, and its best-CRPS GARD-LENS setting uses 17 NFE (Table 19). We therefore define the matched-quality budget as the smallest budget at which the baseline reaches its own best score. Measured per-member latency at those budgets, on the same GPU and in the same session:\n\n| System | NCS (ms) | EDM, validated budget: ms (NFE) | Speedup | EDM, 35 NFE: ms | Speedup |\n|---|---:|---:|---:|---:|---:|\n| Allen-Cahn | 0.86 | 3.76-4.55 (9-11) | $4.4$-$5.3\\times$ | 14.36 | $16.7\\times$ |\n| Navier-Stokes $32 \\rightarrow 128$ | 0.94 | 6.76-8.25 (9-11) | $7.2$-$8.8\\times$ | 26.15 | $27.8\\times$ |\n| Navier-Stokes $64 \\rightarrow 256$ | 3.44 | 24.27-29.65 (9-11) | $7.1$-$8.6\\times$ | 94.25 | $27.4\\times$ |\n| GARD-LENS | 0.74 | 12.72 (17) | $17.2\\times$ | 26.19 | $35.3\\times$ |\n\nCorrDiff costs the same as EDM within 1% at every budget. EDM's cost scales almost exactly linearly with NFE (fixed per-sample overhead is below 0.1 ms), so the validated-budget speedups are roughly the 35-NFE figures scaled by the step ratio.\n\n`[REVISION]` We provide the validated-budget speedup as the headline, with the 35-NFE numbers secondary.\n\n> *Q2. Batch size in the threshold-weighted ablation.*\n\nThank you for catching this. The threshold-weighted arm was fine-tuned end to end at batch 1 because its tail-weight dose was calibrated at that batch; changing the batch shifts the effective dose by about 20% and would have required recalibration. The energy-score control and the other arms ran at batch 4. Appendix G wrongly states batch 1 for the energy-score stage. Architecture, source, pretraining, epochs, ensemble size and learning rate were identical. The Table 13 caption (\"objective-only changes\") is therefore inaccurate and will be corrected, as will Appendix G.\n\nTo remove the confound we retrained the energy-score arm with the threshold-weighted arm's exact recipe, with only the threshold terms deleted: batch 1, the same pretraining and fine-tuning epochs, learning rate, ensemble size, source and number of optimizer updates. This is a full retrain, three seeds. All nine runs (three arms $\\times$ three seeds) are scored on byte-identical conditions and targets.\n\n**Panel A**\n\n| Arm | ES | CRPS | $\\sigma/s$ | logPSD |\n|---|---:|---:|---:|---:|\n| ES, batch 4 | 312.6 [311.3, 313.8] | 0.969 [0.965, 0.973] | 0.973 [0.969, 0.977] | 0.364 [0.341, 0.392] |\n| ES, batch 1 (matched control) | 312.9 [311.6, 314.2] | 0.970 [0.966, 0.974] | 0.969 [0.965, 0.973] | 0.342 [0.338, 0.348] |\n| twES, batch 1 | 312.8 [311.5, 314.1] | 0.970 [0.966, 0.974] | 0.973 [0.969, 0.977] | 0.208 [0.201, 0.217] |\n\n**Panel B: tail (standardized lag increments; data value in the last row)**\n\n| Arm | $\\kappa_1$ | $\\kappa_2$ | $\\Delta\\zeta_4$ | $q_{99}$ | $q_{99.9}$ |\n|---|---:|---:|---:|---:|---:|\n| ES, batch 4 | 6.49 [6.11, 6.84] | 3.63 [3.58, 3.69] | $-0.119$ [$-0.128$, $-0.112$] | 2.00 [1.95, 2.04] | 2.87 [2.79, 2.94] |\n| ES, batch 1 (matched control) | 6.18 [5.98, 6.43] | 3.54 [3.50, 3.60] | $-0.102$ [$-0.111$, $-0.096$] | 2.02 [2.00, 2.03] | 2.88 [2.85, 2.91] |\n| twES, batch 1 | 4.79 [4.63, 4.95] | 4.04 [3.91, 4.13] | $-0.334$ [$-0.368$, $-0.303$] | 3.04 [3.01, 3.06] | 4.24 [4.18, 4.28] |\n| **Data** | 4.16 | 4.02 | $-0.341$ | 2.90 | 3.99 |\n\n$\\kappa_2$ is the lag-2 increment kurtosis, $\\Delta\\zeta_4$ the fourth-order structure-function exponent departure, and $q_{99}$/$q_{99.9}$ the far quantiles of the standardized increments.\n\nAt batch 1, the energy-score arm behaves like the batch-4 arm on every tail statistic: its $q_{99}$ is 2.02 against 2.00, with overlapping intervals, and both are far from the data's 2.90. The threshold-weighted arm, trained at the same batch, is clearly separated from both, by 47 times the standard deviation of the difference on $q_{99}$ and by 7-14 times on $\\kappa_2$ and $\\Delta\\zeta_4$. The tail gain therefore comes from the objective, not from the batch.\n\nThe same holds for the spectrum. logPSD barely moves between batch 4 and batch 1 (0.364 vs. 0.342, overlapping), while the threshold-weighted arm reaches 0.208. Since the comparison is now matched, we restore the attribution of the spectral improvement to the threshold-weighted score. None of this costs accuracy: ES, CRPS and $\\sigma/s$ overlap across all three arms.\n\n`[REVISION]` We correct the Table 13 caption and Appendix G."+ },+ "createdAt": "2026-11-12T08:21:51.469Z",+ "modifiedAt": "2026-11-12T08:21:51.469Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=3uaDlNNPZS",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/7dq1dpbge2.json added
+++ b/reviews/openreview/ap806khcn2/notes/7dq1dpbge2.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "7DQ1DpBGe2",+ "replyTo": "M1LKWDMUp4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of new results for your review",+ "comment": "Dear Reviewer yLXT,\n\nThank you again for your detailed review. You listed several requests that could change your assessment. We addressed each with new experiments (Parts 1 to 5 below), and the results strengthen the paper's main claims:\n\n- Retrained baselines (Q1): with standardized targets and validation-selected sampling, the diffusion baselines become much better calibrated, and we report the comparison as a tradeoff. NCS stays closest to calibration (σ/s 0.98 vs. 0.90 for tuned EDM) with a single network pass.\n- Speedup at validated budgets (Q1b, Q1c): at each baseline's own best budget, NCS is 4–5× faster on Allen–Cahn, 7–9× on Navier–Stokes (including the 64 → 256 resolution of the main table) and 17× on GARD-LENS.\n- Matched-batch control (Q2): at identical batch size, the energy-score arm keeps its light tail (q99 2.02, data 2.90), while the threshold-weighted objective reaches 3.04. The tail and spectral gains come from the objective, not the batch.\n- Full test set (Q3): on all 128 GARD-LENS test conditions, the energy-score ordering of all methods is unchanged.\n- Conditional extremes (Q4): NCS places heavy rain more accurately (FSS 0.87 vs. 0.45–0.72 for the diffusion baselines) and has the best wet-pixel coverage (0.84 vs. 0.68–0.74).\n\nAs the discussion period ends on 18 November, we would be grateful to hear whether these results address your concerns and have changed your assessment of the paper. If they have, we would appreciate it if you would consider updating your rating. We are happy to clarify anything that remains open."+ },+ "createdAt": "2026-11-17T09:43:42.818Z",+ "modifiedAt": "2026-11-17T09:43:42.818Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=7DQ1DpBGe2",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/apq8gbfpyf.json added
+++ b/reviews/openreview/ap806khcn2/notes/apq8gbfpyf.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "apq8GBfPyf",+ "replyTo": "Zla60i4eM9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer HC6i",+ "content": {+ "comment": "I still do not understand what makes this combination reasonable beyond the fact that it is mathematically correct. The theory seems to show that the parts can work together, but it does not clearly explain why this combination works better than existing methods, or what clear gain it gives in learning efficiency. Could the authors explain what theoretical advantages come from putting these parts together, beyond the experimental results reported in the paper?"+ },+ "createdAt": "2026-11-14T18:06:58.102Z",+ "modifiedAt": "2026-11-14T18:06:58.102Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=apq8GBfPyf",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/aqdhf7ie29.json added
+++ b/reviews/openreview/ap806khcn2/notes/aqdhf7ie29.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "aQDhF7IE29",+ "replyTo": "NPmaRewird",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer HC6i",+ "content": {+ "comment": "The proposed protocol makes the difference clearer, but I am still not sure how the authors can conclude that a deficit is reach-limited. If the tested source and transport variants do not help, this does not mean the objective is necessarily the problem. The model may not have enough capacity to represent the required structure, or training may fail to learn it. This seems relevant to the limitation mentioned in W4. For GARD-LENS, showing that a different objective improves the tail does not by itself prove that the original deficit is reach-limited. Could the authors clarify how they tell an objective limitation apart from limits of the model and its training?"+ },+ "createdAt": "2026-11-14T18:10:40.698Z",+ "modifiedAt": "2026-11-14T18:10:40.698Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=aQDhF7IE29",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/chmniuxjhu.json added
+++ b/reviews/openreview/ap806khcn2/notes/chmniuxjhu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "chMniUxjHU",+ "replyTo": "gYSGyrbM29",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Q2: GARD-LENS numbers in the rebuttal differ from Table 1\n\nThese differences come from the change of evaluation set stated at the top of our general response. They do not come from new experiments or from a change in the evaluation protocol. Table 1, Table 15 and Table 19 were scored on 64 of the 128 GARD-LENS test conditions: a random subset fixed by the split seed before any model was trained, identical for every arm and seed. For the rebuttal we re-sampled the same checkpoints, with the same samplers and ensemble size, on all 128 test conditions. Our answer to yLXT Q3 reports both evaluations side by side.\n\n| | Table 1 (64 conditions) | Re-sampled, same 64 conditions | All 128 conditions |\n|---|---|---|---|\n| NCS, ES | 473.7 | 474.4 [441.3, 507.7] | 460.7 [438.6, 483.3] |\n| PNO, ES | 476.2 | 476.2 [443.4, 508.9] | 462.4 [440.2, 485.8] |\n| NCS, CRPS | 1.588 | 1.590 [1.472, 1.708] | 1.571 [1.487, 1.655] |\n| PNO, CRPS | 1.612 | 1.610 [1.490, 1.727] | 1.592 [1.514, 1.681] |\n\nBrackets are 95% condition-bootstrap intervals. The middle column uses new ensemble draws on the Table 1 conditions and differs from Table 1 only by sampling noise.\n\nThe ± values in Table 1 are standard deviations over three seeds, not uncertainty over conditions, which is why the shift may look large (for the kurtosis ratio: ± 0.030 on 64 conditions, ± 0.04 on 128). Over conditions, the intervals are wide, and the 64- and 128-condition values lie well within each other's intervals.\n\nThe difference is not statistically significant. Among 10,000 random 64-condition subsets of the test set, 23.9% deviate from the 128-condition mean by at least as much as the Table 1 subset on the energy score (p = 0.239), and 65.1% on CRPS (p=0.651). The Table 1 subset is a typical draw from the test set.\n\nTwo further checks support this. First, all arms shift by the same amount (ES −13.7 for NCS, −13.8 for PNO), so the gap between methods is unchanged. Second, recomputed on the original 64 conditions, the stored predictions reproduce Table 1 exactly (NCS ES 473.7, CRPS 1.588). The energy-score ordering of all principal arms is the same on both sets."+ },+ "createdAt": "2026-11-16T13:15:37.612Z",+ "modifiedAt": "2026-11-16T13:15:37.612Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=chMniUxjHU",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/dirzdqoqpz.json added
+++ b/reviews/openreview/ap806khcn2/notes/dirzdqoqpz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "diRZdqoQpz",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "General response (all reviewers)",+ "comment": "We thank the reviewers for careful and constructive reviews, and since rebuttal time is short, we offer an optional, anonymized 8-minute video recap of NCS ([link](https://osf.io/9wqxy/overview?view_only=d6aa818868cc4c23bd330384f0b39423)) for anyone who would like a quick refresher on the method before reading our responses. \n\nThree concerns were shared, and we address each with new evidence below and in the individual responses. Unless stated otherwise, all GARD-LENS numbers are now on all 128 test conditions, and kurtosis ratios are at lag 2.\n\n1. The precipitation tail (eL2g, yLXT). Default NCS is calibrated in spread ($\\sigma/s$ 0.98) and competitive on CRPS and spectrum. However, it reproduces only 21% of the data's increment kurtosis. The cause is the objective. The energy score is dominated by the bulk of the distribution, and on GARD-LENS the deficit depends on intensity: the ensemble is $3.8\\times$ over-dispersed at low rain rates and $0.87\\times$ in the tail. We changed only the objective. Amplitude-conditional terms raise the kurtosis ratio to 0.70 (L2) and 0.84 (L4) with ES and spread unchanged. L4 also more than halves logPSD ($0.131 \\rightarrow 0.058$), and L2 improves CRPS ($1.571 \\rightarrow 1.554$).\n\n2. Construction of the GARD-LENS condition (eL2g, yLXT). The coarse condition is the block-averaged ensemble mean of the same high-resolution members that are refined. The task is therefore conditional reconstruction given a consistent coarse field. We state this in Sec. 4, Appendix D.1 and the limitations, and we restrict the precipitation claims to this setting. We also ran a condition–member mismatch sweep on Navier–Stokes (eL2g Q2). As the coarse input stops matching the members, every method degrades by a similar 20–22% in ES, including the untrained Gaussian anchor. An independently conditioned precipitation benchmark is in preparation but is not part of this rebuttal.\n\n3. Clarity of the contribution (HC6i, yLXT). We add a short statement of what NCS adds over classical conditional simulation and over learned refiners. We also define the supply/reach taxonomy operationally as a three-step diagnostic protocol (HC6i W6), and we move design detail to the appendix.\n\nNew evidence\n\n- Retrained diffusion baselines (yLXT Q1). We retrained EDM, CorrDiff and Consistency on GARD-LENS with a standardized target, using three seeds. Sampling settings were selected on validation conditions by a rule fixed in advance. This removes most of the baselines’ under-dispersion (EDM $\\sigma/s$ $0.44 \\rightarrow 0.90$). Tuned EDM is better than NCS on CRPS and spectral structure. NCS keeps the lower energy score, spread closer to one, and, with L4, the best tail among learned methods. We withdraw the claim that NCS is the only calibrated method on GARD-LENS, and we present the comparison as a quality–latency tradeoff.\n- Latency at validated budgets (yLXT Q1b/c). At each baseline’s best validated sampling budget, NCS is $4.4$-$5.3\\times$ faster than EDM on Allen-Cahn, $7$-$9\\times$ on Navier-Stokes and $17\\times$ on GARD-LENS. At the default 35 steps the figures are $17$-$35\\times$. The validated-budget figures become the headline.\n- Matched-batch control (yLXT Q2). We retrained the energy-score arm with the threshold-weighted arm’s exact recipe, at batch 1. Its tail and spectrum are unchanged, so both gains come from the objective, not the batch.\n- All principal GARD-LENS rows re-sampled on all 128 test conditions (yLXT Q3). The energy-score ordering is unchanged. On CRPS, Consistency moves ahead of NCS+L2, and PNO becomes slightly over-dispersed ($\\sigma/s$ 1.04).\n- Conditional extreme diagnostics (yLXT Q4). We report exceedance reliability, Brier score, coverage, fractions skill and object statistics, with uncertainty, on all 128 test conditions."+ },+ "createdAt": "2026-11-12T08:02:18.026Z",+ "modifiedAt": "2026-11-12T08:02:18.026Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=diRZdqoQpz",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/eabnv7zied.json added
+++ b/reviews/openreview/ap806khcn2/notes/eabnv7zied.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "EAbnv7ZIed",+ "replyTo": "M1LKWDMUp4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 5/5",+ "comment": "> *Q4 (continued).*\n\n| Model | $\\text{Brier}_{>20,\\,\\text{high}}$ | 90% cov. (wet) | $W_1$ 99th pct. | $\\text{FSS}_{20,\\,n=9}$ | obj. count ratio$_{>20}$ | obj. $W_1$ log-area$_{>20}$ |\n|---|---:|---:|---:|---:|---:|---:|\n| NCS | 0.0714 [0.0682, 0.0744] | 0.841 [0.835, 0.847] | 6.42 [5.95, 6.90] | 0.868 [0.858, 0.878] | 0.799 [0.749, 0.850] | 0.253 [0.232, 0.274] |\n| NCS+L2 | 0.0713 [0.0681, 0.0743] | 0.830 [0.824, 0.837] | 6.38 [5.91, 6.86] | 0.869 [0.859, 0.879] | 0.803 [0.754, 0.854] | 0.259 [0.239, 0.279] |\n| NCS+L4 | 0.0714 [0.0681, 0.0744] | 0.832 [0.826, 0.839] | 6.37 [5.89, 6.87] | 0.867 [0.857, 0.877] | 0.678 [0.635, 0.721] | 0.332 [0.309, 0.354] |\n| EDM | 0.0746 [0.0710, 0.0779] | 0.698 [0.693, 0.703] | 12.87 [12.06, 13.69] | 0.452 [0.393, 0.509] | 1.212 [1.116, 1.316] | 0.193 [0.178, 0.211] |\n| EDM tuned (35 NFE) | 0.0709 [0.0676, 0.0740] | 0.693 [0.687, 0.699] | 10.76 [9.90, 11.57] | 0.571 [0.509, 0.631] | 1.192 [1.138, 1.254] | 0.190 [0.175, 0.208] |\n| EDM tuned (17 NFE) | 0.0707 [0.0674, 0.0738] | 0.680 [0.674, 0.686] | 10.51 [9.67, 11.34] | 0.584 [0.527, 0.642] | 1.340 [1.279, 1.411] | 0.193 [0.178, 0.210] |\n| CorrDiff | 0.0734 [0.0697, 0.0769] | 0.717 [0.710, 0.723] | 11.60 [10.71, 12.52] | 0.691 [0.659, 0.716] | 1.857 [1.717, 2.011] | 0.131 [0.117, 0.147] |\n| CorrDiff tuned | 0.0711 [0.0679, 0.0742] | 0.735 [0.729, 0.742] | 9.72 [8.81, 10.68] | 0.718 [0.681, 0.754] | 1.430 [1.355, 1.514] | 0.124 [0.114, 0.135] |\n| PNO | 0.0711 [0.0679, 0.0741] | 0.791 [0.783, 0.798] | 6.56 [6.16, 6.96] | 0.887 [0.877, 0.896] | 3.528 [3.316, 3.764] | 0.212 [0.203, 0.223] |\n\nCoverage is nominal at 0.90; a count ratio of 1 and a $W_1$ of 0 mean matched; FSS is 1 when perfect.\n\nOn the test conditions, the picture is mixed and we report it as such. At light rain (1 mm/day), the diffusion baselines are close to the calibrated floor. In the high-intensity bin, NCS has lower reliability error than all diffusion baselines at 10 and 50 mm/day (0.051 vs. 0.079-0.091; 0.006 vs. 0.010-0.012), while the tuned diffusion models are best at 20 mm/day (0.023-0.024 vs. 0.033). Brier scores at 20 mm/day are indistinguishable across all arms. NCS reproduces the intensity of the most extreme cells far better than diffusion ($W_1$ of the 99th percentile 6.4 vs. 9.7-12.9) and places heavy rain more accurately (FSS 0.87 vs. 0.45-0.72; PNO 0.89), with the best wet-pixel coverage (0.84 vs. 0.68-0.74). It produces too few rain objects (count ratio 0.80) where diffusion produces too many. The amplitude-conditional objective improves the pooled tail but leaves the conditional diagnostics largely unchanged. From 10 mm/day upward, reliability differences from default NCS are within the intervals, and Brier score, 99th-percentile $W_1$ and FSS are unchanged; coverage is slightly lower (0.832 vs. 0.841). L4 does produce fewer heavy-rain objects (count ratio 0.68 vs. 0.80) with a less realistic size distribution (log-area $W_1$ 0.332 vs. 0.253). L2 matches default NCS except at light rain in the low-intensity bin, where it reduces reliability error (0.081 vs. 0.117).\n\n`[REVISION]` We add these diagnostics with uncertainties to Appendix F and reference them from Sec. 5.4 and the limitations.\n\n> *Q5. Target-derived conditioning.*\n\nAgreed; see our answer to eL2g Q2 for the construction. The condition is the coarsened mean of the members being refined, so the experiment is conditional reconstruction given a consistent coarse field, more favourable than refining an independent coarse forecast, and robustness to coarse-model bias is untested on the main non-Gaussian application. We will restrict the precipitation claims to that scope, report the split-member control as a measure of the endogeneity, and state the limitation in Sec. 4 and the limitations section. We regard an independently conditioned precipitation benchmark as the right next step and do not claim it here."+ },+ "createdAt": "2026-11-12T08:25:04.165Z",+ "modifiedAt": "2026-11-12T08:25:04.165Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=EAbnv7ZIed",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/gb0kaytkyi.json added
+++ b/reviews/openreview/ap806khcn2/notes/gb0kaytkyi.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "GB0kaYTKYi",+ "replyTo": "hg2tZqYNm3",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Follow-up on our response",+ "comment": "Dear Reviewer eL2g,\n\nThank you for your positive and constructive review. In our response (Parts 1 and 2 above) we added the CRPS comparison for the amplitude-conditional objectives, stated when we recommend them, described how the GARD-LENS coarse condition is constructed, and added a condition–member mismatch sweep on Navier–Stokes.\n\nAs the discussion period ends on 18 November, we would be grateful to know whether this answers your questions and whether it has strengthened your view of the paper. We are happy to clarify anything further."+ },+ "createdAt": "2026-11-17T09:45:33.143Z",+ "modifiedAt": "2026-11-17T09:45:33.143Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=GB0kaYTKYi",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/gtlvwhukvg.json added
+++ b/reviews/openreview/ap806khcn2/notes/gtlvwhukvg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "gTLvWHUkvg",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Area Chair,\n\nWe thank you and the reviewers for a constructive discussion. In our view, the paper's central claims hold and are now better supported than in the submitted version. In particular, we show where our work extends the literature and what advantage our approach provides over classical and diffusion baselines ([theoretical advantages](https://openreview.net/forum?id=aP806kHcn2¬eId=Zla60i4eM9), [comparison to baselines](https://openreview.net/forum?id=aP806kHcn2¬eId=237UGfWbNL)).\n\n**Reviewer yLXT** listed requests that \"could materially change my assessment\". We provided every requested result ([1](https://openreview.net/forum?id=aP806kHcn2¬eId=TjNSksV97d), [2](https://openreview.net/forum?id=aP806kHcn2¬eId=KMrJWeHmew), [3](https://openreview.net/forum?id=aP806kHcn2¬eId=EAbnv7ZIed)). Together, these results support the paper's claims and strengthen the case for the method. On conditioning, the reviewer wrote that \"clarifying the limitations imposed by target-derived conditioning would be sufficient\". We did exactly this: the construction is now stated explicitly, and the precipitation claims are restricted to conditional reconstruction ([construction](https://openreview.net/forum?id=aP806kHcn2¬eId=EAbnv7ZIed), [scope of claims](https://openreview.net/forum?id=aP806kHcn2¬eId=3Q5l5g5NTw)). We therefore believe all of yLXT's requests have been addressed.\n\n**Reviewer HC6i** raises no substantive soundness concerns. We answered the original question and all seven listed weaknesses. On 16 November, we also answered the three follow-up questions on the [theoretical advantages of the construction](https://openreview.net/forum?id=aP806kHcn2¬eId=237UGfWbNL), the evaluation set ([1](https://openreview.net/forum?id=aP806kHcn2¬eId=chMniUxjHU), [2](https://openreview.net/forum?id=aP806kHcn2¬eId=qHJBtsJtjX)), and the [supply–reach classification](https://openreview.net/forum?id=aP806kHcn2¬eId=Km5kxGwCGx).\n\n**Reviewer eL2g** recommends weak acceptance and likewise raises no substantive soundness concerns. We answered both questions with new results ([Q1](https://openreview.net/forum?id=aP806kHcn2¬eId=p54Ru90yY8), [Q2](https://openreview.net/forum?id=aP806kHcn2¬eId=3Q5l5g5NTw)).\n\nNo reviewer challenged the contributed theory or identified an error in the method. The discussion has left the paper's foundations intact and its evidence considerably stronger.\n\nSincerely,\nThe Authors"+ },+ "createdAt": "2026-11-19T11:57:55.332Z",+ "modifiedAt": "2026-11-19T11:57:55.332Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=gTLvWHUkvg",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/gysgyrbm29.json added
+++ b/reviews/openreview/ap806khcn2/notes/gysgyrbm29.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "gYSGyrbM29",+ "replyTo": "Zla60i4eM9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer HC6i",+ "content": {+ "comment": "I noticed that some GARD-LENS results in the rebuttal differ from those in the original manuscript. In Table 1, the NCS energy score and CRPS are 473.7 and 1.588, while the rebuttal reports 460.7 and 1.571. The corresponding PNO values also differ (476.2 vs. 462.4 for energy score, and 1.612 vs. 1.592 for CRPS). In addition, the initial lag-2 kurtosis ratio is 0.174 ± 0.030 in Table 15, but 0.21 in the rebuttal. Could the authors clarify whether these differences reflect updated experiments or changes in the evaluation setup?"+ },+ "createdAt": "2026-11-14T18:11:37.201Z",+ "modifiedAt": "2026-11-14T18:11:37.201Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=gYSGyrbM29",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/hg2tzqynm3.json added
+++ b/reviews/openreview/ap806khcn2/notes/hg2tzqynm3.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "hg2tZqYNm3",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer eL2g",+ "content": {+ "paper_summary": "This paper proposes Neural Conditional Simulation (NCS), a framework for refining coarse PDE solutions into high-resolution stochastic fields. It combines classical Gaussian conditional simulation with a learned nonlinear innovation to capture structures that Gaussian assumptions cannot represent. The method uses a coarse-to-fine cascade with one network evaluation per level. Experiments on stochastic Allen–Cahn, Navier-Stokes, and GARD-LENS precipitation demonstrate competitive accuracy, uncertainty calibration, and spectral properties compared with diffusion models, at substantially lower inference cost.",+ "presentation": 3,+ "informativeness": 2,+ "soundness": 3,+ "critical_strengths": "Building on classical kriging and Gaussian conditional simulation is a well-motivated approach. Rather than learning the entire conditional distribution from scratch, the method learns the correction to an existing statistical model. The Gaussian simulator provides a meaningful baseline, making it possible to assess what the neural network actually contributes. I find this particularly interesting.\nThe evaluation covers several stochastic systems and compares against classical methods, neural operators, and diffusion models. The authors examine CRPS, energy score, ensemble spread, spectral properties, and extreme statistics. The results are encouraging, particularly the ability to obtain competitive probabilistic performance with substantially fewer network evaluations. The controlled experiments investigating where the Gaussian assumptions fail also strengthen the contribution.",+ "critical_weaknesses": "Although NCS achieves good overall calibration, the standard energy-score model substantially underestimates the heavy-tailed increment statistics on GARD-LENS, with a kurtosis ratio of 0.17. The authors address this using an amplitude-conditional objective, which is encouraging, but it shows that the standard formulation does not fully capture important extremes. Since these are particularly relevant for precipitation applications, this limitation deserves more emphasis. Can you please elaborate this? It would be nice addition to the paper. Maybe in the camera ready version add this.",+ "questions_for_authors": "1. The amplitude-conditional objective substantially improves the precipitation tails. Would you recommend this as the default NCS formulation for strongly non-Gaussian fields? How does its CRPS compare with the original NCS model?\n\n2. Could you clarify how the common coarse conditioning is constructed from the GARD-LENS ensemble members? How sensitive might the approach be to biases in independently generated coarse-resolution inputs?",+ "flag_for_ethics_review": "No",+ "rating": 3,+ "confidence": 3+ },+ "createdAt": "2026-10-19T08:16:24.865Z",+ "modifiedAt": "2026-11-17T06:49:05.386Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=hg2tZqYNm3",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/km5kxgwcgx.json added
+++ b/reviews/openreview/ap806khcn2/notes/km5kxgwcgx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Km5kxGwCGx",+ "replyTo": "aQDhF7IE29",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Q3: How do the authors tell an objective limitation apart from limits of the model and its training?\n\nA negative source–transport sweep alone would not establish this, and our classification does not stop there. The sweep tells us where to look. The classification itself rests on two direct measurements, which we now state explicitly in the protocol. We call a deficit reach-limited only when both hold.\n\n1. The same model reaches the structure. With source, transport, architecture, identity initialization, pretraining protocol, training budget and batch matched, changing only the objective recovers substantially more of the missing statistic. On SHE–PAM, adding a flatness term at the smallest dose raises the increment kurtosis from 3.99 to 35.9 against a data value of 38.3 (Table 14); on GARD-LENS, K62 slope matching raises the lag-2 kurtosis ratio from 0.21 to 0.84. Capacity is therefore not what holds the statistic at its original value: parameters in the same model class produce the improved statistic, and the same optimizer and budget find them.\n\n2. The original objective shows no measurable preference between the two models. If the energy score clearly preferred the tail-correct model, failing to find it would be an optimization failure. It does not:\n\n- Navier–Stokes, batch-matched (yLXT Q2): ES 312.9 [311.6, 314.2] for the energy-score control and 312.8 [311.5, 314.1] with the threshold-weighted term, while $q_{99}$ moves from 2.02 to 3.04 (data 2.90), with non-overlapping intervals.\n- GARD-LENS (128 conditions): ES 460.71 with the energy score alone, 460.71 with amplitude-stratified ES (L2) and 460.78 with K62 slope matching (L4), at σ/s 0.98 in all three cases, while the lag-2 kurtosis ratio differs (values in our response to yLXT, Q1).\n\n\nIn each case the tail changes strongly while the energy score changes by less than its own uncertainty. At the resolution of a finite-sample score, the objective therefore gives the optimizer little signal toward the tail. This is what we mean by reach-limited. It agrees with limit (ii) in Sec. 4: strict propriety guarantees a preference for the true law in population and says nothing about a finite-sample score's sensitivity to tails."+ },+ "createdAt": "2026-11-16T13:20:58.486Z",+ "modifiedAt": "2026-11-16T13:20:58.486Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=Km5kxGwCGx",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/kmrjwehmew.json added
+++ b/reviews/openreview/ap806khcn2/notes/kmrjwehmew.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "KMrJWeHmew",+ "replyTo": "M1LKWDMUp4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 4/5",+ "comment": "> *Q4. Conditional exceedance / coverage for the amplitude-conditional model.*\n\nWe agree that pooled kurtosis does not establish reliable conditional extremes, and that spatial organization is a separate question. All predictions are stored, so we rescored the default model, the amplitude-conditional models (L2, L4) and the baselines on all 128 test conditions without retraining: the E3 predictions of Q3, with the diffusion baselines at their default samplers, plus the standardized-target, validation-tuned EDM and CorrDiff of Q1:\n\n- exceedance reliability error at 1, 10, 20 and 50 mm/day, stratified by coarse-condition intensity (terciles fit on training conditions), against the exceedance frequency over the eight data members, and the Brier score;\n- central 90% interval coverage on wet pixels;\n- Wasserstein distance between ensemble and data 99th spatial percentiles;\n- fractions skill score (FSS) at 20 mm/day, $9 \\times 9$ neighbourhood;\n- connected-object count ratio (model / data) and the Wasserstein distance of $\\log_{10}$ object area at 20 mm/day.\n\nReliability error is the frequency-weighted gap between forecast exceedance probability (fraction of 32 members) and observed frequency (fraction of 8 data members) over ten bins. Because $K = 8$ quantizes the observed frequency, even a perfect forecast reads above zero; we report the expected floor simulated from the data's own frequencies. It is an expectation, not a bound, so individual cells can fall below it by chance. Ocean pixels are excluded, and cells with fewer than 200 data exceedances are omitted. Seed means over 3 seeds; 95% condition-bootstrap intervals in brackets.\n\nReliability error by threshold (mm/day) and intensity bin (lower is better).\n\n| Model | $>1$, low | $>1$, mid | $>1$, high | $>10$, mid | $>10$, high | $>20$, mid | $>20$, high | $>50$, high |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|\n| NCS | 0.1174 [0.1104, 0.1241] | 0.1592 [0.1537, 0.1643] | 0.1307 [0.1195, 0.1423] | 0.0190 [0.0178, 0.0201] | 0.0506 [0.0472, 0.0545] | 0.0017 [0.0016, 0.0019] | 0.0333 [0.0313, 0.0353] | 0.0059 [0.0048, 0.0070] |\n| NCS+L2 | 0.0813 [0.0757, 0.0868] | 0.1537 [0.1484, 0.1589] | 0.1193 [0.1086, 0.1309] | 0.0195 [0.0183, 0.0206] | 0.0496 [0.0463, 0.0534] | 0.0017 [0.0016, 0.0019] | 0.0323 [0.0304, 0.0343] | 0.0057 [0.0046, 0.0068] |\n| NCS+L4 | 0.1073 [0.0997, 0.1147] | 0.1713 [0.1657, 0.1768] | 0.1495 [0.1382, 0.1612] | 0.0206 [0.0194, 0.0217] | 0.0485 [0.0454, 0.0521] | 0.0019 [0.0017, 0.0021] | 0.0334 [0.0314, 0.0354] | 0.0063 [0.0052, 0.0074] |\n| EDM | 0.0209 [0.0199, 0.0219] | 0.0571 [0.0546, 0.0596] | 0.1265 [0.1160, 0.1374] | 0.0220 [0.0208, 0.0232] | 0.0907 [0.0890, 0.0923] | 0.0016 [0.0014, 0.0018] | 0.0281 [0.0262, 0.0301] | 0.0116 [0.0099, 0.0134] |\n| EDM tuned (35 NFE) | 0.0206 [0.0197, 0.0215] | 0.0583 [0.0561, 0.0606] | 0.1161 [0.1058, 0.1263] | 0.0207 [0.0195, 0.0216] | 0.0893 [0.0876, 0.0910] | 0.0015 [0.0012, 0.0018] | 0.0244 [0.0225, 0.0262] | 0.0108 [0.0093, 0.0129] |\n| EDM tuned (17 NFE) | 0.0208 [0.0199, 0.0217] | 0.0582 [0.0561, 0.0607] | 0.1159 [0.1052, 0.1264] | 0.0196 [0.0187, 0.0210] | 0.0897 [0.0878, 0.0914] | 0.0015 [0.0011, 0.0017] | 0.0243 [0.0225, 0.0260] | 0.0096 [0.0084, 0.0111] |\n| CorrDiff | 0.0233 [0.0222, 0.0247] | 0.0636 [0.0608, 0.0665] | 0.1578 [0.1482, 0.1681] | 0.0195 [0.0184, 0.0207] | 0.0811 [0.0775, 0.0847] | 0.0013 [0.0011, 0.0015] | 0.0254 [0.0233, 0.0274] | 0.0111 [0.0095, 0.0128] |\n| CorrDiff tuned | 0.0222 [0.0214, 0.0230] | 0.0630 [0.0607, 0.0651] | 0.1458 [0.1327, 0.1608] | 0.0193 [0.0182, 0.0205] | 0.0788 [0.0750, 0.0824] | 0.0013 [0.0010, 0.0015] | 0.0231 [0.0214, 0.0248] | 0.0105 [0.0090, 0.0119] |\n| PNO | 0.0309 [0.0293, 0.0325] | 0.2080 [0.2006, 0.2151] | 0.2252 [0.2141, 0.2367] | 0.0189 [0.0177, 0.0201] | 0.0498 [0.0475, 0.0524] | 0.0051 [0.0047, 0.0055] | 0.0255 [0.0235, 0.0275] | 0.0118 [0.0093, 0.0144] |\n| *floor (expected, calibrated)* | 0.0190 | 0.0304 | 0.0301 | 0.0120 | 0.0287 | 0.0008 | 0.0214 | 0.0041 |"+ },+ "createdAt": "2026-11-12T08:24:15.617Z",+ "modifiedAt": "2026-11-12T08:24:15.617Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=KMrJWeHmew",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/m1lkwdmup4.json added
+++ b/reviews/openreview/ap806khcn2/notes/m1lkwdmup4.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "M1LKWDMUp4",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer yLXT",+ "content": {+ "paper_summary": "This paper proposes Neural Conditional Simulation (NCS) for generating fine-resolution PDE fields conditioned on a coarse solution. Its motivation is that squared-error refinement estimates a conditional mean and therefore misses unresolved variability. NCS combines a fixed kriging/Wiener predictor with a learned, condition-dependent transformation of a spectrally fitted innovation. An identity initialization embeds classical Gaussian conditional simulation, which is exact under joint Gaussianity with exact covariance information. Sampling proceeds through a coarse-to-fine cascade with one network evaluation per level, using drifting pretraining followed by end-to-end energy-score optimization.\n\nThe main contribution is a framework that makes gains beyond Gaussian conditioning measurable. A second contribution is a diagnostic distinction between “supply-limited” errors requiring changes to the source or transport and “reach-limited” errors requiring a different training objective. The theoretical analysis establishes Gaussian exactness under ideal conditions and population identification through proper scoring, without guaranteeing finite-sample convergence or exactness of the full cascade.\n\nValidation combines stochastic Allen–Cahn and Navier–Stokes benchmarks, GARD-LENS precipitation ensembles, and controlled Gaussian and non-Gaussian experiments. Comparisons cover deterministic refiners, classical simulators, probabilistic neural operators, consistency models, and diffusion methods. Evaluation includes proper scores, ensemble calibration, spectral errors, tail statistics, cross-scale consistency, and runtime, supported by component and objective ablations.\n\nReported gains over classical methods are modest on near-Gaussian benchmarks but larger for precipitation, where NCS achieves a spread–skill ratio of 0.96 at competitive CRPS and spectral error. Sampling is reported to be 17–36 times faster than 35-evaluation diffusion baselines. Energy-score training alone substantially underestimates heavy tails; an amplitude-conditioned objective recovers approximately 78% of the precipitation increment-kurtosis deficit without degrading global calibration.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 2,+ "critical_strengths": "A useful connection between classical conditional simulation and learned refinement.\nNCS retains an explicit kriging predictor and learns a conditional transformation of the innovation, with Gaussian conditional simulation available as an identity-map baseline. This gives the neural component a meaningful statistical reference against which its contribution can be measured. The theoretical discussion also distinguishes population guarantees from the approximations introduced by estimated covariances and finite neural networks. Although the individual ingredients are established, their combination provides an interpretable approach to stochastic refinement. This supports acceptance because the formulation helps identify when learning adds value and when a simpler classical simulator already performs adequately.",+ "critical_weaknesses": "1. **The comparisons do not fully establish the practical quality–cost advantage.** The paper includes useful baseline and sampling-budget studies, but several comparisons remain difficult to interpret. The GARD-LENS diffusion sweep changes the inference-time noise ceiling and step count while keeping the training noise distribution unchanged (Appendix F.6). It therefore does not establish whether the reported underdispersion persists after tuning the training setup for this heavy-tailed dataset. Similarly, the headline 17–36× speedup is measured against 35-evaluation diffusion, although the sampling-budget study reports that the iterative methods approach their best scores at roughly 8–11 evaluations. The timing study also uses the smaller Navier–Stokes problem, whereas the main accuracy table uses the larger one. These choices do not invalidate the reported measurements, but leave the advantage at comparable quality and resolution less certain. Section 5.4 also acknowledges a batch-size difference in the threshold-weighted ablation despite Table 13 describing objective-only changes. Since efficiency and diagnostic attribution are central contributions, latency measurements at the best validated sampling budgets and a matched-batch objective ablation are important to my assessment.\n\n2. **Validation of reliable conditional tail simulation remains incomplete.** The precipitation experiments demonstrate that global variance calibration can coexist with substantial tail errors. The main energy-score model reaches an increment-kurtosis ratio of only 0.17, and the amplitude-conditioned extension improves this to approximately 0.81–0.83 (Tables 1 and 15). This correction is encouraging, and the authors acknowledge the remaining deficit. However, improved pooled kurtosis at two lags does not establish accurate conditional exceedance probabilities or the spatial organization of extremes. More direct evaluation of these properties for the corrected model would be consequential given the paper’s motivation in uncertainty-sensitive scientific simulation. Furthermore, GARD-LENS conditions are constructed by coarsening the high-resolution fields, rather than using an independently generated coarse forecast (Appendix D.1). This is a valid conditional reconstruction task, but it leaves robustness to coarse-model bias untested on the main non-Gaussian application. Consequently, the evidence supports a promising refinement method under the evaluated conditions more strongly than broad practical reliability. Conditional extreme-event diagnostics and an independently conditioned precipitation benchmark would help determine whether the reported improvements extend to the setting motivating the application.",+ "questions_for_authors": "These clarification requests could materially change my assessment:\n\n1. **Baseline tuning and efficiency.** Table 19 varies sampling parameters while keeping the training noise distribution fixed. How was that distribution selected for GARD-LENS? Was training-time tuning investigated? What speedups remain at the best validated sampling budgets, using comparable quality targets and resolutions?\n\n2. **Objective attribution.** Section 5.4 mentions a smaller batch for the threshold-weighted objective, while Table 13 describes objective-only changes. Which settings differed? Is there an existing matched-batch comparison showing whether the reported tail and spectral gains persist?\n\n3. **Evaluation protocol.** Table 3 lists 128 GARD-LENS test conditions, whereas Table 19 refers to 64. Is this a fixed subset, how was it selected, and were NCS and all baselines evaluated on precisely the same conditions?\n\n4. **Conditional tail reliability.** For the amplitude-conditioned model in Table 15, are conditional exceedance probabilities or coverage results available beyond pooled increment kurtosis? Such diagnostics would help determine whether the correction improves extreme-event reliability across intensity levels.\n\nEvaluating independently generated coarse forecasts would be useful future work. For the current submission, clarifying the limitations imposed by target-derived conditioning would be sufficient to establish the intended scope of the precipitation results and their relevance to deployment.",+ "flag_for_ethics_review": "No",+ "rating": 2,+ "confidence": 2+ },+ "createdAt": "2026-11-01T18:52:48.136Z",+ "modifiedAt": "2026-11-06T12:39:33.308Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=M1LKWDMUp4",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/npmarewird.json added
+++ b/reviews/openreview/ap806khcn2/notes/npmarewird.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "NPmaRewird",+ "replyTo": "RHum2LjWuY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 2/3",+ "comment": "> *W5: Stationary spectral source and spatially varying patterns.*\n\nBoth the source and the kriging mean are stationary, so any nonstationarity must come from the learned part. In Appendix C.6 we test this on a Gaussian control which is built so that every stationary predictor must fail. In this experiment, the exact conditional mean mixes two disjoint frequency bands with a spatially varying weight. Because the control is Gaussian the best achievable result is known, and the stationary filter's gap is 78% of the local-variance error. Fraction of that ceiling recovered:\n\n| Arm | Recovered |\n|---|---|\n| Locally stationary filter | $0.54\\times$ |\n| Per-pixel rescaling | $0.51\\times$ |\n| Season-stratified filter | $-0.15\\times$ |\n| Learned correction (Appendix C.6) | **$1.00\\times$** |\n\nOn GARD-LENS, where no ceiling exists, the same correction improves on the global filter by 61-68%. In the default cascade the transport can vary in space through the coarse condition $c$; however, we haven't measured to which extent, and we add this to the limitations.\n\n`[REVISION]` Move this result into the discussion of the source, with the attribution above.\n\n> *W6: The supply/reach line is not fully clear.*\n\nWe agree the line needs a sharper definition, and we will add one. The two classes ask different questions about a deficit. *Supply-limited:* can the model produce the structure at all? *Reach-limited:* the model can produce it, but does the training objective ask for it? In practice, we use the following protocol to distinguish between the two:\n\n**Protocol.**\n\n1. **Diagnose.** Score the trained model against the GCS floor on spread, spectrum, the increment-kurtosis ratio and the amplitude-binned variance ratio $R\\_{var}$ (Appendix D.3). If all of them match the data, stop.\n2. **Test supply.** Keep the energy score and vary the source (Gaussian $\\rightarrow$ Nataf) and the transport (identity $\\rightarrow$ affine $\\rightarrow$ full), as in the factorial of Table 12.\n3. **Classify and fix.**\n - **3a. The deficit responds $\\rightarrow$ supply-limited.** The fix is the source or transport that moved it.\n *Examples from the paper:* on Allen-Cahn only the Nataf source reaches the tail ($\\kappa/\\kappa\\_{data}$ 1.1 vs 0.7-0.8); with a nonlinear conditional mean only the learned transport helps (CRPS 0.60 vs 1.13-1.16).\n - **3b. No source $\\times$ transport cell moves the deficit $\\rightarrow$ reach-limited.** The fix is an added objective term, and $R\\_{var}$ decides which one: a scale-free flatness term if $R\\_{var}$ is flat across amplitude (homogeneous deficit), or an amplitude-conditional term (e.g., amplitude-stratified ES or K62 slope matching) if $R\\_{var}$ crosses one. Each term is dosed at the smallest weight that moves the tail, keeping nRMSE, $\\sigma/s$ and logPSD inside fixed guards.\n *Examples from the paper:* on SHE-PAM the Gaussian source reaches $\\kappa = 3.99$ against 38.3 and the deficit is homogeneous, and a flatness term closes 93%. On GARD-LENS $R\\_{var}$ crosses one ($3.8\\times$ over-dispersed at low amplitude, $0.87\\times$ in the tail), so a flatness term cannot bend it; amplitude-conditional terms do: K62 slope matching (L4) closes 80% of the kurtosis deficit and amplitude-stratified ES (L2) 62%.\n\nStep (1) is the one that should not be skipped. On GARD-LENS, default NCS passes every aggregate check ($\\sigma/s$ 0.98, competitive CRPS and spectrum) while reproducing only 21% of the increment kurtosis.\n\n`[REVISION]` Add this protocol to Sec. 4.1 as the definition of the taxonomy."+ },+ "createdAt": "2026-11-12T08:09:33.150Z",+ "modifiedAt": "2026-11-12T08:09:33.150Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=NPmaRewird",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/p3nwxctuld.json added
+++ b/reviews/openreview/ap806khcn2/notes/p3nwxctuld.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "p3nWXctUlD",+ "replyTo": "RHum2LjWuY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Follow-up on our answers to your questions",+ "comment": "Dear Reviewer HC6i,\n\nThank you for your careful follow-up questions. They led us to state the theoretical advantages of NCS more precisely and to make the supply–reach protocol rest on a positive experimental test, which has clearly improved the paper.\n\nWe have answered all three questions above. As the discussion period ends on 18 November, we would be grateful to hear whether our answers address your concerns and have changed your assessment of the paper. We are happy to clarify anything that remains open."+ },+ "createdAt": "2026-11-17T09:46:42.605Z",+ "modifiedAt": "2026-11-17T09:46:42.605Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=p3nWXctUlD",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/p54ru90yy8.json added
+++ b/reviews/openreview/ap806khcn2/notes/p54ru90yy8.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "p54Ru90yY8",+ "replyTo": "hg2tZqYNm3",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 1/2",+ "comment": "> *Weakness and Q1: The 0.17 kurtosis ratio deserves more emphasis. Should the amplitude-conditional objective be the default for strongly non-Gaussian fields? How does its CRPS compare?*\n\nWe agree, and we answer both together because the second is the remedy for the first. Default NCS trained with the energy score is calibrated in spread ($\\sigma/s$ 0.98) and competitive on CRPS and spectrum, yet its lag-2 increment-kurtosis ratio is 0.21 on all 128 test conditions (0.17 on the 64 of Table 1), which means that NCS's predictions of small-scale fluctuations are far less heavy-tailed than the data's. The cause is the objective, not the sampler. The energy score is dominated by the bulk of the distribution, and rare intense cells contribute little to it. On GARD-LENS, the deficit is intensity-dependent. The ensemble is $3.8\\times$ over-dispersed at low rain rates and $0.87\\times$ under-dispersed in the tail, and an aggregate score cannot see that pattern.\n\nFollowing this diagnosis, we changed only the objective and kept the model fixed. Each row below adds one amplitude-conditional term to the default energy score: amplitude-stratified ES (L2) or K62 slope matching (L4):\n\n| Method | RMSE | ES | CRPS | Corrected $\\sigma/s$ | logPSD | $\\kappa/\\kappa_{\\mathrm{data}}$ |\n|---|:---:|:---:|:---:|:---:|:---:|:---:|\n| NCS-Drift+ES | $1.158 \\pm 0.019$ | $460.7 \\pm 0.3$ | $1.571 \\pm 0.010$ | $0.982 \\pm 0.014$ | $0.131 \\pm 0.014$ | $0.21 \\pm 0.04$ |\n| NCS-Drift+ES + L2 | $1.159 \\pm 0.018$ | $460.7 \\pm 0.3$ | $1.554 \\pm 0.005$ | $0.981 \\pm 0.014$ | $0.143 \\pm 0.013$ | $0.70 \\pm 0.04$ |\n| NCS-Drift+ES + L4 | $1.151 \\pm 0.021$ | $460.8 \\pm 0.3$ | $1.573 \\pm 0.009$ | $0.976 \\pm 0.014$ | $0.058 \\pm 0.002$ | $0.84 \\pm 0.03$ |\n\nL4 matches how fluctuation size grows with local intensity. It raises the kurtosis ratio from 0.21 to 0.84 and more than halves logPSD at unchanged ES, CRPS and spread. Among the original-recipe baselines, only multi-step consistency sampling reaches a comparable tail (up to 1.10), and only when strongly under-dispersed ($\\sigma/s \\leq 0.57$).\n\n**Should it be the default?** For fields whose tail arises from intensity-dependent variability, such as precipitation, yes: L4, or L2 if CRPS is the priority. We would not make it the default for all non-Gaussian fields, because it targets one mechanism. If the tail is intrinsic (e.g., Student-t innovations with amplitude-independent scale), $R\\_{var}$ is flat and L4 has nothing to match. In such a case a scale-free flatness term is the right choice (SHE-PAM, 93% closed). $R\\_{var}$, computed on the default model, distinguishes the two cases before the added term is chosen (step 3 of the protocol in our answer to HC6i W6).\n\nWhether the improved pooled tail translates into better conditional extremes is a separate question, which yLXT also raised. Please see the conditional exceedance, coverage, FSS and object diagnostics in our answer to yLXT Q4.\n\n`[REVISION]` We state the default model's tail deficit and its cause in the main results and limitations and add the L4 row with CRPS to the main text and present L4 as the recommended objective for precipitation-like fields."+ },+ "createdAt": "2026-11-12T08:13:43.171Z",+ "modifiedAt": "2026-11-12T08:13:43.171Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=p54Ru90yY8",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/qhjbtsjtjx.json added
+++ b/reviews/openreview/ap806khcn2/notes/qhjbtsjtjx.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "qHJBtsJtjX",+ "replyTo": "M1LKWDMUp4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 3/5",+ "comment": "> *Q3. 128 vs. 64 GARD-LENS test conditions.*\n\nThe 1024 GARD-LENS conditions are split at random (split seed 0) into 768 training, 128 validation and 128 test. Every GARD-LENS row in Table 1, the schedule sweep of Table 19 and the objective ladder of Table 15 was scored on the same 64 of the 128 test conditions: a random subset fixed by the split seed before any model was trained, identical for every arm and seed. Sampling settings in Table 19 were selected on validation conditions only. The cap was chosen to bound the sampling cost of the 35-step diffusion baselines at $M = 32$.\n\nTo remove any doubt about the subset, we re-sampled every principal GARD-LENS row of Table 1 on all 128 test conditions, with the unchanged checkpoints and their default samplers. The standardized-target diffusion retrain with validation-selected settings is reported separately in Q1, already on 128 conditions. The conditions and targets are byte-identical across all 24 runs, and the first 64 are exactly the Table 1 conditions. Recomputed on those 64, the stored predictions reproduce Table 1 (e.g. NCS ES 473.7, CRPS 1.588; EDM 513.0, 1.535). Re-sampling reproduces it within seed noise.\n\nSeed means; 95% condition-bootstrap intervals for the 128-condition values (2000 replicates, the same resample for every row, seeds not resampled):\n\n**Panel A: accuracy**\n\n| Arm | ES ($n=64$) | ES ($n=128$) | CRPS ($n=64$) | CRPS ($n=128$) |\n|---|---:|---:|---:|---:|\n| NCS | 474.4 [441.3, 507.7] | 460.7 [438.6, 483.3] | 1.590 [1.472, 1.708] | 1.571 [1.487, 1.655] |\n| NCS+L2 | 474.5 [441.4, 507.8] | 460.7 [438.6, 483.3] | 1.571 [1.454, 1.687] | 1.554 [1.471, 1.636] |\n| NCS+L4 | 474.5 [441.4, 507.8] | 460.8 [438.7, 483.4] | 1.592 [1.473, 1.710] | 1.573 [1.489, 1.657] |\n| GCS | 505.8 [471.6, 540.5] | 490.3 [468.3, 512.8] | 2.499 [2.368, 2.634] | 2.460 [2.374, 2.548] |\n| PNO | 476.2 [443.4, 508.9] | 462.4 [440.2, 485.8] | 1.610 [1.490, 1.727] | 1.592 [1.514, 1.681] |\n| EDM | 513.0 [475.2, 549.9] | 497.0 [472.2, 522.3] | 1.536 [1.408, 1.664] | 1.509 [1.427, 1.603] |\n| CorrDiff | 508.4 [469.3, 548.0] | 491.4 [466.2, 517.4] | 1.552 [1.422, 1.688] | 1.521 [1.432, 1.610] |\n| Consistency | 514.4 [475.3, 553.2] | 497.0 [471.9, 522.7] | 1.583 [1.447, 1.722] | 1.550 [1.460, 1.642] |\n\n**Panel B: calibration and spectrum**\n\n| Arm | $\\sigma/s$ ($n=64$) | $\\sigma/s$ ($n=128$) | logPSD ($n=64$) | logPSD ($n=128$) |\n|---|---:|---:|---:|---:|\n| NCS | 0.964 [0.939, 0.993] | 0.982 [0.960, 1.006] | 0.147 [0.115, 0.180] | 0.131 [0.111, 0.154] |\n| NCS+L2 | 0.963 [0.937, 0.992] | 0.981 [0.959, 1.005] | 0.160 [0.127, 0.193] | 0.143 [0.121, 0.166] |\n| NCS+L4 | 0.959 [0.933, 0.987] | 0.976 [0.954, 1.000] | 0.071 [0.048, 0.101] | 0.058 [0.045, 0.078] |\n| GCS | 0.923 [0.859, 0.998] | 0.959 [0.912, 1.010] | 0.018 [0.015, 0.071] | 0.023 [0.013, 0.061] |\n| PNO | 1.000 [0.964, 1.035] | 1.036 [1.004, 1.066] | 0.536 [0.498, 0.577] | 0.551 [0.525, 0.575] |\n| EDM | 0.428 [0.414, 0.445] | 0.442 [0.430, 0.455] | 0.325 [0.286, 0.362] | 0.312 [0.288, 0.336] |\n| CorrDiff | 0.514 [0.496, 0.535] | 0.530 [0.515, 0.546] | 0.120 [0.095, 0.154] | 0.113 [0.098, 0.134] |\n| Consistency | 0.418 [0.400, 0.438] | 0.433 [0.419, 0.448] | 0.456 [0.416, 0.497] | 0.448 [0.422, 0.474] |"+ },+ "createdAt": "2026-11-12T08:23:35.344Z",+ "modifiedAt": "2026-11-12T08:23:35.344Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=qHJBtsJtjX",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/rhum2ljwuy.json added
+++ b/reviews/openreview/ap806khcn2/notes/rhum2ljwuy.json@@ -0,0 +1,24 @@+{+ "schema": "review/1",+ "id": "RHum2LjWuY",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer HC6i",+ "content": {+ "paper_summary": "The paper combines classical conditional simulation with a neural network. The network learns to correct the random part of the output. The goal is to generate conditional samples with fewer network passes than multi-step generators. This aims to keep useful detail while reducing sampling time.",+ "presentation": 2,+ "informativeness": 2,+ "soundness": 3,+ "critical_strengths": "1. The classical part is clear and easy to inspect. The reader can see what the neural part adds. This makes the starting point easy to understand. It also separates the learned part from the fixed part.\n2. The method has a clear structure. Each part has its own role. The steps are easy to identify. This makes the overall design easier to follow.\n3. The paper clearly states the limits of its theory. This helps readers understand what the method can and cannot guarantee.",+ "critical_weaknesses": "1. Most components already exist in earlier work. The main new part seems to be how they are combined. The paper could better show why this combination is useful.\n2. The paper explains many design choices in detail. This sometimes makes the main contribution harder to follow. A shorter explanation could make the key idea clearer.\n3. Much of the theory builds on known results. The paper offers few new theoretical results. It would help to state the theoretical contribution more clearly.\n4. The theory shows that a suitable transport exists. It does not guarantee that the chosen network can learn it. This gap could be explained more clearly.\n5. The source relies on a stationary spectral model. This may limit how it handles spatially changing patterns. The paper could explain how learning handles this limit.\n6. The paper separates two types of limits. But the line between them is not fully clear. A clearer rule would make the framework easier to use.\n7. The cascade uses independent noise at each level. It is not clear when this is enough to capture the full distribution across scales.",+ "questions_for_authors": "Could the authors explain what NCS adds beyond earlier methods? Which part of the design matters most? How does it differ from related approaches? A brief comparison would clarify its contribution and intended use.",+ "flag_for_ethics_review": "No",+ "rating": 1,+ "confidence": 2+ },+ "createdAt": "2026-10-19T17:00:29.153Z",+ "modifiedAt": "2026-11-14T17:05:16.990Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=RHum2LjWuY",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/tjnsksv97d.json added
+++ b/reviews/openreview/ap806khcn2/notes/tjnsksv97d.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "TjNSksV97d",+ "replyTo": "M1LKWDMUp4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 1/5",+ "comment": "> *Q1. How was the diffusion training noise distribution chosen for GARD-LENS? Was training-time tuning investigated?*\n\nEDM and CorrDiff were trained with the published EDM recipe: $\\sigma_{\\mathrm{data}}$ from the training residuals, training noise $\\ln \\sigma \\sim \\mathcal{N}(-1.2, 1.2^2)$. We did not tune the training-time distribution for GARD-LENS, and Table 19 varies sampling-time settings only, which could be swept from existing checkpoints (132 settings). The reviewer is right that this left open whether the under-dispersion persists after training-time tuning; it partially does.\n\nWe retrained EDM, CorrDiff and Consistency on GARD-LENS with the residual target standardized by training-split statistics (exact inverse at evaluation), three seeds, everything else unchanged. Sampling settings ($\\sigma_{\\max}$, $\\sigma_{\\min}$, steps: 180 settings for EDM and CorrDiff, 70 for Consistency) were selected on the validation conditions by a rule fixed in advance: $\\sigma/s \\in [0.85, 1.15]$, logPSD at most twice the best passing value, then lowest CRPS. The selected settings were then sampled once on all 128 test conditions. Seed means and 95% condition-bootstrap intervals:\n\n| Arm | Setting | ES | CRPS | $\\sigma/s$ | logPSD | $\\kappa/\\kappa_{\\mathrm{data}}$ | NFE |\n|---|---|---|---|---|---|---|---:|\n| EDM | old: paper checkpoint, default sampler | 497.00 [472.21, 522.28] | 1.509 [1.427, 1.603] | 0.442 [0.430, 0.455] | 0.312 [0.288, 0.336] | 0.19 [0.14, 0.25] | 35 |\n| EDM | tuned, default sampler | 469.15 [445.55, 492.48] | 1.486 [1.406, 1.565] | 0.859 [0.856, 0.905] | 0.102 [0.086, 0.127] | 0.61 [0.45, 0.83] | 35 |\n| EDM | tuned, val-selected (35 NFE) | 468.84 [444.36, 492.99] | 1.487 [1.407, 1.566] | 0.901 [0.879, 0.927] | 0.094 [0.081, 0.121] | 0.63 [0.47, 0.85] | 35 |\n| EDM | tuned, val-selected (17 NFE) | 468.97 [444.43, 492.24] | 1.487 [1.407, 1.566] | 0.897 [0.873, 0.924] | 0.095 [0.082, 0.120] | 0.57 [0.42, 0.77] | 17 |\n| CorrDiff | old: paper checkpoint, default sampler | 491.44 [466.15, 517.36] | 1.521 [1.432, 1.610] | 0.530 [0.515, 0.546] | 0.113 [0.098, 0.134] | 0.14 [0.11, 0.19] | 35+1 |\n| CorrDiff | tuned, default sampler | 475.93 [453.10, 499.10] | 1.493 [1.413, 1.573] | 0.796 [0.770, 0.826] | 0.092 [0.074, 0.115] | 0.51 [0.37, 0.69] | 35+1 |\n| CorrDiff | tuned, val-selected (grid edge) | 475.19 [452.73, 498.14] | 1.496 [1.416, 1.576] | 0.881 [0.851, 0.912] | 0.093 [0.074, 0.114] | 0.49 [0.35, 0.66] | 17+1 |\n| Consistency | old: paper checkpoint, default sampler | 497.01 [471.85, 522.74] | 1.550 [1.460, 1.642] | 0.433 [0.419, 0.448] | 0.448 [0.422, 0.474] | 0.26 [0.19, 0.35] | 2 |\n| Consistency | tuned, default sampler | 471.82 [449.22, 494.74] | 1.508 [1.427, 1.588] | 0.744 [0.723, 0.765] | 0.213 [0.188, 0.239] | 0.54 [0.34, 0.84] | 2 |\n| NCS | - | 460.71 [438.61, 483.31] | 1.571 [1.487, 1.655] | 0.982 [0.960, 1.006] | 0.131 [0.111, 0.154] | 0.21 [0.15, 0.29] | 1 |\n| NCS+L2 | - | 460.71 [438.59, 483.32] | 1.554 [1.471, 1.636] | 0.981 [0.959, 1.005] | 0.143 [0.121, 0.166] | 0.70 [0.64, 0.75] | 1 |\n| NCS+L4 | - | 460.78 [438.67, 483.36] | 1.573 [1.489, 1.657] | 0.976 [0.954, 1.000] | 0.058 [0.045, 0.078] | 0.84 [0.80, 0.89] | 1 |\n| GCS | - | 490.28 [468.32, 512.80] | 2.460 [2.374, 2.548] | 0.959 [0.912, 1.010] | 0.023 [0.013, 0.061] | 0.01 [0.01, 0.01] | 0 |\n\nTuning removes most of the diffusion baselines' under-dispersion. EDM's spread rises from $\\sigma/s$ 0.44 to 0.90, and with it CRPS ($1.509 \\rightarrow 1.487$), spectrum (logPSD $0.31 \\rightarrow 0.09$) and tail ($\\kappa/\\kappa_{\\mathrm{data}}$ $0.19 \\rightarrow 0.57$). CorrDiff improves similarly ($\\sigma/s$ $0.53 \\rightarrow 0.88$) and Consistency improves ($0.43 \\rightarrow 0.74$) but stays outside the window. The comparison with NCS is therefore a tradeoff rather than a ranking:\n\n1. Tuned EDM is better on CRPS (1.487 vs. 1.571) and spatial structure (logPSD 0.095 vs. 0.131).\n2. NCS is better on the multivariate score and spread: ES 460.7 vs. 469.0, $\\sigma/s$ 0.98 vs. 0.90.\n3. With the amplitude-conditional objective (L4), NCS reproduces the tail best ($\\kappa/\\kappa_{\\mathrm{data}}$ 0.84 vs. 0.57) and has the best spectrum (logPSD 0.058 vs. 0.095), at unchanged ES and spread. Its CRPS (1.573) remains behind tuned EDM.\n\nNCS does this with one network pass per member against 17 for the selected EDM setting, and without a noise schedule to set. We withdraw the statement that NCS is the only calibrated method on GARD-LENS, and revise the abstract and Sec. 5.2 to describe this tradeoff.\n\n`[REVISION]` We replace the GARD-LENS diffusion comparison in the abstract, introduction and Sec. 5.2 with this tradeoff. We add the E1 table and the validation-selection table to the appendix. We keep Table 19 but relabel it as the original-recipe sweep."+ },+ "createdAt": "2026-11-12T08:20:28.554Z",+ "modifiedAt": "2026-11-12T08:20:28.554Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=TjNSksV97d",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/vedaybyqva.json added
+++ b/reviews/openreview/ap806khcn2/notes/vedaybyqva.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vedAYByQVa",+ "replyTo": "RHum2LjWuY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 3/3",+ "comment": "> *W7: Independent noise per cascade level.*\n\nIndependent noise does not make the levels independent. Each level $l+1$ is conditioned on the full sample produced at level $l$, so whatever the coarser levels generated is passed on through that conditioning field. Independent per-level noise is therefore exact when the finer level depends on the coarser history only through the current level's sample (Eq. 29). It can fail when innovations at two levels are correlated in a way the intermediate sample does not carry, for example cross-scale coupling that bypasses the resolved field. On our benchmarks we find no sign of this and the dependent-noise alternatives below do not improve finest-level quality. In addition, the cascade is trained end to end, so each level's network can compensate for dependence the noise does not carry.\n\nWe tested this directly in the Appendix. We replaced the independent noise with three dependent alternatives: (i) a shared latent projected across levels, (ii) latents with the empirically fitted cross-level covariance, and (iii) an autoregressive latent in which each level's noise is conditioned on the previous level's innovation. On Allen-Cahn and Navier-Stokes with three seeds, none of them improves finest-level quality (energy score, nRMSE, $\\sigma/s$ and logPSD are unchanged within seed variance). The shared and fitted-covariance latents do slightly tighten consistency between levels (restriction error $0.096 \\rightarrow 0.074$ on Navier-Stokes). But independent noise already exceeds the data's cross-level coherence (0.944 vs 0.905), and dependent noise raises it further (0.966). So dependent noise brings no gain where it matters, and independent noise remains our default.\n\n`[REVISION]` State the sufficiency condition and the untested case in Sec. 3 and the limitations."+ },+ "createdAt": "2026-11-12T08:10:12.007Z",+ "modifiedAt": "2026-11-12T08:10:12.007Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=vedAYByQVa",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/vtkpx8islz.json added
+++ b/reviews/openreview/ap806khcn2/notes/vtkpx8islz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vtKpx8isLZ",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of the discussion and new evidence",+ "comment": "Dear Area Chair,\n\nThank you for handling our submission. We would like to briefly summarize the discussion. No reviewer identified an error in the theory or in the method: all theoretical results and the NCS algorithm stand as submitted, and two of the three reviews report no substantive soundness concerns. The reviewers' feedback has been very constructive, and it has strengthened the paper in the following ways.\n\nPrompted by the reviews, we added the following new evidence:\n- retrained diffusion baselines (EDM, CorrDiff, Consistency) with standardized targets and validation-selected sampling,\n- latency at the baselines' validated sampling budgets, including the resolution of the main table,\n- a matched-batch control for the objective ablation,\n- all GARD-LENS results evaluated on the full 128-condition test set,\n- conditional exceedance, coverage, fractions-skill and object diagnostics for precipitation extremes.\n\nWe believe these additions have made the value of NCS considerably clearer. Against properly tuned diffusion baselines, NCS remains well calibrated with a single network pass, at 17 times lower per-member latency than the best validated diffusion setting on GARD-LENS. It places heavy rain more accurately and covers wet pixels better than every diffusion baseline. The matched control confirms that the tail improvement comes from the objective, and every table reports exactly what learning adds over the exact Gaussian simulator. This is the central idea of the paper, and the discussion has made it easier to see.\n\nWe also sharpened the presentation. The GARD-LENS comparison is now framed as a quality–latency tradeoff, the precipitation results are clearly scoped to conditional reconstruction, the theoretical section states precisely what NCS guarantees, and the supply–reach taxonomy now rests on a positive experimental test with an explicit \"unresolved\" outcome.\n\nFor a quick overview of the method, we provide an anonymized 8-minute video summary: \nhttps://osf.io/9wqxy/overview?view_only=d6aa818868cc4c23bd330384f0b39423\n\nWe have invited all reviewers to share their view of these additions, and we would warmly welcome any further feedback from Reviewers yLXT and eL2g before the discussion closes.\n\nThank you for your time and support."+ },+ "createdAt": "2026-11-17T09:50:54.919Z",+ "modifiedAt": "2026-11-17T09:50:54.919Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=vtKpx8isLZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/notes/zla60i4em9.json added
+++ b/reviews/openreview/ap806khcn2/notes/zla60i4em9.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Zla60i4eM9",+ "replyTo": "RHum2LjWuY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Part 1/3",+ "comment": "> *W1, W3, Q: What does NCS add beyond earlier methods? Which part matters most?*\n\nThe guiding principle of NCS is to learn only what classical theory cannot already provide. Stochastic systems range from near-Gaussian to strongly non-Gaussian, and the current default is to learn the whole conditional law with a diffusion model. That spends network capacity and compute on structure that Gaussian conditional simulation gives in closed form, and it gives no anchor in the regime where the correct answer is known. NCS takes the opposite route. It is built on top of existing literature like kriging or Matheron's construction and we will highlight this in Section 3 more. NCS's motivation is rooted in the fact that classical conditional simulation is exact but cannot learn while neural generators can learn but start from nothing. NCS joins the two: it samples $\\hat{\\delta} = \\mathcal{K}c + g_\\theta(\\varepsilon, c)$, where the kriging mean $\\mathcal{K}c$ and the spectrally fitted innovation $\\varepsilon$ carry everything Gaussian theory provides, and the transport $g_\\theta$, initialized at the identity, learns only what that theory misses. Training therefore starts from a correct answer rather than from noise. At initialization NCS is Gaussian conditional simulation, exact for Gaussian fields with known covariance (Prop. 2), and already optimal for the training score in population (Cor. 3). As a consequence, NCS has three unique properties:\n\n1. The value of learning is measurable. Because the untrained model is a meaningful baseline rather than noise, we report in every table exactly what learning added. The gain is small where the field is near-Gaussian and large where it is not (CRPS, GCS $\\rightarrow$ NCS: Allen-Cahn $0.425 \\rightarrow 0.409$, Navier-Stokes $0.976 \\rightarrow 0.969$, GARD-LENS $2.460 \\rightarrow 1.571$). We are not aware of a learned refiner that reports this paired difference.\n2. Calibration comes from the anchor and not from a noise schedule. On GARD-LENS, NCS is calibrated at its standard recipe ($\\sigma/s$ 0.98) at one network pass. NCS leads against its closest one-pass relative PNO on ES (460.7 vs. 462.4), CRPS (1.571 vs. 1.592) and spectrum (logPSD 0.13 vs. 0.55). Diffusion baselines reach comparable spread only after target standardization and validation-tuned sampling (EDM $\\sigma/s$ $0.44 \\rightarrow 0.90$).\n3. Our Supply-Reach taxonomy and the modular design says which part to change. The source, transport and objective act on different properties (Table 12): the source sets the spectrum (logPSD $1.3$-$1.7 \\rightarrow 0.1$-$0.5$), the transport the proper score (ES $-11$ to $-12$%), and the objective the tail (a flatness term closes 93% of the kurtosis deficit on SHE-PAM; an amplitude-conditional term raises the lag-2 kurtosis ratio from 0.21 to 0.84 on GARD-LENS, with source and architecture unchanged).\n\nSo, to the question \"which part matters most\": no single part does. It depends on which property fails, and the protocol in our answer to W6 is how we decide.\n\n`[REVISION]` Add this statement and the GCS $\\rightarrow$ NCS comparison to the introduction; mark classical results.\n\n> *W4: The theory shows a transport exists, not that the network can learn it.*\n\nAgreed. Lemma 3 is an existence result and the paper does not guarantee that a finite network trained on finite data finds the transport. We will move this caveat from the appendix into Section 3. The limitation is shared by every learned sampler. What differs is how much must be learned. In NCS, the Gaussian part is supplied in closed form and the network learns the departure. Empirically, on controls with a known answer, the learned correction reaches it: $1.00\\times$ of the closed-form ceiling on the nonstationary control (see W5 for what was tested), and CRPS 0.60 vs. 1.13-1.16 for every classical arm when the conditional mean is nonlinear."+ },+ "createdAt": "2026-11-12T08:08:34.085Z",+ "modifiedAt": "2026-11-12T08:08:34.085Z",+ "url": "https://openreview.net/forum?id=aP806kHcn2¬eId=Zla60i4eM9",+ "license": "CC-BY-4.0"+}
reviews/openreview/ap806khcn2/submission.json added
+++ b/reviews/openreview/ap806khcn2/submission.json@@ -0,0 +1,20 @@+{+ "schema": "submission/1",+ "id": "aP806kHcn2",+ "venue": {+ "id": "ICLR.cc/2027/Conference",+ "name": "ICLR 2027",+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"+ },+ "number": 56979,+ "keywords": [+ "conditional simulation",+ "multi-fidelity learning",+ "stochastic PDEs",+ "proper scoring rules",+ "kriging",+ "probabilistic downscaling"+ ],+ "url": "https://openreview.net/forum?id=aP806kHcn2",+ "license": "CC-BY-4.0"+}
versions/v_nniwcfxg.json added
+++ b/versions/v_nniwcfxg.json@@ -0,0 +1,21 @@+{+ "date": "2026-09-19",+ "kind": "submitted",+ "label": "ICLR 2027",+ "submissions": [+ {+ "venue": "ICLR 2027",+ "status": "under_review",+ "number": 56979,+ "url": "https://openreview.net/forum?id=aP806kHcn2",+ "reviews": "openreview/ap806khcn2",+ "evidence": [+ "https://openreview.net/forum?id=aP806kHcn2"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=aP806kHcn2",+ "evidence": [+ "https://openreview.net/forum?id=aP806kHcn2"+ ]+}