At FullTilt: Real-Time Open-Set 3D Macromolecule Detection Directly from Tilted 2D Projections
Update NeurIPS 2026 submission Eirt5wZqH3: 5 notes
@openreview[bot] · 2026-11-24 15:47 UTC · 350c8ef0ff9c ·
reviews/openreview/eirt5wzqh3/notes/azyw3murzc.json added
+++ b/reviews/openreview/eirt5wzqh3/notes/azyw3murzc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "AZyw3muRZc",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Author Remarks",+ "comment": "We thank all reviewers and area chairs for their careful assessments and insightful comments. We appreciate their recognition of FullTilt’s novelty and sound formulation and design (kg55, uWSJ, SYxv, HEgt), substantial efficiency improvements (kg55, SYxv, HEgt), extensive benchmarking and analysis (kg55, uWSJ, HEgt), and clear presentation (SYxv).\n\nDetailed responses to individual questions are provided under each review. Here, we briefly summarize our responses to recurring questions and welcome further discussion.\n\n**1. Can FullTilt detect non-globular particles?**\n\nYes. FullTilt detects even the most elongated particle in our analysis (axis ratio ∼2.9), and neither AP metric is significantly correlated with axis ratio. Failures instead cluster among very small (<100 kDa) particles, with performance strongly correlated with molecular weight. The single-$d$ formulation therefore does not prevent non-globular detection. Our \"suboptimal localization\" limitation refers to potentially lower localization precision, not an inability to detect such particles.\n\n**2. Does $\\mathcal{G}$ introduce globular bias?**\n\nNo. Significant gains from $\\mathcal{G}$ span the evaluated axis-ratio range, including the most elongated particle, while performance declines for the most globular. Moreover, the gain from $\\mathcal{G}$ is not significantly correlated with axis ratio, providing no evidence of globular bias.\n\n**3. What is the role of $\\mathcal{G}$?**\n\n$\\mathcal{G}$ is not merely an augmentation with geometric primitives. It acts as an auxiliary regularizer that discourages shortcuts based on training-set-specific particle distributions and noise patterns. With limited training data, FullTilt may otherwise overfit to recurring particle-placement or high-frequency noise patterns. $\\mathcal{G}$ generates new tilt series on-the-fly with varied particle placements, noise patterns, and imaging artifacts, thereby improving generalization. Biological shape diversity, however, is provided by the 119 protein structures in the simulated training data, not by $\\mathcal{G}$ alone.\n\n**4. Why is FullTilt relatively weaker on simulated data?**\n\nOne hypothesis is that FullTilt and TomoTwin are susceptible to different simulation-specific shortcuts and may therefore **overfit differently**. Because FullTilt jointly learns localization and classification, it may exploit both particle-placement patterns and high-frequency noise patterns in the limited simulated training set. TomoTwin’s sliding-window subvolume classifier is less exposed to global spatial shortcuts but may still exploit high-frequency noise patterns. Simulated training and test data may share simulator-specific noise statistics while differing in particle placements. TomoTwin’s noise-based shortcuts may therefore transfer to simulated test data, whereas FullTilt’s additional spatial shortcuts may not, leading to a larger simulation generalization gap. **On real-world data, neither method can rely on these simulation-specific cues, so performance more directly reflects their cross-domain generalization capabilities**. This may explain TomoTwin’s relatively stronger simulated performance but weaker real-world performance. The possibility of such shortcuts also motivates $\\mathcal{G}$, which diversifies both particle placements and noise patterns to discourage these shortcuts. We will investigate these shortcut mechanisms further in future work."+ },+ "createdAt": "2026-07-28T17:13:52.601Z",+ "modifiedAt": "2026-11-19T17:11:07.942Z",+ "url": "https://openreview.net/forum?id=Eirt5wZqH3¬eId=AZyw3muRZc",+ "license": "CC-BY-4.0"+}
reviews/openreview/eirt5wzqh3/notes/b8fexootis.json added
+++ b/reviews/openreview/eirt5wzqh3/notes/b8fexootis.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "B8FExOotis",+ "replyTo": "EDKBujJDN4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Author Response",+ "comment": "We thank the Area Chair (`HEgt`) for the careful assessment. We appreciate the recognition of FullTilt's novel formulation for 3D detection directly from 2D tilt-series, substantial efficiency gains, flexible multiclass prompting, and broad experimental evaluation. We address the concerns in detail under each review and provide a brief summary here:\n\n**Statistical test (`kg55`).**\n\nWe provide comprehensive statistical tests. In intra-instance evaluation, FullTilt outperforms all methods across all real-world datasets, with two exceptions against TomoTwin on EMPIAR-10304: [email protected] (comparable with 1 prompt and lower with 2/4 prompts) and F1 (not significant with 2 prompts). In cross-instance evaluation, FullTilt consistently outperforms the baselines on EMPIAR-10499. On CZII, it performs better in [email protected] and F1 and comparably to TomoTwin in mAP@1r. On EMPIAR-10304, it performs comparably to TomoTwin. We also acknowledge the limited statistical power of using 10 trials. Conducting more baseline trials would require several months because of their long runtimes.\n\n**Real-world and simulation benchmarks (`kg55`, `SYxv`).**\n\n- We hypothesize that FullTilt and TomoTwin exhibit different overfitting patterns on the limited simulated training set. Simulation performance may reflect both transferable features and simulator-specific shortcuts, which are difficult to disentangle.\n- On real-world datasets, these simulator-specific shortcuts are unavailable, so performance more directly reflects cross-domain generalization.\n- We further show that broadening the training distribution improves simulated performance while retaining real-world performance (`SYxv`'s [W1, Q2]-2 section). This suggests that training diversity, rather than an inherent architectural limitation, is key to improving performance. Expanding the training distribution is our future work, and we believe FullTilt can provide an efficient foundation for large-scale training.\n\n**Globular-shape bias (`kg55`, `uWSJ`, `SYxv`).**\n\nOur statistical analysis finds no evidence that $\\mathcal{G}$ introduces a globular-shape bias: its gains occur for both globular and non-globular particles and are not significantly associated with axis ratio, supporting generalization across shapes.\n\n**Headline statements (`kg55`).**\n\nWe will clearly qualify each statement regarding uniformly superior performance, prompt scaling, and runtime to avoid any form of overstatement."+ },+ "createdAt": "2026-08-01T20:52:40.243Z",+ "modifiedAt": "2026-11-19T17:11:08.027Z",+ "url": "https://openreview.net/forum?id=Eirt5wZqH3¬eId=B8FExOotis",+ "license": "CC-BY-4.0"+}
reviews/openreview/eirt5wzqh3/notes/edkbujjdn4.json modified
+++ b/reviews/openreview/eirt5wzqh3/notes/edkbujjdn4.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair HEgt","content": {- "metareview": "This manuscript addresses the central challenge of efficient open-set 3D macromolecule detection in cryo-ET by operating directly on aligned 2D tilt series rather than on reconstructed tomograms. Overall, this manuscript is well presented with four main strengths including the novel formulation, substantial efficiency improvements over prior open-set cryo-ET methods, flexible multiclass prompting, and broad experimental evaluation. The claims of the manuscript are generally supported on real-world datasets, however, the accuracy improvements are not always statistically clear, performance is weaker on simulated benchmarks, and the strong dependence on geometric primitives may introduce a globular-shape bias. Some headline statements regarding uniformly superior performance, prompt scaling, and runtime should also be qualified. I advise authors making further clarification on the concerns raised by the reviewers in the rebuttal."+ "metareview": "This manuscript addresses the central challenge of efficient open-set 3D macromolecule detection in cryo-ET by operating directly on aligned 2D tilt series rather than on reconstructed tomograms. Overall, this manuscript is well presented with four main strengths including the novel formulation, substantial efficiency improvements over prior open-set cryo-ET methods, flexible multiclass prompting, and broad experimental evaluation. The claims of the manuscript are generally supported on real-world datasets, however, the accuracy improvements are not always statistically clear, performance is weaker on simulated benchmarks, and the strong dependence on geometric primitives may introduce a globular-shape bias. Some headline statements regarding uniformly superior performance, prompt scaling, and runtime should also be qualified. I advise authors making further clarification on the concerns raised by the reviewers in the rebuttal.",+ "final_justification": "Following the rebuttal and reviewer discussion and further comments, the submission is substantially strengthened. The final reviewer ratings are 5/5/4. The authors provided additional statistical analyses, experiments spanning proteins with a broad range of axis ratios, precision/recall analyses, and extended synthetic-distribution experiments. These additions directly address the earlier concerns about statistical uncertainty, possible bias toward globular particles, and whether the qualitative results implied substantially more false positives. Reviewers kg55 and uWSJ maintained their positive assessments, with Reviewer kg55 increasing confidence, while Reviewer SYxv raised the rating from borderline reject to borderline accept because the new evidence alleviated the main concerns. Some limitations remain: performance is still sensitive to the synthetic training distribution, TomoTwin remains stronger on Sim-OOD AP@1r, and claims of uniformly superior accuracy, prompt scaling, and runtime should be carefully qualified. Nevertheless, the remaining limitations do not outweigh the novelty of operating directly on tilt series, the strong computational advantage, the flexible open-set formulation, and the broad evaluation. On balance, I recommend acceptance. The final revision should incorporate the new analyses and clearly state the remaining Sim-OOD and distribution-sensitivity limitations."},"createdAt": "2026-07-22T15:16:40.623Z",- "modifiedAt": "2026-11-18T15:18:02.811Z",+ "modifiedAt": "2026-11-19T04:58:54.787Z","url": "https://openreview.net/forum?id=Eirt5wZqH3¬eId=EDKBujJDN4","license": "CC-BY-4.0"}
reviews/openreview/eirt5wzqh3/notes/nz0qr8kt0q.json added
+++ b/reviews/openreview/eirt5wzqh3/notes/nz0qr8kt0q.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "nZ0QR8Kt0Q",+ "replyTo": "GBa9NBS91F",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "A Hypothesis for FullTilt’s Weaker Simulation Performance",+ "comment": "One hypothesis is that FullTilt and TomoTwin are susceptible to different simulation-specific shortcuts and may therefore **overfit differently**. Because FullTilt jointly learns localization and classification, it may exploit both particle-placement patterns and high-frequency noise patterns in the limited simulated training set. TomoTwin’s sliding-window subvolume classifier is less exposed to global spatial shortcuts but may still exploit high-frequency noise patterns. Simulated training and test data may share simulator-specific noise statistics while differing in particle placements. TomoTwin’s noise-based shortcuts may therefore transfer to simulated test data, whereas FullTilt’s additional spatial shortcuts may not, leading to a larger simulation generalization gap. **On real-world data, neither method can rely on these simulation-specific cues, so performance more directly reflects their cross-domain generalization capabilities**. This may explain TomoTwin’s relatively stronger simulated performance but weaker real-world performance. The possibility of such shortcuts also motivates $\\mathcal{G}$, which diversifies both particle placements and noise patterns to discourage these shortcuts. We will investigate these shortcut mechanisms further in future work."+ },+ "createdAt": "2026-07-28T18:28:42.508Z",+ "modifiedAt": "2026-11-19T17:11:07.734Z",+ "url": "https://openreview.net/forum?id=Eirt5wZqH3¬eId=nZ0QR8Kt0Q",+ "license": "CC-BY-4.0"+}
reviews/openreview/eirt5wzqh3/notes/vqqynly5kd.json added
+++ b/reviews/openreview/eirt5wzqh3/notes/vqqynly5kd.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vqqYnlY5kd",+ "replyTo": "JbNsgBLaYq",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "A Hypothesis for FullTilt’s Weaker Simulation Performance",+ "comment": "One hypothesis is that FullTilt and TomoTwin are susceptible to different simulation-specific shortcuts and may therefore **overfit differently**. Because FullTilt jointly learns localization and classification, it may exploit both particle-placement patterns and high-frequency noise patterns in the limited simulated training set. TomoTwin’s sliding-window subvolume classifier is less exposed to global spatial shortcuts but may still exploit high-frequency noise patterns. Simulated training and test data may share simulator-specific noise statistics while differing in particle placements. TomoTwin’s noise-based shortcuts may therefore transfer to simulated test data, whereas FullTilt’s additional spatial shortcuts may not, leading to a larger simulation generalization gap. **On real-world data, neither method can rely on these simulation-specific cues, so performance more directly reflects their cross-domain generalization capabilities**. This may explain TomoTwin’s relatively stronger simulated performance but weaker real-world performance. The possibility of such shortcuts also motivates $\\mathcal{G}$, which diversifies both particle placements and noise patterns to discourage these shortcuts. We will investigate these shortcut mechanisms further in future work."+ },+ "createdAt": "2026-07-28T18:26:53.937Z",+ "modifiedAt": "2026-11-19T17:11:07.780Z",+ "url": "https://openreview.net/forum?id=Eirt5wZqH3¬eId=vqqYnlY5kd",+ "license": "CC-BY-4.0"+}