Harness²: Evaluating Coding-Agent Memory After a Reset
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:30 UTC · 548030472673 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "MUAJguyvAD"- }- ],- "title": "Harness²: Evaluating Coding-Agent Memory After a Reset",- "authors": [],- "abstract": "A coding agent receives a stored code change to help repair its next program. The resulting recovery score is taken as a verdict on what the memory transfers. The harness can settle that verdict before a program reaches the verifier. On two held-out functions at a 16,384-token per-call cap, 19 of 24 episodes at extra-high reasoning effort emit no program; forced closure prevents an observed end-token failure mode on Qwen3.8-27B-FP8. We introduce Harness² (Harness of Harnesses), which starts from a failing program, excludes prior interactions and the target solution, and compares reference-derived banks with the task, seed, model, verifier, and execution limits held fixed. On 60 completed PACE-Bench task–seed units, a sibling reference change resolves 23 episodes versus 22 with no bank: 12 paired wins, 11 losses, and 37 ties, a difference of 1/60. A character-matched unrelated bank resolves 21, while direct patch application and whole-program transplant both fail on the tested cross-task transfers. Recovery is reported beside the output tokens consumed by the same evaluated episodes, excluding earlier executions that were replaced: the bank is evaluated through the harness that reads it.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "3704513b-e4a0-46d3-8e29-c7bd041cd912"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "Harness²: Evaluating Coding-Agent Memory After a Reset",+ "authors": [],+ "abstract": "A coding agent receives a stored code change to help repair its next program. The resulting recovery score is taken as a verdict on what the memory transfers. The harness can settle that verdict before a program reaches the verifier. On two held-out functions at a 16,384-token per-call cap, 19 of 24 episodes at extra-high reasoning effort emit no program; forced closure prevents an observed end-token failure mode on Qwen3.8-27B-FP8. We introduce Harness² (Harness of Harnesses), which starts from a failing program, excludes prior interactions and the target solution, and compares reference-derived banks with the task, seed, model, verifier, and execution limits held fixed. On 60 completed PACE-Bench task–seed units, a sibling reference change resolves 23 episodes versus 22 with no bank: 12 paired wins, 11 losses, and 37 ties, a difference of 1/60. A character-matched unrelated bank resolves 21, while direct patch application and whole-program transplant both fail on the tested cross-task transfers. Recovery is reported beside the output tokens consumed by the same evaluated episodes, excluding earlier executions that were replaced: the bank is evaluated through the harness that reads it.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}