potentialpaper

CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy

Import NeurIPS 2026 submission 0WaapzByGt: 8 notes

@openreview[bot] · 2026-11-22 17:53 UTC · 940237a1e1cb

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,24 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "0WaapzByGt"
+ }
+ ],
+ "title": "CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy",
+ "authors": [
+ "Tooba Imtiaz",
+ "Milind Rajadhyaksha",
+ "Kivanc Kose",
+ "Jennifer Dy"
+ ],
+ "abstract": "Reflectance confocal microscopy (RCM) provides noninvasive, cellular-resolution “optical biopsies” of human skin {\\em in vivo} by acquiring en-face images at successive depths, forming a sparse $z$-stack. Due to optical limitations, these stacks are anisotropic 3D volumes with lateral resolution ($0.5\\mu m$) $\\sim$6 times higher compared to axial resolution, which is defined by the optical sectioning ($3\\mu m$), limiting the interpretation of tissue. Our goal is to provide continuous-depth visualization by interpolating intermediate sections and making the 3D volume isotropic. Such a representation permits arbitrary-direction sectioning, including histopathology-like cross-sectional examination, without requiring per-patient optimization. To that end, we introduce the first RCM-specific novel-view synthesis (NVS) approach CD-RCM: a feedforward model that predicts realistic, unseen depths from sparsely sampled RCM stacks. Classical neural rendering methods focus on reconstruction from surface-level multi-view observations. In contrast to surface-level camera views, RCM can acquire optically sectioned en-face images of tissue beyond the surface up to $200 \\mu m$. However, during visualization of the RCM stacks, observations of the shallower sections (towards the surface) obscure the deeper ones. This unique axial imaging geometry and layer-dependent anatomical organization motivated our development of a tailored architectural and training framework that explicitly accounts for RCM’s depth-resolved, occlusive imaging physics. Experiments demonstrate that CD-RCM achieves high-fidelity novel-view synthesis with sub-second inference time.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/0waapzbygt/forms.json added

+++ b/reviews/openreview/0waapzbygt/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/fxf3ybuqcx.json added

+++ b/reviews/openreview/0waapzbygt/notes/fxf3ybuqcx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "fxf3YbUQcX",
+ "replyTo": "L2cDRNzN9Q",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for their constructive comments, for describing CD-RCM as ‘technically sound’ and for appreciating the ablation experiments. Below, we address their feedback and questions:\n\n\n **A. Could the authors further motivate the need to perform this interpolation using a neural network? Clarifying this motivation for the reader would help justify the expense of using a neural network for this interpolation scheme and also establish this as a new neural view synthesis problem for the community.**\n\nWe thank the reviewer for this note. Our goal is not simply to produce *visually* smooth transitions between adjacent RCM slices to make the 3D volume isotropic. Each slice captures a different optical section of a three-dimensional tissue volume, in which cellular structures can emerge, disappear, divide, merge, or change contrast nonlinearly with depth. Classical interpolation methods operate independently at each pixel and assume that intensity varies smoothly along the axial direction. They therefore cannot use anatomical context or learn how tissue morphology typically evolves across depth. This limitation is especially important in RCM because each optical section contains partially overlapping information from adjacent depths due to the finite axial point-spread function, making reconstruction possible but inherently ill-posed.\n\nA neural model is useful because it can learn a cross-stack prior over depth-dependent RCM morphology from the training data. Rather than relying only on the intensities of the available slices, CD-RCM uses patterns learned across many independent stacks to infer intermediate structures that are consistent with the surrounding observations. We do not argue that a neural model guarantees anatomically correct reconstruction; synthesized slices remain predictions and must be interpreted accordingly. Rather, the neural formulation provides a mechanism for exploiting population-level anatomical and textural regularities that pixel-wise interpolation and per-stack photometric optimization fundamentally lack.\n\nThe view-synthesis framing follows from the fact that the desired output is specified by a continuous axial imaging coordinate. Given sparse en-face observations and a queried depth (z), the model synthesizes the optical section associated with that previously unobserved depth. This differs from conventional video-frame interpolation, which typically predicts fixed temporal positions between two frames, and from standard NeRF-style synthesis, which relies on lateral viewpoint changes and geometric parallax. RCM instead provides aligned internal tissue sections acquired through systematic axial translation, motivating a specialized form of depth-conditioned neural view synthesis.\n\nThe computational cost is also amortized across cases, as CD-RCM is trained once and then predicts arbitrary intermediate depths in a single feedforward pass, without per-stack optimization. In our experiments, tenfold densification of a complete stack takes approximately 0.8 seconds on one A6000 GPU. The additional NeRF-like and FILM experiments (presented below) further support this motivation, and prove that neither a per-stack coordinate MLP nor a generic learned frame-interpolation model adequately reconstructs RCM morphology. These results show that the gains do not come from applying an arbitrary neural network, but from our RCM-specific formulation, which leverages the structured axial acquisition process of optical sectioning microscopy, models depth variation as a queryable dimension, and learns a cross-stack prior over depth-dependent tissue morphology.\n\n\n**B. Compare against neural interpolation approaches (namely NeRF and FILM) and bilinear interpolation**\n\nFollowing the reviewer’s recommendation, we evaluate two neural interpolation methods, namely NeRF and FILM, on RCM data.\n\n1. *NeRF-like method, setup and evaluation*: RCM's virtual camera (paper Sec 3.2) is a pure z-translation with zero lateral parallax, so each observed pixel at depth z is a *direct* observation of the reflectance field at (x,y,z) and not a ray-integral through occluding volume like NeRF. Therefore, the most faithful and simplest per-scene coordinate-MLP analog is: fit `f(x,y,z) -> intensity` (positional encoding + small MLP) via photometric loss only on the 3 known input slices per stack, with no cross-stack learned prior at all (which is by design of NeRF), then query at the 4 held-out target depths.\n\n| PSNR↑ | SSIM↑ | LPIPS↓ | $\\mathcal{L}_{SPF}$↓ |\n|---|---|---|---|\n| 19.10 | 0.445 | 0.520 | 0.480 |\n\nThis loses to every classical interpolation baseline (best classical, Gaussian: 22.87 PSNR / 0.522 SSIM), and the L_SPF gap is especially large (0.48 vs ~0.14-0.16 for CD-RCM/classical methods). The per-scene fit reproduces the 3 known slices well (judging by the train PSNR), but has no anatomical priors to extrapolate plausible *unobserved* microstructure at intermediate depths. This result reinforces our motivation for not resorting to per-stack photometric optimization methods for this task, as it is the wrong tool with no capacity for a cross-stack learned prior.\n\n2. *FILM setup and evaluation:* We evaluate FILM under two settings:\n\n a. zero-shot evaluation: We use the pretrained checkpoint to interpolate RCM slices between known RCM slices. Because FILM takes two endpoint frames as input, we construct subsequences of five consecutive RCM slices, consistent with the smallest spacing between conditioning slices in our experiments (Section 3.6). We use the boundary slices as the 2 inputs and predict the intermediate 3 slices.\n\n b. finetuning FILM on RCM data: We finetune FILM for five epochs using the same five-slice subsequences. For a controlled comparison, we use the same training objective as CD-RCM, combining MSE, LPIPS, and the skin-specific perceptual feature loss defined in Eq. 8.\n\n| |PSNR↑ | SSIM↑ | LPIPS↓ | $\\mathcal{L}_{SPF}$↓ |\n|---|---|---|---|---|\n| zero-shot (pretrained) | 20.24 | 0.380 | 0.440 | 0.156 |\n| **fine-tuned**, 5 epochs | 22.83 | 0.510 | 0.496 | 0.181 |\n\nWhile finetuning appreciably improves photometric accuracy (PSNR and SSIM), performance on both perceptual metrics worsens compared to zero-shot evaluation.\n\nThe qualitative results help explain this discrepancy. Zero-shot FILM produces relatively sharp predictions but introduces severe inter-slice discontinuities and spurious, morphologically implausible structures. After fine-tuning, the predictions become smoother, improving PSNR and SSIM but suppressing high-frequency morphological detail and worsening perceptual similarity. This behavior is similar to Gaussian interpolation, for which the smoothing misleadingly improves photometric scores without producing corresponding faithful tissue structure.\n\n**Bilinear Interpolation:** The quantitative results are:\n\n| PSNR↑ | SSIM↑ | LPIPS↓ | $\\mathcal{L}_{SPF}$↓ |\n|---|---|---|---|\n| 21.98 | 0.471 | 0.377 | 0.153 |\n\nThe performance is similar to B-Spline Interpolation, with lower photometric scores but higher perceptual scores than other classical interpolators.\n\nWe thank the reviewer for suggesting these baselines and will include all results and analyses in the camera-ready version.\n\n**C. Could the authors clarify whether clinical practitioners prefer the presented method of interpolation when viewing skin data? This might require additional user study, but I believe this would be beneficial to readers trying to understand the motivation of the work.**\n\nWe thank the reviewer for highlighting this. We have access to clinical experts who can help us evaluate 1) the quality and fidelity of generated views, 2) evaluate if the generated views contain diagnostically relevant features, and 3) highlight any hallucinations. This would include blinded trials to measure preference between interpolation methods, evaluate the anatomical correctness of generated novel views, as well as their significance for the downstream clinical task of DEJ localization. We aim to complete this study in time to include it in the camera-ready version.\n\n**D. Authors do not address other limitations such as interpolation speed when using a neural network instead of more traditional interpolation schemes.**\n\nAs reported in the paper, obtaining 10x densification of a full RCM stack takes 0.8 seconds. This is a fixed one-time cost per stack, rather than a recurring per-query expense, and it is fast enough to give clinical experts near-instant access to dense reconstructions at bedside time. Reviewers BWXy and BUtu also appreciate the subsecond inference time and its utility for interactive imaging. As reiterated by reviewer BUtu, this also motivates why an optimization-based neural rendering approach is not feasible for this use-case, since not only does a per-stack optimizer lack anatomical priors, but the computational cost and wall-clock time needed to optimize such representations per stack cannot meet the needs of bedside time evaluation by clinicians. \nWe thank the reviewer for this note, and for completeness, we will include the wall-clock times for all baseline interpolation methods.\n\n**E. The text has been LLM-written, but it appears to only have been used for cleaning up the text. This does not affect my score.**\n\nNo section of the paper has been LLM-written beyond sentence-level edits and reviewing grammatical correctness, as declared in the checklist. We carefully curated all the related literature, developed and evaluated our proposed approach, designed the figures and wrote the manuscript over several months."
+ },
+ "createdAt": "2026-07-28T02:23:35.510Z",
+ "modifiedAt": "2026-11-18T17:10:32.889Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=fxf3YbUQcX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/fz8f3pi1hc.json added

+++ b/reviews/openreview/0waapzbygt/notes/fz8f3pi1hc.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "Fz8f3pi1HC",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "Reviewers appreciate the problem and call it underexplored. BWXy and BUtu credit the design for responding to the acquisition geometry of RCM rather than transplanting an existing method. Reviewer BUtu credits the in vivo dataset as a substantial effort in a modality with few public resources. All reviews rated clarity good or excellent. 82mA and BWXy single out the loss ablation as clean and convincing on its own terms.\n\nAcross reviews, the dominant objection is unanimous. All note that the paper compares only against classical, non-learned interpolation. All also would expect outperforming those baselines given that the proposed model is supervised and considerably more complex. No reviewer was able to determine whether the gains follow from the RCM-specific design or from the use of a large learned model. Reviewers BWXy and 82mA mention that the margin over the best classical method is comparable to the spread among the classical methods themselves, which sharpens the concern rather than resolving it. 82mA names specific learned comparators that would settle the question.\n\n82mA and BUtu also raise hallucination. The model synthesizes structure that was never observed. The paper describes the output as anatomically plausible without any clinician assessment, uncertainty analysis, or downstream evaluation that would distinguish faithful reconstruction from plausible-looking reconstruction. 82mA questions whether a neural approach is warranted at all given the modest gains, stating that adequate motivation would raise their score. BWXy asks a related question about why other generative models were not treated as applicable.\n\nIn addition, the paper states that subject-level metadata is unavailable. Splits are therefore performed at the level of individual stacks and are described as only effectively disjoint. Did stacks from the same subject appear on both sides? This would favour a learned method.\n\nThe response should at least\n* provide at least one strong learned baseline\n* address the split and leakage question above\n* give an explicit justification for the neural formulation and the view-synthesis framing.\n\n---\n\nThe rebuttal and discussion addressed several of the main concerns. The authors added a per-stack NeRF-like coordinate MLP, FILM in zero-shot and fine-tuned settings, and bilinear interpolation. CD-RCM performs best on the reported metrics. This provides evidence that the gains do not follow simply from using a learned model. Possible train–evaluation overlap was also investigated, with one likely same-site overlap and authors showed that the aggregate results remain essentially unchanged after excluding suspected overlaps. Because subject identifiers were not retained, a subject-disjoint split still cannot be guaranteed and should remain a stated limitation.\n\nReviewers BWXy and BUtu considered their main concerns addressed and moved their scores. Reviewer 82mA maintained a reject recommendation and raised concerns about the interpretation of the method in relation to optical resolution, the choice of Plücker embeddings, and missing related work. The authors subsequently clarified that the method increases axial sampling density within the existing optical resolution and does not claim recovery of information beyond the diffraction limit. They also agreed to narrow the corresponding claims and expand the discussion of alternative encodings and related microscopy methods. I consider the optical-resolution clarification adequate. The lack of an encoding ablation remains a secondary weakness.\n\nThe main unresolved concern is the faithfulness of synthesized intermediate slices. The method uses a learned prior to predict unobserved tissue structure, while the current evaluation is based on image-quality and perceptual metrics. The planned clinical-expert evaluation was not available during review, and the current dataset does not permit evaluation on the motivating downstream clinical tasks. This issue was raised in different forms across the reviews and remains important given the intended use of the reconstructed images.\n\nBalancing this, I recommend acceptance as a poster. The dominant objection in the preliminary meta-review was that the paper compared only against classical interpolation. This left open whether the gains came from the RCM-specific design or simply from using a learned model. The authors answered this directly. The two learned comparators added during rebuttal fail in informative ways: the per-stack coordinate MLP fits the observed slices but underperforms every classical baseline at held-out depths, having no cross-stack prior, while fine-tuned FILM improves photometric scores by smoothing away the high-frequency tissue detail that\nmatters here. That is evidence for the specific design rather than a generic capacity effect. The leakage question was investigated and the residual limitation is stated.\n\nI'm not following 82mA's recommendation, because the review's central objection was that the method implicitly claims recovery of structure below the diffraction limit. The authors clarified that the method increases axial sampling density within the existing optical resolution and makes no such claim. Authors also agreed to narrow the corresponding text. The clarification was adequate and with the\nclaims narrowed the objection largely goes away. 82mA's final justification reproduces their earlier comment verbatim and therefore predates the clarification, so it didn't engage with the response. The two remaining points (absence of an encoding ablation, missing microscopy deconvolution literature) are legitimate but addressable in the camera-ready.\n\nThe faithfulness of synthesized intermediate slices remains an open question. I am treating it as a camera-ready condition, because the contribution is use-inspired and the paper's claims are now scoped to increased axial sampling rather than to diagnostic sufficiency. \n\nFor the camera-ready I'd expect:\n* the completed clinician assessment the authors committed to\n* an explicit statement of what the method can and cannot recover, placed such that a reader sees it rather than in a limitations paragraph\n* the encoding ablation\n* the missing related work\n* the split limitation retained in the text (not softened).\n\nReviewers BWXy and BUtu both moved to the accept range on the strength of the rebuttal. BWXy's remaining reservation concerns evidence the current dataset cannot supply rather than a defect in the work.",
+ "final_justification": "Accept (poster).\n\nI changed my recommendation from Reject after weighing the rebuttal and the full discussion. The concern in the preliminary meta-review was answered. The authors added a per-stack NeRF-like coordinate MLP, FILM in zero-shot and fine-tuned settings, and bilinear interpolation, with CD-RCM performing best across the reported metrics, and the two learned comparators failing in ways that support rather than undercut the RCM-specific design. Possible train-evaluation overlap was audited directly: one likely same-site overlap was identified and aggregate results were essentially unchanged once suspected overlaps were excluded. Because subject identifiers were not retained, a subject-disjoint split cannot be guaranteed, and that limitation must remain stated in the paper.\n\nReviewers BWXy and BUtu considered their main concerns addressed and moved into the accept range. 82mA maintained a recommendation to reject because the method implicitly claims recovery of structure beyond the optical resolution limit. The authors clarified that it increases axial sampling density within the existing resolution and claims nothing beyond the diffraction limit, and undertook to narrow the corresponding claims. I consider that clarification adequate. Reviewer 82mA's final justification reproduces their earlier comment verbatim and predates this clarification, so it does not engage the response that addresses its central point. Their remaining observations (no encoding ablation, missing related work on neural representations for microscopy) are addressable in a revision.\n\nThe open question is the faithfulness of synthesized intermediate slices. The planned clinician evaluation was not completed within the review period. The present dataset cannot exercise the motivating downstream clinical task. I am treating this as a camera-ready condition rather than a reason to reject, given that the contribution is use-inspired and the claims are now scoped to increased axial sampling rather than diagnostic sufficiency.\n\nThe camera-ready should include the completed clinician assessment, an explicit statement of what the method can and cannot recover, the encoding ablation, the missing related work, and the retained split limitation.\n\nThe authors submitted one confidential comment noting that the super-resolution and depth-encoding criticisms were raised late in the discussion period, limiting their opportunity to respond fully. I accept that point. The timing was genuinely unfavorable and informed my decision to treat their clarification on the optical-resolution question as adequate rather than holding a compressed response window against them. The comment did not otherwise affect the recommendation."
+ },
+ "createdAt": "2026-09-24T11:15:58.446Z",
+ "modifiedAt": "2026-11-18T14:52:10.794Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=Fz8f3pi1HC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/l2cdrnzn9q.json added

+++ b/reviews/openreview/0waapzbygt/notes/l2cdrnzn9q.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "L2cDRNzN9Q",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 82mA",
+ "content": {
+ "summary": "Reflectance confocal microscopy (RCM) is a non-invasive method for examining human skin without collecting biopsies by scanning the focus of a confocal microscope through successive depths of human skin tissue. Because of the optical resolution limit, the resulting image volume is anisotropic, with greater resolution in x-y than in z. For visualization purposes, it is useful to interpolate this volume to display isotropically. The authors apply a neural rendering-inspired approach (as in Neural Radiance Fields or NeRFs) to perform this interpolation. This frames the problem of interpolating between acquired planes as a view synthesis problem. The authors train a Transformer decoder to perform this interpolation with a new perceptual loss tuned to human skin images via low-rank fine tuning of a DINOv3 model. The resulting network outperforms traditional interpolation methods such as cubic spline interpolation.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "The work appears technically sound, but proper comparisons and clear motivation for this application are missing.\nNote: the text has been LLM-written, but it appears to only have been used for cleaning up the text. This does not affect my score.\n\n### Strengths\nThe method as presented does beat the standard interpolation baselines presented, which are not learned methods and do not take advantage of any priors of human skin images.\n\nThe authors also nicely ablate their proposed loss function to demonstrate that the addition does also slightly improve image similarity metrics.\n\n### Weaknesses\n1. The work presented achieves only a slight increase in accuracy over more traditional interpolation schemes, but it is not clear how desirable such an increase based on a neural network is, especially due to the possibility for hallucinations or artifacts due to the neural network. These artifacts may be especially undesirable in a clinical setting. The work does not seem well motivated.\n\n2. The authors also miss other work in neural networks for interpolation (see Questions) which should be engaged with or at least discussed for a fair comparison. It is also not clear how useful the framing of this problem in the context of “view synthesis” rather than interpolation is, especially given that comparisons are not made against other neural view synthesis approaches either. Including these comparisons would increase the usefulness of this paper for readers interested in this application.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 1,
+ "originality": 2,
+ "questions": "1. Could the authors further motivate the need to perform this interpolation using a neural network? Clarifying this motivation for the reader would help justify the expense of using a neural network for this interpolation scheme and also establish this as a new neural view synthesis problem for the community. Currently this motivation is lacking. I would increase my score with a sufficient motivation for this approach.\n\n2. Why are there no comparisons to other deep learning-based view synthesis methods beyond three standard interpolation methods? Further, why are there no comparisons to even more standard interpolation methods such as bilinear interpolation? Establishing more baseline comparisons would help highlight how this method compares for readers interested in this application. Relevant comparisons would include per-stack optimization using a NeRF-like approach (Mildenhall et al., ECCV 2020) or video frame interpolation networks such as FILM (Reda et al., “FILM: Frame Interpolation for Large Motion”, ECCV 2022). Frame interpolation networks have also been shown to be useful in interpolating planes of 3D image volumes (Gambini et al., “Video frame interpolation neural network for 3D tomography across different length scales”, Nat. Comms. 2024). This literature is not sufficiently discussed in the manuscript.\n\n3. Could the authors clarify whether clinical practitioners prefer the presented method of interpolation when viewing skin data? This might require additional user study, but I believe this would be beneficial to readers trying to understand the motivation of the work. I would increase my score if such a user study were included or discussed.",
+ "limitations": "The authors discuss limitations in their registration approach as well as their data filtering, but do not address other limitations such as interpolation speed when using a neural network instead of more traditional interpolation schemes. Including other metrics of comparison beyond image similarity would be useful for readers interested in this application.\n\nThe authors also do not discuss the possibility for neural networks to introduce hallucinated artifacts in images, which may not be desirable in clinical settings.",
+ "rating": 2,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I am copying my final justification as discussed with the authors below:\n\nI still take issue with the framing or motivation of the work. I avoided discussion of resolution in my original review because the work was explicitly framed as being about visualization, but if the goal is \"not simply to produce visually smooth transitions\" between slices but really to increase the resolvable features, then this discussion is unavoidable but missing from the work. The fact that different cellular structures have complicated spatial distributions across depth is something that no interpolation or view synthesis can resolve better than the diffraction limit. In this case, the goal is really to perform super-resolution. The method as presented would only be able to perform this super-resolution due to the structural priors learned by the model across the training data of various tissue samples (assuming all the data is from exactly the same microscope with the same point spread function). But that data itself is still diffraction limited by the point spread function, and there is no physical strategy to break the diffraction limit (e.g. structured illumination). So it is not clear in what way the method is not just about learning smooth transitions between diffraction limited planes.\n\nFurther, it is possible that this architecture combining Transformers and Plücker embeddings is a good approach for performing this kind of super-resolution on this particular modality, but then there are also no discussions or experiments regarding why this particular embedding is better than others (e.g. random, position encoding, some kind of learnable encodings (\"Instant neural graphics primitives with a multiresolution hash encoding\", Müller et al. SIGGRAPH 2022), etc.) or references to other relevant work using microscopy and neural representations for deconvolution, e.g. \"Neural space–time model for dynamic multi-shot imaging\", Cao et al. Nature Methods 2024 or \"Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields\", Kang et al. Nature Methods 2026 (though these works optimize per-sample neural representations rather than the amortized approach taken here).\n\nFor this reason, I will maintain my score."
+ },
+ "createdAt": "2026-06-26T03:46:02.763Z",
+ "modifiedAt": "2026-11-18T13:34:47.844Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=L2cDRNzN9Q",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/ojvdurts42.json added

+++ b/reviews/openreview/0waapzbygt/notes/ojvdurts42.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ojVdUrTS42",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair 5XFb",
+ "content": {
+ "metareview": "Reviewers appreciate the problem and call it underexplored. BWXy and BUtu credit the design for responding to the acquisition geometry of RCM rather than transplanting an existing method. Reviewer BUtu credits the in vivo dataset as a substantial effort in a modality with few public resources. All reviews rated clarity good or excellent. 82mA and BWXy single out the loss ablation as clean and convincing on its own terms.\n\nAcross reviews, the dominant objection is unanimous. All note that the paper compares only against classical, non-learned interpolation. All also would expect outperforming those baselines given that the proposed model is supervised and considerably more complex. No reviewer was able to determine whether the gains follow from the RCM-specific design or from the use of a large learned model. Reviewers BWXy and 82mA mention that the margin over the best classical method is comparable to the spread among the classical methods themselves, which sharpens the concern rather than resolving it. 82mA names specific learned comparators that would settle the question.\n\n82mA and BUtu also raise hallucination. The model synthesizes structure that was never observed. The paper describes the output as anatomically plausible without any clinician assessment, uncertainty analysis, or downstream evaluation that would distinguish faithful reconstruction from plausible-looking reconstruction. 82mA questions whether a neural approach is warranted at all given the modest gains, stating that adequate motivation would raise their score. BWXy asks a related question about why other generative models were not treated as applicable.\n\nIn addition, the paper states that subject-level metadata is unavailable. Splits are therefore performed at the level of individual stacks and are described as only effectively disjoint. Did stacks from the same subject appear on both sides? This would favour a learned method.\n\nThe response should at least\n* provide at least one strong learned baseline\n* address the split and leakage question above\n* give an explicit justification for the neural formulation and the view-synthesis framing.\n\n---\n\nThe rebuttal and discussion addressed several of the main concerns. The authors added a per-stack NeRF-like coordinate MLP, FILM in zero-shot and fine-tuned settings, and bilinear interpolation. CD-RCM performs best on the reported metrics. This provides evidence that the gains do not follow simply from using a learned model. Possible train–evaluation overlap was also investigated, with one likely same-site overlap and authors showed that the aggregate results remain essentially unchanged after excluding suspected overlaps. Because subject identifiers were not retained, a subject-disjoint split still cannot be guaranteed and should remain a stated limitation.\n\nReviewers BWXy and BUtu considered their main concerns addressed and moved their scores. Reviewer 82mA maintained a reject recommendation and raised concerns about the interpretation of the method in relation to optical resolution, the choice of Plücker embeddings, and missing related work. The authors subsequently clarified that the method increases axial sampling density within the existing optical resolution and does not claim recovery of information beyond the diffraction limit. They also agreed to narrow the corresponding claims and expand the discussion of alternative encodings and related microscopy methods. I consider the optical-resolution clarification adequate. The lack of an encoding ablation remains a secondary weakness.\n\nThe main unresolved concern is the faithfulness of synthesized intermediate slices. The method uses a learned prior to predict unobserved tissue structure, while the current evaluation is based on image-quality and perceptual metrics. The planned clinical-expert evaluation was not available during review, and the current dataset does not permit evaluation on the motivating downstream clinical tasks. This issue was raised in different forms across the reviews and remains important given the intended use of the reconstructed images.\n\nBalancing this, I recommend acceptance as a poster. The dominant objection in the preliminary meta-review was that the paper compared only against classical interpolation. This left open whether the gains came from the RCM-specific design or simply from using a learned model. The authors answered this directly. The two learned comparators added during rebuttal fail in informative ways: the per-stack coordinate MLP fits the observed slices but underperforms every classical baseline at held-out depths, having no cross-stack prior, while fine-tuned FILM improves photometric scores by smoothing away the high-frequency tissue detail that\nmatters here. That is evidence for the specific design rather than a generic capacity effect. The leakage question was investigated and the residual limitation is stated.\n\nI'm not following 82mA's recommendation, because the review's central objection was that the method implicitly claims recovery of structure below the diffraction limit. The authors clarified that the method increases axial sampling density within the existing optical resolution and makes no such claim. Authors also agreed to narrow the corresponding text. The clarification was adequate and with the\nclaims narrowed the objection largely goes away. 82mA's final justification reproduces their earlier comment verbatim and therefore predates the clarification, so it didn't engage with the response. The two remaining points (absence of an encoding ablation, missing microscopy deconvolution literature) are legitimate but addressable in the camera-ready.\n\nThe faithfulness of synthesized intermediate slices remains an open question. I am treating it as a camera-ready condition, because the contribution is use-inspired and the paper's claims are now scoped to increased axial sampling rather than to diagnostic sufficiency. \n\nFor the camera-ready I'd expect:\n* the completed clinician assessment the authors committed to\n* an explicit statement of what the method can and cannot recover, placed such that a reader sees it rather than in a limitations paragraph\n* the encoding ablation\n* the missing related work\n* the split limitation retained in the text (not softened).\n\nReviewers BWXy and BUtu both moved to the accept range on the strength of the rebuttal. BWXy's remaining reservation concerns evidence the current dataset cannot supply rather than a defect in the work."
+ },
+ "createdAt": "2026-07-22T19:38:19.018Z",
+ "modifiedAt": "2026-11-18T15:18:10.378Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=ojVdUrTS42",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/oklp1lwlos.json added

+++ b/reviews/openreview/0waapzbygt/notes/oklp1lwlos.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "okLP1lwlOs",
+ "replyTo": "vgXmVXpU8c",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for the careful assessment and for recognizing CD-RCM’s domain-specific framing as a novel application of neural view synthesis to optical sectioning microscopy. This is the central objective of the paper: to establish continuous-depth RCM reconstruction as a technically viable novel-view synthesis problem and motivate further research at this intersection.\n\nWe thank the reviewer for recognizing the “domain-specific framing” of CD-RCM as “relatively speaking, a novel application of neural view synthesis to optical sectioning microscopy and demonstrates its potential for continuous-depth reconstruction in RCM.” This is indeed the central objective of this paper, i.e., to establish continuous-depth RCM reconstruction as a technically viable novel-view synthesis problem, and to motivate further research on this intersection.\n\n**A. It is difficult to determine whether the gains arise from the proposed RCM-specific design or simply from the use of a large learned model… Compare CD-RCM against at least one modern learning-based interpolation or reconstruction baseline.**\n\nWe agree that this distinction should be made clearer and report additional learned baselines in our response to Reviewer 82mA (point B) and Reviewer BWXy (point A) to directly examine whether generic neural model capacity alone is sufficient for this task.\nThe NeRF-like per-stack coordinate MLP underperforms every classical interpolation baseline, despite accurately fitting the observed input slices. Because it is optimized independently for each stack, it cannot learn a cross-stack prior over depth-dependent tissue morphology. Similarly, FILM does not reliably preserve RCM morphology: zero-shot inference introduces discontinuous and morphologically implausible structures, while fine-tuning improves PSNR and SSIM primarily by producing smoother predictions, at the expense of both perceptual metrics. In addition, our training-objective ablation holds the CD-RCM architecture fixed and shows that replacing the proposed skin-specific perceptual supervision with a standard perceptual loss degrades performance across all metrics.\n\nTaken together, these results indicate that the gains do not arise merely from applying a large learned model. Rather, they depend on the RCM-specific formulation of CD-RCM, which leverages the structured axial acquisition process of optical sectioning microscopy, represents depth as a continuous and queryable dimension, and learns a cross-stack prior over depth-dependent tissue morphology. We will revise the manuscript to make this distinction and the supporting evidence more explicit.\n\n**B. Generalization across devices, institutions, patient populations, pathological conditions, imaging settings, and tissue types; biological validity of synthesized slices.**\n\nWe agree that these broader forms of generalization and biological validity have not yet been established. In the current paper, generalization refers specifically to inference on held-out RCM stacks and skin sites within the evaluated data distribution (i.e., healthy skin acquired using the same imaging platform). It does not imply demonstrated generalization across devices, institutions, patient populations, pathological conditions, or other tissue types. We will revise the manuscript to define this scope more precisely and avoid broader interpretations of the term “generalizable.”\n\nThis limited scope is intentional for the present proof-of-concept study. The primary goal is to demonstrate that continuous-depth RCM reconstruction can be formulated as a novel-view synthesis problem and to provide initial evidence that this direction is technically viable. Establishing this feasibility is a necessary first step before undertaking larger studies involving pathological tissue, more diverse populations, multiple devices and institutions, and task-specific clinical annotations.\n\nAs described in our response to Reviewer 82mA (point C), we will also include an evaluation facilitated by clinical experts to assess the anatomical fidelity of the reconstructed views, identify morphologically implausible or hallucinated structures, and examine their potential utility for DEJ localization. We emphasize that this evaluation will provide an initial assessment of reconstruction fidelity and potential clinical utility, rather than establish clinical efficacy or broad biological validity. We will explicitly identify external validation across pathological tissue, imaging devices, institutions, and patient populations as necessary future work.\n\n**C. Public release of the code and dataset.**\n\nWe plan to release the model code and trained checkpoints to facilitate reproducibility and further research. Unfortunately, we cannot publicly release the RCM dataset because of institutional and data-governance constraints associated with the clinical data.\nWe will add a clear data-availability statement to the manuscript. Subject to the required institutional approvals and data-use agreements, we will also work with our clinical collaborators to provide controlled access to qualified academic researchers where possible.\n\n**D. Sensitivity to residual registration errors.**\n\nWe thank the reviewer for this valuable suggestion. CD-RCM assumes that the input slices are approximately laterally aligned. Although SIFT-based affine registration substantially reduces inter-slice motion, residual misalignment remains possible and may degrade reconstruction quality.\n\nTo quantify this sensitivity, we will add a controlled robustness analysis with increasing levels of synthetic registration error applied to the conditioning slices using small two-dimensional affine perturbations, and report the resulting impact on the quantitative metrics. We will also evaluate registration-noise augmentation during training, using random translations and other small affine perturbations, to determine whether it improves robustness to residual misalignment.\n\nWe will report these results in the camera-ready version, and clarify that CD-RCM requires reasonably aligned input stacks, and substantial motion remains an important limitation and direction for future work."
+ },
+ "createdAt": "2026-07-28T04:18:07.642Z",
+ "modifiedAt": "2026-11-18T17:10:33.447Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=okLP1lwlOs",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/olxu5xxebx.json added

+++ b/reviews/openreview/0waapzbygt/notes/olxu5xxebx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "olxu5xXEBX",
+ "replyTo": "z8QBpTT6T0",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for their valuable feedback, for describing CD-RCM as ‘well-written’, ‘promising’, and for appreciating its ‘sub-second inference time, which is attractive for interactive imaging’. Below, we address their feedback and questions:\n\n**A. Since the proposed method is** ***supervised*** **and considerably more complex, it is reasonable to expect a substantial improvement … Without comparison to more sophisticated baselines, the evaluation is not fully convincing**\n\nWe agree that comparison with learned baselines is necessary and have added these experiments, as detailed in our response to Reviewer 82mA (point B). Taken together, these results show that trivially adapting existing learned interpolation methods does not solve the RCM reconstruction problem. The NeRF-like model lacks a cross-stack anatomical prior, while FILM does not reliably preserve depth-dependent morphology. Our formulation is therefore essential for this task because it leverages the structured axial acquisition process of optical sectioning microscopy and models depth as a continuous, queryable dimension, enabling synthesis at arbitrary unseen depths.\n\nWe also clarify the nature of supervision in CD-RCM. The model is supervised using discretely acquired RCM slices, but it does not receive ground-truth supervision at every continuous axial position queried during inference. In particular, no directly acquired reference images exist at arbitrary sub-slice depths between the observed sections. CD-RCM therefore learns from available discrete observations while using the estimated virtual camera parameters to represent axial position as a continuous, queryable variable. This enables the model to synthesize slices at non-integer and previously unseen depths *rather than only at offsets explicitly observed during training*, where conventional neural interpolation methods suffer from severe qualitative degradation.\n\nWe would also like to emphasize that the limited size of the available RCM dataset is an important consideration when selecting the modeling approach. Highly expressive generative models are typically data-hungry and, in this setting, risk mode-collapse or hallucinating anatomically implausible structures without substantially larger and more diverse training data. Our depth-conditioned feedforward formulation is therefore intentional, as it provides the capacity to learn cross-stack morphological priors while remaining practical in the limited-data regime available for this proof-of-concept study.\n\nCD-RCM is not trained to predict only a fixed set of supervised intermediate locations. By leveraging the structured axial acquisition process of optical sectioning microscopy and representing depth as a continuous, queryable variable, the model can synthesize slices at arbitrary unseen depths within the observed stack range. This allows us to achieve the required continuous-depth generalization without relying on a substantially larger dataset of the scale typically needed by more data-intensive generative approaches.\n\n\n**B. It is unclear whether the improvement achieved by the proposed method would have any significant impact on these clinical tasks. Moreover, the dataset does not appear to have the appropriate labels to evaluate performance in these applications.**\n\nWe appreciate the reviewer’s observation and would like to clarify that the primary goal of this paper is not to establish clinical efficacy, but to demonstrate that continuous-depth reconstruction in RCM can be formulated as a novel-view synthesis problem and to provide evidence that this direction is technically viable. Accordingly, the current dataset consists of healthy skin acquired using a single imaging platform and does not include the task-specific labels required to evaluate diagnosis or other clinical endpoints. We will revise the manuscript to make this proof-of-concept objective explicit and to clarify that the work is intended to motivate further investigation of neural view synthesis for optical sectioning microscopy.\n\nEstablishing this technical feasibility is a necessary first step toward larger studies involving pathological cases, more diverse patient populations, multiple acquisition systems, and detailed clinical annotations. As described in our response to Reviewer 82mA (Point C), we will include an evaluation facilitated by clinical experts in the camera-ready version to assess the anatomical fidelity of the reconstructed views and their potential utility for DEJ (Dermal-Epidermal Junction) localization. Note that DEJ is an important feature to localize in skin cancer diagnosis as this is where skin cancer originates. We will also more clearly identify validation on pathological tissue, additional devices, and clinically annotated downstream tasks as important directions for future work."
+ },
+ "createdAt": "2026-07-28T03:53:35.519Z",
+ "modifiedAt": "2026-11-18T17:10:33.280Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=olxu5xXEBX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/vgxmvxpu8c.json added

+++ b/reviews/openreview/0waapzbygt/notes/vgxmvxpu8c.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "vgXmVXpU8c",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer BUtu",
+ "content": {
+ "summary": "This work aims to improve depth-wise visualization in reflectance confocal microscopy (RCM), where sparse axial sampling and anisotropic resolution limit the interpretation of tissue structure. The authors propose CD-RCM, a feedforward transformer-based framework that formulates continuous-depth reconstruction as a novel-view synthesis problem and generates intermediate optical sections at arbitrary depths from sparsely sampled RCM stacks. To account for the unique imaging geometry of RCM, the method models axial acquisition using virtual camera representations and incorporates a skin-specific perceptual feature loss derived from a domain-adapted self-supervised backbone. It is relatively speaking, a novel application of neural view synthesis to optical sectioning microscopy and demonstrates its potential for continuous-depth reconstruction in RCM.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "The paper addresses an important and underexplored problem in biomedical imaging: improving depth-wise visualization of reflectance confocal microscopy (RCM) stacks through continuous-depth reconstruction. The motivation is compelling, as RCM volumes are highly anisotropic and difficult to interpret in cross-sectional views, despite their widespread use in dermatology. The authors propose CD-RCM, a feedforward transformer-based framework that formulates axial densification as a novel-view synthesis problem and generates intermediate optical sections at arbitrary depths. The work further introduces a skin-specific perceptual loss derived from a domain-adapted self-supervised feature extractor to better capture the microstructural characteristics of RCM images.\n\nA key strength of the paper is its domain-specific framing. Rather than directly applying existing neural rendering methods, the authors carefully motivate why RCM differs from both conventional multi-view imaging and tomographic reconstruction, and adapt the model design to reflect the acquisition geometry of optical sectioning microscopy. The problem itself is clinically relevant, and the proposed feedforward inference framework is computationally attractive compared to optimization-based neural rendering approaches. I also appreciate that the study is conducted on a substantial in vivo RCM dataset collected by the authors, which is valuable given the scarcity of publicly available benchmarks in this modality.\n\nThe paper is generally well written and easy to follow. The imaging motivation, architectural design, and training procedure are clearly described, and the qualitative visualizations effectively illustrate the intended application of isotropic reconstruction and arbitrary-plane sectioning.\n\nHowever, I have several concerns regarding the experimental evaluation and the strength of the conclusions. Most importantly, the comparison is limited to classical interpolation methods such as B-spline, cubic spline, and Gaussian interpolation. Since CD-RCM is a learned transformer-based model trained specifically for this task, outperforming traditional interpolation approaches is expected. The paper does not compare against modern learning-based interpolation, reconstruction, or view-synthesis methods, making it difficult to determine whether the gains arise from the proposed RCM-specific design or simply from the use of a large learned model.\n\nA second concern is the limited scope of validation. The dataset consists of healthy skin imaged using a single acquisition platform, and all experiments are performed within this setting. While collecting such a dataset is a notable effort, the current evaluation provides limited evidence regarding generalization across devices, institutions, patient populations, or pathological conditions. As a result, some of the broader claims regarding generalizable reconstruction should be interpreted cautiously.\n\nI am also concerned about the biological validity of synthesized slices. The paper frequently refers to anatomically plausible intermediate sections and highlights improved cross-sectional visualization. However, no clinician evaluation, biological validation, or uncertainty analysis is provided. Because the model generates unobserved intermediate structures, it is important to assess whether diagnostically relevant features are faithfully reconstructed rather than hallucinated. This issue is particularly important if the method is intended to support downstream clinical interpretation.\n\nFinally, although the proposed skin-specific perceptual loss appears beneficial, its contribution is demonstrated primarily through image-quality metrics derived from the same dataset. Additional evidence linking these improvements to biologically meaningful reconstruction quality would strengthen the paper.\n\nIt proposed a new problem and the microscopy motivation is compelling. The adaptation of neural view synthesis concepts to optical sectioning microscopy is interesting and potentially impactful. However, the experimental evaluation does not yet provide sufficiently strong evidence to support the broader claims of generalizable and anatomically faithful reconstruction. Stronger baselines and more rigorous biological validation would substantially strengthen the work.",
+ "quality": 3,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. Can the authors compare CD-RCM against at least one modern learning-based interpolation or reconstruction baseline?\n\nCurrently, the evaluation is limited to classical interpolation methods (B-spline, cubic spline, and Gaussian interpolation). While these are reasonable references, it is difficult to assess the value of the proposed architecture without comparison to a learned baseline. \n\n2. How robust is CD-RCM across different imaging settings and tissue types?\n\nThe dataset collected by the authors is a valuable contribution given the scarcity of publicly available RCM data. However, all experiments appear to be performed on healthy skin acquired using a single imaging platform. Could the authors discuss or provide evidence regarding expected performance on different skin types, anatomical sites, devices, or pathological conditions? \n\n3, How can we assess whether synthesized intermediate slices are anatomically faithful rather than plausible-looking hallucinations?\n\nThe paper demonstrates improvements in image-quality metrics and visual appearance, but clinical utility depends on preserving diagnostically relevant structures. Can the authors provide additional analysis, uncertainty estimates, or expert assessment regarding the fidelity of reconstructed intermediate slices?\n\n4. Will the dataset and code be publicly released?\n\nThe dataset appears to represent a substantial effort and addresses a modality with relatively limited public resources. Releasing the dataset, train/test split, and preprocessing pipeline would significantly improve reproducibility and increase the broader impact of the work. If public release is not possible due to consent or institutional constraints, could the authors clarify whether qualified academic access will be provided and discuss any restrictions on data availability?\n\n5. How sensitive is the method to residual registration errors?\n\nThe paper notes that stack alignment remains a limitation. Since RCM data can contain motion artifacts and imperfect registration, it would be useful to understand how reconstruction quality changes under varying levels of misalignment and whether the model can be made more robust to these effects.",
+ "limitations": "No. The authors appropriately acknowledge residual registration errors and the limited size and diversity of the dataset. However, several important limitations are not sufficiently discussed. First, the evaluation only compares against classical interpolation methods, making it difficult to assess the advantages of the proposed approach relative to modern learning-based alternatives. Second, the paper does not address the possibility that synthesized intermediate slices may contain anatomically plausible but incorrect structures, which is particularly important if the method is intended to support clinical interpretation. Finally, the current evaluation is limited to healthy skin acquired on a single imaging platform, and the implications for generalization to pathological cases, other devices, or broader clinical settings should be discussed more explicitly.",
+ "rating": 5,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "NA",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have addressed my concerns, and since the paper now falls under the *User-Inspired* category, I would revise my recommendation to **accept**. My primary motivation is that the work is interesting, timely, and has the potential to inspire future research in the field. As microscopy datasets are increasingly being integrated with state-of-the-art machine learning models, this study addresses an emerging and relevant direction. Furthermore, the authors demonstrate the potential advantages of their method, and given that the novelty requirement is less stringent for the *User-Inspired* category, I believe the paper meets the bar for an acceptance."
+ },
+ "createdAt": "2026-06-22T10:16:25.712Z",
+ "modifiedAt": "2026-11-18T13:34:52.201Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=vgXmVXpU8c",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/notes/z8qbptt6t0.json added

+++ b/reviews/openreview/0waapzbygt/notes/z8qbptt6t0.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "z8QBpTT6T0",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer BWXy",
+ "content": {
+ "summary": "This paper proposes a model to synthesize novel views for reflectance confocal microscopy, based on neural methods for 3D reconstruction and novel-view synthesis. The approach is capable of synthesizing at arbitrary depths, efficient, and outperforms classic interpolation baselines.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "Strengths\n\n- The paper adapts neural rendering architecture to fit the needs of reflectance confocal microscopy, enabling continuous-depth reconstruction at arbitrary query depths. The paper claims sub-second inference time, which is attractive for interactive imaging.\n\n- The paper is well-written and the experiments include an ablation analysis of its main components.\n\n\nWeaknesses\n\n- While the approach seems promising, the experiments are insufficient. The main limitation is comparing only to simple classical interpolation baselines (B-spline, cubic spline, and Gaussian interpolation). Since the proposed method is supervised and considerably more complex, it is reasonable to expect a substantial improvement. However, the performance gains are modest—the difference in performance between the proposed method and the baselines is similar to the difference among the classical interpolation methods themselves. Without comparison to more sophisticated baselines, the evaluation is not fully convincing.\n\n- The performance metrics are limited to photometric fidelity and perceptual similarity, and the results do not reach a range that justifies strong claims of superiority. For instance, the paper argues that the relevance of reflectance confocal microscopy lies in tasks like tumor diagnosis, inflammatory conditions, and surgical margin assessment. It remains unclear whether the improvement achieved by the proposed method would have any significant impact on these clinical tasks. Moreover, the dataset does not appear to have the appropriate labels to evaluate performance in these applications.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "- I must admit that I did not quite follow why previous generative models cannot be applied the problem. I get that the proposed method was designed specifically for continuous-depth visualization, but if classic interpolation methods (B-spline, cubic spline, and Gaussian interpolation) can be applied and are used as baselines, why would other generative models not be applicable?",
+ "limitations": "yes",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors have added comparison to learned baselines suggested by Reviewer 82mA, demonstrating that the proposed approach can be competitive and outperform them on their dataset. While the dataset does not enable evaluating the effect of its performance on the motivating downstream tasks, the authors will include an evaluation based on feedback from clinical experts, which I hope will enable understanding this aspect better."
+ },
+ "createdAt": "2026-06-25T21:30:36.960Z",
+ "modifiedAt": "2026-11-18T13:34:49.793Z",
+ "url": "https://openreview.net/forum?id=0WaapzByGt&noteId=z8QBpTT6T0",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/0waapzbygt/submission.json added

+++ b/reviews/openreview/0waapzbygt/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "0WaapzByGt",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 690,
+ "url": "https://openreview.net/forum?id=0WaapzByGt",
+ "license": "CC-BY-4.0"
+}

versions/v_cqfdtmte.json added

+++ b/versions/v_cqfdtmte.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-15",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 690,
+ "url": "https://openreview.net/forum?id=0WaapzByGt",
+ "reviews": "openreview/0waapzbygt",
+ "evidence": [
+ "https://openreview.net/forum?id=0WaapzByGt"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=0WaapzByGt",
+ "evidence": [
+ "https://openreview.net/forum?id=0WaapzByGt"
+ ]
+}