Separating Laboratory Values and Care Events in ICU Representation Learning
Update ICLR 2027 submission 7bXmwA8WT4: 1 note
@openreview[bot] · 2026-11-24 15:35 UTC · 655cab715e81 ·
reviews/openreview/7bxmwa8wt4/notes/9p0pocd6l4.json modified
+++ b/reviews/openreview/7bxmwa8wt4/notes/9p0pocd6l4.json@@ -8,17 +8,17 @@"content": {"paper_summary": "This paper investigates whether laboratory measurements and clinical care events should be represented separately in self-supervised learning from electronic health records (EHRs). The authors argue that conventional approaches may conflate information about patients' physiological states with information about clinical care processes, potentially limiting generalization across hospitals.\nTo address this issue, they propose a coupled architecture with separate encoders for laboratory values and care events, aligned through contrastive learning objectives.\nThe approach is evaluated on three ICU databases (MIMIC-IV, eICU, and HiRID), using eight downstream tasks and ten random seeds. The authors report statistically significant AUROC improvements over a single-stream baseline in 67 of 85 comparisons, with an average improvement of 0.019. Additional linear probing experiments demonstrate improved recoverability of laboratory values, including under cross-site and cross-database transfer. Ablation studies investigate the contributions of architectural separation and different contrastive objectives.\nOverall, the paper addresses a practically relevant problem and presents a comprehensive experimental evaluation.","presentation": 3,"informativeness": 2,- "soundness": 2,+ "soundness": 3,"critical_strengths": "1. The distinction between physiological measurements and clinical care processes is important for learning representations from observational healthcare data. Laboratory measurements provide information about patient physiology, whereas laboratory ordering patterns and medication initiation also reflect clinical decision-making, institutional policies, and healthcare workflows. The latter may differ substantially across hospitals and healthcare systems. Investigating whether these information sources should be modeled separately is therefore a relevant research question with potential implications for the robustness and transferability of EHR foundation models.\n\n2. A major strength is the extensive evaluation across three ICU databases: MIMIC-IV, eICU, and HiRID. The evaluation covers eight downstream prediction tasks, multiple random seeds, and cross-site and cross-database transfer settings. The reported improvements are consistent across most comparisons, suggesting that the proposed approach provides practical benefits over the selected single-stream baseline. The use of ten random seeds further strengthens the reliability of the experimental findings.\n\n3. The linear probing experiments are a particularly positive aspect of the work. Rather than evaluating representations exclusively through downstream predictive performance, the authors investigate how well laboratory values can be recovered from the learned embeddings. The reported improvements in laboratory-value recovery, including under cross-database transfer, provide complementary evidence about the information retained in the representations.\n\n4. The ablation experiments distinguish the contributions of encoder separation, laboratory set encoding, and different contrastive learning objectives. The observation that the cross-encoder contrastive objective primarily benefits downstream prediction, while not consistently improving laboratory-value recovery, is particularly interesting. It suggests that different architectural components influence representation properties in distinct ways.","critical_weaknesses": "1. My main concern relates to the methodological novelty and the positioning of the proposed approach relative to existing literature.\nIn particular, the claim that previous EHR Transformer models serialize heterogeneous patient records into a single token sequence is too general and overlooks previously published approaches that explicitly distinguish different types of EHR information. For example, ExMed-BERT (Lentzen et al., IEEE Journal of Biomedical and Health Informatics, 2023, DOI: 10.1109/JBHI.2023.3288768) represents different EHR information types through separate input sequences and corresponding embeddings before combining them within a shared Transformer architecture. Although this differs from the two-encoder design proposed in the present paper, it demonstrates that heterogeneous EHR information has previously been handled through structured, type-specific representations rather than through a single undifferentiated tokenization scheme.\n\n2. The experimental comparison against a conventional single-stream Transformer is relevant but insufficient to establish the advantages of the proposed design over existing approaches for representing heterogeneous EHR data. In particular, the paper should consider architectures that employ type-specific embeddings followed by a shared Transformer, as well as other multimodal fusion strategies such as separate encoders with intermediate fusion or cross-attention. This distinction is important because the proposed approach changes several aspects of the architecture simultaneously: the separation of input streams, the encoding of laboratory values, the representation capacity, and the contrastive training objectives.\n\n3. Another concern is the apparent lack of systematic hyperparameter optimization. The proposed architecture introduces several design choices, including encoder configurations, representation dimensionality, the weighting of contrastive objectives, and potentially contrastive temperature parameters. The performance of contrastive representation-learning methods can be sensitive to these choices.\nIt is therefore important to establish whether the proposed architecture and the single-stream baseline were optimized under comparable computational budgets. The extensive evaluation across ten random seeds is commendable, but repeated training with different random initializations does not substitute for hyperparameter optimization.\n\n4. The central motivation is that physiological measurements and clinical care events capture different aspects of the patient record, with care processes being more dependent on institutional practices. While the experiments demonstrate improved downstream prediction and cross-database transfer, they do not directly establish that these gains arise from reduced dependence on hospital-specific care processes. For example, it has not been tested whether learned representations allow to predict the hospital or site from which data was collected.\n\n5. The linear probing experiments show improved recoverability of laboratory values from the proposed representations. While this is encouraging, the interpretation requires some caution. Because laboratory values are explicitly processed by a dedicated encoder, improved recovery of these measurements is not entirely unexpected. It remains unclear to what extent the observed improvements reflect a more meaningful representation of patient physiology rather than the preservation of information that is directly supplied to the laboratory encoder.\n\n6. The ablation results suggest that different components contribute differently to laboratory-value recovery and downstream prediction. In particular, the cross-encoder contrastive objective appears to improve predictive performance without consistently improving laboratory-value recovery. This is an interesting finding that deserves further investigation.\n\nAdditional considerations:\n- Although the reported improvements are statistically significant in most comparisons, the mean absolute AUROC gain of 0.019 is relatively modest. The authors should contextualize its practical relevance and provide appropriate confidence intervals and effect-size analyses.\n\n- Given the 85 reported comparisons, the paper should clearly explain how statistical significance was assessed and whether appropriate corrections for multiple testing were applied. Dependencies between tasks, datasets, and seeds should also be considered.\n\n- The proposed architecture introduces additional encoders and contrastive objectives. Reporting parameter counts, training time, and computational requirements would help assess the practical trade-off between model complexity and predictive performance.","questions_for_authors": "1. What is the precise methodological novelty of the proposed architecture relative to existing modality-specific and multi-view EHR representation-learning approaches?\n2. Can the authors compare their approach against a shared Transformer with modality-specific embeddings, as well as other established multimodal fusion architectures, under comparable model capacities and training budgets?\n3. How were the hyperparameters selected? Were the proposed model and the baseline subjected to comparable hyperparameter optimization procedures?\n4. Can the authors provide more direct evidence that the improved cross-site and cross-database performance results specifically from separating patient physiology and institutional care processes?\n5. To what extent are improvements in laboratory-value recovery explained by the dedicated laboratory encoder rather than by the contrastive learning objectives?\n6. How were statistical significance tests across the 85 comparisons performed, and were multiple comparisons appropriately accounted for?\n7. Will the code, preprocessing procedures, and experimental configurations be made publicly available?","flag_for_ethics_review": "No",- "rating": 2,+ "rating": 3,"confidence": 3},"createdAt": "2026-10-19T09:14:17.415Z",- "modifiedAt": "2026-11-17T11:09:38.346Z",+ "modifiedAt": "2026-11-24T08:39:02.814Z","url": "https://openreview.net/forum?id=7bXmwA8WT4¬eId=9P0pOcD6L4","license": "CC-BY-4.0"}