potentialpaper

Fully Open Meditron: Auditable and Reproducible Development of Clinical LLMs

Import ICLR 2027 submission fnyCAs5h4Q: 30 notes

@openreview[bot] · 2026-11-22 21:29 UTC · 3224dd6f1f56

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,19 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "fnyCAs5h4Q"
+ }
+ ],
+ "title": "Fully Open Meditron: Auditable and Reproducible Development of Clinical LLMs",
+ "authors": [],
+ "abstract": "Clinical decision-support LLMs are either proprietary or open-weight, without the training data and development pipelines required for end-to-end reproducibility and auditing. We investigate how much of the gap between fully-open and open-weight clinical specialists is closeable under full-openness constraints. We introduce MeditronFO (Meditron Fully Open), to our knowledge, the first fully-open pipeline for clinical LLM finetuning. The pipeline creates three new synthetic datasets (340k QA pairs) from clinician-authored adversarial vignettes, clinical practice guidelines and public medical QA, using open-weight gpt-oss-120b for rejection-sampling distillation with pass@8, with generation prompts co-authored by a panel of four clinicians. We apply the pipeline to five fully-open base models from three families and one open-weight control (Gemma-3-27B). On the average of five medical benchmarks, Apertus-70B-MeditronFO reaches 54.56\\%, against 48.35\\% for Apertus-70B-Instruct and 63.75\\% for MedGemma-27B, closing 40\\% of the gap; the Gemma-3-27B-MeditronFO control reaches 58.65\\%. We also introduce AutoMOOVE, an automated open-ended clinician preference benchmark, whose judgments agree with blinded clinicians' preferences ($\\kappa = 0.564$). The Gemma-3-27B-MeditronFO control is level with or ahead of MedGemma-27B on this benchmark (57.1\\% win rate under a three-judge majority vote, above parity under two of three judges). We release the data, code and model weights as public artifacts.",
+ "year": 2027,
+ "venue": "ICLR 2027 (under review)",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://potentialpaper.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://potentialpaper.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/fnycas5h4q/forms.json added

+++ b/reviews/openreview/fnycas5h4q/forms.json
@@ -0,0 +1,183 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "additional_comments_on_reviewer_discussion",
+ "label": "Reviewer discussion",
+ "type": "text"
+ },
+ {
+ "key": "recommendation",
+ "label": "Recommendation",
+ "type": "choice"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "soundness",
+ "presentation",
+ "informativeness"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "soundness",
+ "label": "Soundness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "presentation",
+ "label": "Presentation",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "informativeness",
+ "label": "Informativeness",
+ "type": "score",
+ "min": 1,
+ "max": 3
+ },
+ {
+ "key": "paper_summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "critical_strengths",
+ "label": "Strengths",
+ "type": "text"
+ },
+ {
+ "key": "critical_weaknesses",
+ "label": "Weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions_for_authors",
+ "label": "Questions for the authors",
+ "type": "text"
+ },
+ {
+ "key": "flag_for_ethics_review",
+ "label": "Flag for ethics review",
+ "type": "choice",
+ "omitWhen": [
+ "No",
+ "No ethics review needed."
+ ]
+ },
+ {
+ "key": "details_of_ethics_concerns",
+ "label": "Ethics concerns",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/1wwfcddewh.json added

+++ b/reviews/openreview/fnycas5h4q/notes/1wwfcddewh.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "1WwFCDdEWh",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q2a: What is the composition of the clinician-rated response pairs before filtering for unanimous preferences, including the models represented? How well do the judges agree with clinicians on disputed pairs?",
+ "comment": "We have investigated this by looking at inter-annotator-agreement on comparisons that have 2+ raters, including the comparisons that are not unanimous. On the 1325 samples in this set, a clinician agrees with the clinician majority at kappa=0.309. Our LLM judge agrees with the clinician majority at kappa=0.361, so at least as well as clinicians agree with each other (added as table 17 in Appendix I.2).\n\n| **Cohen's κ (agreement %)** | **All pairs (1,325)** | **Unanimous (576)** |\n| --- | --- | --- |\n| Clinician vs. clinician | 0.223 \\[0.188, 0.259\\] (51.4%) | 1 (by construction) |\n| Gemma-4-31B vs. each clinician | 0.281 \\[0.252, 0.311\\] (55.8%) | 0.593 \\[0.531, 0.653\\] (77.0%) |\n| Clinician vs. majority of the other clinicians | 0.309 \\[0.267, 0.350\\] (58.0%) | 1 (by construction) |\n| Gemma-4-31B vs. majority of the other clinicians | 0.361 \\[0.322, 0.400\\] (61.6%) | 0.595 \\[0.532, 0.655\\] (77.1%) |\n\nFor AutoMOOVE validation, we use pairs where the clinician panel agrees unanimously, since they give a clear signal to assess the quality of the judge. On this subset (576 pairs) the LLM judge reaches kappa=0.593, “moderate agreement” according to Landis & Koch (1977) conventions.\n\nAs requested, here is the composition of the clinician-rated response pairs before and after filtering:\n\n| | **All pairs** | **Unanimous** | **% unanimous** |\n| --- | --- | --- | --- |\n| Pairs | 1,325 | 576 | 43% |\n| Clinicians | 200 | 181 | — |\n\nBy model: (Cohen's κ (agreement %))\n\n| **Model** | **Pairs (all / unanimous)** | **Clinician vs. other clinicians, all pairs** | **Gemma-4-31B vs. other clinicians, all pairs** | **Gemma-4-31B, unanimous pairs** |\n| --- | --- | --- | --- | --- |\n| Meditron3-70B | 785 / 332 | 0.291 (57.5%) | 0.364 (62.5%) | 0.627 (79.8%) |\n| Meditron-DPO | 442 / 201 | 0.338 (60.9%) | 0.449 (68.5%) | 0.671 (82.3%) |\n| GPT-4o | 258 / 136 | 0.374 (62.6%) | 0.424 (66.5%) | 0.657 (80.8%) |\n| Gemini-2.0-Flash | 219 / 101 | 0.327 (58.5%) | 0.385 (62.7%) | 0.596 (78.0%) |\n| MedGemma-27B | 171 / 75 | 0.284 (56.1%) | 0.381 (61.6%) | 0.605 (75.6%) |\n| DeepSeek-V3 | 160 / 74 | 0.343 (59.7%) | 0.434 (65.6%) | 0.593 (76.4%) |\n| Llama-3.3-70B | 144 / 63 | 0.350 (58.5%) | 0.309 (58.2%) | 0.463 (69.9%) |\n| Claude-3.7-Sonnet | 133 / 58 | 0.319 (58.2%) | 0.270 (55.8%) | 0.474 (70.5%) |\n| All | 1,325 / 576 | 0.309 (58.0%) | 0.361 (61.6%) | 0.595 (77.1%) |"
+ },
+ "createdAt": "2026-11-14T17:24:57.338Z",
+ "modifiedAt": "2026-11-14T17:24:57.338Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=1WwFCDdEWh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/59ft8rfegx.json added

+++ b/reviews/openreview/fnycas5h4q/notes/59ft8rfegx.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "59Ft8RFeGX",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer xFAx",
+ "content": {
+ "paper_summary": "The paper introduces MeditronFO, a pipeline designed to support transparent and reproducible development of fully open medical language models. It constructs training data from public medical question-answer datasets and synthetic examples derived from those datasets, clinical guidelines, and clinician-written vignettes. Fine-tuning improves medical benchmark performance to varying degrees across models and tasks, while reducing general-purpose performance in some models. The paper also introduces AutoMOOVE, which uses LLM judges to compare responses to clinical vignettes and assesses their agreement with clinician preferences. Its main contribution is the proposed release of training data, development code, and model weights, together with an evaluation framework for medical responses.",
+ "presentation": 2,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "- The paper provides generation prompts, summaries of the filtering process, training hyperparameters, and compute details. If the artifacts are released as described, they could provide a useful baseline for fully open medical LLM development.\n\n- The paper reports mixed results and limitations, including no statistically significant improvement in average MCQA performance for the EuroLLM and Gemma-3 models, IFEval declines for several models, and smaller HealthBench gains after length adjustment. The authors also attribute much of the observed MMLU-Pro improvement to changes in answer format.\n\n- The paper documents evaluation sensitivities through AutoMOOVE analyses across judges, tie-handling rules, answer orders, and response lengths. For HealthBench, it compares its scores for the teacher model with published scores and regrades the teacher’s answers using an additional grader.",
+ "critical_weaknesses": "- The Gemma-based MeditronFO model shows no statistically significant improvement in average MCQA performance, loses ground after HealthBench length adjustment, and exhibits greater general-purpose degradation than MedGemma relative to the same base. These results limit the evidence for the recipe’s effectiveness across model families.\n\n- Fine-tuned models produce longer answers, and length adjustment substantially reduces several reported improvements, reversing some into losses. This complicates the interpretation of the raw scores, although it does not establish that longer answers alone caused the gains.\n\n- Some component ablations show benefits, but the effects vary across datasets, model sizes, and evaluation metrics. The component ablations have limited replication, leaving their robustness to training variability uncertain.\n\n- Judge agreement is assessed on answer pairs with unanimous clinician preferences, leaving performance on disputed cases untested. Results also show sensitivity to the judge, answer order, and response length. Without clinician evaluation of the newly compared model responses, the reported preferences require cautious interpretation.",
+ "questions_for_authors": "- Which guideline sources were used, and which source materials, including guideline texts, MOOVE seed vignettes, and clinician preference labels, will be released under what terms? Please also clarify the scope of the “fully open” claim given the pipeline’s reliance on an open-weight teacher.\n\n- What is the composition of the clinician-rated response pairs before filtering for unanimous preferences, including the models represented? How well do the judges agree with clinicians on disputed pairs, and is clinician evaluation available for the model comparisons reported in this paper?\n\n- During answer distillation for Guidelines QA, does the teacher receive the source guideline? How is correctness checked beyond agreement with the generated answer label, and was the final corpus re-audited by clinicians after the pipeline revisions?\n\n- What are the answer-parsing failure rates for base and fine-tuned models on the medical MCQA benchmarks, and are the conclusions robust to alternative answer extraction? Were any hyperparameters or checkpoints selected using medical benchmark performance, and if so, which data splits were used?",
+ "flag_for_ethics_review": "No",
+ "rating": 2,
+ "confidence": 3
+ },
+ "createdAt": "2026-10-21T12:02:54.554Z",
+ "modifiedAt": "2026-11-06T12:41:02.393Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=59Ft8RFeGX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/89ga6mef56.json added

+++ b/reviews/openreview/fnycas5h4q/notes/89ga6mef56.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "89gA6MeF56",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W2b: AutoMOOVE is validated on 576 historical response pairs selected for unanimous clinician agreement. These checks provide useful evidence, but leave uncertainty about the final corpus’s error rate and clinician agreement with the new model comparisons.",
+ "comment": "A blinded clinician evaluation of the new model comparisons is being conducted with our clinical partners and will be published in a separate study. Meanwhile, we have extended the AutoMOOVE validation beyond unanimous pairs (now Appendix I.2 in the PDF, table 17). On all 1,325 historical pairs with 2+ clinician ratings, including disputed ones, our judge agrees with the clinician majority at κ=0.361, compared with κ=0.309 for a clinician with the clinician majority. Agreement holds across the eight model families in the pool.\n\n| **Cohen's κ (agreement %)** | **All pairs (1,325)** | **Unanimous (576)** |\n| --- | --- | --- |\n| Clinician vs. clinician | 0.223 \\[0.188, 0.259\\] (51.4%) | 1 (by construction) |\n| Gemma-4-31B vs. each clinician | 0.281 \\[0.252, 0.311\\] (55.8%) | 0.593 \\[0.531, 0.653\\] (77.0%) |\n| Clinician vs. majority of the other clinicians | 0.309 \\[0.267, 0.350\\] (58.0%) | 1 (by construction) |\n| Gemma-4-31B vs. majority of the other clinicians | 0.361 \\[0.322, 0.400\\] (61.6%) | 0.595 \\[0.532, 0.655\\] (77.1%) |\n\n| **Model** | **Pairs (all / unanimous)** | **Clinician vs. other clinicians, all pairs** | **Gemma-4-31B vs. other clinicians, all pairs** | **Gemma-4-31B, unanimous pairs** |\n| --- | --- | --- | --- | --- |\n| Meditron3-70B | 785 / 332 | 0.291 (57.5%) | 0.364 (62.5%) | 0.627 (79.8%) |\n| Meditron-DPO | 442 / 201 | 0.338 (60.9%) | 0.449 (68.5%) | 0.671 (82.3%) |\n| GPT-4o | 258 / 136 | 0.374 (62.6%) | 0.424 (66.5%) | 0.657 (80.8%) |\n| Gemini-2.0-Flash | 219 / 101 | 0.327 (58.5%) | 0.385 (62.7%) | 0.596 (78.0%) |\n| MedGemma-27B | 171 / 75 | 0.284 (56.1%) | 0.381 (61.6%) | 0.605 (75.6%) |\n| DeepSeek-V3 | 160 / 74 | 0.343 (59.7%) | 0.434 (65.6%) | 0.593 (76.4%) |\n| Llama-3.3-70B | 144 / 63 | 0.350 (58.5%) | 0.309 (58.2%) | 0.463 (69.9%) |\n| Claude-3.7-Sonnet | 133 / 58 | 0.319 (58.2%) | 0.270 (55.8%) | 0.474 (70.5%) |\n| All | 1,325 / 576 | 0.309 (58.0%) | 0.361 (61.6%) | 0.595 (77.1%) |\n\nThese comparisons do not include the new MeditronFO outputs, so this supports the judge’s reliability but we agree that this does not replace clinician review of the new comparisons. We added in Section 7 (Limitations) that AutoMOOVE win rates are not a replacement for direct clinician validation. As complementary evidence, we also provide HealthBench meta-evaluation results of our grader. On the  meta-evaluation, our grader reaches macro F1 0.698 \\[0.692, 0.705\\], against 0.672 for physicians compared with each other (added in Appendix H.1)."
+ },
+ "createdAt": "2026-11-14T17:20:14.218Z",
+ "modifiedAt": "2026-11-14T17:20:14.218Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=89gA6MeF56",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/8lktyfy7fj.json added

+++ b/reviews/openreview/fnycas5h4q/notes/8lktyfy7fj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "8lkTYFY7FJ",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W3: Some component ablations show benefits, but the effects vary across datasets, model sizes, and evaluation metrics. The component ablations have limited replication, leaving their robustness to training variability uncertain.",
+ "comment": "We added replication results of the two recipes at 70b. Those replication results show that the curatedQA ablation exceeds the noise of the run to run noise. The gpt-oss-120b replication differs from the original run by −0.65 MCQA points \\[−1.58, +0.26\\] and +0.2 points on HealthBench (Table 24), and the Qwen3.8 replicate by +0.44 and −0.6 points (Table 25)."
+ },
+ "createdAt": "2026-11-14T17:22:37.894Z",
+ "modifiedAt": "2026-11-14T17:22:37.894Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=8lkTYFY7FJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/9eyscxfdws.json added

+++ b/reviews/openreview/fnycas5h4q/notes/9eyscxfdws.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "9EYsCxFdWs",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W2: Fine-tuned models produce longer answers, and length adjustment substantially reduces several reported improvements, reversing some into losses.",
+ "comment": "We agree that it is important to control for length bias and we report the results in Section 5.4 and Table 14. After length adjustment from OpenAI provided evaluation code, the HealthBench gain remains significant for Apertus-70B (+10.0 → +4.6), Apertus-8B (+16.1 → +6.1), OLMo-2-32B (+15.0 → +9.1) and EuroLLM-9B (+15.3 → +8.0), but becomes a loss for EuroLLM-22B (−3.3) and Gemma-3-27B (−1.4). We find that on AutoMOOVE, the judge’s preference is not correlated with answer length for Apertus-70B (Table 19). We have added length-controlled teacher distillation as future work in Section 7."
+ },
+ "createdAt": "2026-11-14T17:22:18.163Z",
+ "modifiedAt": "2026-11-14T17:22:18.163Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=9EYsCxFdWs",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/a560qsfoxf.json added

+++ b/reviews/openreview/fnycas5h4q/notes/a560qsfoxf.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "A560qSFOXF",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q3: Did the authors exclude held-out benchmark items from the Curated QA exemplar pool before synthetic question generation, in addition to decontaminating the final corpus?",
+ "comment": "Yes, we ran decontamination on the CuratedQA set before the synthetic question generation. No synthetic question was generated with a test question as seed."
+ },
+ "createdAt": "2026-11-14T17:17:43.053Z",
+ "modifiedAt": "2026-11-14T17:17:43.053Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=A560qSFOXF",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/aswgp3uhf6.json added

+++ b/reviews/openreview/fnycas5h4q/notes/aswgp3uhf6.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ASWgp3uhF6",
+ "replyTo": "w6o2OJAt7z",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q1: Has the revised final corpus undergone an independent clinician audit distinct from the original 60-item audit? Please clarify the sampling procedure and residual factual, unsafe-recommendation, and label/rationale-consistency findings. If such evidence is not available, a limited stratified audit of the final synthetic components would materially affect the assessment of the resource.",
+ "comment": "A clinician re-audit of the final corpus is under way. The audit is stratified by component. Clinicians are reviewing 20 randomly sampled items from each of the Guidelines QA and Synthetic MCQA datasets of the final corpus. They rate each item as Wrong, Partly Wrong, Partly Correct, or Correct, and label Wrong and Partly Wrong items as Unsafe recommendation, Factual error, Unclear information or other. We agree that the LLM screening flags should not be read as an estimate of residual error. We now state this in Section 2.3."
+ },
+ "createdAt": "2026-11-14T17:27:33.627Z",
+ "modifiedAt": "2026-11-14T17:27:33.627Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=ASWgp3uhF6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/az8yyt72q7.json added

+++ b/reviews/openreview/fnycas5h4q/notes/az8yyt72q7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "aZ8Yyt72q7",
+ "replyTo": "ASWgp3uhF6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q1: Has the revised final corpus undergone an independent clinician audit distinct from the original 60-item audit? Please clarify the sampling procedure and residual factual, unsafe-recommendation, and label/rationale-consistency findings. If such evidence is not available, a limited stratified audit of the final synthetic components would materially affect the assessment of the resource. Followup",
+ "comment": "In our audit before the pipeline revisions, we got one clinician to review 20 random samples per set. In this audit, we asked 2 clinicians to review 20 distinct random samples per set. Items marked “rejected” in the earlier audit correspond to Wrong or Partly wrong in the current scale.\n\n| Set | Earlier corpus: rejected | Final corpus: Wrong or Partly wrong | Final corpus: Wrong |\n| ----- | ----- | ----- | ----- |\n| Synthetic MCQA | 6 / 20 (30%) | 5 / 40 (12.5%) | 3 / 40 (7.5%) |\n| Guidelines QA | 2 / 20 (10%) | 5 / 40 (12.5%) | 3 / 40 (7.5%) |\n| **Both** | **8 / 40 (20%, 95% CI 10–35)** | **10 / 80 (12.5%, 95% CI 7–22)** | **6 / 80 (7.5%, 95% CI 3–15)** |\n\nThe pipeline revisions show a slight but not statistically significant improvement in the quality of the corpus (p \\= 0.29). Even after pipeline revisions, the corpus is still limited by the competency of the teacher model. Even if gpt-oss is a competent medical LLM, an estimated 12.5% of sampled items were still flagged as Wrong or Partly wrong, and 7.5% as Wrong. While out of the scope of this submission, we are interested in exploring judge agreement with clinicians in audits of medical training data, as we believe this might show whether LLMs can self correct and find errors in their output.\n\nAdditionally the clinicians label for unsafe recommendation went down from 7.5% to 3.8%. But the counts are too small to show a trend. \n\n| Reason | Earlier corpus (40 items) | Final corpus (80 items) |\n| ----- | ----- | ----- |\n| Ambiguous or unclear question | 6 (15%) | 1 (1.3%) |\n| Factual error | 3 (7.5%) | 1 (1.3%) |\n| Unsafe recommendation | 3 (7.5%) | 3 (3.8%) |\n| Hallucination / not supported by the source | 3 (7.5%) | 1 (1.3%) |\n| Important point missing | not asked | 1 (1.3%) |\n| Other: answer key disputable | not asked | 2 (2.5%) |\n| No reason given | – | 1 (1.3%) |\n| **Items flagged** | **8 (20%)** | **10 (12.5%)** |"
+ },
+ "createdAt": "2026-11-17T10:04:07.788Z",
+ "modifiedAt": "2026-11-17T10:04:07.788Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=aZ8Yyt72q7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/dlauh3luwm.json added

+++ b/reviews/openreview/fnycas5h4q/notes/dlauh3luwm.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "DlAUh3lUWm",
+ "replyTo": "w6o2OJAt7z",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q2: Are blinded clinician judgments available for a sample of the newly generated model comparisons, especially MeditronFO versus its base and versus MedGemma, including cases with disagreement? Please distinguish evidence from historical unanimous pairs from evidence supporting the current model rankings.",
+ "comment": "A blinded clinician evaluation of the new model comparisons is being conducted with our clinical partners and will be published in a separate study. Meanwhile, we have extended the AutoMOOVE validation beyond unanimous pairs in Appendix I.2, Table 17 in the PDF. On all 1,325 historical pairs with 2+ clinician ratings, including disputed ones, our judge agrees with clinician majority at κ=0.361, compared with κ=0.309 between a clinician and the clinician majority. Agreement holds across the eight model families in the pool.\n\n| **Cohen's κ (agreement %)** | **All pairs (1,325)** | **Unanimous (576)** |\n| --- | --- | --- |\n| Clinician vs. clinician | 0.223 \\[0.188, 0.259\\] (51.4%) | 1 (by construction) |\n| Gemma-4-31B vs. each clinician | 0.281 \\[0.252, 0.311\\] (55.8%) | 0.593 \\[0.531, 0.653\\] (77.0%) |\n| Clinician vs. majority of the other clinicians | 0.309 \\[0.267, 0.350\\] (58.0%) | 1 (by construction) |\n| Gemma-4-31B vs. majority of the other clinicians | 0.361 \\[0.322, 0.400\\] (61.6%) | 0.595 \\[0.532, 0.655\\] (77.1%) |\n\nBy model: (Cohen's κ (agreement %))\n\n| **Model** | **Pairs (all / unanimous)** | **Clinician vs. other clinicians, all pairs** | **Gemma-4-31B vs. other clinicians, all pairs** | **Gemma-4-31B, unanimous pairs** |\n| --- | --- | --- | --- | --- |\n| Meditron3-70B | 785 / 332 | 0.291 (57.5%) | 0.364 (62.5%) | 0.627 (79.8%) |\n| Meditron-DPO | 442 / 201 | 0.338 (60.9%) | 0.449 (68.5%) | 0.671 (82.3%) |\n| GPT-4o | 258 / 136 | 0.374 (62.6%) | 0.424 (66.5%) | 0.657 (80.8%) |\n| Gemini-2.0-Flash | 219 / 101 | 0.327 (58.5%) | 0.385 (62.7%) | 0.596 (78.0%) |\n| MedGemma-27B | 171 / 75 | 0.284 (56.1%) | 0.381 (61.6%) | 0.605 (75.6%) |\n| DeepSeek-V3 | 160 / 74 | 0.343 (59.7%) | 0.434 (65.6%) | 0.593 (76.4%) |\n| Llama-3.3-70B | 144 / 63 | 0.350 (58.5%) | 0.309 (58.2%) | 0.463 (69.9%) |\n| Claude-3.7-Sonnet | 133 / 58 | 0.319 (58.2%) | 0.270 (55.8%) | 0.474 (70.5%) |\n| All | 1,325 / 576 | 0.309 (58.0%) | 0.361 (61.6%) | 0.595 (77.1%) |\n\nThese pairs do not include MeditronFO outputs, so this supports the judge’s reliability but does not replace clinician review of the new comparisons. We now state in Section 7 (Limitations) that AutoMOOVE win rates are judge preferences, not clinician preferences. As complementary evidence, HealthBench grades the new models’ answers against clinician-written rubrics. On OpenAI’s physician-labelled meta-evaluation (added in Appendix H.1 in the PDF), our grader reaches macro F1 0.698 \\[0.692, 0.705\\], against 0.672 for physicians compared with each other."
+ },
+ "createdAt": "2026-11-14T17:27:58.316Z",
+ "modifiedAt": "2026-11-14T17:27:58.316Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=DlAUh3lUWm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/dvw7r89gu3.json added

+++ b/reviews/openreview/fnycas5h4q/notes/dvw7r89gu3.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "dVW7r89GU3",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q3b: and was the final corpus re-audited by clinicians after the pipeline revisions?",
+ "comment": "A clinician re-audit of the final corpus is under way. It covers the Guidelines QA dataset and Synthetic MCQA datasets, which are easier for clinicians to review compared to the long form questions and answers of the Synthetic Vignettes set. Clinicians are reviewing 20 randomly sampled pairs from each set, and rating them on the following axis (Wrong, Partly Wrong, Partly Correct, Correct), and for the Wrong and Partly Wrong pairs, they are then instructed to label them on the following categories (Unsafe recommendation, Factual error, unclear information, or other)."
+ },
+ "createdAt": "2026-11-14T17:25:58.050Z",
+ "modifiedAt": "2026-11-14T17:25:58.050Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=dVW7r89GU3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/dw1nf3mjeu.json added

+++ b/reviews/openreview/fnycas5h4q/notes/dw1nf3mjeu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "dW1Nf3Mjeu",
+ "replyTo": "QzGeq3vMXw",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W2a: The authors should provide a targeted clinician check of the final data. Followup",
+ "comment": "In our audit before the pipeline revisions, we got one clinician to review 20 random samples per set. In this audit, we asked 2 clinicians to review 20 distinct random samples per set. Items marked “rejected” in the earlier audit correspond to Wrong or Partly wrong in the current scale.\n\n| Set | Earlier corpus: rejected | Final corpus: Wrong or Partly wrong | Final corpus: Wrong |\n| ----- | ----- | ----- | ----- |\n| Synthetic MCQA | 6 / 20 (30%) | 5 / 40 (12.5%) | 3 / 40 (7.5%) |\n| Guidelines QA | 2 / 20 (10%) | 5 / 40 (12.5%) | 3 / 40 (7.5%) |\n| **Both** | **8 / 40 (20%, 95% CI 10–35)** | **10 / 80 (12.5%, 95% CI 7–22)** | **6 / 80 (7.5%, 95% CI 3–15)** |\n\nThe pipeline revisions show a slight but not statistically significant improvement in the quality of the corpus (p \\= 0.29). Even after pipeline revisions, the corpus is still limited by the competency of the teacher model. Even if gpt-oss is a competent medical LLM, an estimated 12.5% of sampled items were still flagged as Wrong or Partly wrong, and 7.5% as Wrong. While out of the scope of this submission, we are interested in exploring judge agreement with clinicians in audits of medical training data, as we believe this might show whether LLMs can self correct and find errors in their output.\n\nAdditionally the clinicians label for unsafe recommendation went down from 7.5% to 3.8%. But the counts are too small to show a trend. \n\n| Reason | Earlier corpus (40 items) | Final corpus (80 items) |\n| ----- | ----- | ----- |\n| Ambiguous or unclear question | 6 (15%) | 1 (1.3%) |\n| Factual error | 3 (7.5%) | 1 (1.3%) |\n| Unsafe recommendation | 3 (7.5%) | 3 (3.8%) |\n| Hallucination / not supported by the source | 3 (7.5%) | 1 (1.3%) |\n| Important point missing | not asked | 1 (1.3%) |\n| Other: answer key disputable | not asked | 2 (2.5%) |\n| No reason given | – | 1 (1.3%) |\n| **Items flagged** | **8 (20%)** | **10 (12.5%)** |"
+ },
+ "createdAt": "2026-11-17T10:02:47.247Z",
+ "modifiedAt": "2026-11-17T10:02:47.247Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=dW1Nf3Mjeu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/ecmzpyro9u.json added

+++ b/reviews/openreview/fnycas5h4q/notes/ecmzpyro9u.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ecmZpyRo9U",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for the careful and constructive review, and for recognising the value of our open development pipeline and evaluation analyses. Your comments identify several places where we should clarify the scope of our claims and present the supporting evidence more clearly. This is very helpful. We respond point by point below, and we have already updated the PDF."
+ },
+ "createdAt": "2026-11-14T17:21:37.007Z",
+ "modifiedAt": "2026-11-14T17:21:37.007Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=ecmZpyRo9U",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/ewbgutd8l8.json added

+++ b/reviews/openreview/fnycas5h4q/notes/ewbgutd8l8.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "EwbgutD8l8",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q4a: What are the answer-parsing failure rates for base and fine-tuned models on the medical MCQA benchmarks, and are the conclusions robust to alternative answer extraction?",
+ "comment": "Finetuning reduces the answer-parsing failure rates for most base models. EuroLLM is the exception, its failure increases on PubMedQA. With lenient parsing, the gains hold for both Apertus base finetunes. The benchmark gains from applying our training mixture persist when using lenient parsing to judge the answers. Specifically for Apertus-70B, we see an increase of 5.3% according to strict answer parsing and 4.9% according to lenient answer parsing. The confidence intervals are overlapping. We added Table 11 in Appendix F in the PDF.\n\n| **Unparsed (%)** | **MedQA** | **MedMCQA** | **PubMedQA** | **MedXpertQA** | **Mean** |\n| --- | --- | --- | --- | --- | --- |\n| Apertus-8B-Instruct → MeditronFO | 0.8 → 0.0 | 0.6 → 0.1 | 0.1 → 0.1 | 2.4 → 0.3 | 1.0 → 0.1 |\n| Apertus-70B-Instruct → MeditronFO | 3.4 → 0.1 | 3.2 → 0.0 | 0.0 → 0.0 | 4.2 → 0.4 | 2.7 → 0.1 |\n| OLMo-2-32B-SFT → MeditronFO | 6.0 → 0.4 | 1.1 → 1.8 | 9.8 → 0.0 | 8.5 → 0.2 | 6.4 → 0.6 |\n| EuroLLM-22B-Instruct → MeditronFO | 0.2 → 0.1 | 0.6 → 0.3 | 0.0 → 0.0 | 0.3 → 0.2 | 0.3 → 0.1 |\n| EuroLLM-9B-Instruct → MeditronFO | 0.7 → 3.4 | 1.4 → 2.0 | 0.0 → 7.8 | 7.1 → 3.6 | 2.3 → 4.2 |\n| Gemma-3-27B-IT → MeditronFO | 0.0 → 0.2 | 0.1 → 0.1 | 0.0 → 0.0 | 0.1 → 0.1 | 0.1 → 0.1 |\n| MedGemma-27B | 0.6 | 0.8 | 0.0 | 1.4 | 0.7 |\n\n| **MCQA mean, finetune − base (points)** | **Strict (paper)** | **Lenient** |\n| --- | --- | --- |\n| Apertus-8B | +3.3 \\[+2.1, +4.6\\] | +3.2 \\[+2.0, +4.4\\] |\n| Apertus-70B | +5.3 \\[+4.2, +6.4\\] | +4.9 \\[+3.8, +6.0\\] |\n| OLMo-2-32B | +4.9 \\[+3.9, +6.0\\] | +1.7 \\[+0.7, +2.6\\] |\n| EuroLLM-22B | +0.2 \\[−1.0, +1.2\\] | +0.1 \\[−1.0, +1.1\\] |\n| EuroLLM-9B | −0.2 \\[−1.4, +1.1\\] | +1.7 \\[+0.5, +2.8\\] |\n| Gemma-3-27B | +0.6 \\[−0.2, +1.4\\] | +0.6 \\[−0.2, +1.4\\] |"
+ },
+ "createdAt": "2026-11-14T17:26:15.896Z",
+ "modifiedAt": "2026-11-14T17:26:15.896Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=EwbgutD8l8",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/fvi9xov8ef.json added

+++ b/reviews/openreview/fnycas5h4q/notes/fvi9xov8ef.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "fVi9XOV8ef",
+ "replyTo": "dVW7r89GU3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q3b: and was the final corpus re-audited by clinicians after the pipeline revisions? Followup",
+ "comment": "In our audit before the pipeline revisions, we got one clinician to review 20 random samples per set. In this audit, we asked 2 clinicians to review 20 distinct random samples per set. Items marked “rejected” in the earlier audit correspond to Wrong or Partly wrong in the current scale.\n\n| Set | Earlier corpus: rejected | Final corpus: Wrong or Partly wrong | Final corpus: Wrong |\n| ----- | ----- | ----- | ----- |\n| Synthetic MCQA | 6 / 20 (30%) | 5 / 40 (12.5%) | 3 / 40 (7.5%) |\n| Guidelines QA | 2 / 20 (10%) | 5 / 40 (12.5%) | 3 / 40 (7.5%) |\n| **Both** | **8 / 40 (20%, 95% CI 10–35)** | **10 / 80 (12.5%, 95% CI 7–22)** | **6 / 80 (7.5%, 95% CI 3–15)** |\n\nThe pipeline revisions show a slight but not statistically significant improvement in the quality of the corpus (p \\= 0.29). Even after pipeline revisions, the corpus is still limited by the competency of the teacher model. Even if gpt-oss is a competent medical LLM, an estimated 12.5% of sampled items were still flagged as Wrong or Partly wrong, and 7.5% as Wrong. While out of the scope of this submission, we are interested in exploring judge agreement with clinicians in audits of medical training data, as we believe this might show whether LLMs can self correct and find errors in their output.\n\nAdditionally the clinicians label for unsafe recommendation went down from 7.5% to 3.8%. But the counts are too small to show a trend. \n\n| Reason | Earlier corpus (40 items) | Final corpus (80 items) |\n| ----- | ----- | ----- |\n| Ambiguous or unclear question | 6 (15%) | 1 (1.3%) |\n| Factual error | 3 (7.5%) | 1 (1.3%) |\n| Unsafe recommendation | 3 (7.5%) | 3 (3.8%) |\n| Hallucination / not supported by the source | 3 (7.5%) | 1 (1.3%) |\n| Important point missing | not asked | 1 (1.3%) |\n| Other: answer key disputable | not asked | 2 (2.5%) |\n| No reason given | – | 1 (1.3%) |\n| **Items flagged** | **8 (20%)** | **10 (12.5%)** |"
+ },
+ "createdAt": "2026-11-17T10:03:38.173Z",
+ "modifiedAt": "2026-11-17T10:03:38.173Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=fVi9XOV8ef",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/g9z0m8mtdb.json added

+++ b/reviews/openreview/fnycas5h4q/notes/g9z0m8mtdb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "g9z0M8MtDB",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q3a: During answer distillation for Guidelines QA, does the teacher receive the source guideline? How is correctness checked beyond agreement with the generated answer label?",
+ "comment": "No. The teacher does not receive the source guideline during the answer generation, the guideline is only shown to the model that writes the question. Beyond agreement with the answer label, which the question writer generates from the source guideline, there is no automatic correctness check: the closed book teacher must reach that label within 8 tries or the item is dropped."
+ },
+ "createdAt": "2026-11-14T17:25:42.481Z",
+ "modifiedAt": "2026-11-14T17:25:42.481Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=g9z0M8MtDB",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/imrpahvikx.json added

+++ b/reviews/openreview/fnycas5h4q/notes/imrpahvikx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "imRPAhVIKX",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q2: Several fine-tuned models show substantial instruction-following losses, and the teacher comparison suggests that these losses can be partly mitigated. How do the authors weigh these trade-offs when recommending models and teacher variants for downstream research, particularly when the medical gains are small?",
+ "comment": "We agree with you that this is a trade-off that should be discussed, and we now do so in Section 5.2. IFeval loose mode shows that part of the performance drop reflects overfitting on a particular answer format. \n\nWe ablated the teacher choice in Section 5.2 “Second teacher ablation” and Appendix K. The main alternative was Qwen3.8-27B, compared with gpt-oss-120b as a teacher, Qwen3.8 gives much smaller instruction-following losses (IFEval 49.5 vs 38.6 for Apertus-8b), and a non statistically significant difference on HealthBench scores. On medical MCQA under strict parsing it scores 2 points lower for Apertus-70b. \n\n| **model** | **teacher** | **MCQA** | **IFEval** | **HB full** | **AutoMOOVE** |\n| --- | --- | --- | --- | --- | --- |\n| Apertus-8B | - | 46.5 | 70.1 | 26.0 | - |\n| Apertus-8B | gpt-oss-120b | 49.8 | 38.6 | 42.1 | 75.3 |\n| Apertus-8B | Qwen3.8-27B | 49.8 | 49.5 | 42.5 | - |\n| Apertus-70B | - | 50.6 | 63.4 | 39.4 | - |\n| Apertus-70B | gpt-oss-120b | 55.9 | 42.9 | 49.3 | 89.1 |\n| Apertus-70B | Qwen3.8-27B | 54.0 | 49.7 | 50.6 | - |\n\nPart of this gap comes from answer formatting, models trained on Qwen3.8 answers leave 5-8% of MCQA answers unparsed compared with 0.1% for gpt-oss-120b. Under lenient answer extraction, the two teachers are level within confidence intervals. \n\n| **MCQA mean, Qwen3.8 teacher − gpt-oss teacher** | **Unparsed, Qwen3.8 / gpt-oss** | **Strict (paper)** | **Lenient** |\n| --- | --- | --- | --- |\n| Apertus-8B | 5.2% / 0.1% | +0.0 \\[−1.1, +1.1\\] | +0.7 \\[−0.4, +1.8\\] |\n| Apertus-70B | 8.4% / 0.1% | −1.9 \\[−3.0, −0.7\\] | +0.5 \\[−0.6, +1.6\\] |\n\nIn our submission we report strict parsing because it keeps results reproducible and comparable across papers, and we use lenient parsing as a robustness check. Under this protocol gpt-oss-120b is the strongest teacher for medical MCQA, so our main MeditronFO corpus is built on it. For downstream research, we recommend the gpt-oss-120b variant when standardized medical benchmark performance is the priority, and the Qwen3.8 variant when instruction following matters. We added this trade-off discussion in Section 5.2 and we will release both variants as Apache 2.0 artifacts for the community."
+ },
+ "createdAt": "2026-11-14T17:16:23.030Z",
+ "modifiedAt": "2026-11-14T17:16:23.030Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=imRPAhVIKX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/isqtbey8qn.json added

+++ b/reviews/openreview/fnycas5h4q/notes/isqtbey8qn.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "IsQTbEy8Qn",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "General response",
+ "comment": "Thank you for your constructive reviews. We are glad that the reviewers found the paper addresses \"a useful practical problem of making medical LLM development transparent and reproducible\" (ori5), is \"a useful resource-oriented development contribution\" (SyJp) that \"could provide a useful baseline for fully open medical LLM development\" (xFAx), and offers a \"broad evaluation with substantial attention to failure modes\" (SyJp), with \"substantial\" experimental effort (ori5).\n\nWe summarize how we addressed the reviewers' concerns below. We have already updated the PDF. \n\n1) **AutoMOOVE validation beyond unanimous pairs (ori5, xFAx, SyJp):** \n We have extended the AutoMOOVE validation beyond unanimous pairs (Appendix I.2, table 17). On all 1,325 historical pairs with 2+ clinician ratings, including disputed ones, our judge agrees with the clinician majority at κ=0.361, compared with κ=0.309 for a clinician with the clinician majority. \n2) **The value added by the synthetic expansion (ori5, xFAx):** \n Our contribution is the open, auditable data and training resource and its evaluation. The new Curated QA-only ablation (Appendix J) quantifies the combined contribution of the synthetic sources: the gains are largest on IFeval and AutoMOOVE, and small on MCQA and HealthBench. Replication results show that the curatedQA ablation exceeds the run to run noise. \n3) **The recipe's effectiveness across model families and answer length (xFAx, SyJp):** \n We agree that our recipe is limited in its effectiveness across model families, we find that it is more effective on a fully-open base. We believe the medical domain gap between fully-open and open weight models can be partly bridged thanks to our recipe. After length adjustment, the HealthBench gain remains significant for Apertus-70B, Apertus-8B, OLMo-2-32B and EuroLLM-9B, but becomes a loss for EuroLLM-22B and Gemma-3-27B. \n4) **A new targeted clinician check of the final data (ori5, xFAx, SyJp):** \n In this new audit, we asked 2 clinicians to review 20 distinct random samples per set. It covers the Guidelines QA and Synthetic MCQA datasets. The corpus is still limited by the competency of the teacher model. An estimated 12.5% of sampled items were still flagged as Wrong or Partly wrong, and 7.5% as Wrong. Additionally the clinicians label for unsafe recommendation went down from 7.5% to 3.8%. But the counts are too small to show a trend. \n5) **Answer-parsing failure rates and teacher variants (ori5, xFAx):** \n The benchmark gains from applying our training mixture persist when using lenient parsing to judge the answers. We added Table 11 in Appendix F. Compared with gpt-oss-120b as a teacher, Qwen3.8 gives much smaller instruction-following losses (IFEval 49.5 vs 38.6 for Apertus-8b), and a non statistically significant difference on HealthBench scores. Under lenient answer extraction, the two teachers are level within confidence intervals. We will release both variants as Apache 2.0 artifacts. \n6) **The scope of the \"fully open\" claim (xFAx):** \n By “fully open” we mean that others can inspect the complete training corpus, reproduce our training procedure, and reuse our work. We therefore publicly release the Meditron Fully Open Corpus under Apache 2.0, together with the preprocessing and training code. The corpus includes the teacher-generated answers used for training. \n7) **In progress:** \n A blinded clinician evaluation of the new model comparisons is being conducted and will be published in a separate study. We are in the process of open sourcing our MOOVE seed vignettes and clinician preference labels as Apache 2.0.\n\nTo our knowledge, MeditronFO is the first fully open pipeline for medical finetuning, and it achieves the best results among fully open models on the medical benchmarks we evaluate. We release the data, code and model weights as public artifacts, and we hope this recipe will serve as a stepping stone for fully open research on medical expert models."
+ },
+ "createdAt": "2026-11-17T12:19:33.682Z",
+ "modifiedAt": "2026-11-17T12:19:33.682Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=IsQTbEy8Qn",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/mqlmag4uqc.json added

+++ b/reviews/openreview/fnycas5h4q/notes/mqlmag4uqc.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "mQLMaG4uQC",
+ "replyTo": "w6o2OJAt7z",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for the careful and constructive review, and for recognising the value of the resource. We answer your questions below."
+ },
+ "createdAt": "2026-11-14T17:27:16.202Z",
+ "modifiedAt": "2026-11-14T17:27:16.202Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=mQLMaG4uQC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/mv7lnhnjcv.json added

+++ b/reviews/openreview/fnycas5h4q/notes/mv7lnhnjcv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "mV7LNhnjCV",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q2b: and is clinician evaluation available for the model comparisons reported in this paper?",
+ "comment": "A blinded clinician evaluation of the new model comparisons is being conducted with our clinical partners and will be published in a separate study. In the limitations section we have added that AutoMOOVE is not a replacement for clinician evaluations, and that AutoMOOVE win rates are judge preferences, not clinicians preferences. \n\nAs complementary evidence we report HealthBench, where models answer realistic health queries and are graded against clinician-written rubrics.\n\nTo check our HealthBench grader, we ran it on the meta-evaluation provided by OpenAI, which validates a  grader against held-out physician label (added in Appendix H.1 in the PDF):\n\n| **Grader (vs. physician labels)** | **Macro F1 \\[95% CI\\]** |\n| --- | --- |\n| Physicians  | 0.672 |\n| **Gemma-4-31B (our HealthBench grader)** | **0.698** \\[0.692, 0.705\\] |\n| Qwen3.8-27B (our second grader) | 0.681 \\[0.675, 0.687\\] |\n\nOur grader agrees with physicians at least as well as physicians agree with each other."
+ },
+ "createdAt": "2026-11-14T17:25:17.504Z",
+ "modifiedAt": "2026-11-14T17:25:17.504Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=mV7LNhnjCV",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/my3f9ubqhe.json added

+++ b/reviews/openreview/fnycas5h4q/notes/my3f9ubqhe.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "my3F9UbqhE",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W1: The methodological advance is modest and the value added by the synthetic expansion is only partly established.",
+ "comment": "We agree that the individual techniques are established. Our contribution is the open, auditable data and training resource and its evaluation. The new Curated QA-only ablation (Q1) quantifies the combined contribution of the synthetic sources: the gains are largest on IFeval and AutoMOOVE, and small on MCQA and HealthBench. We hope this recipe will serve as a stepping stone for fully open research on medical expert models. To our knowledge, it is the first fully open pipeline for medical finetuning, and it achieves the best results among fully open models on the medical benchmarks we evaluate."
+ },
+ "createdAt": "2026-11-14T17:18:42.829Z",
+ "modifiedAt": "2026-11-14T17:18:42.829Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=my3F9UbqhE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/mysqr2wp94.json added

+++ b/reviews/openreview/fnycas5h4q/notes/mysqr2wp94.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "MYsQR2wP94",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q1: Did the authors evaluate distillation on Curated QA alone using the same teacher and a comparable training-token budget? This would help quantify the combined contribution of the synthetic expansion beyond the existing leave-one-component-out results.",
+ "comment": "Yes. The results of Curated QA alone compared to the full corpus are shown below. As the corpus components differ in size, we did not match the training-token budget. Matching would require subsampling or repeating individual samples. For our training mixture we train on 1 epoch of the full corpus, with equal repetition for each individual sample.\n\nCurated QA alone improves the baseline model, but the full corpus mixture is overall stronger on benchmarks, and importantly recovers more of the IFEval loss. The differences are largest on IFEval and AutoMOOVE, and small on MCQA and HealthBench.\n\n| **model** | **training data** | **MCQA** | **IFEval** | **HB full** | **AutoMOOVE** **(win rate against base)** |\n| --- | --- | --- | --- | --- | --- |\n| 8B | - | 46.5 | 70.1 | 26 | - |\n| 8B | full corpus | 49.8 | 38.6 | 42.1 | 75.3 |\n| 8B | Curated QA only | 49.0 | 33.3 | 41.5 | 65.7 |\n| 70B | - | 50.6 | 63.4 | 39.4 | - |\n| 70B | full corpus | 55.9 | 42.9 | 49.3 | 89.1 |\n| 70B | Curated QA only | 54.1 | 30.1 | 49.1 | 84.6 |\n\nThank you for this suggestion, we have added the CuratedQA ablation results in Appendix J in the submission."
+ },
+ "createdAt": "2026-11-14T17:15:44.159Z",
+ "modifiedAt": "2026-11-14T17:15:44.159Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=MYsQR2wP94",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/nymzkatwdp.json added

+++ b/reviews/openreview/fnycas5h4q/notes/nymzkatwdp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "nyMZkaTWDP",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q4: The method overview and some dense tables are difficult to read at normal viewing size. The authors should enlarge the figure labels and the smallest table text, and improve typographic consistency where feasible.",
+ "comment": "We apologize for this oversight on our part and we have updated the pdf. We enlarged every figure and the table text, and made the typography more consistent. Please tell us if this is more readable now."
+ },
+ "createdAt": "2026-11-14T17:18:26.432Z",
+ "modifiedAt": "2026-11-14T17:18:26.432Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=nyMZkaTWDP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/o53rtcooqi.json added

+++ b/reviews/openreview/fnycas5h4q/notes/o53rtcooqi.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "o53RtCoOqI",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W1: The Gemma-based MeditronFO model shows no statistically significant improvement in average MCQA performance, loses ground after HealthBench length adjustment, and exhibits greater general-purpose degradation than MedGemma relative to the same base. These results limit the evidence for the recipe’s effectiveness across model families.",
+ "comment": "We agree that our recipe is limited in its effectiveness across model families, we find that it is more effective on a fully-open base. We believe the medical domain gap between fully-open and open weight models can be partly bridged thanks to our recipe. We have clarified this finding in the PDF."
+ },
+ "createdAt": "2026-11-14T17:22:03.211Z",
+ "modifiedAt": "2026-11-14T17:22:03.211Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=o53RtCoOqI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/pydkwulub1.json added

+++ b/reviews/openreview/fnycas5h4q/notes/pydkwulub1.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "PyDKWuLUb1",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer ori5",
+ "content": {
+ "paper_summary": "This paper presents an open and auditable pipeline for adapting language models to medicine. It combines existing medical question-answering data with synthetic questions and teacher-generated answers, and evaluates the resulting models through knowledge-based and open-ended assessments. Its main contribution is a reusable data and training resource, together with an automated evaluation protocol validated against historical clinician preferences.",
+ "presentation": 3,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "1. The paper addresses a useful practical problem of making medical LLM development transparent and reproducible. The documented data sources, generation prompts, filtering procedures, and training configurations provide a concrete foundation for others to reproduce and extend this work.\n2. The experimental effort is substantial. The study covers multiple model families, component ablations at two model sizes, a second teacher, repeated training runs, and checks of judge, answer-order, and length sensitivity. This provides a careful assessment of the recipe and its limitations.",
+ "critical_weaknesses": "1. The methodological advance is modest and the value added by the synthetic expansion is only partly established. The pipeline combines existing synthetic generation, rejection sampling, and SFT methods. Table 21 shows specific benefits from Synthetic Curated QA and synthetic vignettes, but these vary across model sizes and metrics, while Curated QA provides the most consistent gains. The experiments establish the usefulness of the overall recipe more clearly than the additional contribution of the new synthetic sources.\n2. Direct clinician validation of the final data and model comparisons remains limited. The item-level clinician audit covers 60 examples from an earlier corpus, while the final corpus is screened by LLMs. AutoMOOVE is validated on 576 historical response pairs selected for unanimous clinician agreement. These checks provide useful evidence, but leave uncertainty about the final corpus’s error rate and clinician agreement with the new model comparisons. The authors should provide a targeted clinician check of the final data.",
+ "questions_for_authors": "1. Did the authors evaluate distillation on Curated QA alone using the same teacher and a comparable training-token budget? This would help quantify the combined contribution of the synthetic expansion beyond the existing leave-one-component-out results.\n2. Several fine-tuned models show substantial instruction-following losses, and the teacher comparison suggests that these losses can be partly mitigated. How do the authors weigh these trade-offs when recommending models and teacher variants for downstream research, particularly when the medical gains are small?\n3. Did the authors exclude held-out benchmark items from the Curated QA exemplar pool before synthetic question generation, in addition to decontaminating the final corpus?\n4. The method overview and some dense tables are difficult to read at normal viewing size. The authors should enlarge the figure labels and the smallest table text, and improve typographic consistency where feasible.",
+ "flag_for_ethics_review": "No",
+ "rating": 2,
+ "confidence": 3
+ },
+ "createdAt": "2026-10-22T06:10:04.602Z",
+ "modifiedAt": "2026-11-06T12:41:01.244Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=PyDKWuLUb1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/qzgeq3vmxw.json added

+++ b/reviews/openreview/fnycas5h4q/notes/qzgeq3vmxw.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "QzGeq3vMXw",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "W2a: The authors should provide a targeted clinician check of the final data.",
+ "comment": "We agree with you. A clinician re-audit of the final corpus is under way. It covers the Guidelines QA and Synthetic MCQA datasets, which are easier for clinicians to review than the long-form questions and answers of the Synthetic Vignettes set. Clinicians are reviewing 20 randomly sampled pairs from each set and rating them as Wrong, Partly Wrong, Partly Correct or Correct. Wrong and Partly Wrong pairs are further labelled as Unsafe recommendation, Factual error, Unclear information or Other."
+ },
+ "createdAt": "2026-11-14T17:19:09.138Z",
+ "modifiedAt": "2026-11-14T17:19:09.138Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=QzGeq3vMXw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/vkxwhwgq5a.json added

+++ b/reviews/openreview/fnycas5h4q/notes/vkxwhwgq5a.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "vKxWHwgQ5A",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q1a: Which guideline sources were used, and which source materials, including guideline texts, MOOVE seed vignettes, and clinician preference labels, will be released under what terms?",
+ "comment": "The guideline sources that we have used are publicly available on the web. We cannot re-release the original texts under Apache 2.0, so we cite each source instead. The synthetic GuidelinesQA dataset derived from them is released under Apache 2.0, together with the list of source URLs and the scraping code, so the seed set can be reconstructed.\n\nHere is the list of the guidelines used as context data for the synthetic GuidelinesQA dataset (added as Table 1 in Appendix A.1):\n\n| **Tag** | **Source** | **Country** | **Guidelines** |\n| --- | --- | --- | --- |\n| drugs | [Drugs.com](https://www.drugs.com/) | International | 7,216 |\n| nice | [National Institute for Health and Care Excellence (NICE)](https://www.nice.org.uk/guidance) | UK | 1,656 |\n| pubmed | [PubMed](https://pubmed.ncbi.nlm.nih.gov) (guideline articles) | Mix | 1,627 |\n| mayo | [Mayo Clinic](https://www.mayoclinic.org/) | USA | 1,184 |\n| cdc | [Centers for Disease Control and Prevention (CDC)](https://www.cdc.gov/) | USA | 621 |\n| cma | [Canadian Medical Association CPG Infobase](https://joulecma.ca/cpg/browse-by/category/producers) | Canada | 432 |\n| rch | [Royal Children's Hospital Melbourne](https://www.rch.org.au/clinicalguide/about_rch_cpgs/welcome_to_the_clinical_practice_guidelines/) | Australia | 292 |\n| who | [World Health Organization (WHO)](https://www.who.int/publications/who-guidelines) | International | 223 |\n| magic | [MAGIC (Making GRADE The Irresistible Choice)](https://magicevidence.org/) | Mix | 219 |\n| spor | [SPOR Evidence Alliance CPG database](https://sporevidencealliance.ca/key-activities/cpg-asset-map/cpg-database/) | Canada | 217 |\n| cps | [Canadian Paediatric Society (CPS)](https://cps.ca) | Canada | 193 |\n| idsa | [Infectious Diseases Society of America (IDSA)](https://www.idsociety.org/) | USA | 94 |\n| cco | [Cancer Care Ontario (CCO)](https://www.cancercareontario.ca/en/guidelines-advice) | Canada | 87 |\n| aafp | [American Academy of Family Physicians (AAFP)](https://www.aafp.org) | USA | 58 |\n| icrc | [International Committee of the Red Cross (ICRC)](https://www.icrc.org/) | International | 49 |\n| gc | [Guideline Central](https://www.guidelinecentral.com/) | Mix | 24 |\n| **Total** | | | **14,192** |\n\nWe are in the process of open sourcing our MOOVE seed vignettes and clinician preference labels as Apache 2.0. This takes time because we have to coordinate with the different partners, and we target camera-ready for the release. The released corpus already includes the Synthetic Vignettes generated from these seeds, so training can be reproduced without them."
+ },
+ "createdAt": "2026-11-14T17:23:00.987Z",
+ "modifiedAt": "2026-11-14T17:23:00.987Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=vKxWHwgQ5A",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/w6o2ojat7z.json added

+++ b/reviews/openreview/fnycas5h4q/notes/w6o2ojat7z.json
@@ -0,0 +1,24 @@
+{
+ "schema": "review/1",
+ "id": "w6o2OJAt7z",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer SyJp",
+ "content": {
+ "paper_summary": "The paper presents MeditronFO, a clinical-LLM development pipeline combining public medical QA, synthetic QA, guideline-derived questions, and synthetic clinical vignettes. The final corpus contains 533,888 examples, with answer distillation, label-based rejection sampling where applicable, decontamination, and audit procedures. The pipeline is applied to five fully-open bases and a Gemma-3-27B open-weight control. Apertus-70B improves from 48.35% to 54.56% on the reported five-benchmark average. The paper also introduces AutoMOOVE: judges are validated against 576 historical answer pairs with unanimous clinician preferences, and new models are compared on the corresponding 516 vignettes. Analyses examine corpus components, teacher choice, judge robustness, response length, and general-capability degradation.",
+ "presentation": 3,
+ "informativeness": 2,
+ "soundness": 2,
+ "critical_strengths": "**S1. A useful resource-oriented development contribution.**\n\nThe manuscript specifies a reproducible sequence from source selection and clinician-informed generation prompts through distillation, decontamination, and medical finetuning. Applying the corpus across several base-model families, while separating fully-open bases from an open-weight control, makes the work more useful than a single-checkpoint release. The described pipeline and associated artifacts could support auditing and controlled follow-up research, even without a new optimization algorithm.\n\n**S2. Broad evaluation with substantial attention to failure modes.**\n\nThe study includes within-base comparisons, multiple-choice and open-ended tasks, multiple judges, order/tie sensitivity, length analyses, component ablations, and a second-teacher comparison. It reports general-capability losses and heterogeneous outcomes across bases rather than presenting adaptation as uniformly beneficial. The paired gains for Apertus and OLMo provide evidence that the training pipeline has practical value within the evaluated settings.",
+ "critical_weaknesses": "**W1. Independent validation of the final training corpus remains limited.**\n\nSection 2.3 reports a clinician audit of 60 items from an earlier corpus, followed by pipeline revisions; the final corpus is assessed primarily through LLM screening. On the small earlier audit set, both judges detect only 3 of 6 clinician-identified factual errors and 1 of 4 hallucinations (Appendix B, Table 1), so their final-corpus flags should not be treated as a reliable estimate of residual error. Moreover, pass@8 checks generator-provided labels for synthetic multiple-choice items, while open-ended items have no equivalent label check. Openness and traceability are valuable, but they do not by themselves characterize the factual and safety profile of the released clinical training resource. A modest independent audit of the final version would strengthen this central contribution.\n\n**W2. AutoMOOVE validates a narrower notion of clinical preference than the model comparison requires.**\n\nThe 576 validation pairs were selected for unanimous clinician agreement, and the resulting three-judge agreement is kappa = 0.564 with ties (Section 3.3; Table 13). This is useful validation, but does not establish reliability on disagreement-prone cases or on newly generated MeditronFO/baseline answer pairs. The paper includes meaningful multi-judge and length checks, yet some model comparisons remain sensitive: Gemma-MeditronFO's win rate against MedGemma is 52.8% [49.0, 56.6] under Qwen3.8, and its HealthBench advantage changes sign after the reported length adjustment. These results do not invalidate the within-base gains, but limit the strength of the clinician-preference evidence supporting the new evaluation resource.",
+ "questions_for_authors": "**Q1**\nHas the revised final corpus undergone an independent clinician audit distinct from the original 60-item audit? Please clarify the sampling procedure and residual factual, unsafe-recommendation, and label/rationale-consistency findings. If such evidence is not available, a limited stratified audit of the final synthetic components would materially affect the assessment of the resource.\n\n**Q2**\nAre blinded clinician judgments available for a sample of the newly generated model comparisons, especially MeditronFO versus its base and versus MedGemma, including cases with disagreement? Please distinguish evidence from historical unanimous pairs from evidence supporting the current model rankings. A small targeted comparison would be more informative here than adding another unvalidated judge.",
+ "flag_for_ethics_review": "No",
+ "rating": 2,
+ "confidence": 2
+ },
+ "createdAt": "2026-10-20T19:49:49.805Z",
+ "modifiedAt": "2026-11-06T12:41:03.554Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=w6o2OJAt7z",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/xxvo5xcxqj.json added

+++ b/reviews/openreview/fnycas5h4q/notes/xxvo5xcxqj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XXvO5XcXQj",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q4b: Were any hyperparameters or checkpoints selected using medical benchmark performance, and if so, which data splits were used?",
+ "comment": "Hyperparameters were not tuned on medical benchmarks: we use the recommended hyperparameters of each base model, taken from their documentation. Models were trained for one epoch. For gemma-3-27b and EuroLLM, medical benchmark results after one epoch were weak on the test split, so we trained them for a second epoch. Even with the second epoch, Gemma-3-27B and EuroLLM show no significant gain on the test split, so this does not modify our main submission claim. We have added a phrase for this in Appendix D.3."
+ },
+ "createdAt": "2026-11-14T17:26:28.704Z",
+ "modifiedAt": "2026-11-14T17:26:28.704Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=XXvO5XcXQj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/y1t0yryoix.json added

+++ b/reviews/openreview/fnycas5h4q/notes/y1t0yryoix.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "y1T0YRYOIX",
+ "replyTo": "PyDKWuLUb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for the careful and constructive review, and for recognising the value of a transparent and reproducible pipeline for medical model development. Below, we respond to your comments and questions point by point."
+ },
+ "createdAt": "2026-11-14T17:15:07.448Z",
+ "modifiedAt": "2026-11-14T17:15:07.448Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=y1T0YRYOIX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/notes/zca2suhb5d.json added

+++ b/reviews/openreview/fnycas5h4q/notes/zca2suhb5d.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "zCa2suhB5d",
+ "replyTo": "59Ft8RFeGX",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Q1b: Please also clarify the scope of the “fully open” claim given the pipeline’s reliance on an open-weight teacher.",
+ "comment": "By “fully open” we mean that others can inspect the complete training corpus, reproduce our training procedure, and reuse our work. We therefore publicly release the Meditron Fully Open Corpus under Apache 2.0, together with the preprocessing and training code. The corpus includes the teacher-generated answers used for training. The teacher, gpt-oss-120b, is available under Apache 2.0, you are right that it is open-weight rather than fully open, but this does not prevent every training sample we train on to be inspected."
+ },
+ "createdAt": "2026-11-14T17:24:21.683Z",
+ "modifiedAt": "2026-11-14T17:24:21.683Z",
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q&noteId=zCa2suhB5d",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fnycas5h4q/submission.json added

+++ b/reviews/openreview/fnycas5h4q/submission.json
@@ -0,0 +1,21 @@
+{
+ "schema": "submission/1",
+ "id": "fnyCAs5h4Q",
+ "venue": {
+ "id": "ICLR.cc/2027/Conference",
+ "name": "ICLR 2027",
+ "url": "https://openreview.net/group?id=ICLR.cc%2F2027%2FConference"
+ },
+ "number": 61005,
+ "keywords": [
+ "Medical LLMs",
+ "Open Source datasets",
+ "Clinical evaluation",
+ "LLM-as-a-judge",
+ "Synthetic data generation",
+ "Supervised fine-tuning",
+ "Clinical decision support"
+ ],
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q",
+ "license": "CC-BY-4.0"
+}

versions/v_7gb5sgb4.json added

+++ b/versions/v_7gb5sgb4.json
@@ -0,0 +1,21 @@
+{
+ "date": "2026-09-19",
+ "kind": "submitted",
+ "label": "ICLR 2027",
+ "submissions": [
+ {
+ "venue": "ICLR 2027",
+ "status": "under_review",
+ "number": 61005,
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q",
+ "reviews": "openreview/fnycas5h4q",
+ "evidence": [
+ "https://openreview.net/forum?id=fnyCAs5h4Q"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=fnyCAs5h4Q",
+ "evidence": [
+ "https://openreview.net/forum?id=fnyCAs5h4Q"
+ ]
+}