CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy
Update NeurIPS 2026 submission 0WaapzByGt: 13 notes
@openreview[bot] · 2026-11-24 15:44 UTC · 51c6402cbc74 ·
reviews/openreview/0waapzbygt/notes/aenmbunqlk.json added
+++ b/reviews/openreview/0waapzbygt/notes/aenmbunqlk.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "AeNMbuNqlk",+ "replyTo": "fxf3YbUQcX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer 82mA,\n\nThank you for your valuable comments and constructive feedback.\n\nAs the discussion period approaches its end, we would like to kindly ask whether our responses have sufficiently addressed your concerns and questions. Please feel free to let us know if any further clarifications, explanations, or experiments are needed. We are more than happy to elaborate.\n\nMany thanks for all your time and efforts. We truly appreciate it.\n\nThe Authors"+ },+ "createdAt": "2026-08-01T22:29:45.874Z",+ "modifiedAt": "2026-11-19T17:20:34.615Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=AeNMbuNqlk",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/afrrd9toqk.json added
+++ b/reviews/openreview/0waapzbygt/notes/afrrd9toqk.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "afrRD9toqk",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of Discussion Phase",+ "comment": "We thank the AC for the clear synthesis of the reviews, which helped us focus our response. We have worked to address all three requirements raised in the meta-review to the best of our ability.\n\nWe thank all three reviewers for their careful reading and constructive engagement throughout the discussion. The suggested experiments, namely the learned baselines (NeRF-like MLP, FILM, bilinear), the leakage audit, and the planned expert evaluation, have substantially strengthened the paper.\n\nTo Reviewers BWXy and BUtu: thank you for confirming that your concerns were addressed, and for the score increases. We are grateful for the time you invested.\n\nTo Reviewer 82mA: thank you for the follow-up and for raising important points for clarification. In our latest response, we aimed to clarify that CD-RCM is not an optical super-resolution or deconvolution method, as it does not break the diffraction limit or recover spatial frequencies absent from the measurements. It performs continuous-depth resampling of an already band-limited volume, exploiting the overlap between optical sections (sampled at 1.5 $\\mu$m, finer than the ~3–5 $\\mu$m optical section thickness) together with learned cross-stack priors. We will revise the manuscript to make this distinction explicit, narrow our claim regarding Plücker embeddings (adding an encoding comparison if space permits), and discuss the microscopy-inverse-problem works you noted (Cao et al., Kang et al., Müller et al.). As the discussion period closes, we would welcome knowing whether these clarifications address your remaining concern, and are glad to provide anything further."+ },+ "createdAt": "2026-08-03T20:15:44.628Z",+ "modifiedAt": "2026-11-19T17:20:33.987Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=afrRD9toqk",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/bioc85lyff.json added
+++ b/reviews/openreview/0waapzbygt/notes/bioc85lyff.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "BIoC85lyFF",+ "replyTo": "H9bU9CvvuY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 82mA (1/2)",+ "comment": "We thank the reviewer for this thoughtful clarification. We agree that our previous wording may have led to an interpretation that is stronger than we intended. CD-RCM is not an optical super-resolution or deconvolution method, for it does not break the diffraction limit, recover spatial frequencies absent from the acquired measurements, or improve the microscope’s intrinsic axial optical resolution. As stated in the paper, the method performs computational depth densification within the resolution limits of the imaging system. We believe there is an important distinction between improving the optical resolving power of the microscope and increasing the sampling density of an already diffraction-limited image volume. Our work addresses the latter.\n\nWe respectfully disagree with the characterization that our objective is optical super-resolution. Rather than recovering structures beyond the optical resolving capability of the microscope, our method estimates intermediate diffraction-limited optical sections between overlapping measurements while preserving the morphology of tissue structures that are already resolved by RCM.\n\nBy stating that our objective is “not simply to produce visually smooth transitions,” we did not intend to imply that CD-RCM resolves sub-diffraction structures. Rather, we intended to distinguish morphology-aware interpolation from interpolation based solely on pixel-wise smoothness. Clinical RCM already resolves many diagnostically relevant tissue structures, including keratinocytes, melanocytes, dermal papillae, melanocytic nests, and capillary loops, whose characteristic dimensions are substantially larger than the axial optical section thickness (~3–5 μm). Conversely, structures below the microscope's resolving power (e.g., organelles, or cell membranes) are not present in the acquired data and therefore cannot be recovered by our method. \n\nImportantly, our acquisition protocol samples the tissue every 1.5 $\\mu$m in depth, which is finer than the microscope's axial optical section thickness (~3–5 $\\mu$m) (Section 4.1, Dataset, line 227). Consequently, neighboring optical sections already contain substantially overlapping information from the same tissue volume rather than independent observations. CD-RCM exploits this redundancy, together with structural priors learned across the training data, to estimate anatomically consistent intermediate optical sections. This should therefore not be interpreted as recovering information beyond the diffraction limit, but rather as reconstructing a continuous representation of tissue morphology that remains consistent with both the acquired measurements and the optical limits of RCM. The resulting representation has denser axial sampling, but unchanged intrinsic optical resolution.\nWe will revise the camera ready paper to make this distinction explicit. In particular, we will replace language such as “isotropic volume” with “isotropically sampled volume” or “axially densified volume,” and clarify that the synthesized sections cannot reveal structures that were unresolved by the original imaging system. We will also explicitly distinguish isotropic voxel sampling from isotropic optical resolution, as only the former is the objective of our method. The purpose is therefore continuous-depth visualization and resampling of the band-limited RCM volume, not physical super-resolution.\n\nWe also appreciate the reviewer’s point regarding the representation of the depth query. The current experiments establish the value of the overall continuous-depth, cross-stack formulation, but they do not establish that Plücker embeddings are uniquely superior to simpler depth encodings. We adopted Plücker embeddings to express input and target rays within a common view-synthesis representation and to retain compatibility with the underlying transformer architecture. We do not claim that Plücker embeddings are the optimal encoding for this problem. However, given the pure axial acquisition geometry of RCM, scalar depth encodings, Fourier positional encodings, or learned depth embeddings are reasonable alternatives. We will narrow our claim accordingly and, if space permits, add an ablation comparing Plücker embeddings against simpler depth-query representations. The central contribution is the amortized formulation in which axial position is treated as a continuous, queryable variable—not a claim that Plücker coordinates are the only possible encoding."+ },+ "createdAt": "2026-08-03T17:35:08.941Z",+ "modifiedAt": "2026-11-19T17:20:34.435Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=BIoC85lyFF",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/ejzcuwmdbx.json added
+++ b/reviews/openreview/0waapzbygt/notes/ejzcuwmdbx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "eJZcuwmDBX",+ "replyTo": "olxu5xXEBX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer BWXy",+ "content": {+ "comment": "I thank the authors for addressing the main issues raised in the review. My main concerns have been addressed."+ },+ "createdAt": "2026-08-02T14:37:12.022Z",+ "modifiedAt": "2026-11-19T17:20:34.571Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=eJZcuwmDBX",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/h9bu9cvvuy.json added
+++ b/reviews/openreview/0waapzbygt/notes/h9bu9cvvuy.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "H9bU9CvvuY",+ "replyTo": "fxf3YbUQcX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 82mA",+ "content": {+ "title": "Response to rebuttal",+ "comment": "Thank you for the clarifications and the additional experiments to compare against other interpolation methods. Because the user study for diagnostic improvement is not yet complete, I cannot evaluate its impact on the work. Though I do agree that such a study would be useful to include.\n\nHowever, I still take issue with the framing or motivation of the work. I avoided discussion of resolution in my original review because the work was explicitly framed as being about visualization, but if the goal is \"not simply to produce visually smooth transitions\" between slices but really to increase the resolvable features, then this discussion is unavoidable but missing from the work. The fact that different cellular structures have complicated spatial distributions across depth is something that no interpolation or view synthesis can resolve better than the diffraction limit. In this case, the goal is really to perform super-resolution. The method as presented would only be able to perform this super-resolution due to the structural priors learned by the model across the training data of various tissue samples (assuming all the data is from exactly the same microscope with the same point spread function). But that data itself is still diffraction limited by the point spread function, and there is no physical strategy to break the diffraction limit (e.g. structured illumination). So it is not clear in what way the method is not just about learning smooth transitions between diffraction limited planes.\n\nFurther, it is possible that this architecture combining Transformers and Plücker embeddings is a good approach for performing this kind of super-resolution on this particular modality, but then there are also no discussions or experiments regarding why this particular embedding is better than others (e.g. random, position encoding, some kind of learnable encodings (\"Instant neural graphics primitives with a multiresolution hash encoding\", Müller et al. SIGGRAPH 2022), etc.) or references to other relevant work using microscopy and neural representations for deconvolution, e.g. \"Neural space–time model for dynamic multi-shot imaging\", Cao et al. Nature Methods 2024 or \"Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields\", Kang et al. Nature Methods 2026 (though these works optimize per-sample neural representations rather than the amortized approach taken here).\n\nFor this reason, I will maintain my score."+ },+ "createdAt": "2026-08-03T04:00:26.965Z",+ "modifiedAt": "2026-11-19T17:20:34.229Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=H9bU9CvvuY",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/jbfokjbmpw.json added
+++ b/reviews/openreview/0waapzbygt/notes/jbfokjbmpw.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "JBfoKjbmpW",+ "replyTo": "BIoC85lyFF",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 82mA (2/2)",+ "comment": "Finally, we thank the reviewer for identifying the relevant microscopy literature. We will discuss these works and more clearly distinguish their setting from ours. Cao et al. jointly estimate a dynamic scene and its motion from sequential raw measurements using a differentiable imaging forward model and per-dataset optimization, without pretraining. Kang et al. use neural fields to estimate optical aberrations and recover sample structure for adaptive-optics two-photon microscopy. Both methods explicitly solve physics-based inverse imaging problems using imaging forward models, whereas CD-RCM operates on already reconstructed RCM optical sections and performs amortized post-acquisition continuous-depth interpolation without attempting to alter the underlying imaging physics. Müller et al.’s multiresolution hash encoding is also a relevant alternative for coordinate-based representations, and we will include it in the discussion of possible depth encodings."+ },+ "createdAt": "2026-08-03T17:35:39.685Z",+ "modifiedAt": "2026-11-19T17:20:34.353Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=JBfoKjbmpW",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/jm24hot3ba.json added
+++ b/reviews/openreview/0waapzbygt/notes/jm24hot3ba.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jm24HOT3ba",+ "replyTo": "okLP1lwlOs",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer BUtu",+ "content": {+ "comment": "The authors have addressed my main concerns and provided helpful clarifications. I appreciate your careful engagement with the review process."+ },+ "createdAt": "2026-07-31T08:30:14.160Z",+ "modifiedAt": "2026-11-19T17:20:34.490Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=jm24HOT3ba",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/lgivps8cwc.json added
+++ b/reviews/openreview/0waapzbygt/notes/lgivps8cwc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "LgIVPS8cwc",+ "replyTo": "ojVdUrTS42",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "(1/2) Response to Meta Review by Area Chair 5XFb",+ "comment": "We thank the AC for synthesizing the reviews and highlighting gaps in the original evaluation, particularly the need for a clearer motivation and a more rigorous analysis of the benefits of our RCM-specific design relative to generic learning-based models. In response, we added modern learned baselines, audited potential train–evaluation overlap, and clarified the neural motivation and novel-view-synthesis framing.\n\n**1. Comparison with learned baselines**\n\nFollowing the reviewers’ recommendations, we evaluated two modern learned approaches: a NeRF-like per-stack coordinate MLP, and FILM (both zero-shot and fine-tuned on RCM data). We also added bilinear interpolation as an additional classical interpolation baseline.\n\n| Method | PSNR ↑ | SSIM ↑ | LPIPS ↓ | $\\mathcal{L}_{SPF}$ ↓ |\n|---|---:|---:|---:|---:|\n| NeRF-like coordinate MLP | 19.10 | 0.445 | 0.520 | 0.480 |\n| FILM, zero-shot | 20.24 | 0.380 | 0.440 | 0.156 |\n| FILM, fine-tuned | 22.83 | 0.510 | 0.496 | 0.181 |\n| Bilinear interpolation | 21.98 | 0.471 | 0.377 | 0.153 |\n| **CD-RCM** | **23.36** | **0.581** | **0.314** | **0.145** |\n\nThe NeRF-like model accurately fits the three observed input slices but underperforms every classical baseline at the held-out depths. Since it is optimized independently for each stack, it has no cross-stack anatomical prior with which to reconstruct unobserved microstructure.\n\nFine-tuning FILM substantially improves its PSNR and SSIM, but both perceptual metrics deteriorate relative to zero-shot inference. Qualitatively, zero-shot FILM produces sharp but discontinuous and morphologically implausible structures, whereas fine-tuning produces smoother predictions that improve photometric scores while suppressing high-frequency tissue detail. This behavior is similar to Gaussian interpolation, where smoothing improves PSNR and SSIM without producing corresponding faithful tissue structure.\n\nWe acknowledge that CD-RCM’s PSNR margin over Gaussian interpolation is modest. However, its advantage is consistent across all four metrics and is more pronounced for structural and perceptual fidelity, particularly SSIM and LPIPS. Together with the qualitative results and the existing loss ablations, these experiments indicate that the gains do not arise simply from using a larger learned model. Trivially adapting either a per-stack neural representation or a generic frame-interpolation network does not adequately solve continuous-depth RCM reconstruction. We will include the complete setup, quantitative comparisons, and qualitative analyses in the camera-ready version.\n\n**2. Split and potential data leakage**\n\nWe thank the AC for raising this important point. Since subject identifiers were not retained with the stacks, we cannot conclusively guarantee that different skin sites from the same volunteer did not appear in both the training and evaluation sets. We will revise the manuscript to state this limitation explicitly rather than describing the split as definitively subject-disjoint.\n\nTo investigate the more consequential possibility of duplicate, adjacent, or overlapping acquisitions of the same skin site across the split, we conducted a post hoc similarity audit using our skin-specific feature extractor from Section 3.4. We embedded the evaluation and training slices and computed the nearest-neighbor cosine similarity between each of the 60 evaluation stacks and the training set.\n\nOnly one evaluation stack exhibited an exceptionally high similarity of 0.98 to a training stack. Visual inspection showed nearly identical ring and cellular structures with a lateral shift, denoting readings from the same acquisition site. Seven additional evaluation stacks had nearest-neighbor similarities between 0.75 and 0.85; however, visual inspection found no corresponding anatomical structures, suggesting that these were feature-space false positives rather than overlapping acquisitions.\n\nWe then recomputed the aggregate evaluation after excluding these suspected overlapping stacks. Performance on the remaining 52 stacks was essentially unchanged, and the suspected similar stacks did not exhibit anomalously high reconstruction performance relative to the rest of the evaluation set. Thus, although the absence of subject identifiers prevents us from certifying a subject-disjoint split, the audit indicates that detectable near-duplicate or same-site overlap does not explain the reported gains. We will include this analysis and the corresponding qualitative results in the camera-ready version."+ },+ "createdAt": "2026-07-30T02:03:25.089Z",+ "modifiedAt": "2026-11-19T17:20:34.650Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=LgIVPS8cwc",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/ojvdurts42.json modified
+++ b/reviews/openreview/0waapzbygt/notes/ojvdurts42.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 5XFb","content": {- "metareview": "Reviewers appreciate the problem and call it underexplored. BWXy and BUtu credit the design for responding to the acquisition geometry of RCM rather than transplanting an existing method. Reviewer BUtu credits the in vivo dataset as a substantial effort in a modality with few public resources. All reviews rated clarity good or excellent. 82mA and BWXy single out the loss ablation as clean and convincing on its own terms.\n\nAcross reviews, the dominant objection is unanimous. All note that the paper compares only against classical, non-learned interpolation. All also would expect outperforming those baselines given that the proposed model is supervised and considerably more complex. No reviewer was able to determine whether the gains follow from the RCM-specific design or from the use of a large learned model. Reviewers BWXy and 82mA mention that the margin over the best classical method is comparable to the spread among the classical methods themselves, which sharpens the concern rather than resolving it. 82mA names specific learned comparators that would settle the question.\n\n82mA and BUtu also raise hallucination. The model synthesizes structure that was never observed. The paper describes the output as anatomically plausible without any clinician assessment, uncertainty analysis, or downstream evaluation that would distinguish faithful reconstruction from plausible-looking reconstruction. 82mA questions whether a neural approach is warranted at all given the modest gains, stating that adequate motivation would raise their score. BWXy asks a related question about why other generative models were not treated as applicable.\n\nIn addition, the paper states that subject-level metadata is unavailable. Splits are therefore performed at the level of individual stacks and are described as only effectively disjoint. Did stacks from the same subject appear on both sides? This would favour a learned method.\n\nThe response should at least\n* provide at least one strong learned baseline\n* address the split and leakage question above\n* give an explicit justification for the neural formulation and the view-synthesis framing.\n\n---\n\nThe rebuttal and discussion addressed several of the main concerns. The authors added a per-stack NeRF-like coordinate MLP, FILM in zero-shot and fine-tuned settings, and bilinear interpolation. CD-RCM performs best on the reported metrics. This provides evidence that the gains do not follow simply from using a learned model. Possible train–evaluation overlap was also investigated, with one likely same-site overlap and authors showed that the aggregate results remain essentially unchanged after excluding suspected overlaps. Because subject identifiers were not retained, a subject-disjoint split still cannot be guaranteed and should remain a stated limitation.\n\nReviewers BWXy and BUtu considered their main concerns addressed and moved their scores. Reviewer 82mA maintained a reject recommendation and raised concerns about the interpretation of the method in relation to optical resolution, the choice of Plücker embeddings, and missing related work. The authors subsequently clarified that the method increases axial sampling density within the existing optical resolution and does not claim recovery of information beyond the diffraction limit. They also agreed to narrow the corresponding claims and expand the discussion of alternative encodings and related microscopy methods. I consider the optical-resolution clarification adequate. The lack of an encoding ablation remains a secondary weakness.\n\nThe main unresolved concern is the faithfulness of synthesized intermediate slices. The method uses a learned prior to predict unobserved tissue structure, while the current evaluation is based on image-quality and perceptual metrics. The planned clinical-expert evaluation was not available during review, and the current dataset does not permit evaluation on the motivating downstream clinical tasks. This issue was raised in different forms across the reviews and remains important given the intended use of the reconstructed images.\n\nBalancing this, I recommend acceptance as a poster. The dominant objection in the preliminary meta-review was that the paper compared only against classical interpolation. This left open whether the gains came from the RCM-specific design or simply from using a learned model. The authors answered this directly. The two learned comparators added during rebuttal fail in informative ways: the per-stack coordinate MLP fits the observed slices but underperforms every classical baseline at held-out depths, having no cross-stack prior, while fine-tuned FILM improves photometric scores by smoothing away the high-frequency tissue detail that\nmatters here. That is evidence for the specific design rather than a generic capacity effect. The leakage question was investigated and the residual limitation is stated.\n\nI'm not following 82mA's recommendation, because the review's central objection was that the method implicitly claims recovery of structure below the diffraction limit. The authors clarified that the method increases axial sampling density within the existing optical resolution and makes no such claim. Authors also agreed to narrow the corresponding text. The clarification was adequate and with the\nclaims narrowed the objection largely goes away. 82mA's final justification reproduces their earlier comment verbatim and therefore predates the clarification, so it didn't engage with the response. The two remaining points (absence of an encoding ablation, missing microscopy deconvolution literature) are legitimate but addressable in the camera-ready.\n\nThe faithfulness of synthesized intermediate slices remains an open question. I am treating it as a camera-ready condition, because the contribution is use-inspired and the paper's claims are now scoped to increased axial sampling rather than to diagnostic sufficiency. \n\nFor the camera-ready I'd expect:\n* the completed clinician assessment the authors committed to\n* an explicit statement of what the method can and cannot recover, placed such that a reader sees it rather than in a limitations paragraph\n* the encoding ablation\n* the missing related work\n* the split limitation retained in the text (not softened).\n\nReviewers BWXy and BUtu both moved to the accept range on the strength of the rebuttal. BWXy's remaining reservation concerns evidence the current dataset cannot supply rather than a defect in the work."+ "metareview": "Reviewers appreciate the problem and call it underexplored. BWXy and BUtu credit the design for responding to the acquisition geometry of RCM rather than transplanting an existing method. Reviewer BUtu credits the in vivo dataset as a substantial effort in a modality with few public resources. All reviews rated clarity good or excellent. 82mA and BWXy single out the loss ablation as clean and convincing on its own terms.\n\nAcross reviews, the dominant objection is unanimous. All note that the paper compares only against classical, non-learned interpolation. All also would expect outperforming those baselines given that the proposed model is supervised and considerably more complex. No reviewer was able to determine whether the gains follow from the RCM-specific design or from the use of a large learned model. Reviewers BWXy and 82mA mention that the margin over the best classical method is comparable to the spread among the classical methods themselves, which sharpens the concern rather than resolving it. 82mA names specific learned comparators that would settle the question.\n\n82mA and BUtu also raise hallucination. The model synthesizes structure that was never observed. The paper describes the output as anatomically plausible without any clinician assessment, uncertainty analysis, or downstream evaluation that would distinguish faithful reconstruction from plausible-looking reconstruction. 82mA questions whether a neural approach is warranted at all given the modest gains, stating that adequate motivation would raise their score. BWXy asks a related question about why other generative models were not treated as applicable.\n\nIn addition, the paper states that subject-level metadata is unavailable. Splits are therefore performed at the level of individual stacks and are described as only effectively disjoint. Did stacks from the same subject appear on both sides? This would favour a learned method.\n\nThe response should at least\n* provide at least one strong learned baseline\n* address the split and leakage question above\n* give an explicit justification for the neural formulation and the view-synthesis framing.\n\n---\n\nThe rebuttal and discussion addressed several of the main concerns. The authors added a per-stack NeRF-like coordinate MLP, FILM in zero-shot and fine-tuned settings, and bilinear interpolation. CD-RCM performs best on the reported metrics. This provides evidence that the gains do not follow simply from using a learned model. Possible train–evaluation overlap was also investigated, with one likely same-site overlap and authors showed that the aggregate results remain essentially unchanged after excluding suspected overlaps. Because subject identifiers were not retained, a subject-disjoint split still cannot be guaranteed and should remain a stated limitation.\n\nReviewers BWXy and BUtu considered their main concerns addressed and moved their scores. Reviewer 82mA maintained a reject recommendation and raised concerns about the interpretation of the method in relation to optical resolution, the choice of Plücker embeddings, and missing related work. The authors subsequently clarified that the method increases axial sampling density within the existing optical resolution and does not claim recovery of information beyond the diffraction limit. They also agreed to narrow the corresponding claims and expand the discussion of alternative encodings and related microscopy methods. I consider the optical-resolution clarification adequate. The lack of an encoding ablation remains a secondary weakness.\n\nThe main unresolved concern is the faithfulness of synthesized intermediate slices. The method uses a learned prior to predict unobserved tissue structure, while the current evaluation is based on image-quality and perceptual metrics. The planned clinical-expert evaluation was not available during review, and the current dataset does not permit evaluation on the motivating downstream clinical tasks. This issue was raised in different forms across the reviews and remains important given the intended use of the reconstructed images.\n\nBalancing this, I recommend acceptance as a poster. The dominant objection in the preliminary meta-review was that the paper compared only against classical interpolation. This left open whether the gains came from the RCM-specific design or simply from using a learned model. The authors answered this directly. The two learned comparators added during rebuttal fail in informative ways: the per-stack coordinate MLP fits the observed slices but underperforms every classical baseline at held-out depths, having no cross-stack prior, while fine-tuned FILM improves photometric scores by smoothing away the high-frequency tissue detail that\nmatters here. That is evidence for the specific design rather than a generic capacity effect. The leakage question was investigated and the residual limitation is stated.\n\nI'm not following 82mA's recommendation, because the review's central objection was that the method implicitly claims recovery of structure below the diffraction limit. The authors clarified that the method increases axial sampling density within the existing optical resolution and makes no such claim. Authors also agreed to narrow the corresponding text. The clarification was adequate and with the\nclaims narrowed the objection largely goes away. 82mA's final justification reproduces their earlier comment verbatim and therefore predates the clarification, so it didn't engage with the response. The two remaining points (absence of an encoding ablation, missing microscopy deconvolution literature) are legitimate but addressable in the camera-ready.\n\nThe faithfulness of synthesized intermediate slices remains an open question. I am treating it as a camera-ready condition, because the contribution is use-inspired and the paper's claims are now scoped to increased axial sampling rather than to diagnostic sufficiency. \n\nFor the camera-ready I'd expect:\n* the completed clinician assessment the authors committed to\n* an explicit statement of what the method can and cannot recover, placed such that a reader sees it rather than in a limitations paragraph\n* the encoding ablation\n* the missing related work\n* the split limitation retained in the text (not softened).\n\nReviewers BWXy and BUtu both moved to the accept range on the strength of the rebuttal. BWXy's remaining reservation concerns evidence the current dataset cannot supply rather than a defect in the work.",+ "final_justification": "Accept (poster).\n\nI changed my recommendation from Reject after weighing the rebuttal and the full discussion. The concern in the preliminary meta-review was answered. The authors added a per-stack NeRF-like coordinate MLP, FILM in zero-shot and fine-tuned settings, and bilinear interpolation, with CD-RCM performing best across the reported metrics, and the two learned comparators failing in ways that support rather than undercut the RCM-specific design. Possible train-evaluation overlap was audited directly: one likely same-site overlap was identified and aggregate results were essentially unchanged once suspected overlaps were excluded. Because subject identifiers were not retained, a subject-disjoint split cannot be guaranteed, and that limitation must remain stated in the paper.\n\nReviewers BWXy and BUtu considered their main concerns addressed and moved into the accept range. 82mA maintained a recommendation to reject because the method implicitly claims recovery of structure beyond the optical resolution limit. The authors clarified that it increases axial sampling density within the existing resolution and claims nothing beyond the diffraction limit, and undertook to narrow the corresponding claims. I consider that clarification adequate. Reviewer 82mA's final justification reproduces their earlier comment verbatim and predates this clarification, so it does not engage the response that addresses its central point. Their remaining observations (no encoding ablation, missing related work on neural representations for microscopy) are addressable in a revision.\n\nThe open question is the faithfulness of synthesized intermediate slices. The planned clinician evaluation was not completed within the review period. The present dataset cannot exercise the motivating downstream clinical task. I am treating this as a camera-ready condition rather than a reason to reject, given that the contribution is use-inspired and the claims are now scoped to increased axial sampling rather than diagnostic sufficiency.\n\nThe camera-ready should include the completed clinician assessment, an explicit statement of what the method can and cannot recover, the encoding ablation, the missing related work, and the retained split limitation.\n\nThe authors submitted one confidential comment noting that the super-resolution and depth-encoding criticisms were raised late in the discussion period, limiting their opportunity to respond fully. I accept that point. The timing was genuinely unfavorable and informed my decision to treat their clarification on the optical-resolution question as adequate rather than holding a compressed response window against them. The comment did not otherwise affect the recommendation."},"createdAt": "2026-07-22T19:38:19.018Z",- "modifiedAt": "2026-11-18T15:18:10.378Z",+ "modifiedAt": "2026-11-19T04:58:57.675Z","url": "https://openreview.net/forum?id=0WaapzByGt¬eId=ojVdUrTS42","license": "CC-BY-4.0"}
reviews/openreview/0waapzbygt/notes/qtntlefjpm.json added
+++ b/reviews/openreview/0waapzbygt/notes/qtntlefjpm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "qtNTleFjPm",+ "replyTo": "jm24HOT3ba",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the thoughtful review and for engaging with our rebuttal. We are glad the additional experiments addressed your concerns, and we appreciate the score increase."+ },+ "createdAt": "2026-08-01T22:28:41.582Z",+ "modifiedAt": "2026-11-19T17:20:34.316Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=qtNTleFjPm",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/qwck1zuaor.json added
+++ b/reviews/openreview/0waapzbygt/notes/qwck1zuaor.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QwCK1zUAoR",+ "replyTo": "eJZcuwmDBX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your thoughtful feedback and for engaging with our rebuttal. We are glad the additional experiments addressed your concerns, and we sincerely appreciate the score increase."+ },+ "createdAt": "2026-08-03T17:42:46.189Z",+ "modifiedAt": "2026-11-19T17:20:34.128Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=QwCK1zUAoR",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/ralsxrac5q.json added
+++ b/reviews/openreview/0waapzbygt/notes/ralsxrac5q.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "RaLSxrac5Q",+ "replyTo": "olxu5xXEBX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer BWXy,\n\nThank you for your valuable comments and constructive feedback.\n\nAs the discussion period approaches its end, we would like to kindly ask whether our responses have sufficiently addressed your concerns and questions. Please feel free to let us know if any further clarifications, explanations, or experiments are needed. We are more than happy to elaborate.\n\nMany thanks for all your time and efforts. We truly appreciate it.\n\nThe Authors"+ },+ "createdAt": "2026-08-01T22:29:29.058Z",+ "modifiedAt": "2026-11-19T17:20:34.304Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=RaLSxrac5Q",+ "license": "CC-BY-4.0"+}
reviews/openreview/0waapzbygt/notes/vzkazjmdr2.json added
+++ b/reviews/openreview/0waapzbygt/notes/vzkazjmdr2.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "VzkaZJMdr2",+ "replyTo": "LgIVPS8cwc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "(2/2) Response to Meta Review by Area Chair 5XFb",+ "comment": "**3. Motivation for the neural formulation and view-synthesis framing**\n\nOur objective is not simply to produce visually smooth transitions between adjacent slices. RCM sections capture a three-dimensional tissue volume in which cellular structures emerge, disappear, divide, merge, and change contrast nonlinearly with depth. Classical interpolation treats each pixel independently and assumes smooth axial intensity variation. It cannot use any surrounding anatomical context or learn how RCM morphology typically evolves across depth.\n\nA neural formulation allows CD-RCM to learn a cross-stack prior over depth-dependent tissue structure. This is especially relevant because the finite axial point-spread function causes neighboring optical sections to contain partially overlapping information, making intermediate reconstruction possible but inherently ill-posed. The model does not guarantee that every synthesized structure is biologically correct; rather, it provides a mechanism for exploiting population-level anatomical and textural regularities that pixel-wise interpolation and per-stack optimization lack.\n\nThe view-synthesis framing follows from the continuous specification of the desired output. Given sparse en-face observations and a queried axial position (z), CD-RCM synthesizes the optical section associated with that previously unobserved depth. Unlike conventional video interpolation, the target is not restricted to a fixed temporal offset. Unlike standard NeRF, RCM has negligible lateral parallax and observes internal tissue through systematic axial optical sectioning.\n\nCD-RCM therefore leverages the structured axial acquisition process of optical sectioning microscopy and represents depth as a continuous, queryable dimension through the estimated virtual camera parameters. It is supervised using discretely acquired slices, but no ground truth exists at every arbitrary sub-slice depth queried during inference. This formulation allows synthesis at non-integer, previously unseen depths instead of restricting the model to offsets explicitly encountered during training.\n\nThe limited size of the available RCM dataset also influenced this design. More data-intensive generative approaches risk overfitting or hallucinating structures in this setting. Our feedforward, depth-conditioned approach learns a cross-stack prior while remaining practical in the available limited-data regime and provides arbitrary-depth generalization without per-stack optimization. Furthermore, its computational cost is amortized across cases, as at inference, 10x densification of a complete stack requires approximately 0.8 seconds on one A6000 GPU.\n\n**4. Hallucination and biological validity**\n\nWe agree that synthesized slices must not be equated with directly observed tissue or described as biologically valid without appropriate expert assessment. The author team has worked with RCM imaging for approximately two decades, and one co-author pioneered its clinical application. Their initial qualitative inspection of the reconstructed stacks did not identify obvious hallucinations or reconstruction artifacts. However, as the reviewers correctly emphasized, informal inspection by the authors is not a substitute for a systematic, blinded clinical evaluation.\n\nWe are therefore conducting a more rigorous assessment with clinical RCM experts, as described in our rebuttal to Reviewer 82mA (point C). This evaluation will examine the fidelity of the generated views, identify hallucinated or anatomically inconsistent structures, compare clinician preferences across interpolation methods, and assess utility for Dermal-Epidermal Junction localization. Note that DEJ is an important feature to localize in skin cancer diagnosis, as this is where skin cancer originates. \n\nOverall, the primary goal of this paper is to demonstrate that continuous-depth RCM reconstruction can be formulated as a novel-view synthesis problem and to provide initial evidence that this direction is technically viable. Establishing this feasibility is a necessary first step before undertaking larger studies involving pathological tissue, more diverse populations, multiple devices and institutions, and task-specific clinical annotations, which remain necessary future work."+ },+ "createdAt": "2026-07-30T02:03:47.474Z",+ "modifiedAt": "2026-11-19T17:20:34.524Z",+ "url": "https://openreview.net/forum?id=0WaapzByGt¬eId=VzkaZJMdr2",+ "license": "CC-BY-4.0"+}