L-Flow: Longitudinal Flow Matching for Progression-Aware Speech Biomarker Modeling
Import NeurIPS 2026 submission cWCFhDk4uC: 5 notes
@openreview[bot] · 2026-11-22 17:58 UTC · ff2bb6442256
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,22 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "cWCFhDk4uC"+ }+ ],+ "title": "L-Flow: Longitudinal Flow Matching for Progression-Aware Speech Biomarker Modeling",+ "authors": [+ "Enshi Zhang",+ "Christian Poellabauer"+ ],+ "abstract": "Speech is an increasingly promising biomarker for neurodegenerative disorders due to its non-invasive nature, low cost, and suitability for frequent, longitudinal monitoring. However, existing clinical speech datasets are typically small, sparse, and irregularly sampled, limiting the ability to model continuous disease progression and develop robust biomarkers. We propose L-Flow, a progression-aware conditional speech generation framework for longitudinal speech trajectory completion. Given a patient’s speech recordings, timestamps, and clinical progression labels, L-Flow learns a query-specific progression representation to synthesize speech at intermediate time points within the observed recording span. Experiments on two real-world longitudinal speech datasets demonstrate that L-Flow generates synthetic speech with stronger progression consistency than eight baseline augmentation methods. In addition, incorporating L-Flow–augmented data improves downstream regression performance to predict clinical severity, highlighting its utility for speech-based biomarker development.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/cwcfhdk4uc/forms.json added
+++ b/reviews/openreview/cwcfhdk4uc/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/cwcfhdk4uc/notes/0azlr2dbpa.json added
+++ b/reviews/openreview/cwcfhdk4uc/notes/0azlr2dbpa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "0aZLr2dBPA",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair QTaB",+ "content": {+ "metareview": "The paper proposes L-Flow, a conditional flow-matching framework that generates longitudinal clinical speech to simulate neurodegenerative disease progression. By synthesizing intermediate speech samples for data augmentation, L-Flow demonstrates stronger progression consistency than baselines and improves downstream performance on clinical severity regression tasks.\n\nStrengths:\n- Tackles a highly motivated, clinically significant problem for rare speech disorders.\n- Well-executed methodology Demonstrates clear improvements in downstream regression performance on held-out data.\n\nWeaknesses:\n- Word Error Rate (WER) is ill-suited for degrading atypical speech. The evaluation lacks localized acoustic analysis (e.g., formants, jitter) and human perceptual evaluation.\n- Missing confidence intervals, p-values, and cross-validation details make it difficult to verify the significance of the results (Tables 2-5).\n- Progression consistency scores may artificially benefit from the evaluation's deterministic linear interpolation. A simpler \"linear blending\" baseline is missing.\n- Details regarding training mask ratios and hyperparameter validation (for $\\lambda_{prog}$ and $\\lambda_{ord}$) are ambiguous.\n- The limitations section is incorrectly relegated to the appendix.\n\nTo secure a strong recommendation for acceptance, the authors should address the weaknesses"+ },+ "createdAt": "2026-07-23T04:34:19.369Z",+ "modifiedAt": "2026-11-18T15:18:08.024Z",+ "url": "https://openreview.net/forum?id=cWCFhDk4uC¬eId=0aZLr2dBPA",+ "license": "CC-BY-4.0"+}
reviews/openreview/cwcfhdk4uc/notes/0rx5ghnrxa.json added
+++ b/reviews/openreview/cwcfhdk4uc/notes/0rx5ghnrxa.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "0RX5GhnRXa",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer UTxa",+ "content": {+ "summary": "Speech can offer key insights into disease progression (for cases of neurodegenerative diseases,) however dataset size, sparsity, and timestamp inconsistency can make this training paradigm difficult compared to traditional speech training. L-Flow takes the speech at provided timestamps and generates speech data at intermediate time points, simulating different stages of disease progression, allowing for more complete training. This resulted in widely improved performance on held-out data using modern ASR models, demonstrating a key contribution of medical speech data in the field of language processing.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\n1. Strong improvements. The synthesized datasets yielded largely improved accuracy metrics, on average performing best or second best compared to other notable medical speech datasets. The experiment was rigorous, covering all angles of exploration with ablations and speech validity.\n2. Tables of results are highly informative, highlighting key areas to focus on, which largely encompass improved results from L-Flow datasets across the main models utilized. The authors reported comprehensive error measurements that cover most conventional selection criteria (absolute error, mean squared error, and correlation) and account for progression during ablation.\n3. The problem is highly motivated and justified, supported with an in-depth literature review in the related works section. The problem is then directly addressed and explained in the following sections, grounded in mathematical explanation and experimental procedure.\n\nWeaknesses:\n1. Flow. Sometimes, transitions between paragraphs within a section can seem jarring. While not a critique I will use to detract from my score, I personally would recommend smoothing out some of the transitions.\n2. Significance of tables. Results tables (2-5) demonstrate noticeable improvements from utilization of L-Flow, however statistical significance is not addressed to my knowledge. An 80-20 split was utilized for creation of a held-out set, but was cross-validation done during training? It is hard to assess the degree of improvement without more information on the variance for the error estimates. I have selected a preliminary significance score of 2, however this will likely be updated as part of the rebuttal period.\n3. Density of tables. The results tables, while organized, are very large and dense with information, making digestion somewhat difficult. I recognize and appreciate the necessity for organization, and reporting all of these important results for the different models and datasets.\n4. Table captions are one or two sentences, with little guidance for interpreting the tables or at which areas to emphasize. Table captions should serve as a light summary of the table itself, including key explanations and conclusions.",+ "quality": 3,+ "clarity": 3,+ "significance": 4,+ "originality": 3,+ "questions": "1. What are the reported p-values for accuracy/error metrics for tables 2-5? Was cross-validation done during training? If so, what was the fold performance? \n2. How much was training time affected by utilization of L-Flow? I would expect with the incorporation of more data (which is being infilled between the true observations) that the time to train would grow - how did this compare with the baseline datasets utilized?\n3. Were there any instances of evaluation where the imputation of intermediate speech patterns were detrimental to model performance? Such as a particular pre-existing model or dataset, or specific model architecture?\n4. How was speech validity assessed? I am unfamiliar with this procedure, and request further explanation from the authors.",+ "limitations": "Yes, though it is included in the appendix. I think it is important for these limitations to be addressed in the main body of the paper, since the appendix may not be read by everyone.",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I would recommend this paper for acceptance. The concent and quality of the submission was already high in spite of my concerns and comments, which were addressed in full as part of the rebuttal period. I am now confident in believing the author's claims of the performance with the added inclusion of fold performance and statistical measures, which was my major concern outside of small organizational issues. Overall, I think this would make a good inclusion for the proceedings."+ },+ "createdAt": "2026-06-23T20:19:23.231Z",+ "modifiedAt": "2026-11-18T13:34:49.567Z",+ "url": "https://openreview.net/forum?id=cWCFhDk4uC¬eId=0RX5GhnRXa",+ "license": "CC-BY-4.0"+}
reviews/openreview/cwcfhdk4uc/notes/erxg6zuyhl.json added
+++ b/reviews/openreview/cwcfhdk4uc/notes/erxg6zuyhl.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "erxg6ZuyhL",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Q1VL",+ "content": {+ "summary": "The paper introduces L-Flow, a flow-matching framework designed for progression-aware clinical speech generation in neurodegenerative diseases like ALS and Parkinson's. The core innovation lies in the integration of longitudinal history and multi-dimensional constraints (text, reference signal, and progression labels) to ensure \"progression consistency.\" The study is well-motivated; they tackle a significant challenge—moving from high-fidelity voice cloning to clinically meaningful, time-aligned speech synthesis.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strengths**\n1. Novel Application & Impact: Applying flow matching to address longitudinal clinical trajectories in rare diseases is highly relevant and offers significant potential for health monitoring tools.\n2. Multi-dimensional Evaluation: The authors go beyond standard metrics (like WER) by introducing \"Progression Consistency\" ($\\tau, \\rho$), which effectively measures whether the model captures the latent trajectory of disease progression.\n3. Strong Baselines: Comparing L-Flow against state-of-the-art TTS systems (e.g., Qwen3_TTS, XTTS-v2) and pathology-specific models (SCP-TTS) provides a robust benchmark for its specific technical contributions.\n\n**Weaknesses**\n1. Ambiguity in Training Hyper-parameters: The paper mentions that $\\lambda_{prog}$ and $\\lambda_{ord}$ are selected based on validation data, but the specification of the validation set is missing. These weights significantly impact the balance between \"speaking identity\" and \"clinical progression,\" and so is critical for reproducibility. \n2. Lack of masking ratio: While the transition from partial masks in training to full-sample generation in inference is a standard approach (similar to some self-supervised models), the lack of a defined mask ratio during training makes it difficult to assess the model's reliance on residual signal versus its integration of provided constraints. A more detailed description of this transition would clarify how much the model is \"filling gaps\" versus \"understanding the trajectory.\"\n3. Potential Circularity in Evaluation: The high scores in \"Progression Consistency\" may partially stem from a circular logic: since $\\tilde{y}$ is derived via deterministic linear interpolation (Eq. 9), any model following this predefined path will achieve high consistency regardless of its architecture. To isolate the specific value added by Flow-matching, the authors should compare L-Flow against a simpler baseline—such as linear blending of latent features—to distinguish learned dynamics from the evaluation's design.\n4. Comparison of Utility: While L-Flow excels in several metrics, the gap between it and state-of-the-art systems like Qwen3_TTS or SCP-TTS is sometimes narrow. A clearer discussion on what specific \"information\" L-Flow provides that these models lack (other than just higher consistency) would strengthen the argument for its superiority.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Training & Hyperparameter Specifics: Could the authors clarify two points regarding the training setup: (1) what was the specific mask ratio used during training? (2) how were $\\lambda_{prog}$ and $\\lambda_{ord}$ determined? Since only a train/test split is mentioned, more detail on the validation process for these hyperparameters would help clarify their role in the model's performance.\n\n2. Evaluating Model Dynamics vs. Evaluation Design: There is a concern that \"Progression Consistency\" may partially reflect the deterministic nature of $\\tilde{y}$ (Eq. 9) rather than L-Flow’s ability to learn complex dynamics. To isolate the unique value of the Flow-matching framework, could the authors: (a) compare L-Flow against a \"linear blending\" baseline (e.g., linear interpolation of latent features); and (b) clarify what specific clinical information or non-linear patterns L-Flow captures that this simpler baseline does not?",+ "limitations": "yes",+ "rating": 5,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "none",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "During the rebuttal period, the authors provided clear clarifications regarding masking specifics and hyper-parameter selection. Furthermore, the inclusion of additional comprehensive experiments has strengthened the evaluation of the proposed method. These improvements address my initial concerns, and I now recommend this paper for acceptance."+ },+ "createdAt": "2026-06-26T04:48:25.366Z",+ "modifiedAt": "2026-11-18T13:34:48.010Z",+ "url": "https://openreview.net/forum?id=cWCFhDk4uC¬eId=erxg6ZuyhL",+ "license": "CC-BY-4.0"+}
reviews/openreview/cwcfhdk4uc/notes/esor7ial2t.json added
+++ b/reviews/openreview/cwcfhdk4uc/notes/esor7ial2t.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "eSOr7iaL2T",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper proposes L-Flow, a conditional flow-matching framework that generates longitudinal clinical speech to simulate neurodegenerative disease progression. By synthesizing intermediate speech samples for data augmentation, L-Flow demonstrates stronger progression consistency than baselines and improves downstream performance on clinical severity regression tasks.\n\nStrengths:\n- Tackles a highly motivated, clinically significant problem for rare speech disorders.\n- Well-executed methodology Demonstrates clear improvements in downstream regression performance on held-out data.\n\nWeaknesses:\n- Word Error Rate (WER) is ill-suited for degrading atypical speech. The evaluation lacks localized acoustic analysis (e.g., formants, jitter) and human perceptual evaluation.\n- Missing confidence intervals, p-values, and cross-validation details make it difficult to verify the significance of the results (Tables 2-5).\n- Progression consistency scores may artificially benefit from the evaluation's deterministic linear interpolation. A simpler \"linear blending\" baseline is missing.\n- Details regarding training mask ratios and hyperparameter validation (for $\\lambda_{prog}$ and $\\lambda_{ord}$) are ambiguous.\n- The limitations section is incorrectly relegated to the appendix.\n\nTo secure a strong recommendation for acceptance, the authors should address the weaknesses",+ "final_justification": "After reviewing the discussion, the original score is maintained."+ },+ "createdAt": "2026-09-24T11:15:56.872Z",+ "modifiedAt": "2026-11-18T14:52:09.544Z",+ "url": "https://openreview.net/forum?id=cWCFhDk4uC¬eId=eSOr7iaL2T",+ "license": "CC-BY-4.0"+}
reviews/openreview/cwcfhdk4uc/notes/pnnb0hra0x.json added
+++ b/reviews/openreview/cwcfhdk4uc/notes/pnnb0hra0x.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "PnNb0hra0X",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Qb6H",+ "content": {+ "summary": "This paper present a novel approach to model progressive speech disorders as data augmentation technique, specifically for disorders such as ALS and Parkinson’s disease. L-flow, is a flow matching TTS model that is conditioned on the scalar severity level and speech history encoded as longitudinal context. The authors show that their model achieves superior performance in progression ordering consistency, and as data augmentation on simple severity regressors against baselines, while achieving competitive speaker similarity and intelligibility preservation. \n\nWhile this approach is very significant for improving and modeling neurodegenerative disease in speech, the current evaluation lacks sufficient depth in the investigation of feature preservation and speech modeling as well as human perceptual evaluation. Furthermore, the lack of supplementary audio samples makes the qualitative assessment difficult.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "S1: Targets an important, high impact and relevant research direction in clinical speech processing and longitudinal disease modeling. \n\nS2: Novel progression-conditioned TTS model, well executed model with a custom progression encoder. The design choices are systematically verified via an ablation study.\n\nS3: Evaluation across several dimensions including speech quality, progression consistency and data augmentation effectiveness.\n\nS4: The paper is generally well written and structurally clear. Implementation details and source code are provided.\n\nW1: Unsatisfactory evaluation methodology, the evaluation framework is somewhat misaligned with the nature of atypical speech. WER to a clean ground truth text is ill-posed for this setting, and the analysis omits localized feature preservation metrics and fine-grained, per-severity-level investigation.\n\nW2: Lack of human evaluation and supplementary audio samples.\n\nW3: Missing significance/confidence intervals, making it difficult to truly asses the performance gains.\n\nW4: Missing limitations from the main body of the paper.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "Q1. The current evaluation metrics are not satisfactory. While I appreciate the authors wanted to quantify whether the model was producing acceptable speech, I believe a more important question is whether the model is appropriately modeling the progression, not just merely generally speaking speech. Beside, the WER and speaker similarity metrics can be inadequate in this setting as it is atypical speech and SSL models are not trained on that domain. In fact, you would want WER to drop as the severity increases. Instead, I would expect evaluation per severity and utterance level phoneme distance when ground truth is available or distributional metrics if data size allows. I'm also missing the whole acoustic analysis (formants, pitch, jitter/shimmer, etc...) that are relevant to these conditions per severity levels, normalised per speaker. \n\nQ2. Similarly, human evaluation is missing to properly assess the modeling performance. If possible, a small-scale human perceptual study assessing the modelling capability of the simulated progression would help with the current evaluation gap.\n\nQ3.It is difficult to asses whether the conditioned model is indeed a better augmentation approach than the baselines TTS models as there is no statistical tests or confidence intervals and the values are quite close. Could the authors add statistical testing or if not possible, justify why.\n\nQ4. For the severity and condition prediction, why were only simple regressors chosen? Evaluating the augmented data against existing SOTA classifiers trained on these exact public datasets would significantly strengthen the case for the utility of L-flow. If not available/existing, please clarify.\n\nQ5. What was the rationale behind training the generative flow model entirely from scratch? Have the authors experimented with initializing the generator weights using a high-quality pretrained TTS checkpoint and then fine-tuning with the condition modules and progression encoder? I would welcome intuition on whether this would hinder or improve the model’s trajectory alignment.\n\nQ6. If possible, please include example samples for different speakers, at different severity levels for ALS and Parkinson's. Ideally, for each baseline as well.\n\nQ7. For format and clarity integrity, limitations should have been clearly stated in the body of the paper and not the appendices.",+ "limitations": "yes",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "Limitations not in the main body of the paper, while it is required. Appendices are not expected to be considered.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The new analyses addressed my main concern and improved rigor. I updated my rating accordingly to 4 (Borderline accept)."+ },+ "createdAt": "2026-06-26T10:09:28.051Z",+ "modifiedAt": "2026-11-18T13:34:46.086Z",+ "url": "https://openreview.net/forum?id=cWCFhDk4uC¬eId=PnNb0hra0X",+ "license": "CC-BY-4.0"+}
reviews/openreview/cwcfhdk4uc/submission.json added
+++ b/reviews/openreview/cwcfhdk4uc/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "cWCFhDk4uC",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 576,+ "url": "https://openreview.net/forum?id=cWCFhDk4uC",+ "license": "CC-BY-4.0"+}
versions/v_sw3f55kv.json added
+++ b/versions/v_sw3f55kv.json@@ -0,0 +1,22 @@+{+ "date": "2026-04-15",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 576,+ "url": "https://openreview.net/forum?id=cWCFhDk4uC",+ "reviews": "openreview/cwcfhdk4uc",+ "evidence": [+ "https://openreview.net/forum?id=cWCFhDk4uC"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=cWCFhDk4uC",+ "evidence": [+ "https://openreview.net/forum?id=cWCFhDk4uC"+ ]+}