potentialpaper

PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation

Update NeurIPS 2026 submission iOvXn5DzBr: 14 notes

@openreview[bot] · 2026-11-24 15:54 UTC · 2ec8c7f4a19e ·

Evidence

reviews/openreview/iovxn5dzbr/notes/31syzn80ga.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/31syzn80ga.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "31syzN80gA",
+ "replyTo": "Goapr4CkoH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "> **L2: Diversity of sensor modalities: The impact of different PPG sensor modalities is not adequately considered. For example, reflected PPG and transmitted PPG, or smartwatch-type sensors and fingertip clip-type sensors, can exhibit substantially different waveform characteristics. It would be helpful for the authors to discuss how such differences may affect the proposed method and whether additional adaptation or calibration would be required.**\n\n\nWe thank the reviewer for highlighting this limitation. To evaluate sensor-modality shift, we additionally conduct zero-shot evaluation on the poor-quality subset of BUT PPG, where PPG is derived from smartphone-camera video at 30 Hz rather than the clinical bedside PPG at 40 Hz used for training.\n\n**Table R13: Zero-shot performance under sensor-modality and signal-quality shifts.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.8506 | 1.4142 | 117.08 | 56.33 | 19.01 |\n| CardioGAN | 0.9738 | 1.4147 | 121.56 | 58.39 | 27.32 |\n| CardioFlow | 0.6720 | 1.1197 | 74.60 | 72.87 | 18.95 |\n| PPGFlowECG | 0.6449 | 1.0628 | 71.85 | 70.10 | 25.99 |\n| PG-LRF | **0.6403** | **1.0253** | **14.06** | **31.51** | **14.49** |\n\n\nPG-LRF achieves the best performance on all five metrics despite changes in sensing modality, sampling rate, and signal quality, providing evidence of improved cross-device robustness. Nevertheless, smartphone-camera PPG does not cover all possible sensor types, and deployment on unseen smartwatch, fingertip, or transmissive PPG sensors may still require lightweight calibration or domain adaptation. We will clarify this limitation in the revised manuscript.\n\n\n\n\n> **F1: There is a missing equation number (Eq.(??)) in the list of equations in Appendix B.2 (p. 15).**\n\nWe thank the reviewer for catching this. The broken reference should point to Eq. 36. We have corrected it in the revised manuscript."
+ },
+ "createdAt": "2026-07-30T18:06:15.526Z",
+ "modifiedAt": "2026-11-19T16:52:18.794Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=31syzN80gA",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/7hr9cd5ajb.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/7hr9cd5ajb.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "7Hr9CD5AJb",
+ "replyTo": "Goapr4CkoH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "> **W2: Limitations of generalizability due to evaluation using a single dataset: This paper is subject to limitations in terms of generalizability, which are attributable to the evaluation of a single dataset. As stated in Appendix E, the evaluation is constrained exclusively to MC-MED (Stanford-affiliated emergency department, 2020–2022). However, there is a paucity of evidence regarding the generalizability of these findings to different institutions, patient populations, or sensor devices. Further validation on public datasets, such as BIDMC, is necessary, along with a discussion of the applicability of these methods to data from other institutions.**\n> **Q3: Generalization to other datasets: Do the authors have any preliminary results on datasets other than MC-MED, such as BIDMC or MIMIC-III waveform data? If not, how robust do the authors expect the trained model to be against differences in PPG sensor characteristics and sampling rates across datasets?**\n\nWe thank the reviewer for raising this important concern. To directly assess cross-dataset generalization, we evaluate PG-LRF and all baseline models on three external datasets—VitalDB, MIMIC-AFib, and BIDMC—without any fine-tuning or target-domain calibration. These datasets differ from MC-MED in clinical setting, patient population, sensor configuration, and sampling rate.\n\n**Table R8: Performance on VitalDB.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.7675 | 1.4144 | 106.41 | 59.64 | 10.86 |\n| CardioGAN | 0.8198 | 1.4109 | 92.87 | 59.39 | **9.17** |\n| CardioFlow | 0.6248 | 1.3492 | 44.16 | 36.62 | 16.40 |\n| PPGFlowECG | 0.6188 | 1.3074 | 73.43 | 72.18 | 13.30 |\n| PG-LRF | **0.6074** | **1.3006** | **40.64** | **31.11** | 10.49 |\n\n**Table R9: Performance on MIMIC-AFib.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.9969 | 1.3945 | 118.21 | 69.35 | 11.97 |\n| CardioGAN | 1.0308 | 1.4130 | 61.39 | 67.62 | 12.68 |\n| CardioFlow | 0.5422 | 0.8663 | 11.96 | 45.17 | 14.54 |\n| PPGFlowECG | 0.5219 | 0.8429 | 14.13 | 70.96 | 12.81 |\n| PG-LRF | **0.5178** | **0.8377** | **11.30** | **25.09** | **10.41** |\n\n**Table R10: Performance on BIDMC.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.9742 | 1.3215 | 841.56 | 55.37 | 3.48 |\n| CardioGAN | 1.0245 | 1.4268 | 449.03 | 62.66 | 4.35 |\n| CardioFlow | 0.5186 |0.8522 | 88.39 | 20.58 | 6.83 |\n| PPGFlowECG | **0.4945** | 0.8389 | 79.50 | 82.15 | 6.54 |\n| PG-LRF | 0.4978 | **0.8279** | **76.78** | **19.34** | **3.47** |\n\nAcross the three datasets, PG-LRF achieves the best result on 13 of 15 dataset–metric combinations, including RMSE and FID on all three and every metric on MIMIC-AFib. The advantage is most consistent on distributional metrics, indicating that the physiological simulator guidance transfers across institutions, patient populations, and acquisition setups without any fine-tuning. Overall, these results indicate that the benefits of PG-LRF are not specific to MC-MED.\n\n> **W3: Insufficient verification of baseline implementation reproducibility and fairness: Adequate verification of baseline implementation reproducibility and fairness is lacking. All four baselines (CardioFlow, RDDM, CardioGAN, PPGFlowECG) have been adapted to the MC-MED setting, which differs from their original proposal settings (e.g., dataset, sampling rate). However, the absence of details regarding the adaptation process, such as the performance of hyperparameter tuning and the utilization of official implementations, hinders the ability to verify the accurate capture of baseline performance.**\n\nWe thank the reviewer for this question. All baselines are evaluated using their official implementations, released pretrained checkpoints, and recommended configurations, without retraining or dataset-specific hyperparameter tuning. Each baseline retains its official input preprocessing and normalization to avoid distribution mismatch with its pretrained checkpoint.\nThe only adaptation is deterministic resampling to match each model’s required input and output sampling rates. For evaluation, all generated ECGs and reference signals are converted to the same 120 Hz, 10-second format and processed using an identical post-generation normalization and metric implementation. All methods are evaluated on the same MC-MED test segments using single-sample generation, with (T=10) for all step-based methods. No test-set tuning or method-specific evaluation adjustment is performed."
+ },
+ "createdAt": "2026-07-30T18:03:23.510Z",
+ "modifiedAt": "2026-11-19T16:52:18.547Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=7Hr9CD5AJb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/dcsvvazlvs.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/dcsvvazlvs.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "DCSvvAzlVS",
+ "replyTo": "FOm4z2wjyQ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "> **Q1: How does the model perform to generate correct ECG from noisy PPG as PPG quality varies substantially?**\n\nWe thank the reviewer for this important question. To evaluate robustness under realistic PPG degradation, we conduct zero-shot evaluation on the poor-quality subset of BUT PPG, which contains smartphone-camera PPG recorded at 30 Hz with real-world noise caused by motion, sensor placement, and illumination.\n\n**Table R5: Zero-shot evaluation on the poor-quality subset of BUT PPG.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.8506 | 1.4142 | 117.08 | 56.33 | 19.01 |\n| CardioGAN | 0.9738 | 1.4147 | 121.56 | 58.39 | 27.32 |\n| CardioFlow | 0.6720 | 1.1197 | 74.60 | 72.87 | 18.95 |\n| PPGFlowECG | 0.6449 | 1.0628 | 71.85 | 70.10 | 25.99 |\n| PG-LRF | **0.6403** | **1.0253** | **14.06** | **31.51** | **14.49** |\n\nPG-LRF achieves the best performance on all five metrics, with particularly large improvements in FD and FID. These results demonstrate its robustness to noisy PPG and substantial shifts in sensing modality, sampling rate, and signal quality.\n\n> **Q2: Does the model outperform other baseline in visualization quality as well?**\n\nWe thank the reviewer for this question. We conducted a side-by-side qualitative comparison using identical PPG inputs for all methods. Although figures cannot be included in the rebuttal, the visual observations are consistent with the morphology-specific metrics in Table 2, which are designed to quantify visually salient ECG characteristics, including P-wave, QRS-complex, and T-wave morphology.\nSpecifically, baseline outputs tend to produce attenuated or oversmoothed P and T waves, consistent with their larger P- and T-duration errors (PPGFlowECG: 28.8 ms and 37.7 ms; PG-LRF: 19.3 ms and 21.3 ms). PG-LRF also generates sharper QRS complexes, consistent with its lower QRS-duration error (38.6 ms versus 48.1 ms for PPGFlowECG). In addition, PG-LRF exhibits less beat-timing drift, consistent with its lower HR MAE in Table 1.\nPG-LRF further achieves the best FD and FID, supporting improved distribution-level waveform realism. We will include representative qualitative comparisons in the revised manuscript."
+ },
+ "createdAt": "2026-07-30T18:01:18.210Z",
+ "modifiedAt": "2026-11-19T16:52:18.653Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=DCSvvAzlVS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/erbk50ulvp.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/erbk50ulvp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "eRBK50uLvp",
+ "replyTo": "Goapr4CkoH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer dFeY,\n\nWe kindly wanted to follow up and ask whether our rebuttal has addressed your main concerns. If there are no remaining issues, we would greatly appreciate your reconsideration of the overall rating.\n\nThanks,\n\nAuthors"
+ },
+ "createdAt": "2026-08-03T10:02:13.214Z",
+ "modifiedAt": "2026-11-19T16:52:18.305Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=eRBK50uLvp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/fvwrnarpg7.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/fvwrnarpg7.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "FvwrnaRpG7",
+ "replyTo": "FOm4z2wjyQ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank you for your thoughtful and constructive feedback. We have carefully considered your comments and addressed each concern individually in our point-by-point responses.\n\n> **W1:The evaluation is limited to only one dataset. Additional experiments on other publicly available dataset will give a more generalized result of the proposed framework. It will also give a clear idea whether the framework can beat all the baselines on different dataset. Other available dataset are : MIMIC-AFib [1] , VitalDB [2] , BIDMC [3].**\n> **W3: The paper also lacks a zero shot generalization experiment. For example, the model is trained on one dataset (let’s say MCMED) and evaluated on another dataset (MIMIC-AFib) without fine-tuning. This will give stronger proof of its robustness.**\n\nWe thank the reviewer for these suggestions. Following the recommendation, we evaluate on all three suggested datasets — VitalDB, MIMIC-AFib, and BIDMC — under a strict zero-shot protocol: all models are evaluated directly on each external dataset without any fine-tuning. All methods use identical preprocessing. \n\n**Table R1: Performance on VitalDB.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.7675 | 1.4144 | 106.41 | 59.64 | 10.86 |\n| CardioGAN | 0.8198 | 1.4109 | 92.87 | 59.39 | **9.17** |\n| CardioFlow | 0.6248 | 1.3492 | 44.16 | 36.62 | 16.40 |\n| PPGFlowECG | 0.6188 | 1.3074 | 73.43 | 72.18 | 13.30 |\n| PG-LRF | **0.6074** | **1.3006** | **40.64** | **31.11** | 10.49 |\n\n**Table R2: Performance on MIMIC-AFib.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.9969 | 1.3945 | 118.21 | 69.35 | 11.97 |\n| CardioGAN | 1.0308 | 1.4130 | 61.39 | 67.62 | 12.68 |\n| CardioFlow | 0.5422 | 0.8663 | 11.96 | 45.17 | 14.54 |\n| PPGFlowECG | 0.5219 | 0.8429 | 14.13 | 70.96 | 12.81 |\n| PG-LRF | **0.5178** | **0.8377** | **11.30** | **25.09** | **10.41** |\n\n**Table R3: Performance on BIDMC.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.9742 | 1.3215 | 841.56 | 55.37 | 3.48 |\n| CardioGAN | 1.0245 | 1.4268 | 449.03 | 62.66 | 4.35 |\n| CardioFlow | 0.5186 |0.8522 | 88.39 | 20.58 | 6.83 |\n| PPGFlowECG | **0.4945** | 0.8389 | 79.50 | 82.15 | 6.54 |\n| PG-LRF | 0.4978 | **0.8279** | **76.78** | **19.34** | **3.47** |\n\nAcross the three datasets, PG-LRF achieves the best result on 13 of 15 dataset–metric combinations, including RMSE and FID on all three and every metric on MIMIC-AFib. The advantage is most consistent on distributional metrics, indicating that the physiological simulator guidance transfers across institutions, patient populations, and acquisition setups without any fine-tuning. Overall, these results indicate that the benefits of PG-LRF are not specific to MC-MED.\n\n\n\n\n> **W2: The effect of the number of sampling steps is not evaluated. There is no discussion about whether the same sampling steps are taken for all the baseline models or not. For example, PGFlowECG [4] achieves its best performance at T = 5.**\n\nWe thank the reviewer for this valuable suggestion. We had conducted the sampling-step ablation: \n\n**Table R4: Effect of sampling steps T on PG-LRF (MC-MED).**\n\n| T (steps) | MAE ↓ | RMSE ↓ |\n| --------: | ----: | -----: |\n| 5 | **0.66** | **1.02** |\n| 10 | 0.71 | 1.07 |\n| 15 | 0.73 | 1.09 |\n| 20 | 0.74 | 1.10 |\n\nOur finding is consistent with PPGFlowECG, as PG-LRF also achieves its best performance at (T=5). For a fair comparison, all step-based methods in Tables 1 and 2 are evaluated using a uniform (T=10), without method-specific tuning of the sampling steps.\n\n\n> **W4: There is also no discussion about how these values (λ_ecg = 5.0, λ_ppg = 0.25, λ_deriv = 3.0, and λ_peak = 12.0) are chosen.**\n\nWe thank the reviewer for this valuable comment. We selected the final values through a coarse search on a held-out validation subset, based on simulator consistency and ECG generation quality. These weights account for both the numerical scales and physiological roles of the four loss terms. Specifically, L_ecg and L_ppg operate on full waveforms, whereas L_deriv and L_peak focus on temporal variations and localized cardiac events and therefore require larger weights to contribute comparably during optimization. Moreover, L_ecg is assigned a larger weight because it constrains the upstream electrical source, while L_ppg is downweighted because PPG is an indirect measurement affected by pulse transit time, vascular compliance, and sensor conditions."
+ },
+ "createdAt": "2026-07-30T18:00:29.292Z",
+ "modifiedAt": "2026-11-19T16:52:18.651Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=FvwrnaRpG7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/gcf8wlzegf.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/gcf8wlzegf.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "gCF8wLZEgf",
+ "replyTo": "Goapr4CkoH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank you for your thoughtful and constructive feedback. We have carefully considered your comments and addressed each concern individually in our point-by-point responses.\n\n> **W1:Unverified details regarding the training of the ECG-to-PPG forward mapper and its impact on performance: A paucity of verification regarding the training details and the impact on performance of the ECG-to-PPG forward mapper is observed. Despite the fact that G_p is frozen post-pre-training, the quality of said pre-training (i.e., the extent of waveform error) directly impacts the accuracy of the simulator-induced loss, as delineated in Equation (26). In the event that the mapper is found to be inaccurate, the regularization effect on ECG→PPG hemodynamic consistency may be weakened or distorted. However, it is important to note that the performance of the mapper is not evaluated in isolation.**\n> **Q2: Quality evaluation of the ECG-to-PPG forward mapper: Please provide a quantitative evaluation of the pretrained ECG-to-PPG forward mapper G_p, such as PPG waveform reconstruction error. In addition, have the authors investigated how the effect of L_sim in Eq. (26) changes when the mapper is intentionally weakened? Such an ablation study would help clarify the dependence of the proposed method on the quality of the forward mapper.**\n\nWe thank the reviewer for this well-taken point. We agree that the quality of the frozen forward mapper G_p affects the reliability of L_sim, and we now evaluate it independently. G_p is a lightweight latent flow-matching model trained on paired ECG--PPG data from the MC-MED training split, with the physiology-aware autoencoder frozen. \n\n**Table R6: Standalone evaluation of G_p.**\n\n| MAE ↓ | RMSE ↓ | Pearson \\(r\\) ↑ | Lag-tolerant \\(r\\) ↑ | Pulse-rate MAE ↓ | Pulse-rate \\(r\\) ↑ | Within ±5/±10 bpm ↑ |\n| ---: | ---: | ---: | ---: | ---: | ---: | ---: |\n| 0.214 | 0.266 | 0.405 | 0.596 | 5.12 | 0.741 | 63.1% / 84.5% | \n\nThese results show that G_p preserves waveform morphology, frequency content, and pulse rate, which are the primary properties used by the simulator consistency loss. To evaluate sensitivity to mapper approximation quality, we reduce the numerical integration of G_p from 10 to 3 Euler steps. We then retrain PG-LRF using this weakened mapper while keeping all other training settings fixed.\n\n**Table R7: Sensitivity of PG-LRF to the approximation quality of the ECG-to-PPG forward mapper.**\n\n| \\(G_p\\) sampling steps | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| ---: | ---: | ---: | ---: | ---: | ---: |\n| 10 | **0.710** | **1.070** | **39.68** | **37.79** | **3.94** |\n| 3 | 0.714 | 1.071 | 41.00 | 38.87 | 4.04 |\n\nThe downstream performance changes only slightly, suggesting that PG-LRF is not highly sensitive to moderate approximation errors in G_p. This is because G_p provides only a frozen auxiliary training-time constraint, while the rectified-flow objective remains the primary learning signal. G_p is not used during inference."
+ },
+ "createdAt": "2026-07-30T18:02:26.160Z",
+ "modifiedAt": "2026-11-19T16:52:18.592Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=gCF8wLZEgf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/ips9isbedm.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/ips9isbedm.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "IPS9iSBEDm",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "General Response to All",
+ "comment": "We sincerely thank all reviewers for their thoughtful, encouraging, and constructive feedback. We are grateful that the reviewers recognized PG-LRF as “a novel method to integrate an electro hemodynamic simulator with latent rectified flow” and appreciated its “Clarity of Physiological Rationale,” “Ensuring Practicality Through Training-Inference Asymmetry,” and “Multifaceted Evaluation and Large-Scale Data.” We also appreciate the reviewers’ positive comments that the paper is “well written and easy to follow,” that “the figures are clear and visually appealing,” and that “the experimental details were clear and seem to be reproducible.” Moreover, reviewers noted that our evaluation “outperforms other baseline methods” and appreciated the “ablation study on their loss components.”\n\nWe have carefully considered all reviewer comments and addressed each concern in our point-by-point responses, including cross-dataset generalization, ECG-to-PPG mapper quality, robustness to noisy PPG and rare ICD groups, sampling-step efficiency, baseline implementation fairness, hyperparameter selection, normalization strategies, and qualitative failure cases. We provide additional analyses and clarifications wherever possible and will incorporate them into the revised manuscript. We sincerely thank the reviewers again for their valuable feedback, which has helped us further strengthen the paper."
+ },
+ "createdAt": "2026-07-30T17:57:27.263Z",
+ "modifiedAt": "2026-11-19T16:52:18.727Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=IPS9iSBEDm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/njgjdldif6.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/njgjdldif6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "NJgJdldif6",
+ "replyTo": "FOm4z2wjyQ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer SNin,\n\nWe kindly wanted to follow up and ask whether our rebuttal has addressed your main concerns. If there are no remaining issues, we would greatly appreciate your reconsideration of the overall rating.\n\nThanks,\n\nAuthors"
+ },
+ "createdAt": "2026-08-03T10:02:40.740Z",
+ "modifiedAt": "2026-11-19T16:52:18.279Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=NJgJdldif6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/npgd8fnwe6.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/npgd8fnwe6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "npGd8fNWE6",
+ "replyTo": "SInOCvX0tc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank you for your thoughtful and constructive feedback. We greatly appreciate your positive assessment of our paper, as well as your helpful suggestions for strengthening it. We have carefully considered your comments and addressed each concern individually in our point-by-point responses.\n\n> **W1: Evaluated solely on one dataset. I think this is the biggest weakness. Showing generation/classification performance on one more dataset would be a huge strength to this paper.**\n\nWe thank the reviewer for raising this important concern. To directly assess cross-dataset generalization, we evaluate PG-LRF and all baseline models on three external datasets—VitalDB, MIMIC-AFib, and BIDMC—without any fine-tuning or target-domain calibration. These datasets differ from MC-MED in clinical setting, patient population, sensor configuration, and sampling rate.\n\n**Table R14: Performance on VitalDB.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.7675 | 1.4144 | 106.41 | 59.64 | 10.86 |\n| CardioGAN | 0.8198 | 1.4109 | 92.87 | 59.39 | **9.17** |\n| CardioFlow | 0.6248 | 1.3492 | 44.16 | 36.62 | 16.40 |\n| PPGFlowECG | 0.6188 | 1.3074 | 73.43 | 72.18 | 13.30 |\n| PG-LRF | **0.6074** | **1.3006** | **40.64** | **31.11** | 10.49 |\n\n**Table R15: Performance on MIMIC-AFib.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.9969 | 1.3945 | 118.21 | 69.35 | 11.97 |\n| CardioGAN | 1.0308 | 1.4130 | 61.39 | 67.62 | 12.68 |\n| CardioFlow | 0.5422 | 0.8663 | 11.96 | 45.17 | 14.54 |\n| PPGFlowECG | 0.5219 | 0.8429 | 14.13 | 70.96 | 12.81 |\n| PG-LRF | **0.5178** | **0.8377** | **11.30** | **25.09** | **10.41** |\n\n**Table R16: Performance on BIDMC.**\n\n| Method | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: |\n| RDDM | 0.9742 | 1.3215 | 841.56 | 55.37 | 3.48 |\n| CardioGAN | 1.0245 | 1.4268 | 449.03 | 62.66 | 4.35 |\n| CardioFlow | 0.5186 |0.8522 | 88.39 | 20.58 | 6.83 |\n| PPGFlowECG | **0.4945** | 0.8389 | 79.50 | 82.15 | 6.54 |\n| PG-LRF | 0.4978 | **0.8279** | **76.78** | **19.34** | **3.47** |\n\nAcross the three datasets, PG-LRF achieves the best result on 13 of 15 dataset–metric combinations, including RMSE and FID on all three and every metric on MIMIC-AFib. The advantage is most consistent on distributional metrics, indicating that the physiological simulator guidance transfers across institutions, patient populations, and acquisition setups without any fine-tuning. Overall, these results indicate that the benefits of PG-LRF are not specific to MC-MED.\n\n\n> **W2: It would be helpful to see failure cases for the generation qualitative results.**\n\n> **Q2: What was the most common failure mode during inferencing?**\n\nThe most common failure mode was rate or rhythm mismatch, rather than waveform collapse. PG-LRF produced valid, R-peak-detectable ECGs in nearly all cases, but under weakly informative or severely corrupted PPG, the generated ECG could have an incorrect heart rate. For atrial-fibrillation samples, the model occasionally generated an overly regular rhythm relative to the irregular reference ECG.\n\n**Table R17: Heart-rate mismatch under different PPG conditions.**\n\n| PPG source | Dataset | Success (HR error ≤ 10 bpm) | HR failure (HR error > 10 bpm) | Mean HR error (bpm) |\n| --- | --- | ---: | ---: | ---: |\n| Clinical oximeter | MIMIC-AFib | 59% | 41% | 10.4 |\n| Smartphone camera | BUT PPG | 30% | 70% | 14.4 |\n\nHeart-rate failures are more frequent on noisy, out-of-distribution smartphone PPG, suggesting that severe sensor noise reduces the conditioning information available for accurate rate and rhythm reconstruction. We will include representative failure cases and discuss heart-rate mismatch and rhythm over-regularization in the revised manuscript."
+ },
+ "createdAt": "2026-07-30T18:07:37.968Z",
+ "modifiedAt": "2026-11-19T16:52:18.196Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=npGd8fNWE6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/ohucvbq0zi.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/ohucvbq0zi.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "OhUcvbq0ZI",
+ "replyTo": "QTwC6JTkQR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank the Area Chair for the clear summary and guidance. We address each weakness as follows:\n> **W1: [SNin, dFeY, BLDH] Limited evaluation datasets. Validating on a single dataset (MC-MED) restricts claims of generalizability. Evaluation or zero-shot testing on additional public datasets (e.g., MIMIC-AFib, BIDMC, VitalDB) is highly requested.**\n\n\nAddressed in Reviewer SNin W1/W3, Reviewer dFeY W2/Q3, and Reviewer BLDH W1. We added strict zero-shot evaluations on VitalDB, MIMIC-AFib, and BIDMC without fine-tuning or target-domain calibration. Results are reported in Tables R1–R3, R8–R10, and R14–R16. \n\n> **W2: [SNin, dFeY, BLDH] Lack of clarity on implementation of chosen hyperparameters for given model, as well as baselines for fair comparison.**\n\nAddressed in Reviewer SNin W2/W4 and Reviewer dFeY W3. We provide a sampling-step ablation in Table R4, clarify that the loss weights were selected through a coarse search on a held-out validation subset, and explain that all baselines use their official implementations, released pretrained checkpoints, and recommended configurations. All outputs are evaluated using the same post-generation normalization and metric pipeline.\n\n> **W3: [SNin, BLDH] Additional qualitative examples and visualizations would be helpful, especially due to the reconstruction nature of the model.**\n\n Addressed in Reviewer SNin Q2 and Reviewer BLDH W2/Q2. We provide morphology-based qualitative observations and quantify the most common failure mode under clinical and noisy smartphone PPG conditions in Table R17. Representative success and failure cases will be included in the revised manuscript.\n\nWe appreciate the Area Chair’s guidance, which helped us substantially strengthen the evaluation, implementation details, and failure analysis."
+ },
+ "createdAt": "2026-07-30T18:28:15.146Z",
+ "modifiedAt": "2026-11-19T16:52:18.152Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=OhUcvbq0ZI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/qtevpmlp2o.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/qtevpmlp2o.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "qteVPmlp2O",
+ "replyTo": "SInOCvX0tc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "> **Q1: During training of both stages, what were some instabilities the authors noticed?**\n\nWe thank the reviewer for this question. For Stage 1, the main sensitivity arose from introducing latent regularization before the modality-specific reconstructions were sufficiently established. Applying the KL and cross-modal alignment terms at their full weights from the beginning could slow reconstruction convergence and cause oscillation among the objectives. We therefore use small weights and progressively introduce these terms through linear warm-up. For Stage 2, applying the simulator losses to intermediate flow states was unstable because early decoded states do not yet exhibit well-formed ECG morphology, resulting in noisy physiological residuals and gradients. We therefore apply simulator guidance only to the terminal generated state. Freezing the pretrained autoencoder and forward mapper further avoids moving training targets, while gradient clipping and exponential moving averaging improve optimization stability. With these measures, we did not observe persistent divergence or mode collapse in either stage. \n\n\n\n> **Q3: The authors mention that z score normalization was applied to each segment. Have the authors tried min max normalization? It would be interesting to see this comparison as I found for rectified flow for ECGs, min max yielded consistently better results. However, it may be different in your setting so I am curious whether my experience and yours aligned.**\n\nWe thank the reviewer for this helpful suggestion. We compared min-max and z-score normalization and found that min-max produces lower point-wise and distributional errors, while the clinically relevant timing metrics remain very similar.\n\n**Table R18: Comparison of min-max and z-score normalization**\n\n| Normalization | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ | PR ↓ | QRS ↓ | QT ↓ | QTcF ↓ | P dur. ↓ | T dur. ↓ |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: |\n| Min-max | 0.57 | 0.77 | 21.27 | 16.53 | 3.93 | 59.2 | 39.0 | 29.9 | 32.2 | 19.7 | 21.0 |\n| Z-score | 0.71 | 1.07 | 39.68 | 37.79 | 3.94 | 59.9 | 38.6 | 29.3 | 32.2 | 19.3 | 21.3 |\n\nOur results align with the reviewer’s observation: min-max normalization substantially improves point-wise and distributional metrics, while HR and fiducial-interval errors remain comparable. We retain z-score normalization in the main experiments for consistency with the original experimental protocol and will report this comparison as an additional sensitivity analysis.\n\n\n> **Q4: Will the authors open source the model?**\n\nYes. Upon acceptance we will publicly release the full implementation."
+ },
+ "createdAt": "2026-07-30T18:08:04.611Z",
+ "modifiedAt": "2026-11-19T16:52:19.103Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=qteVPmlp2O",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/qtwc6jtkqr.json modified

+++ b/reviews/openreview/iovxn5dzbr/notes/qtwc6jtkqr.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair M216",
"content": {
- "metareview": "## (a) Scientific Claims/Findings\n\nThe paper proposes PG-LRF, a physiology-guided latent rectified flow framework for generating ECG signals from PPG signals. The core claim is that existing data-driven generation methods fail to capture physiological constraints. To address this, the authors introduce an electro-hemodynamic simulator and a physiology-aware autoencoder that jointly model ECG and PPG through shared cardiac phase dynamics.\n\n## (b) Strengths\n\n* [SNin, dFeY, BLDH] Compelling motivation. The integration of an electro-hemodynamic simulator provides a principled, physiology-aware foundation that improves upon purely data-driven cross-modal translation.\n* [SNin, dFeY, BLDH] Comprehensive evaluation on MC-MED, demonstrating strong performance in both signal generation metrics and downstream cardiovascular disease classification.\n* [dFeY, BLDH] Well-designed ablation studies that clearly isolate and validate the independent contributions of the core architectural components.\n\n## (c) Weaknesses\n\n* [SNin, dFeY, BLDH] Limited evaluation datasets. Validating on a single dataset (MC-MED) restricts claims of generalizability. Evaluation or zero-shot testing on additional public datasets (e.g., MIMIC-AFib, BIDMC, VitalDB) is highly requested.\n* [SNin, dFeY, BLDH] Lack of clarity on implementation of chosen hyperparameters for given model, as well as baselines for fair comparison.\n* [SNin, BLDH] Additional qualitative examples and visualizations would be helpful, especially due to the reconstruction nature of the model.\n\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from each reviewer during the rebuttal. In particular, the most critical weakness is the 1 dataset evaluation."
+ "metareview": "## (a) Scientific Claims/Findings\n\nThe paper proposes PG-LRF, a physiology-guided latent rectified flow framework for generating ECG signals from PPG signals. The core claim is that existing data-driven generation methods fail to capture physiological constraints. To address this, the authors introduce an electro-hemodynamic simulator and a physiology-aware autoencoder that jointly model ECG and PPG through shared cardiac phase dynamics.\n\n## (b) Strengths\n\n* [SNin, dFeY, BLDH] Compelling motivation. The integration of an electro-hemodynamic simulator provides a principled, physiology-aware foundation that improves upon purely data-driven cross-modal translation.\n* [SNin, dFeY, BLDH] Comprehensive evaluation on MC-MED, demonstrating strong performance in both signal generation metrics and downstream cardiovascular disease classification.\n* [dFeY, BLDH] Well-designed ablation studies that clearly isolate and validate the independent contributions of the core architectural components.\n\n## (c) Weaknesses\n\n* [SNin, dFeY, BLDH] Limited evaluation datasets. Validating on a single dataset (MC-MED) restricts claims of generalizability. Evaluation or zero-shot testing on additional public datasets (e.g., MIMIC-AFib, BIDMC, VitalDB) is highly requested.\n* [SNin, dFeY, BLDH] Lack of clarity on implementation of chosen hyperparameters for given model, as well as baselines for fair comparison.\n* [SNin, BLDH] Additional qualitative examples and visualizations would be helpful, especially due to the reconstruction nature of the model.\n\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from each reviewer during the rebuttal. In particular, the most critical weakness is the 1 dataset evaluation.",
+ "final_justification": "One remaining concern on SNin focusesd on not re-training their model on each dataset, however, this clarification was only established in the \"final justification\", and I think it is unfair to clarify it then, when I too was under the impression that they meant it in a zero-shot fashion. Additionally, zero-shot results are more interesting and stronger than re-training, due to how they focus on being able to learn a generalized information. Their other concern on \"There is also no analysis of how much performance is dropped under zero shot transfer.\" is clearly established in their zero-shot experiments. The other reviewers raised their scores accordingly with their major concerns addressed and saw this paper as an accept.\n\nI personally am still concerned about the lack of qualitative examples within the rebuttal, especially because links could have been included with AC permission (which I would have granted). If we were to take the comments at face value, then they have produced them, verifying such results, and the reviewers were satisfied with their justifications. I strongly encourage that the authors include qualitative examples within the main text of the final paper and emphasize them."
},
"createdAt": "2026-07-21T15:22:04.728Z",
- "modifiedAt": "2026-11-18T15:18:17.916Z",
+ "modifiedAt": "2026-11-19T04:59:03.218Z",
"url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=QTwC6JTkQR",
"license": "CC-BY-4.0"
}

reviews/openreview/iovxn5dzbr/notes/vbef41bq10.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/vbef41bq10.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "vBef41bq10",
+ "replyTo": "SInOCvX0tc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer BLDH,\n\nThank you very much for revisiting our rebuttal and improving your assessment. We sincerely appreciate your thoughtful review and recognition of our additional clarifications and results.\n\nThanks,\n\nAuthors"
+ },
+ "createdAt": "2026-08-03T10:00:30.477Z",
+ "modifiedAt": "2026-11-19T16:52:18.282Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=vBef41bq10",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/x0ym1bxu1x.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/x0ym1bxu1x.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "x0Ym1BxU1X",
+ "replyTo": "Goapr4CkoH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "> **Q1: Robustness of ICD-stratified simulator fitting: How robust is the ICD-stratified simulator fitting when the number of samples in each ICD group is small, especially for rare disease categories? In such cases, the fitting procedure may become unstable. Do the authors have any fallback strategies, such as merging ICD groups or applying stronger regularization? It would also be helpful to include a sensitivity analysis showing how the results change when the number of ICD groups is varied.**\n\n\nWe thank the reviewer for this important question. To avoid unstable simulator fitting for rare ICD categories, we restrict ICD-stratified fitting to the top-\\(K\\) most frequent categories and exclude lower-frequency categories from this fitting procedure. Under our default \\(K=100\\), even the smallest retained category contains 53,388 training windows from 87 visits. The selected top-100 categories cover 79.1% of all training windows and 77.4% of visits, providing sufficient support for stable group-specific parameter estimation. We further evaluate sensitivity to the number of retained ICD groups:\n\n**Table R11: Sensitivity to the number of ICD groups used for simulator fitting.**\n\n| Number of ICD groups | MAE ↓ | RMSE ↓ | FD ↓ | FID ↓ | HR MAE ↓ |\n| ---: | ---: | ---: | ---: | ---: | ---: |\n| 100 | **0.710** | **1.070** | **39.68** | **37.79** | **3.94** |\n| 60 | 0.714 | 1.071 | 41.83 | 38.26 | 4.04 |\n| 30 | 0.717 | 1.071 | 46.15 | 39.34 | 4.01 |\n\n\nThe top-30, top-60, and top-100 groups cover 56.0%, 69.7%, and 79.1% of all windows, respectively, corresponding to 53.4%, 67.7%, and 77.4% of visits. Performance remains stable across 30, 60, and 100 groups. We use 100 groups by default to preserve greater clinical heterogeneity, while the small overall variation shows that PG-LRF is not sensitive to the exact ICD grouping choice. \n\n\n\n\n> **Q4: Inference efficiency and clinical practicality: Please provide the trade-off between generation quality and inference time when varying the number of ODE solver steps N. In addition, for potential real-time or online monitoring applications, what level of latency can be expected with the current architecture?**\n\nWe thank the reviewer for this suggestion. We evaluate generation quality and end-to-end inference efficiency across different numbers of ODE solver steps (N). The reported latency is the amortized time per 10-second ECG segment at batch size 64 and includes PPG encoding, flow integration, and ECG decoding.\n\n**Table R12: Quality–latency trade-off versus ODE solver steps N.**\n\n| N | MAE ↓ | RMSE ↓ | HR MAE ↓ | End-to-end ms / ECG ↓ |\n| -: | ----: | -----: | -------: | --------------------: |\n| 5 | **0.66** | **1.02** | **3.9** | **2.47** |\n| 10 | 0.71 | 1.07 | 4.0 | 4.42 |\n| 15 | 0.73 | 1.09 | 4.0 | 6.39 |\n| 20 | 0.74 | 1.10 | 4.1 | 8.40 |\n\nLatency increases approximately linearly with (N), while MAE and RMSE are best at (N=5) and HR MAE remains nearly unchanged across settings. This is consistent with rectified flow producing sufficiently straight transport trajectories that can be accurately integrated using only a few Euler steps. Overall, (N=5) provides the best accuracy–efficiency balance.\nAt (N=5), PG-LRF generates a 10-second ECG in 2.47 ms per sample under batched inference, corresponding to an approximately (4{,}050\\times) real-time factor. These results indicate that inference computation is negligible relative to the signal acquisition duration and supports the feasibility of real-time or online deployment.\n\n> **L1: Heart-rate dependence: The paper does not sufficiently discuss the robustness of PAT estimation under very high or very low heart-rate conditions. In such cases, adjacent beats may overlap, and ST-segment variations may affect the reliability of PAT estimation.**\n\nWe thank the reviewer for highlighting this limitation. At extreme heart rates, shortened or prolonged cardiac cycles and abnormal morphology can reduce the reliability of ECG–PPG beat association and PAT estimation. To avoid introducing noisy physiological supervision, we apply the PAT-related constraint only to training samples with heart rates between 50 and 100 bpm. Samples outside this range are still used for the primary rectified-flow training objective.\nPAT serves only as a soft training-time regularizer and is neither estimated nor required during inference. We also use differentiable soft phase estimation and circular phase distance to reduce sensitivity to small peak-localization errors. We will clarify this limitation in the revised manuscript."
+ },
+ "createdAt": "2026-07-30T18:04:45.927Z",
+ "modifiedAt": "2026-11-19T16:52:19.077Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=x0Ym1BxU1X",
+ "license": "CC-BY-4.0"
+}