potentialpaper

OlfactorySearchRL: A Measured-Plume Benchmark for Learning to Navigate by Smell

Update ICLR 2027 submission RvGmPvo58R: 1 note

@openreview[bot] · 2026-11-25 22:26 UTC · 4ccf46b2db64 ·

Evidence

reviews/openreview/rvgmpvo58r/notes/erpsazzcse.json modified

+++ b/reviews/openreview/rvgmpvo58r/notes/erpsazzcse.json
@@ -14,12 +14,19 @@
"critical_weaknesses": "* The measurements used, seem quite limited: \"The evaluated split uses six recordings for training and three for testing\", so 9 sequences in total. The geometry is not explicitly mentioned, but based on the figures seems to be a small open space. The plumes seem to have some turbulence, judging on the images, but it is not exactly clear which ones are from the real measurements? All, also in Fig 1 bottom right? Hence, the question is how well methods trained on this dataset will generalize. Also, if one wants to incorporate different measurements, they may be made with a very different sensing setup, etc., so it may not be compatible... this can severely limit the usefulness of the proposed modular framework for others.\n* The real experiments are also quite limited: (a) the space is small (4x2m) and is completely open, making the odor probably spread mostly by diffusion, (b) it is not clear what kind of wind is present in the space, and in any case \"wind is prescribed\", meaning not measured on the robot - indeed, measuring the air flow would be challenging, especially for low air flows typically experienced indoors.",
"questions_for_authors": "- Eq. 2: What is the recording index if not the time? Shouldn't kt also be present on the left side?\n- \"The source concentration is set to 20ppm\": What does this mean? I thought this was measured? Or did you normalize with respect to this value?\n- What is the size of the environment that was measured with PLIF?\n- What form does the wind-conditioning take for the belief update?\n- \"we connect a learned controller to a mobile robot searching ...\" -> Which learned controller? Belief-RNN-PPO?\n- How does the work relate to other benchmarks? For example, GSL-bench uses simulated flow and odor source spreading to simulate larger scale spaces with obstacles: Erwich, H. H., Duisterhof, B. P., & de Croon, G. C. (2024, May). Gsl-bench: High fidelity gas source localization benchmarking tool. In 2024 IEEE International Conference on Robotics and Automation (ICRA) (pp. 17672-17678). IEEE. There is a clear difference, as it is not based on real measurements. However, it was also validated with preliminary work with small drones. \n- \"Gas measurements acquired near 1 kHz are filtered and decimated to 20 Hz, then converted to a baseline-relative proxy.\" What are the dynamics of the sensor? The sampling frequency may be high, but how fast does the measurement go up when concentration goes up, and how fast does it go down when the specific gas is gone? So what are the dynamics there?",
"flag_for_ethics_review": "No",
"details_of_ethics_concerns": "No concerns.",
- "rating": 2,
+ "rating": 3,
"confidence": 3
},
"createdAt": "2026-10-14T15:48:11.511Z",
- "modifiedAt": "2026-11-06T12:40:51.369Z",
+ "modifiedAt": "2026-11-25T21:53:48.765Z",
"url": "https://openreview.net/forum?id=RvGmPvo58R&noteId=eRpsazZcse",
- "license": "CC-BY-4.0"
+ "license": "CC-BY-4.0",
+ "scoreChanges": [
+ {
+ "field": "rating",
+ "from": 2,
+ "at": "2026-11-25T22:26:16.237Z"
+ }
+ ]
}