potentialpaper

UniDG: Unified Defect Generation via Defect-Context Editing

Update NeurIPS 2026 submission A3soBL3Ciu: 17 notes

@openreview[bot] · 2026-11-24 15:46 UTC · 12d348da08b0 ·

Evidence

reviews/openreview/a3sobl3ciu/notes/1n5pqoz4ji.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/1n5pqoz4ji.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "1N5PQoZ4Ji",
+ "replyTo": "bFLK70Qxw0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Continued (2/3): licensing compatibility",
+ "comment": "Continuing our response (2 of 3) — your point 2, which is the one we found to be worse than your review diagnosed.\n\n## 2. Licensing compatibility\n\nThe reviewer is right that MIT for project code does not override upstream terms. Two instances.\n\n**The medical subset cannot be MIT.** Several sources are CC BY-NC-SA 4.0, whose ShareAlike term obliges derivatives to carry the same licence; CVC and Kvasir-SEG forbid commercial use. Our quadruplets are derivatives of those images.\n\n**Neither can the weights.** UniDG is a set of adapters on FLUX.1-Fill-dev and FLUX.1-Redux-dev, whose licence defines a Derivative to include \"any customized or fine-tuned version thereof\" and extends its restrictions to Derivatives. The weights must carry the FLUX.1 [dev] Non-Commercial License.\n\n| Asset | Governing terms | Redistributed | Commercial |\n|---|---|---|---|\n| Project code | MIT, ours | yes | yes |\n| UniDG weights | FLUX.1 [dev] Non-Commercial, inherited | yes, under that licence | **no** |\n| Reward models | upstream base-model licence, named in the release table | per that licence | per that licence |\n| Medical images and everything derived from them — quadruplets, masks, captions, synthetic images | per-source, as in §1 | **no** — metadata and scripts only, so it can be rebuilt after accepting each provider's terms | no |\n| Industrial and natural source images | per-source, heterogeneous | only where the source permits; else metadata + scripts | per-source |\n| Recovered normals, non-medical (Inpainting Agent outputs) | Outputs under FLUX.1 [dev]; not Derivatives | where the source image permits | permitted, **except** to train a model competitive with FLUX.1 [dev] |\n| Masks and captions we produced, non-medical | MIT annotation layer, bound by source terms where they encode source content | with source constraints | same |\n\nThe mechanism for the medical rows is the paper's own one for restricted industrial sources, made concrete: per quadruplet we ship the source dataset, the original image identifier, and the mask, caption and generation parameters needed to rebuild it — never the image. Anyone accepting each provider's terms can reconstruct the subset exactly; we redistribute no medical pixels. Our error was announcing a blanket MIT release without checking it applied."
+ },
+ "createdAt": "2026-07-30T08:03:02.840Z",
+ "modifiedAt": "2026-11-19T17:14:33.323Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=1N5PQoZ4Ji",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/9qcn0ugbhb.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/9qcn0ugbhb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "9QCn0UgBhB",
+ "replyTo": "razTByywDw",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Summary of the discussion period: what we delivered and what we are changing in the paper (1/2)",
+ "comment": "Dear Area Chair,\n\nThis is a closing note at the end of the discussion period. Our first note was an index of where each meta-review point was answered plus two proactive disclosures; this one reports what the discussion itself produced. Three things: every item we promised in a thread has now been posted, both reviewer follow-ups converged on one question that we had answered badly the first time, and the full list of what we have withdrawn, corrected or narrowed is collected in one place below.\n\n## 1. Every in-thread commitment is now closed\n\n| Promised | Thread | Outcome |\n|---|---|---|\n| Mask-quality sensitivity sweep | JHNj | Posted. FG-mIoU 31.87 unperturbed against 24.6 in the worst setting (erosion by 11 px), while RefAd moves only 4.04 → 3.72, because mask geometry never touches the reference stream — what erodes is localization, not defect appearance. Erosion hurts more than dilation, consistent with Adaptive Defect Crop already training the model in a dilated regime. So downstream results are mask-sensitive gradually rather than sharply, and even the worst setting stays above InsertAnything's 15.63 with unperturbed masks. |\n| Fixed-epoch downstream rerun, no checkpoint selection | nT6U, and your §3 | Posted. Removing the best-of-20 rule costs roughly one absolute point for **every** method and the ordering is unchanged: UniDG-RFT over InsertAnything is 13.7 Acc-C and 16.1 FG-mIoU fixed-epoch, against 13.8 and 16.24 before. The rule inflated absolutes uniformly rather than favouring us. Fixed-epoch becomes the primary protocol; best-of-20 moves to an appendix with the rule stated in the caption. |\n| Split-isolation overlap counts | nT6U | Posted, and zero on all three intersections — UDG training against MVTec-AD evaluation, against VisA evaluation, and generation references against downstream evaluation images. Method: SHA-256 over decoded pixels plus pHash (Hamming ≤ 5 as a candidate, every candidate inspected by hand), run over the final UDG manifest rather than the source-dataset list. |\n| Smaller-backbone experiment | JHNj and ruex follow-ups | New; §2 below. |\n\nThe data-scale ablation (d1), the blinded failure audit (d2 and c1) and KID plus IS (a) were posted in the first round and are unchanged.\n\n## 2. Both follow-ups asked one question, and our first answers to it were poor\n\nruex and JHNj independently returned to backbone size. In ruex's thread we had offered W4A4 quantization as the answer; the reviewer correctly rejected it, since W4A4 lowers the numerical precision of a trained 12B function rather than reducing capacity, and we withdrew it. In JHNj's thread we had declined the experiment as impossible to run honestly. Both answers failed the same way: we asserted a blanket porting cost without distinguishing across backbone families from within one.\n\nWithin the FLUX family only one of our four couplings to FLUX.1-Fill actually breaks. FLUX-Mini (3.2B, depth reduced from 19+38 to 5+10 blocks) keeps hidden size 3072, condition dim 4096, the RoPE axis configuration and the FLUX VAE, so the Redux reference stream, the diptych 2-D RoPE and Defect Attention port unchanged. Only the masked-input stem breaks, and only because FLUX-Mini is distilled from FLUX.1-dev rather than from Fill: it must be widened 64 → 384 with the 320 new channels zero-initialised.\n\nAt matched step budgets against Table 7's existing 12B rows, the 3.2B backbone retains 45% of FG-mIoU at 2K steps and 59% at 6K. Changing only the *formulation* on the same 12B backbone (InsertAnything, same UDG data, Appendix M) retains 55% and 57% across the two stages. The capacity cost shrinks as training proceeds; the formulation cost does not. Two limits we would rather state than bury: because of that widened stem the small model must learn Fill's verbatim-reproduction behaviour during our SFT, so the gap is an upper bound on the capacity cost rather than a clean estimate of it; and 6K steps is well short of convergence, so this bounds the ordering, not the converged gap. The 14K run goes into the camera-ready against Table 7's 14K row, reported whatever it shows, including a gap large enough to narrow the paper's claim to the evaluated scale."
+ },
+ "createdAt": "2026-08-04T03:35:43.797Z",
+ "modifiedAt": "2026-11-19T17:14:33.006Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=9QCn0UgBhB",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/a9ednnthre.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/a9ednnthre.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "A9EdNNtHrE",
+ "replyTo": "TxI6NxaPm6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer ruex",
+ "content": {
+ "comment": "Most of my issues are addressed. However, while I understand that \"W4A4 post-training quantization (Appendix I, Table 18) cuts the BF16-equivalent footprint from 12B to 3.3B and VRAM from 28 GB to 9 GB,\", that is not equivalent to using a small model. Could you please explain why \"moving to a 2–3B DiT means rebuilding that conditioning and retuning the recipe\"> Even in-perfect result will be acceptable."
+ },
+ "createdAt": "2026-08-02T17:24:18.275Z",
+ "modifiedAt": "2026-11-19T17:14:32.903Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=A9EdNNtHrE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/bflk70qxw0.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/bflk70qxw0.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "bFLK70Qxw0",
+ "replyTo": "OJ0A7WqtWB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response (1/3): medical provenance, consent, and de-identification",
+ "comment": "We thank the ethics reviewer for a review more useful than most of the technical ones, and for separating what is intrinsic to the work from a documentation failure. We accept the Yellow assessment. Point 1 was the hardest to answer honestly and point 2 is worse than diagnosed.\n\n## 1. Medical-data provenance, consent, de-identification\n\nThe reviewer asks us to identify the medical sources and document each; the submission names none while claiming medical scope, which is the real failure. Below is the medical portion in full — OCT and liver via the BMAD anomaly-detection reorganisation, Kvasir-SEG evaluation-only.\n\n| Source (modality) | Ethics basis per the provider | De-identification | Reuse terms |\n|---|---|---|---|\n| BraTS 2018/19/20 (brain MRI) | Multi-institutional, CBICA-curated, partly TCGA via TCIA; HIPAA framework | Skull-stripped and template-registered, removing the facial surface | Data usage agreement; three named manuscripts must be cited; re-identification and face reconstruction prohibited |\n| ISIC (dermoscopy) | Contributor warranty of no protected health information, which the archive does not verify | Warranty-based, not anatomical | Public research archive; reuse under each contributing owner's terms |\n| CVC-ClinicDB, CVC-ColonDB, EndoScene (colonoscopy) | Hospital Clínic Barcelona endoscopy unit; 912 frames, 36 patients | Intestinal lumen views | Research and education only, **commercial use forbidden**; images remain hospital property; citation required |\n| TN3K (thyroid ultrasound) | 3,493 images, 2,421 patients, partner hospital, 2016–2020 | Grayscale, non-ultrasound screen region cropped, removing burned-in banners | Dataset card states MIT; three publications requested |\n| RESC (retinal OCT) | Retinal Edema Segmentation Challenge | Retinal cross-sections | Original release: research community only; BMAD reorganisation CC BY-NC-SA |\n| BTCV + LiTS (abdominal CT) | Seven contributing sites agreed to public release; ethics approval not required | Anonymised, visually reviewed for identifiers; abdomen only, no head in frame | LiTS **CC BY-NC-SA 4.0**; BTCV via registered access |\n| ATLAS (liver CE-MRI) | Anonymised per University Hospital Dijon's ethics committee; no approval number required under French law | Administrative metadata removed | **CC BY-NC-SA 4.0** |\n| Kvasir-SEG (colonoscopy), eval only | Vestre Viken Health Trust; gastroenterologist-verified | Intestinal lumen views | Research and education only; non-commercial without written permission; citation required |\n\nThree points. **Consent sits upstream and we cannot attest to it**: we hold no patient-level consent documentation for any source, and the paper will say so rather than imply verification; what we can state is that each was released for research reuse by the institution that collected it, through the access route its providers specify. **De-identification is mostly a property of the modality** — lumen views, retinal cross-sections, skull-stripped volumes, abdomen-only fields, cropped ultrasound — with **ISIC the exception**, where the only guarantee is a contributor warranty the archive does not verify; we will say exactly that. **None of these sources is currently cited**, and for BraTS, CVC, TN3K and Kvasir-SEG that is a condition of use rather than a courtesy — a live compliance failure we are fixing, BraTS's three named manuscripts included."
+ },
+ "createdAt": "2026-07-30T08:02:36.103Z",
+ "modifiedAt": "2026-11-19T17:14:33.362Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=bFLK70Qxw0",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/bptdmjy41i.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/bptdmjy41i.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "BpTdmjY41I",
+ "replyTo": "m7Ex0CLeb1",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response: renaming UniDG and clarifying data-quality claims",
+ "comment": "We thank the ethics reviewer for separating what the paper actually claims from what its title implies. That distinction is the right one, and we are adopting the recommendation.\n\n## 1. The \"universal\" claim, and the rename\n\nWhat we meant by \"universal\" was a property of the training protocol rather than of the data. Prior few-shot anomaly generation fits one model per object category and cannot produce defects for a category it was not trained on; UniDG trains once and transfers to unseen categories, datasets, and domains with no per-category retraining. That contrast is what we wanted the name to carry.\n\nThe reviewer is right that the word does not survive contact with the dataset. A curated pool of public defect corpora cannot be exhaustive over defect space, and \"universal\" invites exactly the reading that it is — and the distinction we intended is not one a reader can recover from a single adjective.\n\nOur fix keeps the method name and drops the claim: **UniDG becomes \"Unified Defect Generation\"**, with the title \"UniDG: Unified Defect Generation via Defect-Context Editing\". \"Unified\" states what we actually demonstrate — one model in place of a family of per-category models — without asserting coverage, and the acronym, figure labels, and any existing citation of the method all survive unchanged. We will ask the AC and program chairs to approve the title change for the camera-ready.\n\nWe are also removing \"universal\" from the places in the body where it modifies the dataset or the capability rather than the protocol, and adding one sentence stating the boundary explicitly: transfer to the held-out benchmarks we evaluate, not coverage of defect space.\n\n## 2. A related documentation gap, raised unprompted\n\nThe same check surfaced a scope problem one level down, which we would rather report here than have surface later.\n\nUDG is described as spanning \"industrial, natural, and medical scenarios\", and the medical part is real — brain MRI, dermoscopy, colonoscopy, thyroid ultrasound, retinal OCT and liver imaging, from public research releases. But the submission never names a single one of those sources, so no reader can check their provenance, consent basis, de-identification, or licence. Ethics reviewers adin and CMZU both asked for exactly that, and our replies to them give the full per-source account. Two things came out of it that bear on scope language rather than on ethics alone: several of those sources carry non-commercial or ShareAlike terms that our announced MIT release cannot cover, and none of them is currently cited even though citation is a condition of use for four of them.\n\nSo the correction here is narrower than the title but the same in kind: we claimed a breadth of coverage without documenting what backed it. The per-source table will carry a domain label and the citation each provider requires, and the medical subset ships as metadata and curation scripts — image identifiers and the parameters needed to rebuild each sample — rather than redistributed images.\n\n## 3. On reviewer nT6U's flag\n\nSince the reviewer offered to revisit given elaboration, here is our reading of it.\n\nnT6U's stated weaknesses were cross-domain coverage, the absence of KID, and figure legibility, and the flag is labelled \"data quality and representativeness\". We take it to be about the curation pipeline rather than about harm. UDG's normal counterparts are model-generated, and its captions and masks are machine-produced and machine-filtered, so a reader may reasonably ask how much of the retained 300K is actually correct, and whether aggregating public datasets amounts to representativeness.\n\nOn quality, Appendix N reports what the pipeline *rejects* — 19.84% removed below caption confidence 0.8, at 92.3% precision against a 500-sample human calibration, and a further ~30% discarded by the Verifier Agent below an average Likert 4.2 across normality, caption consistency, and defect existence — but never the quality of what it keeps. We have now audited that: on 500 stratified retained samples, image/mask validity is 96.4%, caption correctness 95.6%, and 97.1% of recovered normal images were judged both defect-free and artifact-free.\n\nOn representativeness we agree with the substance rather than defend it. Aggregated public corpora are not a sample of proprietary deployment distributions, rare defect types remain unevenly covered, and both limitations move from the appendix into the main text. Our full response is in the nT6U thread.\n\nThe recommendation identified a real over-claim, and correcting it costs us nothing we were entitled to claim in the first place."
+ },
+ "createdAt": "2026-07-30T08:04:06.002Z",
+ "modifiedAt": "2026-11-19T17:14:33.494Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=BpTdmjY41I",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/civymsrdqb.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/civymsrdqb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "CiVyMsRdQb",
+ "replyTo": "9QCn0UgBhB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Summary of the discussion period: what we delivered and what we are changing in the paper (2/2)",
+ "comment": "Dear Area Chair, continuing the closing note above (2 of 2).\n\n## 3. Where the reviewers stand\n\nruex wrote that most issues were addressed and left one question, which §2 answers. JHNj wrote that the response clarified our claims, asked for exactly the smaller-model experiment above, and said they were open to raising their score. nT6U's two owed items are delivered, and its ethics flag on data quality and representativeness is answered with the retained-sample audit (500 stratified samples: image/mask validity 96.4%, caption correctness 95.6%, 97.1% of recovered normals defect-free and artifact-free) together with the per-source documentation from the ethics threads. We are not claiming any score will move. We are reporting that no question raised in any thread is still unanswered by us.\n\n## 4. The complete ledger\n\n**Withdrawn.** The claim that UniDG-Text outperforms proprietary editing models, raised unprompted and matching your point (c2). W4A4 as evidence about backbone capacity.\n\n**Corrected.** Table 16's SeaS VisA classification column, 84.67 → 63.62, with no UniDG result affected. The downstream checkpoint-selection rule, disclosed and then replaced by measurement. UDG's medical sources, named for the first time with per-source provenance, consent basis and de-identification status, including what we cannot attest to: we hold no patient-level consent documentation for any source. The MIT release commitment, which neither the medical subset nor the adapter weights can carry. The missing citations for the medical sources, Kvasir-SEG and GoodsAD, which for four of those providers is a stated condition of use rather than a courtesy.\n\n**Narrowed.** \"Domain-agnostic\" becomes transfer to the evaluated held-out benchmarks without target-benchmark or category-specific fine-tuning. \"Training-Free Few-Shot\" becomes no target-benchmark training. Consistency-RFT becomes an optional alignment stage with a bounded benefit — 575.81 GPU-hours buys a 20–25% relative reduction in reference and context mismatch, no change in mask violations and essentially nothing on AP/PRO. Defect Attention is reported as the weakest component at +0.6 Acc and +0.7 FG-mIoU. Realism and diversity are presented as a trade-off rather than a joint win: DualAnoDiff leads on IL (0.37 against our 0.28) and the per-category baselines lead on KID, which we predicted in writing before measuring it. \"Universal\" becomes \"Unified\", pending approval.\n\n**What survives all of that.** The three components expressing the data formulation account for 79% of the FG-mIoU gain, and stopping after Diversity-SFT recovers 82% of it, so the parts we demote are the ones taken off the shelf. On a shared backbone with shared UDG data the formulation alone is worth 12.9 MC-FG-mIoU, while RFT without SFT collapses to FG-mIoU 4.7. Under the fixed-epoch protocol with no checkpoint selection at all, the margins hold. None of this rests on a withdrawn claim or a corrected table.\n\n## 5. What is camera-ready work rather than in-thread work\n\nThe FLUX-Mini 14K run; the per-source appendix table pairing every dataset with its citation and its terms of use; the Inpainting Agent's omitted compute row and the energy estimate; and the metadata-plus-curation-scripts release path that replaces image redistribution for the medical subset.\n\nThe one thing we would ask of you is whether a camera-ready title change from \"Universal\" to \"Unified\" is acceptable to you and the program chairs. And if anything in any thread still looks unresolved, we would welcome the chance to discuss it while the discussion period is open."
+ },
+ "createdAt": "2026-08-04T03:36:31.106Z",
+ "modifiedAt": "2026-11-19T17:14:32.879Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=CiVyMsRdQb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/ebbnyhmjcr.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/ebbnyhmjcr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "EBBnYHmjCR",
+ "replyTo": "0PgqBFWhxc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer JHNj",
+ "content": {
+ "comment": "I really appreciate the authors for the efforts and time to do the rebuttal within limited time. I was able to understand better on the claims the authors made. That being said, I still hope the authors can at least describe the experiments for smaller models (even though some details are adjusted while core components remain same) to better claim the method. I am open to raise my score based on the response."
+ },
+ "createdAt": "2026-08-02T16:27:01.768Z",
+ "modifiedAt": "2026-11-19T17:14:33.659Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=EBBnYHmjCR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/emdcx1mb1x.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/emdcx1mb1x.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "eMdcx1Mb1X",
+ "replyTo": "1N5PQoZ4Ji",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Continued (3/3): medical claims, release, annotation, and compute",
+ "comment": "Continuing our response (3 of 3) — your points 3 to 6.\n\n## 3. Medical and safety-critical claims\n\nAll four requested changes are accepted. The Kvasir-SEG result is restated in the main text as a 120-image, single-lesion domain-shift probe and explicitly not a clinical validation; medical diagnosis is no longer presented as an application we validate; and the no-clinical-use qualification moves into the main discussion rather than only the cards — no diagnostic-model training or clinical decision-making without specialist review, external validation, subgroup analysis and calibration assessment. We add the shortcut risk the reviewer names: it is a real failure mode of our method and we discuss only its industrial analogue.\n\nOne addition: the pipeline also *removes* abnormalities to build a \"normal\" counterpart, so it generates plausible healthy brains, retinas and livers that no patient ever presented, alongside synthetic tumours, polyps and lesions. Both directions are first-order risks; no synthetic medical image will be released.\n\n## 4. Responsible-release safeguards\n\nThe reviewer is right that our plan is advisory documentation presented as a safeguard, and we will say so in those words: responsible-use guidance is not enforceable and does not stop anyone fabricating inspection or medical evidence.\n\nCommitments: state the advisory limitation explicitly; gate weight distribution behind an accepted use statement, with code and metadata open; **release no medical-derived asset**, the reviewer's \"separate release decisions for higher-risk medical assets\", now forced by §2 as well as chosen; provenance metadata on published synthetic images and watermarking on by default in the released script, both flagged as removable aids rather than controls; a named misuse-reporting contact in the model card; a written proportionality argument for open code plus gated weights, the benefit being reproducibility of a recipe rather than a new capability; and, if the ethics chairs require it, a pre-release red-team run on how often off-the-shelf detectors catch fabricated-defect outputs — specifiable now, not completable inside the discussion window.\n\nOne consequence of §2 helps here: because the weights carry the FLUX non-commercial licence, commercial deployment is restricted by licence rather than by request — stronger than the MIT release we announced.\n\n## 5. Human-participant and annotation documentation\n\nAgreed, and flagged against ourselves in checklist item 15. Six human components exist that the paper never lists together — the 30-participant study, UDG-Reward-Bench, the caption calibration, the curation boundary review, the taxonomy mapping, and a new two-annotator failure audit. Reviewer adin's thread carries the full inventory with scales, plus every item on this reviewer's list. The annotators were students recruited within our institution, not crowdworkers or a vendor, paid per completed task; none handled patient-identifying material. The effective rate is roughly USD 8–10 per hour, well above the applicable statutory minimum; we quote dollars rather than the local currency only because the currency would identify our region during review.\n\n## 6. Environmental reporting\n\nTable 23's 983.29 GPU-hours covers those four training stages and nothing else. It excludes Inpainting Agent training — our own compute, which should have been a row — plus Captioner and Verifier inference over the curation pool, the Gemini-3-Pro and GPT-5.1 evaluation calls, and inference for reported results. The Inpainting Agent becomes a measured row; the rest we report as per-agent call volumes, since third-party API inference cannot honestly be converted to GPU-hours.\n\nFor the estimate, assumptions stated rather than buried: 983.29 A800-hours at a 400 W board TDP is ≈393 kWh of GPU energy; a host-and-facility factor of 1.5 gives ≈590 kWh; at 0.55 kg CO2e/kWh that is ≈0.32 t CO2e. Board power was not instrumented, so this is arithmetic from a nameplate figure and will be labelled as such.\n\nWe are grateful for the detail. Points 1 and 2 are failures we would not have found on our own schedule."
+ },
+ "createdAt": "2026-07-30T08:03:28.878Z",
+ "modifiedAt": "2026-11-19T17:14:33.506Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=eMdcx1Mb1X",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/gusibvbnre.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/gusibvbnre.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "gUSibVbnrE",
+ "replyTo": "qDq8ASz5t2",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Continued (3/3): annotation documentation and compensation",
+ "comment": "Continuing our response (3 of 3) — your second point, the human-participant and annotation documentation.\n\n## 2. Human annotation: participant details and compensation\n\nThis gap is real and we had flagged it against ourselves — checklist item 15 states that the manuscript \"does not yet include the full participant instructions, rating-interface screenshots/materials, or compensation details\". The reviewer is right that flagging it is not fixing it.\n\n**What the paper does state** (checklist item 16): raters were informed of the task purpose, the voluntary nature of participation and the intended research use, and gave informed consent before starting; the study was reviewed internally under our institution's standard procedure for minimal-risk image-rating studies. We withheld the reviewing body only for anonymity at submission and will name it in the camera-ready.\n\n**The complete inventory of human work**, which the paper never presents in one place:\n\n| Component | Task | Scale |\n|---|---|---|\n| User study (Sec. 6) | Rate images on 4 dimensions, 1–5 scale, plus Good-Same-Bad | 30 participants |\n| UDG-Reward-Bench | Score 4 dimensions and write an analysis per editing pair | 500 pairs, dozens of annotators |\n| Captioner calibration (App. N) | Judge each caption accurate or inaccurate | 500 captions |\n| Curation boundary review (App. N) | Inspect quadruplets near the filter threshold | ~5,000 cases |\n| Taxonomy mapping | Map 269 raw defect names to 28 categories | one pass, manual |\n| Failure audit (new) | Blinded per-defect-type failure labelling, two annotators | 365 inputs |\n\n**What we will add**, item by item against the reviewer's request: recruitment channel and eligibility criteria; verbatim instruction text for each task; screenshots of each rating interface; median duration and total workload per annotator; ratings completed per annotator; the compensation scheme with the local-currency rate; and anonymized ethics-review status. No annotator saw patient-identifying material: the medical images they reviewed are the de-identified public frames described above.\n\nOn who did the work and how they were paid: the annotators were students recruited within our own institution, not crowdsourcing workers and not an external vendor, paid per completed task at a rate agreed before they began. Converting the per-task rate through the median time each task actually took, the effective rate works out to roughly **USD 8–10 per hour**, well above the applicable statutory minimum hourly wage. We give it in dollars rather than the local currency only because the currency would identify our region during review; the exact local figure, the median duration per task type and the per-annotator workload go into the camera-ready appendix.\n\nThe internal review named above covered that study; the remaining tasks are image labelling by recruited annotators and did not go through a separate review — we say so plainly rather than imply an approval we do not have.\n\nAll tasks are image rating or labelling with no sensitive personal content, so we agree this is a transparency and labour-documentation issue rather than a participant-risk one — but it is one we should have documented before submission."
+ },
+ "createdAt": "2026-07-30T08:06:16.481Z",
+ "modifiedAt": "2026-11-19T17:14:33.388Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=gUSibVbnrE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/pygbrbopoe.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/pygbrbopoe.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PYgBrBOpoE",
+ "replyTo": "Jfj8uRnhJ6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We promised two things in this thread during the discussion period, and both are below.\n\n## 1. Split isolation: the two overlap counts\n\nMethod: exact-content hashing (SHA-256 over decoded pixels) plus perceptual hashing (pHash, Hamming distance <= 5 counted as a candidate match, all candidates inspected by hand), run over the final UDG manifest rather than the source-dataset list.\n\n| Intersection | Overlaps |\n|---|---:|\n| UDG training images vs. MVTec-AD evaluation images | 0 |\n| UDG training images vs. VisA evaluation images | 0 |\n| Generation reference defects vs. downstream evaluation images | 0 |\n\n\n## 2. Fixed-epoch downstream rerun, no checkpoint selection\n\nEvery downstream model is re-evaluated at the fixed final epoch (200), with the best-of-20 rule removed entirely. The protocol is otherwise unchanged and identical across methods: same 500 generated images per category, same architectures, same schedule.\n\n**Single-class (Table 1 metrics).**\n\n| Method | Acc-C best-of-20 → fixed | AP-P best-of-20 → fixed |\n|---|---|---|\n| AnoDiff | 68.4 → 67.1 | 75.4 → 74.2 |\n| AnoGen | 61.4 → 60.2 | 63.3 → 62.1 |\n| DualAnoDiff | 64.0 → 62.7 | 66.0 → 64.6 |\n| SeaS | 59.1 → 57.9 | 68.2 → 66.9 |\n| AnyDoor | 61.8 → 60.4 | 18.1 → 17.2 |\n| InsertAnything | 63.6 → 62.4 | 64.1 → 62.8 |\n| UniDG-SFT | 74.9 → 73.6 | 77.0 → 75.7 |\n| UniDG-RFT | 77.4 → 76.1 | 77.3 → 76.1 |\n\n**Multi-class (Table 2 metrics).**\n\n| Method | PRO-P best-of-20 → fixed | FG-mIoU best-of-20 → fixed |\n|---|---|---|\n| AnoDiff | 81.82 → 80.7 | 23.83 → 23.0 |\n| AnoGen | 79.54 → 78.4 | 26.45 → 25.6 |\n| DualAnoDiff | 79.96 → 78.8 | 26.27 → 25.4 |\n| SeaS | 81.01 → 79.9 | 20.48 → 19.7 |\n| AnyDoor | 79.10 → 78.0 | 11.11 → 10.5 |\n| InsertAnything | 77.45 → 76.3 | 15.63 → 14.8 |\n| UniDG-SFT | 90.98 → 89.9 | 28.52 → 27.6 |\n| UniDG-RFT | 91.12 → 90.1 | 31.87 → 30.9 |\n\nAs expected, removing the selection rule costs roughly one point of absolute performance for **every** method, and the ordering is unchanged : the UniDG-RFT margin over InsertAnything is 13.7 Acc-C and 16.1 FG-mIoU under the fixed protocol, against 13.8 and 16.24 under best-of-20 . The selection rule inflated absolute values uniformly rather than favouring us, which is what we said we expected and would rather have measured than argued.\n\nThe fixed-epoch protocol becomes primary in the final version, and the best-of-20 numbers move to an appendix with the rule stated in the caption.\n\nThese were the two items we owed this thread. If the overlap audit, the fixed-epoch protocol, or anything remaining under the ethics flag is still insufficient, we would rather be told precisely what is missing than guess, and we can still address it within the discussion period."
+ },
+ "createdAt": "2026-08-03T03:36:59.370Z",
+ "modifiedAt": "2026-11-19T17:14:33.039Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=PYgBrBOpoE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/qcootecv79.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/qcootecv79.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "QCOOtECV79",
+ "replyTo": "EBBnYHmjCR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you — that is a fair thing to hold us to, and our earlier answer declined a question we should have answered. Below is the smaller-backbone experiment, with the adjusted details named so you can judge whether the core components are held fixed, plus the mask-sensitivity sweep we promised in this thread.\n\n## 1. Smaller backbone\n\n**Why we hesitated.** UniDG's conditioning is bound to FLUX.1-Fill-dev at four points: the 384-channel masked-input stem, the frozen 4.7M Redux MLP projecting SigLIP features into the 4096-dim condition-token space, the 2-D RoPE that keeps the two halves of the diptych canvas positionally distinct, and Defect Attention's bias over joint-attention keys. Across backbone families all four must be rebuilt; within the FLUX family three survive untouched — exactly the setting that answers your question, and we should have gone there instead of stopping.\n\n**Backbone.** FLUX-Mini, 3.2B, distilled from FLUX.1-dev by reducing depth from 19+38 to 5+10 blocks. It retains hidden size 3072, condition dim 4096, the RoPE axis configuration, and the FLUX VAE.\n\n**The one adjusted detail.** FLUX-Mini is distilled from FLUX.1-dev, not from Fill, so its input projection takes 64 channels rather than 384. We widen it to 384 and zero-initialise the 320 new channels. This matters for reading the result: the 12B model *inherits* Fill's pretrained \"reproduce the unmasked region verbatim\" behaviour, whereas the 3.2B model must learn it during our SFT. Any gap is therefore an upper bound on the capacity cost, not a clean estimate of it.\n\n**Held fixed.** UDG data and the three-way sampling mixture; LoRA rank 256 on single- and double-stream blocks; Prodigy with bias correction, weight decay 0.01; batch 64 at 768 x 768; Normal Regularization (tau = 0.5); Defect Attention (alpha = 2.0); Adaptive Defect Crop and the diptych construction; and the downstream evaluation protocol including the 500-image budget.\n\n**Control.** The 12B backbone at the **same step budget** — no new run needed, Table 7 already reports it, and it avoids attributing a training-budget difference to capacity.\n\n| Backbone | Steps | PRO-P | mIoU | FG-mIoU | Cons | Qual |\n|---|---:|---:|---:|---:|---:|---:|\n| FLUX.1-Fill 12B (Table 7) | 2K | 77.2 | 27.0 | 11.0 | 3.03 | 3.10 |\n| FLUX-Mini 3.2B | 2K | 68.3 | 20.6 | 5.0 | 2.36 | 2.45 |\n| FLUX.1-Fill 12B (Table 7) | 6K | 80.1 | 29.1 | 13.3 | 3.44 | 3.57 |\n| FLUX-Mini 3.2B | 6K | 73.4 | 24.0 | 7.8 | 2.88 | 2.99 |\n\nThe 3.2B backbone retains 45% of FG-mIoU at 2K and 59% at 6K: the gap narrows with training, consistent with part of it being the missing Fill initialisation rather than a capacity ceiling. What matters against your question about backbone capacity is the shape of that curve. On the same 12B backbone, changing only the *formulation* (InsertAnything, same UDG data, Appendix M) retains 55% after Diversity-SFT and 57% after the full recipe — a gap that does not close with training. **The capacity cost shrinks as training proceeds; the formulation cost does not.** Neither budget is near convergence, so this bounds the ordering, not the converged gap; the 14K run goes into the camera-ready against Table 7's 14K row, reported whatever it shows.\n\n## 2. Mask sensitivity sweep, as promised\n\nInference on the MVTec-AD evaluation set with UniDG-RFT; target masks perturbed before generation; everything else fixed.\n\n| Target mask | FG-mIoU | RefAd |\n|---|---:|---:|\n| Unperturbed | 31.87 | 4.04 |\n| Dilate 3 / 7 / 11 px | 31.4 / 30.3 / 28.2 | 4.02 / 3.98 / 3.89 |\n| Erode 3 / 7 / 11 px | 30.5 / 28.1 / 24.6 | 3.99 / 3.91 / 3.72 |\n| Translate 5 / 10 px | 29.6 / 26.5 | 3.95 / 3.82 |\n\nThree readings. RefAd degrades far less than FG-mIoU, because mask geometry does not touch the reference stream — what erodes is localization, not defect appearance. Erosion hurts more than dilation, consistent with Adaptive Defect Crop already dilating the training mask with a 7x7 kernel for two iterations: the model is trained in the dilated regime and starved by the eroded one. And the worst setting, erosion by 11 px, still leaves FG-mIoU at 24.6 against InsertAnything's 15.63 with *unperturbed* masks — so downstream results are sensitive to mask quality, gradually rather than sharply, but not by enough to explain any comparison in the paper.\n\n## 3. Where this leaves the rest\n\nNothing here changes what we already conceded: Defect Attention is the weakest component (+0.6 Acc, +0.7 FG-mIoU), Consistency-RFT is optional alignment with a bounded benefit, and the UniDG-Text superiority claim is withdrawn. The smaller-backbone result was genuinely missing rather than merely buried, and we should have produced it in the first round.\n\nIf either table leaves something unresolved — backbone choice, matched-budget control, perturbation levels, or the earlier points on necessity and cross-domain scope — please say which, and we will answer within the discussion period."
+ },
+ "createdAt": "2026-08-03T08:00:51.220Z",
+ "modifiedAt": "2026-11-19T17:14:32.864Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=QCOOtECV79",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/qdq8asz5t2.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/qdq8asz5t2.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "qDq8ASz5t2",
+ "replyTo": "WPgUgtxDXZ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Continued (2/3): citation compliance and generation risk",
+ "comment": "Continuing our response (2 of 3). Two items follow from the provenance and licence account above: a compliance failure on our side, and a risk the review did not ask about but which belongs in the same answer.\n\n**A compliance failure we would rather report than quietly fix.** None of these datasets is currently cited in our bibliography. For BraTS, the CVC datasets, TN3K and Kvasir-SEG, citation is a stated condition of use rather than a courtesy, and BraTS names three specific manuscripts that must accompany any publication using it. Every source above will be cited — the three BraTS manuscripts in full, the reference papers each other provider names, and GoodsAD, which we also use and also failed to cite. The appendix will carry a per-source table pairing each dataset with its citation and the terms it is used under, so compliance is checkable in one place rather than inferred from the reference list.\n\n**One risk the reviewer did not ask about but which follows.** Our pipeline both synthesises abnormalities and removes them to produce a \"normal\" counterpart. On this data that means generating plausible synthetic brain tumours, polyps, retinal edema, liver lesions, thyroid nodules and skin lesions — and also plausible healthy scans that were never acquired from any patient. We now treat both as first-order rather than a footnote: no synthetic medical image is released, and the cards will state that generated medical abnormalities must not enter diagnostic-model training or clinical decision-making without specialist review, external validation, subgroup analysis and calibration assessment. Our one medical experiment, 120 Kvasir-SEG frames with a single lesion type, is a domain-shift probe, not evidence of clinical validity, and we are restating it that way in the main text.\n\n**Non-medical privacy.** Our industrial sources are object-centric photographs, but we have not verified that none incidentally contains a person. Before release we will sweep the published set with an off-the-shelf person and face detector, report the flagged count, and remove or redact any hit."
+ },
+ "createdAt": "2026-07-30T08:05:49.242Z",
+ "modifiedAt": "2026-11-19T17:14:33.386Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=qDq8ASz5t2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/qsd3aw3wzp.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/qsd3aw3wzp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "QsD3aw3WZp",
+ "replyTo": "razTByywDw",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to meta-review: index, corrections, and claim narrowing",
+ "comment": "Dear Area Chair,\n\nThank you for the initial meta-review — it identified the two items that would most change your assessment, and we organised our response around them. Since responses go in the individual reviewer threads, this note is only a short index plus two proactive disclosures.\n\n## 1. Where each meta-review point is answered\n\n| Meta-review item | Where |\n|---|---|\n| (d1) Data scale ablation at 50K/100K/200K/300K | JHNj §4, ruex §5, nT6U §6 — nested stratified subsets; since the default recipe traverses UDG exactly once at 14K steps, a fixed step count would confound data scale with over-training, so each size reports its best of 6K/10K/14K steps; single seed per size with that limitation stated |\n| (d2) Failure quantification, broken down by defect type | JHNj §3 and nT6U §6 — blinded two-annotator audit, both models scored on the same 365 inputs so the rates are paired, with the per-defect-type breakdown |\n| (c1) Failure cases not quantified | Same audit; it replaces the qualitative-only failure discussion |\n| (c2) Instruction-based editing only qualitatively supported | JHNj §7 — we are **withdrawing** the claim that UniDG-Text outperforms proprietary editing models |\n| (a) Diversity metrics not uniformly improved | nT6U §2 — we concede DualAnoDiff leads on IL (0.37 vs 0.28) and add KID plus IS, presenting realism and diversity as a trade-off. We also flag there that AnomalyDiffusion and DualAnoDiff deliberately decline to report FID/KID because overfitted per-category models score better on them, and that SeaS reports KID only for normal-image authenticity; we therefore expect the per-category baselines to lead on KID and say so before running it |\n\nOn the iteration-versus-data-size confusion specifically: Table 7 varies optimizer iterations, not unique dataset size. That was our presentation error and we separate the two axes explicitly in all three responses.\n\n## 2. A claim we are withdrawing unprompted\n\nNo reviewer raised it, but your point (c) is correct: Appendix C.3, in which UniDG-Text outperforms proprietary editing models, rests on selected qualitative examples with no quantitative benchmark, no systematic human evaluation, and incomplete hyperparameters. We are withdrawing the superiority claim rather than defending it. UniDG-Text will be presented as a qualitative demonstration that the formulation extends to instruction conditioning, with the full training configuration reported. It is not load-bearing for the paper's contribution.\n\n## 3. Two corrections we are making proactively\n\n**Transcription error in Table 16 (VisA classification).** The SeaS column duplicated its AUROC-I column. The correct per-category accuracies average **63.62**, not 84.67. UniDG-SFT and UniDG-RFT remain 90.01 and 91.16, and no UniDG result or conclusion is affected. This is disclosed in the nT6U thread as well.\n\n**Downstream checkpoint selection.** nT6U asked how the best downstream U-Net checkpoints are chosen, and we have put the full picture in that thread rather than only what the question required: the rule is best-of-20 on the sum of AUROC-I, AUROC-P, AP-P, and PRO-P, applied identically to every compared method, and Appendix G defines no validation split separate from the evaluation split — which is also the honest answer to that reviewer's question about validation images. What gets selected is the downstream evaluator rather than UniDG itself, and the uniform rule leaves the relative comparison intact, but it can inflate absolute values for every method. We are re-running the entire downstream evaluation at a fixed final epoch, with no selection at all, and have committed to posting that table in the nT6U thread within the discussion period. We expect absolute values to come down slightly for every method and the ranking to hold, but that is an expectation and we will report whatever the rerun gives, including a changed ranking. The fixed-epoch protocol becomes primary in the final version."
+ },
+ "createdAt": "2026-07-30T08:06:53.653Z",
+ "modifiedAt": "2026-11-19T17:14:33.799Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=QsD3aw3WZp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/raztbyywdw.json modified

+++ b/reviews/openreview/a3sobl3ciu/notes/raztbyywdw.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair 2TNc",
"content": {
- "metareview": "(a) Summary of Scientific Claims and Findings\nThe paper presents two primary contributions: the UDG dataset and the UniDG model, a unified framework for reference-based defect generation. The core scientific claim is that defect generation can be formulated as a Defect-Context Editing task, where a model learns transferable defect priors from diverse paired data and applies them to new objects/domains without per-category fine-tuning.\n\nThe authors propose a two-stage training strategy: Diversity-SFT (three complementary sampling distributions) followed by Consistency-RFT (GRPO-based reinforcement learning with two specialized reward models). Experimental results on MVTec-AD and VisA show that UniDG generally outperforms the evaluated few-shot anomaly generation and image insertion baselines on downstream detection/localization and MLLM-based perceptual metrics, although it does not uniformly improve all diversity-oriented synthesis metrics. Experiments on GoodsAD and Kvasir-SEG provide evidence of transfer to held-out natural and medical benchmarks without domain-specific fine-tuning. Post-training W4A4 quantization achieves a 3× speedup with small performance degradation.\n\n(b) Main Strengths\n1. Large-scale, systematically curated dataset (UDG).\nThe multi-agent curation pipeline (Inpainting, Captioner, Verifier) constructs 300K paired quadruplets with structured captions, including a curated real-anomaly subset and a verified synthetic extension. The dataset covers 28 standardized defect categories aggregated from 50 source datasets. This directly addresses the long-standing problem of paired defect-editing data scarcity.\n\n2. Novel two-stage training with strong ablation validation.\nDiversity-SFT uses three complementary sampling strategies (Single Object Fill, Intra-Defect Cross, Multi-Object Cross) to learn transferable priors. Consistency-RFT employs Flow-GRPO with Defect-Und-Reward and Defect-Recog-Reward to improve reference adherence. Ablations show incremental gains from each component, with Diversity-SFT contributing the largest improvement (+15.2 FG-mIoU vs. baseline). SFT is shown to be essential before RFT.\n\n3. Comprehensive evaluation across multiple benchmarks and metrics.\nEvaluation includes single-class AD (AUROC-I/P, AP-I/P, PRO-P), multi-class semantic segmentation (mIoU, FG-mIoU), MLLM-based synthesis quality scores, and transfer to GoodsAD and Kvasir-SEG. Per-category breakdowns are provided. A concept-level holdout (UDG_no-overlap) yields modest absolute drops across the four reported metrics (0.66-2.1 points), providing additional, though not conclusive, support for the transferable-prior claim.\n\n4. Practical deployment via W4A4 quantization.\nSVDQuant W4A4 retains the 12B-parameter architecture while reducing its reported BF16-equivalent model footprint from 12B to 3.3B, measured VRAM from 28GB to 9GB, and inference time from 11.59s to 3.9s, with small performance drops. This substantially improves the practicality of deployment on consumer GPUs.\nSupporting evidence: Appendix I, Table 18.\n\n(c) Main Weaknesses\n1. Failure cases not quantified.\nFailure modes (color drift, texture mismatch under extreme scale/lighting) are mentioned qualitatively with representative examples (Figure 9) but without systematic quantification or breakdown by defect type.\n\n2. Instruction-based editing is only qualitatively evaluated.\nAppendix C.3 describes two instruction-training distributions and presents qualitative comparisons in Figure 8. However, it does not report a quantitative benchmark, systematic human evaluation, or complete training hyperparameters. Consequently, the claim that UniDG-Text outperforms proprietary editing models is supported only by selected qualitative examples.\n\n(d) Weaknesses That Could Adjust Acceptance Odds (If Addressed)\nThe following clarifications or additional evidence could materially affect the assessment:\n1. Data scale ablation.\nWhat we need to see: Additional experiments varying UDG dataset size (50K, 100K, 200K, 300K) to clarify scaling behavior and whether the 300K scale is necessary.\n\n2. Quantification of failure cases.\nWhat we need to see: Systematic quantification of failure rates on evaluation benchmarks, ideally broken down by defect type, to help readers understand practical limitations."
+ "metareview": "(a) Summary of Scientific Claims and Findings\nThe paper presents two primary contributions: the UDG dataset and the UniDG model, a unified framework for reference-based defect generation. The core scientific claim is that defect generation can be formulated as a Defect-Context Editing task, where a model learns transferable defect priors from diverse paired data and applies them to new objects/domains without per-category fine-tuning.\n\nThe authors propose a two-stage training strategy: Diversity-SFT (three complementary sampling distributions) followed by Consistency-RFT (GRPO-based reinforcement learning with two specialized reward models). Experimental results on MVTec-AD and VisA show that UniDG generally outperforms the evaluated few-shot anomaly generation and image insertion baselines on downstream detection/localization and MLLM-based perceptual metrics, although it does not uniformly improve all diversity-oriented synthesis metrics. Experiments on GoodsAD and Kvasir-SEG provide evidence of transfer to held-out natural and medical benchmarks without domain-specific fine-tuning. Post-training W4A4 quantization achieves a 3× speedup with small performance degradation.\n\n(b) Main Strengths\n1. Large-scale, systematically curated dataset (UDG).\nThe multi-agent curation pipeline (Inpainting, Captioner, Verifier) constructs 300K paired quadruplets with structured captions, including a curated real-anomaly subset and a verified synthetic extension. The dataset covers 28 standardized defect categories aggregated from 50 source datasets. This directly addresses the long-standing problem of paired defect-editing data scarcity.\n\n2. Novel two-stage training with strong ablation validation.\nDiversity-SFT uses three complementary sampling strategies (Single Object Fill, Intra-Defect Cross, Multi-Object Cross) to learn transferable priors. Consistency-RFT employs Flow-GRPO with Defect-Und-Reward and Defect-Recog-Reward to improve reference adherence. Ablations show incremental gains from each component, with Diversity-SFT contributing the largest improvement (+15.2 FG-mIoU vs. baseline). SFT is shown to be essential before RFT.\n\n3. Comprehensive evaluation across multiple benchmarks and metrics.\nEvaluation includes single-class AD (AUROC-I/P, AP-I/P, PRO-P), multi-class semantic segmentation (mIoU, FG-mIoU), MLLM-based synthesis quality scores, and transfer to GoodsAD and Kvasir-SEG. Per-category breakdowns are provided. A concept-level holdout (UDG_no-overlap) yields modest absolute drops across the four reported metrics (0.66-2.1 points), providing additional, though not conclusive, support for the transferable-prior claim.\n\n4. Practical deployment via W4A4 quantization.\nSVDQuant W4A4 retains the 12B-parameter architecture while reducing its reported BF16-equivalent model footprint from 12B to 3.3B, measured VRAM from 28GB to 9GB, and inference time from 11.59s to 3.9s, with small performance drops. This substantially improves the practicality of deployment on consumer GPUs.\nSupporting evidence: Appendix I, Table 18.\n\n(c) Main Weaknesses\n1. Failure cases not quantified.\nFailure modes (color drift, texture mismatch under extreme scale/lighting) are mentioned qualitatively with representative examples (Figure 9) but without systematic quantification or breakdown by defect type.\n\n2. Instruction-based editing is only qualitatively evaluated.\nAppendix C.3 describes two instruction-training distributions and presents qualitative comparisons in Figure 8. However, it does not report a quantitative benchmark, systematic human evaluation, or complete training hyperparameters. Consequently, the claim that UniDG-Text outperforms proprietary editing models is supported only by selected qualitative examples.\n\n(d) Weaknesses That Could Adjust Acceptance Odds (If Addressed)\nThe following clarifications or additional evidence could materially affect the assessment:\n1. Data scale ablation.\nWhat we need to see: Additional experiments varying UDG dataset size (50K, 100K, 200K, 300K) to clarify scaling behavior and whether the 300K scale is necessary.\n\n2. Quantification of failure cases.\nWhat we need to see: Systematic quantification of failure rates on evaluation benchmarks, ideally broken down by defect type, to help readers understand practical limitations.",
+ "final_justification": "I have read the authors' response and have reached my final decision based on the following assessment.\n\nThe authors provided substantive responses to the two issues raised in the review—namely, data scale ablation and failure case quantification—and have corrected several claims that lacked factual support.\n\nMost commendable aspects of the authors' response:\n\n(1) Quantitative decomposition of component contributions and claim narrowing. The authors decomposed the gains in Table 3 into the contributions of five main components, directly addressing the concern that the pipeline is an overly long assembly of off-the-shelf modules. This decomposition clearly shows that the three components expressing the data formulation—Diptych Defect-Context Editing, Normal Regularization, and Diversity-SFT—account for 79% of the total FG-mIoU gain, while the borrowed components (Defect Attention and Consistency-RFT) contribute modestly.\n\n(2) Quantitative assessment of synthesis quality in the data curation pipeline. UDG's data construction relies entirely on an automated multi-agent pipeline without exhaustive per-sample human verification. To address this legitimate concern, the authors conducted an independent human audit—covering 500 stratified retained samples and approximately 5,000 boundary cases—and provided quantitative metrics (image/mask validity 96.4%, caption correctness 95.6%, 97.1% of recovered normals defect-free and artifact-free), thereby offering tangible guarantees of the data's synthesis quality.\n\nMy final recommendation is to accept this paper."
},
"createdAt": "2026-07-18T15:28:42.082Z",
- "modifiedAt": "2026-11-18T15:18:17.637Z",
+ "modifiedAt": "2026-11-19T04:59:02.844Z",
"url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=razTByywDw",
"license": "CC-BY-4.0"
}

reviews/openreview/a3sobl3ciu/notes/tl6hobizye.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/tl6hobizye.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "tl6hoBizye",
+ "replyTo": "A9EdNNtHrE",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you — you are right, and the framing we used was wrong. W4A4 lowers the numerical precision of a trained 12B function; it does not reduce capacity. We withdraw it as an answer to your question and answer the question you actually asked.\n\n## 1. What \"rebuilding that conditioning\" means, concretely\n\nUniDG's conditioning is four couplings to FLUX.1-Fill-dev / Redux-dev:\n\n1. **Masked-input stem.** The Fill DiT's input projection consumes 384 channels: the packed noisy latent, the packed masked-image latent, and the packed binary mask. Our diptych places the reference in the left half of one 2:1 canvas with mask = 0 there, and relies on Fill's *pretrained* behaviour of reproducing unmasked content verbatim. That inherited behaviour is what makes \"reference on the left, edit on the right\" work at all.\n2. **Reference stream.** Redux's Image Embedder is a frozen 4.7M MLP mapping SigLIP features into the DiT's 4096-dim condition-token space, sequence-concatenated into the text branch.\n3. **Diptych positions.** The two halves must stay positionally distinct under joint attention; FLUX's 2-D RoPE supplies that at a 2:1 aspect ratio without retraining.\n4. **Defect Attention.** A log-alpha bias on keys in the reference half and the target region, presuming MM-DiT joint attention over [image; condition] tokens with identifiable spatial indices.\n\nWhether these break depends on *which* 2–3B model, and we should have made that distinction instead of asserting a blanket cost:\n\n- **A different backbone family** (e.g. SD3.5-Medium 2.5B, Sana 1.6B) changes the VAE channel count and downsample factor, the condition-token width, and the text-encoder type, and in some cases replaces RoPE with learned position embeddings. All four couplings must be rebuilt, and (1) has no fill-pretrained initialisation to inherit.\n- **Within the FLUX family, far less breaks than we implied.** FLUX-Mini (3.2B, depth reduced from 19+38 to 5+10 blocks) keeps hidden size 3072, condition dim 4096, the RoPE axis configuration, and the FLUX VAE, so (2), (3) and (4) port unchanged. **Only (1) breaks**, and only because FLUX-Mini is distilled from FLUX.1-dev (in_channels = 64) rather than from Fill: the input projection must be widened 64 → 384 with the 320 new channels zero-initialised, after which mask conditioning is *learned* during our SFT instead of inherited.\n\nSo the honest version of the sentence you quoted is: across families it is a port; within the family it is one initialisation change plus retuning. Our real concern was never that this is research-hard, but that the resulting number *understates* the small backbone, because it must learn inpainting and defect editing from the same data the 12B model needs only for the second. We should have said that and let you weigh it, rather than declining.\n\n## 2. The experiment\n\nWe ran the in-family version to isolate capacity. Held fixed: UDG data and the three-way sampling mixture, LoRA rank 256, Prodigy, batch 64 at 768 x 768, Normal Regularization, Defect Attention, and the evaluation protocol. The only changes are the backbone and the widened stem.\n\nThe control needs no new run: Table 7 already reports the 12B backbone at every step budget, so we compare **at matched steps** rather than against the converged 14K model.\n\n| Backbone | Steps | PRO-P | mIoU | FG-mIoU | Cons | Qual |\n|---|---:|---:|---:|---:|---:|---:|\n| FLUX.1-Fill 12B (Table 7) | 2K | 77.2 | 27.0 | 11.0 | 3.03 | 3.10 |\n| FLUX-Mini 3.2B | 2K | 68.3 | 20.6 | 5.0 | 2.36 | 2.45 |\n| FLUX.1-Fill 12B (Table 7) | 6K | 80.1 | 29.1 | 13.3 | 3.44 | 3.57 |\n| FLUX-Mini 3.2B | 6K | 73.4 | 24.0 | 7.8 | 2.88 | 2.99 |\n\nThe 3.2B backbone retains 45% of FG-mIoU at 2K and 59% at 6K: the gap *narrows* with training, consistent with part of it being the missing Fill initialisation rather than a capacity ceiling. On the same 12B backbone, changing only the *formulation* (InsertAnything, same UDG data, Appendix M) retains 55% after Diversity-SFT and 57% after the full recipe — a gap that does not close with training. **The capacity cost shrinks as training proceeds; the formulation cost does not.**\n\n**What this does not show.** 6K steps is well short of convergence, so this bounds the ordering, not the converged gap. We are running the 3.2B model to the full 14K budget and will report it in the camera-ready against Table 7's 14K row, whatever it shows — including a gap large enough to narrow the paper's claim to the evaluated scale.\n\nWe are grateful you pushed on this. It replaced a refusal with a measurement, and the measurement is one the paper should have contained.\n\nIf any of this is still unconvincing — the backbone choice, the matched-budget protocol, or the earlier glossary and caption fixes — please name it; there is still time in the discussion period to answer."
+ },
+ "createdAt": "2026-08-03T08:03:44.958Z",
+ "modifiedAt": "2026-11-19T17:14:32.880Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=tl6hoBizye",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/uuv1wxsxw5.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/uuv1wxsxw5.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "uUv1wXSxw5",
+ "replyTo": "QsD3aw3WZp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Continued (2/2): ethics-thread corrections and claim narrowing",
+ "comment": "Dear Area Chair, continuing the note above (2 of 2). The two items below came out of the ethics threads rather than the meta-review, and we would rather you saw them here than discovered them across three separate discussions.\n\n## 4. Ethics threads: two further corrections\n\nThe three ethics reviews prompted checks that turned up two errors in the submission. Both are documentation rather than results, no experimental claim depends on either, and we have answered each ethics reviewer in full — but you should see them in one place.\n\n**The medical sources were never documented.** Reviewers adin and CMZU both asked for the provenance, consent basis and de-identification status of UDG's medical imagery. The paper claims medical scope and names not one medical source, so nothing in the submission lets anyone check. They are BraTS 2018/19/20, ISIC, CVC-ClinicDB, CVC-ColonDB, EndoScene, TN3K, RESC and liver imaging from BTCV+LiTS and ATLAS, with Kvasir-SEG evaluation-only. We give a per-source table in the CMZU thread covering all four fields requested, and state plainly what we cannot verify: we hold no patient-level consent documentation for any source, and for ISIC the only de-identification guarantee is a contributor warranty the archive does not verify.\n\n**Neither the medical subset nor the weights can be MIT-licensed.** Appendix A commits to releasing dataset, weights and code under MIT. Several medical sources are CC BY-NC-SA 4.0, whose ShareAlike term binds derivatives, and CVC and Kvasir-SEG forbid commercial use, so the quadruplets built from them cannot be MIT. Separately, UniDG is a set of adapters on FLUX.1-Fill-dev and FLUX.1-Redux-dev, whose licence defines a Derivative to include any fine-tuned version and extends its non-commercial restriction to Derivatives, so the weights must carry the FLUX.1 [dev] Non-Commercial License. We will redistribute no medical image, derived quadruplet or synthetic medical image. What ships is per-sample metadata — source identifier and the mask, caption and generation parameters needed to rebuild the sample — plus the curation scripts, so the subset can be reconstructed by anyone who accepts each provider's terms directly. That is the mechanism the paper already describes for restricted industrial sources; we failed to apply it where it mattered most.\n\n**A live compliance failure.** None of the medical sources, nor Kvasir-SEG, nor GoodsAD, is currently cited. For BraTS, the CVC datasets, TN3K and Kvasir-SEG citation is a stated condition of use, and BraTS names three specific manuscripts. All will be cited in the camera-ready, alongside a per-source appendix table pairing each dataset with its citation and its terms of use, so compliance is checkable in one place. We report this rather than fix it silently because it bears on whether our asset documentation can be trusted.\n\nEthics reviewer ZhqZ recommends renaming the method, judging \"Universal\" unsupported. We agree and propose \"UniDG: **Unified** Defect Generation via Defect-Context Editing\", which keeps the acronym and every existing reference to the method while dropping the coverage claim. We would need your and the program chairs' approval for a camera-ready title change and would welcome your view.\n\n## 5. Claims we are narrowing\n\n\"Domain-agnostic\" becomes transfer to the evaluated held-out benchmarks without target-benchmark or category-specific fine-tuning. \"Training-Free Few-Shot\" becomes no target-benchmark training, since UniDG is trained on UDG. Consistency-RFT is described as an optional alignment stage with a measured, bounded benefit rather than a necessary one, and Defect Attention is reported as the weakest component at +0.6 Acc and +0.7 FG-mIoU. We would rather state the supported scope precisely than defend the broader wording.\n\nWe are happy to provide anonymized code in an Official Comment if that would help the committee assess the data manifest or the evaluation protocol."
+ },
+ "createdAt": "2026-07-30T08:07:24.773Z",
+ "modifiedAt": "2026-11-19T17:14:33.039Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=uUv1wXSxw5",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/a3sobl3ciu/notes/wpgugtxdxz.json added

+++ b/reviews/openreview/a3sobl3ciu/notes/wpgugtxdxz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "WPgUgtxDXZ",
+ "replyTo": "rejvPeyNAl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response: medical sources and release plan",
+ "comment": "We thank the ethics reviewer for both points. The medical question comes first, because the reviewer has identified a genuine gap: our paper claims medical scope and never names a single medical source, so nothing in the submission lets anyone check provenance, consent, or de-identification. Here is the full account.\n\n## 1. Medical images: sourcing, consent, de-identification\n\n**The sources.** UDG's medical portion is drawn entirely from established public research datasets: BraTS 2018, 2019 and 2020 (brain MRI); ISIC (dermoscopy); CVC-ClinicDB, CVC-ColonDB and EndoScene (colonoscopy); TN3K (thyroid ultrasound); RESC (retinal OCT); and liver CT/MRI from BTCV+LiTS and ATLAS, the OCT and liver splits reached through the BMAD anomaly-detection reorganisation. Kvasir-SEG (colonoscopy) is used only as a held-out evaluation set and contributes nothing to training. None of these appears in the submission by name, which is the actual failure the review is pointing at, and all of them will be listed with a domain label in the per-source table.\n\n**Consent and ethics review sit upstream, and the documentation varies.** ATLAS was anonymised under the rules of its hospital's ethics committee, which under French law did not require an approval number. LiTS states that all seven contributing sites agreed to public release and that ethics approval was not required. BraTS is distributed under a data usage agreement built on HIPAA de-identification, with re-identification and any reconstruction of face, head or body prohibited. The CVC datasets come from a hospital endoscopy unit via its research group, with images remaining the property of the hospital. For none of them did we receive patient-level consent documentation, and we will not imply we verified it. What we can state is that each was released for research reuse by the institution that collected it, and that we took the data through the access route its providers specify.\n\n**De-identification is mostly a property of the imaging rather than a promise from us.** Endoscopy and colonoscopy frames show the intestinal lumen. OCT gives retinal cross-sections. The BraTS volumes are distributed skull-stripped and template-registered, which removes precisely the facial surface that makes head MRI re-identifiable. The liver data are abdominal, with no head in the field of view, and LiTS states its scans were visually reviewed to preclude personal identifiers. TN3K's ultrasound frames were converted to grayscale with the non-ultrasound screen region cropped away — which is exactly where scanner software burns in patient banners.\n\nISIC is the one case where we rely on a warranty rather than on anatomy, and we would rather name it than smooth it over: dermoscopic close-ups could in principle include a tattoo or other distinguishing mark, contributors warrant that uploads contain no protected health information, and the archive states plainly that it does not independently verify this. We will describe it in those terms rather than assert that the images are de-identified.\n\n**This changes our release plan, which the paper gets wrong.** Several of these sources are CC BY-NC-SA 4.0, whose ShareAlike term requires derivative works to carry the same licence; the CVC datasets and Kvasir-SEG restrict use to research and education and forbid commercial use. Our quadruplets are derivatives of these images, so the blanket MIT release announced in Appendix A is not available for them. We are therefore **not redistributing medical images, the quadruplets built from them, the masks or captions derived from them, or any synthetic medical image**. That is a decision, not a preference.\n\nWhat ships instead, so that the alternative is reproducible rather than a way of avoiding the question: for each medical quadruplet, a record giving the source dataset, the original image identifier within it, and the mask, caption and generation parameters needed to rebuild the quadruplet from the original — together with the curation scripts that consume those records. Anyone who obtains the source data directly, on each provider's own terms, can reconstruct the medical subset exactly. Nobody receives medical pixels from us. The paper already describes this mechanism for restricted industrial sources; we simply failed to apply it where it mattered most."
+ },
+ "createdAt": "2026-07-30T08:05:23.841Z",
+ "modifiedAt": "2026-11-19T17:14:33.480Z",
+ "url": "https://openreview.net/forum?id=A3soBL3Ciu&noteId=WPgUgtxDXZ",
+ "license": "CC-BY-4.0"
+}