potentialpaper

When Proxy Calibration Controls the Wrong Risk: Accepted-Set Target Mismatch in Selective LLMs

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:31 UTC · e9cae7edf554 ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,19 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "HgJUKKID0K"
- }
- ],
- "title": "When Proxy Calibration Controls the Wrong Risk: Accepted-Set Target Mismatch in Selective LLMs",
- "authors": [],
- "abstract": "Selective LLM systems often use inexpensive proxy or judge labels for calibration, but a statistically valid certificate only controls the risk defined by those labels. Does proxy-valid selective calibration control the target risk that deployment actually cares about? We derive an accepted-set identity decomposing the proxy--target risk gap into signed disagreement contributions; global judge agreement alone does not establish transfer. At α = 0.20, the held-out main evaluation shows proxy-label calibration selecting λ = 0.2 with coverage 1.000 and held-out target risk 0.250, whereas target-label calibration selects λ = 1.0 with coverage 0.591 and target risk 0.113. A threshold-wise full-frame diagnostic shows that accepted false-positive contributions outweigh false-negative contributions, producing the proxy–target risk gap. In a 400-row blinded validation sample, human judgments agree with the reference-aware operational target on 96.75%, versus 74.50% with the reference-free proxy. The low-threshold failure reproduces under lenient rubrics across DeepSeek, Qwen, and MiniMax, whereas stricter rubrics can select more conservative thresholds or, in one case, return no solution. Increasing target-label audit budgets improves direct feasibility, whereas proxy-assisted corrections can remain conservative. Selective-risk validity is target-relative: deployment claims require measurement validation and target-specific evidence.",
- "year": 2027,
- "venue": "ICLR 2027 (under review)",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "344acfd6-ea05-41c3-b805-f2f6ebb5a322"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,9 @@
+{
+ "title": "When Proxy Calibration Controls the Wrong Risk: Accepted-Set Target Mismatch in Selective LLMs",
+ "authors": [],
+ "abstract": "Selective LLM systems often use inexpensive proxy or judge labels for calibration, but a statistically valid certificate only controls the risk defined by those labels. Does proxy-valid selective calibration control the target risk that deployment actually cares about? We derive an accepted-set identity decomposing the proxy--target risk gap into signed disagreement contributions; global judge agreement alone does not establish transfer. At α = 0.20, the held-out main evaluation shows proxy-label calibration selecting λ = 0.2 with coverage 1.000 and held-out target risk 0.250, whereas target-label calibration selects λ = 1.0 with coverage 0.591 and target risk 0.113. A threshold-wise full-frame diagnostic shows that accepted false-positive contributions outweigh false-negative contributions, producing the proxy–target risk gap. In a 400-row blinded validation sample, human judgments agree with the reference-aware operational target on 96.75%, versus 74.50% with the reference-free proxy. The low-threshold failure reproduces under lenient rubrics across DeepSeek, Qwen, and MiniMax, whereas stricter rubrics can select more conservative thresholds or, in one case, return no solution. Increasing target-label audit budgets improves direct feasibility, whereas proxy-assisted corrections can remain conservative. Selective-risk validity is target-relative: deployment claims require measurement validation and target-specific evidence.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}