When Proxy Calibration Controls the Wrong Risk: Accepted-Set Target Mismatch in Selective LLMs
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:31 UTC · e9cae7edf554 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,19 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "HgJUKKID0K"- }- ],- "title": "When Proxy Calibration Controls the Wrong Risk: Accepted-Set Target Mismatch in Selective LLMs",- "authors": [],- "abstract": "Selective LLM systems often use inexpensive proxy or judge labels for calibration, but a statistically valid certificate only controls the risk defined by those labels. Does proxy-valid selective calibration control the target risk that deployment actually cares about? We derive an accepted-set identity decomposing the proxy--target risk gap into signed disagreement contributions; global judge agreement alone does not establish transfer. At α = 0.20, the held-out main evaluation shows proxy-label calibration selecting λ = 0.2 with coverage 1.000 and held-out target risk 0.250, whereas target-label calibration selects λ = 1.0 with coverage 0.591 and target risk 0.113. A threshold-wise full-frame diagnostic shows that accepted false-positive contributions outweigh false-negative contributions, producing the proxy–target risk gap. In a 400-row blinded validation sample, human judgments agree with the reference-aware operational target on 96.75%, versus 74.50% with the reference-free proxy. The low-threshold failure reproduces under lenient rubrics across DeepSeek, Qwen, and MiniMax, whereas stricter rubrics can select more conservative thresholds or, in one case, return no solution. Increasing target-label audit budgets improves direct feasibility, whereas proxy-assisted corrections can remain conservative. Selective-risk validity is target-relative: deployment claims require measurement validation and target-specific evidence.",- "year": 2027,- "venue": "ICLR 2027 (under review)",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "344acfd6-ea05-41c3-b805-f2f6ebb5a322"}
paper.json added
+++ b/paper.json@@ -0,0 +1,9 @@+{+ "title": "When Proxy Calibration Controls the Wrong Risk: Accepted-Set Target Mismatch in Selective LLMs",+ "authors": [],+ "abstract": "Selective LLM systems often use inexpensive proxy or judge labels for calibration, but a statistically valid certificate only controls the risk defined by those labels. Does proxy-valid selective calibration control the target risk that deployment actually cares about? We derive an accepted-set identity decomposing the proxy--target risk gap into signed disagreement contributions; global judge agreement alone does not establish transfer. At α = 0.20, the held-out main evaluation shows proxy-label calibration selecting λ = 0.2 with coverage 1.000 and held-out target risk 0.250, whereas target-label calibration selects λ = 1.0 with coverage 0.591 and target risk 0.113. A threshold-wise full-frame diagnostic shows that accepted false-positive contributions outweigh false-negative contributions, producing the proxy–target risk gap. In a 400-row blinded validation sample, human judgments agree with the reference-aware operational target on 96.75%, versus 74.50% with the reference-free proxy. The low-threshold failure reproduces under lenient rubrics across DeepSeek, Qwen, and MiniMax, whereas stricter rubrics can select more conservative thresholds or, in one case, return no solution. Increasing target-label audit budgets improves direct feasibility, whereas proxy-assisted corrections can remain conservative. Selective-risk validity is target-relative: deployment claims require measurement validation and target-specific evidence.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}