PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:33 UTC · 0c55377caee5 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,33 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "iOvXn5DzBr"- }- ],- "title": "PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation",- "authors": [- "Xiaoda Wang",- "Minxiao Wang",- "Kaiqiao Han",- "Defu Cao",- "Ching Chang",- "Yidan Shi",- "Runze Yan",- "Xiao Luo",- "Yan Liu",- "Xiao Hu",- "Yizhou Sun",- "Wei Wang",- "Carl Yang"- ],- "abstract": "Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "2857b392-fedd-4fe9-b9bb-eb2ff2a9ab9b"}
paper.json added
+++ b/paper.json@@ -0,0 +1,23 @@+{+ "title": "PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation",+ "authors": [+ "Xiaoda Wang",+ "Minxiao Wang",+ "Kaiqiao Han",+ "Defu Cao",+ "Ching Chang",+ "Yidan Shi",+ "Runze Yan",+ "Xiao Luo",+ "Yan Liu",+ "Xiao Hu",+ "Yizhou Sun",+ "Wei Wang",+ "Carl Yang"+ ],+ "abstract": "Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}