Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:30 UTC · cecdff45cc94 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "JVPXpPbwoT"- }- ],- "title": "DelibRRG: Trustworthy Cross-Examination and Clinical-First Deliberation for Radiology Report Generation",- "authors": [],- "abstract": "Radiology report generation (RRG) aims to generate accurate and standardized diagnostic descriptions from medical images. Existing methods improve report quality through stronger representation learning and cross-modal interaction, but typically lack a stable clinical reference and an explicit mechanism for coordinating diagnostic and linguistic objectives. As a result, diagnostic roles may lose functional distinction during semantic interaction, while clinical fact preservation can be weakened by competing generation objectives. Inspired by information structure theory and multi-expert decision-making, we propose Trustworthy Cross-Examination and Clinical-First **Delib**eration for **R**adiology **R**eport **G**eneration (**DelibRRG**), which reformulates RRG as a clinical deliberation process organized by clinical reference establishment, heterogeneous role interaction, and asymmetric coordination. DelibRRG first employs dual-space structural calibration to construct a trustworthy clinical reference by calibrating candidate cross-modal correspondences through neighborhood consensus. It then constructs functionally decoupled clinical and semantic streams that exchange complementary information through controlled bidirectional cross-examination, followed by training-time clinical review of the updated diagnostic representation. Finally, clinical-first asymmetric bargaining assigns unequal bargaining power and a clinical disagreement point to bias joint optimization toward clinical fact preservation. Experiments on MIMIC-CXR and IU-Xray demonstrate strong report generation performance, while the clinical efficacy gains on MIMIC-CXR suggest improved clinical factual accuracy.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "3b67e368-705f-4162-99ca-e0cdc1b087da"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "DelibRRG: Trustworthy Cross-Examination and Clinical-First Deliberation for Radiology Report Generation",+ "authors": [],+ "abstract": "Radiology report generation (RRG) aims to generate accurate and standardized diagnostic descriptions from medical images. Existing methods improve report quality through stronger representation learning and cross-modal interaction, but typically lack a stable clinical reference and an explicit mechanism for coordinating diagnostic and linguistic objectives. As a result, diagnostic roles may lose functional distinction during semantic interaction, while clinical fact preservation can be weakened by competing generation objectives. Inspired by information structure theory and multi-expert decision-making, we propose Trustworthy Cross-Examination and Clinical-First **Delib**eration for **R**adiology **R**eport **G**eneration (**DelibRRG**), which reformulates RRG as a clinical deliberation process organized by clinical reference establishment, heterogeneous role interaction, and asymmetric coordination. DelibRRG first employs dual-space structural calibration to construct a trustworthy clinical reference by calibrating candidate cross-modal correspondences through neighborhood consensus. It then constructs functionally decoupled clinical and semantic streams that exchange complementary information through controlled bidirectional cross-examination, followed by training-time clinical review of the updated diagnostic representation. Finally, clinical-first asymmetric bargaining assigns unequal bargaining power and a clinical disagreement point to bias joint optimization toward clinical fact preservation. Experiments on MIMIC-CXR and IU-Xray demonstrate strong report generation performance, while the clinical efficacy gains on MIMIC-CXR suggest improved clinical factual accuracy.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}