potentialpaper

What Improves When a Microscopy Encoder Is Updated?

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:26 UTC · 50faa25501c8 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "SzmqQxQz3y"
- }
- ],
- "title": "What Improves When a Microscopy Encoder Is Updated?",
- "authors": [],
- "abstract": "Microscopy encoders support scientific measurements through classifiers,\nsegmentation decoders and measurement rules. We study which\nupdate gains survive the choice to co-train a head, leave it unchanged, or\nfit it afresh to frozen features. In matched dense-encoder forks across ten\nseeds, absolute task weighting leads normalization by 4.92 percentage points\nof culture balanced accuracy after 512 updates through co-trained heads and\n4.22 through unchanged source heads; fresh-head contrasts remain unresolved.\nThe preference is therefore measurable as compatibility with an existing\nclassifier. The co-trained--fresh interaction persists under fresh-optimizer\nand separate-clipping controls,\nbut equal-budget per-arm learning-rate tuning removes the early absolute\nadvantage. Later heads diverge in recipe ranking without meeting the\nprespecified criterion for a co-trained head hiding resolved accuracy loss.\nDINOv2-small does not reproduce the early preference at its default rates.\nSCOPE, a completed 4B-parameter microscopy model, supplies complementary\npositive evidence: an unchanged classifier improves from 0.6235 to 0.9798\non terminal features, and fresh fits also improve on the previously supervised\nculture task. On 23 held-out Allen plates, brightfield structure Dice is\n0.312, exceeding a 37M-parameter scratch control by 0.056; most of this capability\npredates continuation. Spatial controls show how decoder capacity and feature\naccess change the update contrast. On held-out larvae, improved counts\ncoexist with reduced strict object overlap, while a validation-based retention\ngate has no consistent advantage on external reporter assays. Most follow-ups\nreuse inspected panels. The study makes encoder progress interpretable through\nthe complete use: which readout changes, which labels and optimization it\nreceives, and which biological measurement the resulting procedure supports.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "7b150993-972a-454b-af56-c31991fcf749"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "What Improves When a Microscopy Encoder Is Updated?",
+ "authors": [],
+ "abstract": "Microscopy encoders support scientific measurements through classifiers,\nsegmentation decoders and measurement rules. We study which\nupdate gains survive the choice to co-train a head, leave it unchanged, or\nfit it afresh to frozen features. In matched dense-encoder forks across ten\nseeds, absolute task weighting leads normalization by 4.92 percentage points\nof culture balanced accuracy after 512 updates through co-trained heads and\n4.22 through unchanged source heads; fresh-head contrasts remain unresolved.\nThe preference is therefore measurable as compatibility with an existing\nclassifier. The co-trained--fresh interaction persists under fresh-optimizer\nand separate-clipping controls,\nbut equal-budget per-arm learning-rate tuning removes the early absolute\nadvantage. Later heads diverge in recipe ranking without meeting the\nprespecified criterion for a co-trained head hiding resolved accuracy loss.\nDINOv2-small does not reproduce the early preference at its default rates.\nSCOPE, a completed 4B-parameter microscopy model, supplies complementary\npositive evidence: an unchanged classifier improves from 0.6235 to 0.9798\non terminal features, and fresh fits also improve on the previously supervised\nculture task. On 23 held-out Allen plates, brightfield structure Dice is\n0.312, exceeding a 37M-parameter scratch control by 0.056; most of this capability\npredates continuation. Spatial controls show how decoder capacity and feature\naccess change the update contrast. On held-out larvae, improved counts\ncoexist with reduced strict object overlap, while a validation-based retention\ngate has no consistent advantage on external reporter assays. Most follow-ups\nreuse inspected panels. The study makes encoder progress interpretable through\nthe complete use: which readout changes, which labels and optimization it\nreceives, and which biological measurement the resulting procedure supports.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}