potentialpaper

SN-ABSTOPK: AN UNROLLED SPATIAL-NORMATIVE SPARSE AUTOENCODER FOR MEDICAL FOUNDATION MODELS

Name the authors, now that its review has ended

potentialpaper · 2026-11-24 18:35 UTC · c9b403920761 ·

paper.json modified

+++ b/paper.json
@@ -1,7 +1,13 @@
{
"title": "SN-ABSTOPK: AN UNROLLED SPATIAL-NORMATIVE SPARSE AUTOENCODER FOR MEDICAL FOUNDATION MODELS",
- "authors": [],
+ "authors": [
+ "Abdullah",
+ "Haider Ali",
+ "Tao Huang",
+ "Ickjai Lee",
+ "Euijoon Ahn"
+ ],
"abstract": "Sparse autoencoders (SAEs) decompose foundation model representations into\nmonosemantic latents. However, applying independent per-token sparsity across\nimage grids ignores spatial correlations, which causes feature fragmentation in\nmedical imaging. We introduce Spatial-Normative AbsTopK (SN-AbsTopK), an\nunrolled sparse autoencoder that integrates spatial group support containment and\nnormative reference centering into signed-magnitude dictionary learning. Rather\nthan evaluating tokens independently, SN-AbsTopK operates via a two-stage se-\nlection mechanism across spatial token groups. This structure enables effective\nprocessing across continuous regions, such as contiguous histology tiles or vol-\numetric MRI slice stacks. In the first stage, the model aggregates pre-activation\ncolumn energies across all group tokens to rank dictionary atoms and establish a\nshared group candidate support. In the second stage, each individual token se-\nlects its active signed features strictly from within this shared group candidate\npool. This guarantees that all token-level active features remain strict subsets\nof the group candidate set. To isolate disease-specific variations, an exponential\nmoving average reference buffer first centers the input embeddings. This pro-\ncess forces the sparse latent codes to represent residual departures from base-\nline reference states. Evaluated across histopathology (BCSS with frozen UNI)\nand radiology (CheXpert and Duke Breast MRI with frozen BiomedCLIP), SN-\nAbsTopK substantially enhances structural continuity, increasing spatial autocor-\nrelation by 2.9× on BCSS (Moran’s 0.244 vs. 0.084) and 3D adjacent-slice sup-\nport persistence by 60.7% on Duke MRI (Jaccard 0.614 vs. 0.382). Although\nstrict candidate bounds increase reconstruction error and cause feature lock-out\n( 80% dead atoms), raw reconstruction error proves decoupled from clinical de-\ncodability. Consequently, SN-AbsTopK yields superior downstream linear probe\nperformance (+0.085 macro-AUROC on CheXpert; +0.033 on Duke MRI).",
"license": {
"metadata": "CC0-1.0",
"abstract": "CC0-1.0"