potentialpaper

SFT Leaves a Reproducible Signature in Activation Geometry: Calibrating Post-Training Interpretability Against Run-to-Run Noise

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:30 UTC · a61f3371ddbd ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "spoAN16IXS"
- }
- ],
- "title": "SFT Leaves a Reproducible Signature in Activation Geometry: Calibrating Post-Training Interpretability Against Run-to-Run Noise",
- "authors": [],
- "abstract": "A model diff credits post-training with whatever separates a base checkpoint from one post-trained descendant, presuming a rerun would land close by. On the sparse co-activation graph of Qwen3-1.7B it does not: two LoRA-SFT reruns sit over half as far apart as either sits from the base. We score each base-to-post contrast against its own recipe’s run-to-run band, and show that under run exchangeability k runs certify no better than p ≤ 1/(k + 1) however large the effect, so the band’s z is a descriptive scale. SFT leaves a large, reproducible signature: base→SFT displaces the graph by 19.9 pairwise-distance SDs beyond the mean distance between four independent LoRA-SFT runs, and the pre-registered estimator replicates on Llama-3.1-8B with Llama-Scope. At an identical 29 steps, four SFT and four DPO runs occupy disjoint displacement ranges, a gap 5.3× either arm’s spread, without any band. Three other readings stop short of a verdict: DPO’s band membership is dose-dependent (0/4, 2/4, 4/4 contrasts outside at 12, 29, 60 steps) while its displacement stays flat; light GRPO is a secondary non-detection, not an absence, and we run no equivalence test; and the graph concentration read as an RL signature is already in the zero-RL base, and a dictionary-width control removes an apparent scaling law in it. A pre-registered causal sweep (three edge budgets, 4,816 held-out prompts) found the displaced sources load-bearing (12× a matched random control in mean, 3.5× in median at 10,000 edges), but their stage-specificity interaction reversed at two budgets and the third failed its faithfulness gate, so we claim calibrated structural displacement, not a changed mechanism. Model diffs should be read beside their recipe’s rerun band, within-band diffs as non-detections. Scope: the full detection protocol covers one backbone (Qwen3-1.7B), one SFT recipe and general-text probe states; the matched-base control replicates across three families.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "3992c35d-6cfa-4df6-b4be-d2ddf4d9574c"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "SFT Leaves a Reproducible Signature in Activation Geometry: Calibrating Post-Training Interpretability Against Run-to-Run Noise",
+ "authors": [],
+ "abstract": "A model diff credits post-training with whatever separates a base checkpoint from one post-trained descendant, presuming a rerun would land close by. On the sparse co-activation graph of Qwen3-1.7B it does not: two LoRA-SFT reruns sit over half as far apart as either sits from the base. We score each base-to-post contrast against its own recipe’s run-to-run band, and show that under run exchangeability k runs certify no better than p ≤ 1/(k + 1) however large the effect, so the band’s z is a descriptive scale. SFT leaves a large, reproducible signature: base→SFT displaces the graph by 19.9 pairwise-distance SDs beyond the mean distance between four independent LoRA-SFT runs, and the pre-registered estimator replicates on Llama-3.1-8B with Llama-Scope. At an identical 29 steps, four SFT and four DPO runs occupy disjoint displacement ranges, a gap 5.3× either arm’s spread, without any band. Three other readings stop short of a verdict: DPO’s band membership is dose-dependent (0/4, 2/4, 4/4 contrasts outside at 12, 29, 60 steps) while its displacement stays flat; light GRPO is a secondary non-detection, not an absence, and we run no equivalence test; and the graph concentration read as an RL signature is already in the zero-RL base, and a dictionary-width control removes an apparent scaling law in it. A pre-registered causal sweep (three edge budgets, 4,816 held-out prompts) found the displaced sources load-bearing (12× a matched random control in mean, 3.5× in median at 10,000 edges), but their stage-specificity interaction reversed at two budgets and the third failed its faithfulness gate, so we claim calibrated structural displacement, not a changed mechanism. Model diffs should be read beside their recipe’s rerun band, within-band diffs as non-detections. Scope: the full detection protocol covers one backbone (Qwen3-1.7B), one SFT recipe and general-text probe states; the matched-base control replicates across three families.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}