RADIUM: RadioActive Decay of Image-Underlaid Marks
Update NeurIPS 2026 submission szWfyMMMSi: 8 notes
@openreview[bot] · 2026-11-24 15:56 UTC · fa7546c4fc89 ·
reviews/openreview/szwfymmmsi/notes/abi7notzi7.json added
+++ b/reviews/openreview/szwfymmmsi/notes/abi7notzi7.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "aBi7NoTZI7",+ "replyTo": "dA741bMRnD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer hTWX",+ "content": {+ "comment": "I appreciate the authors’ response. After careful consideration, I will maintain my original rating."+ },+ "createdAt": "2026-08-02T19:40:48.945Z",+ "modifiedAt": "2026-11-19T16:45:42.762Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=aBi7NoTZI7",+ "license": "CC-BY-4.0"+}
reviews/openreview/szwfymmmsi/notes/bdaj0jn2qn.json added
+++ b/reviews/openreview/szwfymmmsi/notes/bdaj0jn2qn.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "BDAj0JN2QN",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of the Rebuttal",+ "comment": "We would like to thank the AC and Reviewers for their time and effort invested in the review process of our submission. Your feedback helped us to further improve our paper. We appreciate that the Reviewers find the motivation behind our work solid (Reviewer gGwP) and the study of watermark radioactivity a meaningful contribution (Reviewer 8P3H, hTWX). Our experimental evaluation is described as comprehensive (Reviewer 8P3H), with conclusions that will be useful to the community (Reviewer gGwP). We summarize the whole rebuttal below: \n\n1. **Actionable design factors:** We ranked different design factors supported by new experiments. Key factors are the robustness to training augmentations, VAE encoding and decoding, a reused signal amplified across samples and compatibility to the downstream training regime. \n\n2. **E-process vs T-Test:** We identified and applied e-values and e-processes as a better fit to the problem of radioactivity detection than a standard t-test. They are anytime-valid and non-parametric. E-values speed up the detection process by ~30x due to the possibility of the early stopping or enable detection when the collection of more evidence is required (in our case, past 1000 samples) and if the compute budget allows, which for a t-test would result in p-hacking. \n\n3. **Robustness of the statistical validity:** The type-I error control follows Ville’s inequality applied to wealth. We verified the same-architecture null in the 0% column of Table 1 and introduced whitening in the rebuttal, which removes content-agnostic bias, effectively removing false positives. \n\n4. **Adversarial Robustness:** We analyzed the robustness of our method under augmentations for pre-training, during-training, and post-training. We found that pre-training interventions reduce radioactivity more than post-hoc augmentations. \n\n5. **Transfer to real world settings:** Our core principles, such as VAE robustness as a necessary condition and cross-architecture transfer being strictly harder than same-architecture, should also hold at scale. Since our results provide an empirical upper bound in a controlled setting, watermarks not radioactive here are unlikely to be radioactive in realistic use. We additionally performed an exploratory analysis scaling the fine-tuning samples and training from scratch, which show similar results to our fine-tuning setting. \n\n6. **Novelty:** Unlike prior work in the text domain, RADIUM tracks radioactivity across multiple training-generation cycles, across autoregressive and diffusion architectures, and highly complex image watermarks. \n\n7. **Larger Models:** We added new experimental results for SD3.5 and FLUX.1-dev models. \n\n8. **Inheritance through initialization:** We found that radioactivity is a property of the watermark and architecture specific dynamics. Initializing M3 from M1 has limited impact on radioactivity, and StegaStamp remains radioactive even when the models are trained from scratch (fully random weights), showing that the core effect stems from the watermark, rather than inheritance. \n\n9. **Image quality and detectability degradation:** We computed FID and CLIP scores and show that training on generated data reduces the quality of the downstream model by reinforcing existing biases. We moved Figure 3 to the Appendix and computed the FID and CLIP across model iterations. The image quality and watermark detectability decline together, but this is driven by a common confounder, the iterative training itself, rather than a direct dependence. In a from-scratch experiment, M2 remains radioactive for StegaStamp while producing low-quality images, showing detectability is governed by how well the mark survives repeated training, not by image quality.\n\n10. **Capacity vs. Radioactive lifetime:** For BitMark, a higher bit capacity attenuates the watermark signal and reduces the radioactivity of the watermark. \n\n11. **MIA:** Under the same e-process, RADIUM detects the watermark being part of the training data more efficiently than CLiD and PIAR, despite their stronger assumptions. \n\n12. **Computational cost:** The generation and detection of the watermark depends on the watermark scheme and model architecture. Considering solely the e-process in isolation (without the cost of the inference on the image generative models), the running time is only 0.2 seconds per 1000 samples.\n\n13. **Detection without Key:** We clarified that RADIUM leverages each watermark’s own detection, e.g., the z-score-based watermark detection for BitMark. Furthermore, we evaluated the radioactivity under a key-free setting, by training a ResNet-50 detector. The results show that under perfect access assumptions, a blind detector can replace the original watermark detection scheme and detect the radioactive traces in the M2 model.\n\n---\n\nWe hope that the above clarifications and additional experimental results resolved all concerns."+ },+ "createdAt": "2026-08-03T18:47:07.471Z",+ "modifiedAt": "2026-11-19T16:45:42.760Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=BDAj0JN2QN",+ "license": "CC-BY-4.0"+}
reviews/openreview/szwfymmmsi/notes/g1atnwkoct.json added
+++ b/reviews/openreview/szwfymmmsi/notes/g1atnwkoct.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "G1aTNwkOCT",+ "replyTo": "wB9C2CeJGc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thank you & Summary of our Rebuttal",+ "comment": "Thank you for the answer! We wanted to add that we really appreciate the insightful feedback and that Reviewer found our experimental evaluation solid, with conclusions that will be useful to the community. We provide a summary of our rebuttal below:\n\n1. **E-process vs T-Test:** We identified and applied e-values and e-processes as a better fit to the problem of radioactivity detection than a standard t-test. They are anytime-valid and non-parametric. E-values speed up the detection process by ~30x due to the possibility of the early stopping or enable detection when the collection of more evidence is required (in our case, past 1000 samples) and if the budget allows, which for a t-test would result in p-hacking. \n\n2. **Watermark Detection:** We clarified that RADIUM leverages each watermark’s own detection, e.g., the z-score-based watermark detection for BitMark. \n\n3. **Novelty:** Unlike prior work in the text-domain, RADIUM tracks radioactivity across multiple training-generation cycles, across autoregressive and diffusion architectures, and highly complex image watermarks. \n\n4. **Image quality and detectability degradation:** We moved Figure 3 to the Appendix and computed the FID and CLIP across model iterations. The image quality and watermark detectability decline together, but this is driven by a common confounder, the iterative training itself, rather than a direct dependence. \n\n5. **Detectable watermarks vs. quality:** Watermarking and high-quality generation are not inherently coupled. In a from-scratch experiment, M2 remains radioactive for StegaStamp while producing low-quality images, showing detectability is governed by how well the mark survives repeated training, not by image quality.\n\n6. **Related Work:** We expanded the description of the post-processing and in-generation watermarks and clarified the unique parts of each watermark. The additional description is added to Appendix A. \n\nSince the Reviewer has chosen to maintain the original rating of 4 (Borderline accept), we would greatly appreciate any additional feedback on which aspects of our submission could be further improved. If the clarifications provided above adequately address the Reviewer’s concerns, we would be grateful for any reconsideration or further support of our submission."+ },+ "createdAt": "2026-08-03T11:32:00.707Z",+ "modifiedAt": "2026-11-19T16:45:42.657Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=G1aTNwkOCT",+ "license": "CC-BY-4.0"+}
reviews/openreview/szwfymmmsi/notes/ic2rcxrklp.json added
+++ b/reviews/openreview/szwfymmmsi/notes/ic2rcxrklp.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "iC2RcXRkLP",+ "replyTo": "aBi7NoTZI7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thank you & Summary of our Rebuttal",+ "comment": "We thank the Reviewer for the answer, the constructive feedback, and for finding our paper highly significant, with a reusable evaluation framework and statistical guarantees, which could become part of the standard toolbox for future watermark work. We provide a summary of our rebuttal below:\n\n1. **Robustness of the statistical validity:** The type-I error control follows Ville’s inequality applied to wealth. We verified the same-architecture null in the 0% column of Table 1 and introduced whitening in the rebuttal, which removes content-agnostic bias, effectively removing false positives. \n\n2. **Transfer to real world settings:** Our core principles, such as VAE robustness as a necessary condition and cross-architecture transfer being strictly harder than same-architecture, should also hold at scale. Since our results provide an empirical upper bound in a controlled setting, watermarks not radioactive here are unlikely to be radioactive in realistic use. We additionally performed an exploratory analysis scaling the fine-tuning samples and training from scratch (starting with fully random weights), which show similar results to our original fine-tuning setting. \n\n3. **Inheritance through initialization:** We found that radioactivity is a property of the watermark and architecture specific dynamics. Initializing M3 from M1 has limited impact on radioactivity, and StegaStamp remains radioactive even when the models are trained from scratch, showing that the core effect stems from the watermark, rather than inheritance. \n\n4. **Actionable design factors:** We ranked different design factors supported by new experiments. Key factors are the robustness to training augmentations, VAE encoding and decoding, a reused signal amplified across samples and compatibility to the downstream training regime. \n\nWe are really grateful that the Reviewer supports our submission. We are also happy to provide any additional answers if there are any pending questions that we have not adequately addressed."+ },+ "createdAt": "2026-08-03T14:16:40.568Z",+ "modifiedAt": "2026-11-19T16:45:42.659Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=iC2RcXRkLP",+ "license": "CC-BY-4.0"+}
reviews/openreview/szwfymmmsi/notes/l8kczjnsjp.json added
+++ b/reviews/openreview/szwfymmmsi/notes/l8kczjnsjp.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "l8kczjnsjp",+ "replyTo": "T9E3kDL7o7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "We hope that our clarifications and additional experimental results resolve the Reviewer's concerns",+ "comment": "We thank the Reviewer for the constructive feedback and for recognizing the novelty and practical relevance for long-term provenance tracing of our framing. We provide a summary of our rebuttal below:\n\n1. **Watermark persistence:** We isolated factors that drive watermark persistence, such as generalization, robustness to augmentations and VAE encoding/decoding, model architecture, and static repetitive signals. \n\n2. **Capacity vs. Radioactive lifetime:** For BitMark: a higher bit capacity attenuates the watermark signal and reduces the radioactivity of the watermark. \n\n3. **Contribution:** Unlike the prior work in the text domain, RADIUM tracks radioactivity across multiple training-generation cycles, across autoregressive and diffusion architectures, and for highly complex image watermarks. \n\n4. **Pre-training Scale:** We performed an exploratory analysis for training from scratch and larger scale fine-tuning. The results remain comparable to our original fine-tuning setting. \n\n5. **Larger Models:** We added new experimental results for SD3.5 and FLUX.1-dev models that align with the SD2.1 findings.\n\n6. **Adversarial Robustness:** We analyzed the robustness of our method under augmentations for pre-training, during-training, and post-training. We found that pre-training interventions reduce radioactivity more than post-hoc augmentations. \n\n7. **MIA:** Under the same e-process, RADIUM detects membership more efficiently than CLiD and PIAR, despite their stronger assumptions. \n\n8. **Computational cost:** The generation and detection of the watermark depends on the watermark scheme and model architecture. Considering solely the e-process in isolation (without the cost of the inference on the image generative models), the running time is only 0.2 seconds per 1000 samples.\n\n9. **Model Quality:** FID and CLIP scores show that training on generated data reduces the quality of the downstream model by reinforcing existing biases. \n\n10. **Detection without Key:** We evaluated the radioactivity under a key-free setting, by training a ResNet-50 detector. The results show that under perfect access assumptions, a blind detector can replace the original watermark detection scheme and detect the radioactive traces in the M2 model.\n\n--- \n\nWe hope that the above clarifications and additional experimental results resolve the Reviewer's concerns. We would really highly appreciate it if the Reviewer could further support our submission and increase the rating."+ },+ "createdAt": "2026-08-03T13:49:31.531Z",+ "modifiedAt": "2026-11-19T16:45:42.738Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=l8kczjnsjp",+ "license": "CC-BY-4.0"+}
reviews/openreview/szwfymmmsi/notes/nbfxi6birv.json modified
+++ b/reviews/openreview/szwfymmmsi/notes/nbfxi6birv.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair grZ8","content": {- "metareview": "The paper presented an interesting new concept - watermark persistence in subsequent generations or radioactivity. After a lively discussion all outstanding concerns were resolved. All reviewers recommended acceptance and the AC agreed. Accept."+ "metareview": "The paper presented an interesting new concept - watermark persistence in subsequent generations or radioactivity. After a lively discussion all outstanding concerns were resolved. All reviewers recommended acceptance and the AC agreed. Accept.",+ "final_justification": "All reviewers and AC judged the idea to be sufficiently interesting and evidence substantial for the concept and feasibility track."},"createdAt": "2026-07-21T19:05:57.927Z",- "modifiedAt": "2026-11-18T15:18:05.993Z",+ "modifiedAt": "2026-11-19T04:58:54.543Z","url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=NBfXI6BirV","license": "CC-BY-4.0"}
reviews/openreview/szwfymmmsi/notes/t9e3kdl7o7.json added
+++ b/reviews/openreview/szwfymmmsi/notes/t9e3kdl7o7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "T9E3kDL7o7",+ "replyTo": "Tx9ZanS9Za",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additions to the rebuttal",+ "comment": "We would again like to thank the Reviewer for their questions. Below, we provide additional results for further clarification.\n>**W1&W8&Q1 Watermark Persistence**\n\nWe further extend the analysis of the factors that influence radioactivity based on our initial rebuttal response:\n\n#### **1. Generalisation vs. Memorization**\n\nOur work analyzes two different knowledge assumptions concerning the prompts of the training images of M2. The supervised setting, where Alice knows the prompts of the images used by Bob and the unsupervised setting, where she does not. Our main results in Tables 1, 2 and 3 show that prompt access has limited impact on the detection of radioactivity, with the supervised and unsupervised setting agreeing in 172/175 cases. This prompt independence shows that radioactivity is not an artifact of memorizing the mark in combination to a specific training image, but a general capability of the model. Thus, in the remaining part of this comment, we operate in the unsupervised setting.\n\n#### **2. Watermark Robustness**\n\nWe provide our analysis of the impact of watermark robustness on the radioactivity in our answer to your [W5&Q7](https://openreview.net/forum?id=szWfyMMMSi#discussion:~:text=W5%26Q7%20Adversarial%20Robustness), where in-training augmentations, such as horizontal flipping, can distort the watermark signal, reducing (or even in some cases, e.g., for RivaGAN removing) the overall radioactivity of the watermark. \n\n#### **3. Watermark Exposure**\n\nWe notice that different training schemes (autoregressive vs. diffusion) have an impact on the radioactivity of the different models. The autoregressive Infinity model is trained by predicting every scale of a given image and performing gradient descent on the cross entropy loss. In SD2.1, only a single noise vector is sampled, added to the image and the model has to predict the added noise. The information that is learned per image thus highly depends on the sampled timestep. \n\nTherefore, we ablate the impact of the timesteps sampled on the radioactivity of the watermark. Specifically we compare our default setting, where during training, we sample from timesteps in the range of 0 (clean image) to 1000 (pure noise) to sampling from ranges 0 to 500 and 500 to 1000. We train on 100% watermarked StegaStamp images and report the mean bit accuracy in M2. We observe that sampling the noise from timesteps 0 to 500 enables StegaStamp to transfer stronger to M2. StegaStamp signal is disrupted by the noise at high sampling ranges (500-1000). Ensuring that the mark is exposed during training is therefore prerequisite for radioactivity. \n\nModel|TimeSteps during training|E-value|Mean bit accuracy M2\n-|-|-|-\nSD2.1|[0,1000)|35|0.870\nSD2.1|[0,500)|33|0.924\nSD2.1|[500,1000)|0.011|0.492\n\n#### **4. Repeated Patterns**\n\nAs the model has to learn the watermark, the watermark pattern needs to be seen multiple times during training. Radioactivity thus requires the reuse of the same key or pattern across multiple samples or within samples, such as reusing the same bit-pattern (BitMark). As further analysis, we train M2 on a dual key setup, where 50% of the data is marked with key A and the other 50% with key B. We consider StegaStamp and report results on 100% watermarked data used in model M2.\n\nWatermark|Model|Setting|E-value|Mean Bit Accuracy\n-|-|-|-|-\nStegaStamp|SD2.1|Single Key|56|0.651\n||Dual Key (Key A / Key B)|101 / 95|0.550 / 0.565\n|Inf-2b|Single Key|34|0.755\n||Dual Key (Key A / Key B)|44/43|0.619 / 0.656\nRivaGan|SD2.1|Single Key|813|0.523\n||Dual Key (Key A / Key B)|10.9 / 1.81|0.519 / 0.514\n|Inf-2b|Single Key|45|0.822\n||Dual Key (Key A / Key B)|58 / 44|0.676 / 0.768\n\nOur results show that using two keys rather than one reduces the detectability of the watermark, due to less per key exposure during training, effectively reducing the amount of training data for each key.\n>**W4 Larger Model**\n\nWe also implemented and analysed FLUX.1-dev, fine-tuning for 5 epochs on 5k samples with a learning rate of 5e-6.\n\nWatermark|0%|25%|50%|100%\n-|-|-|-|-\nStegaStamp|0.03|0.34|103|55\nRivaGAN|2.02|565|368|58\nSIREN|0.07|786|96|39\nTrustMark|0.02|0.12|0.14|0.04\n\nRivaGAN and SIREN are radioactive when making up 25% or more of the fine-tuning data, with StegaStamp becoming radioactive at 50%. TrustMark is not radioactive on any fraction, consistent with the behavior on other backbones.\n\n>**W5&Q7 Adversarial Robustness**\n\nWe additionally evaluated the robustness of the data generated by the radioactive M2 model that was trained on 100% BitMark data.\n\nBitMark|1%|5%|10%|25%|100%\n-|-|-|-|-|-\nClean|132|78|47|46|34\nCrop|3.93|78.83|687|55|34\nFlip|2.32|1.31|0.67|83|38\nJPG|188|126|66|37|34\nCombined|1.359|0.115|0.431|383|70\n\nComparing the results with the pre-training augmentations, post-hoc attempts are less successful at disrupting the radioactivity.\n\n---\nWe hope that our results adequately address the Reviewers' concerns. If any questions remain, we would be happy to address them."+ },+ "createdAt": "2026-07-31T13:57:55.427Z",+ "modifiedAt": "2026-11-19T16:45:42.819Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=T9E3kDL7o7",+ "license": "CC-BY-4.0"+}
reviews/openreview/szwfymmmsi/notes/wb9c2cejgc.json added
+++ b/reviews/openreview/szwfymmmsi/notes/wb9c2cejgc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wB9C2CeJGc",+ "replyTo": "NtrgEvWDpy",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer gGwP",+ "content": {+ "comment": "I appreciate the authors’s reply. I maintain my original rating"+ },+ "createdAt": "2026-08-03T08:56:07.340Z",+ "modifiedAt": "2026-11-19T16:45:42.760Z",+ "url": "https://openreview.net/forum?id=szWfyMMMSi¬eId=wB9C2CeJGc",+ "license": "CC-BY-4.0"+}