potentialpaper

PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation

Import NeurIPS 2026 submission iOvXn5DzBr: 5 notes

@openreview[bot] · 2026-11-22 17:58 UTC · 701004eecf05

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,33 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "iOvXn5DzBr"
+ }
+ ],
+ "title": "PPG2ECG: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation",
+ "authors": [
+ "Xiaoda Wang",
+ "Minxiao Wang",
+ "Kaiqiao Han",
+ "Defu Cao",
+ "Ching Chang",
+ "Yidan Shi",
+ "Runze Yan",
+ "Xiao Luo",
+ "Yan Liu",
+ "Xiao Hu",
+ "Yizhou Sun",
+ "Wei Wang",
+ "Carl Yang"
+ ],
+ "abstract": "Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PPG2ECG, a physiology-guided latent rectified flow framework. PPG2ECG introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PPG2ECG significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/iovxn5dzbr/forms.json added

+++ b/reviews/openreview/iovxn5dzbr/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/bsqaonlmve.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/bsqaonlmve.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "BSqaoNlMVe",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "## (a) Scientific Claims/Findings\n\nThe paper proposes PG-LRF, a physiology-guided latent rectified flow framework for generating ECG signals from PPG signals. The core claim is that existing data-driven generation methods fail to capture physiological constraints. To address this, the authors introduce an electro-hemodynamic simulator and a physiology-aware autoencoder that jointly model ECG and PPG through shared cardiac phase dynamics.\n\n## (b) Strengths\n\n* [SNin, dFeY, BLDH] Compelling motivation. The integration of an electro-hemodynamic simulator provides a principled, physiology-aware foundation that improves upon purely data-driven cross-modal translation.\n* [SNin, dFeY, BLDH] Comprehensive evaluation on MC-MED, demonstrating strong performance in both signal generation metrics and downstream cardiovascular disease classification.\n* [dFeY, BLDH] Well-designed ablation studies that clearly isolate and validate the independent contributions of the core architectural components.\n\n## (c) Weaknesses\n\n* [SNin, dFeY, BLDH] Limited evaluation datasets. Validating on a single dataset (MC-MED) restricts claims of generalizability. Evaluation or zero-shot testing on additional public datasets (e.g., MIMIC-AFib, BIDMC, VitalDB) is highly requested.\n* [SNin, dFeY, BLDH] Lack of clarity on implementation of chosen hyperparameters for given model, as well as baselines for fair comparison.\n* [SNin, BLDH] Additional qualitative examples and visualizations would be helpful, especially due to the reconstruction nature of the model.\n\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from each reviewer during the rebuttal. In particular, the most critical weakness is the 1 dataset evaluation.",
+ "final_justification": "One remaining concern on SNin focusesd on not re-training their model on each dataset, however, this clarification was only established in the \"final justification\", and I think it is unfair to clarify it then, when I too was under the impression that they meant it in a zero-shot fashion. Additionally, zero-shot results are more interesting and stronger than re-training, due to how they focus on being able to learn a generalized information. Their other concern on \"There is also no analysis of how much performance is dropped under zero shot transfer.\" is clearly established in their zero-shot experiments. The other reviewers raised their scores accordingly with their major concerns addressed and saw this paper as an accept.\n\nI personally am still concerned about the lack of qualitative examples within the rebuttal, especially because links could have been included with AC permission (which I would have granted). If we were to take the comments at face value, then they have produced them, verifying such results, and the reviewers were satisfied with their justifications. I strongly encourage that the authors include qualitative examples within the main text of the final paper and emphasize them."
+ },
+ "createdAt": "2026-09-24T11:16:09.390Z",
+ "modifiedAt": "2026-11-18T14:52:17.389Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=BSqaoNlMVe",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/fom4z2wjyq.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/fom4z2wjyq.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "FOm4z2wjyQ",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer SNin",
+ "content": {
+ "summary": "The paper proposes a physiology-guided latent rectified flow framework called PG-LRF. The proposed method overcomes the limitations of purely data-driven PPG-to-ECG generation. It uses a physiological simulator and a physiology-aware autoencoder to enforce electro hemodynamic consistency during training. Experiments on the MC-MED dataset show better results than baseline methods. It also outperforms downstream disease classification.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n\n1. The paper introduces a novel method to integrate an electro hemodynamic simulator with latent rectified flow. This allows ECG signals to be generated based on physiological dynamics instead of relying on statistical/data-driven cross-modal translation.\n2. The method is evaluated on the MCMED dataset and outperforms other baseline methods.\n\n\nWeakness:\n\n1. The evaluation is limited to only one dataset. Additional experiments on other publicly available dataset will give a more generalized result of the proposed framework. It will also give a clear idea whether the framework can beat all the baselines on different dataset. Other available dataset are : MIMIC-AFib [1] , VitalDB [2] , BIDMC [3].\n2. The effect of the number of sampling steps is not evaluated. There is no discussion about whether the same sampling steps are taken for all the baseline models or not. For example, PGFlowECG [4] achieves its best performance at T = 5.\n3. The paper also lacks a zero shot generalization experiment. For example, the model is trained on one dataset (let’s say MCMED) and evaluated on another dataset (MIMIC-AFib) without fine-tuning. This will give stronger proof of its robustness.\n4. There is also no discussion about how these values (λ_ecg = 5.0, λ_ppg = 0.25, λ_deriv = 3.0, and λ_peak = 12.0) are chosen.\n\n\n[1] Noise detection in electrocardiogram signals for intensive care unit patients\n[2] VitalDB, a high-fidelity multi-parameter vital signs database in surgical patients\n[3] Toward a robust estimation of respiratory rate from pulse oximeters\n[4] PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. How does the model perform to generate correct ECG from noisy PPG as PPG quality varies substantially?\n\n2. Does the model outperform other baseline in visualization quality as well?",
+ "limitations": "yes",
+ "rating": 3,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "no",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I thank the authors for the detailed experiments. But my major concern regarding multiple dataset(W1) is not addressed. It has been merged with zero shot analysis (W3). W1 and W3 serve different purposes.\n\n(W1) I asked for PG-LRF trained on each dataset with its own splits to see whether the proposed method wins as in Table 1 of the submitted paper. All reported external results use MC-MED trained checkpoints. So the comparison was not made.\n\n(W3) There is also no analysis of how much performance is dropped under zero shot transfer.\n\nI appreciate the clarifications on my other concerns. I therefore retain my original score."
+ },
+ "createdAt": "2026-06-26T08:08:32.167Z",
+ "modifiedAt": "2026-11-18T13:34:59.129Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=FOm4z2wjyQ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/goapr4ckoh.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/goapr4ckoh.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "Goapr4CkoH",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer dFeY",
+ "content": {
+ "summary": "This paper addresses the issue of generating an ECG signal from a PPG signal. The authors propose PG-LRF, which includes the electro-hemodynamic generation problem and physiological guidance to address data-driven generation and statistical alignment. The method was evaluated using the MC-MED (a large-scale, multimodal clinical monitoring dataset) in terms of waveform-level, morphology and interval fidelity, and was compared with four other generative methods. The authors claim that their approach consistently outperforms existing baselines, generating ECGs that are signal-faithful and preserve critical clinical intervals, thereby improving the classification of cardiovascular disease.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "S1. Clarity of Physiological Rationale:\nThe asymmetric relationship between photoplethysmography (PPG) and electrocardiography (ECG) wherein PPG represents the \"delayed hemodynamic response\" of ECG is expressed within a unified mathematical framework known as a shared heartbeat phase oscillator, thereby providing a physiological basis for the design choices.\n\nS2. Ensuring Practicality Through Training-Inference Asymmetry:\nThe utilization of the simulator and the ECG-to-PPG forward mapper is exclusive to the training. Conversely, during the inference phase, the system functions solely on PPG input. This enhancement signifies a notable advancement in terms of its potential for integration into wearable devices and analogous applications.\n\nS3. Multifaceted Evaluation and Large-Scale Data:\nThis paper utilizes 118,385 clinical data points derived from real-world patient cases and employs a three-tiered evaluation framework. This evaluation includes the following metrics: waveform-level metrics (mean absolute error [MAE], root mean square error [RMSE], fractal dimension [FD], fractal integral dimension [FID]), clinically meaningful morphological metrics (PR interval, QRS width, QT interval, QTcF, ST-J60 deviation, P-wave/T-wave duration), and the area under the curve (AUROC) for multi-label heart disease classification. This comprehensive approach lends the results high persuasiveness.\n\nS4. The validity of the ablation design is as follows:\nThe two ablation scenarios, \"Simulator Removal (w/o Sim)\" and \"PAE Removal (w/o PAE),\" correspond to the two major design elements of this method. This methodological framework allows for experimental verification of the independent effects of each component.\n\nW1. Unverified details regarding the training of the ECG-to-PPG forward mapper and its impact on performance:\nA paucity of verification regarding the training details and the impact on performance of the ECG-to-PPG forward mapper is observed.\nDespite the fact that G_p is frozen post-pre-training, the quality of said pre-training (i.e., the extent of waveform error) directly impacts the accuracy of the simulator-induced loss, as delineated in Equation (26). In the event that the mapper is found to be inaccurate, the regularization effect on ECG→PPG hemodynamic consistency may be weakened or distorted. However, it is important to note that the performance of the mapper is not evaluated in isolation.\n\nW2. Limitations of generalizability due to evaluation using a single dataset:\nThis paper is subject to limitations in terms of generalizability, which are attributable to the evaluation of a single dataset.\nAs stated in Appendix E, the evaluation is constrained exclusively to MC-MED (Stanford-affiliated emergency department, 2020–2022). However, there is a paucity of evidence regarding the generalizability of these findings to different institutions, patient populations, or sensor devices. Further validation on public datasets, such as BIDMC, is necessary, along with a discussion of the applicability of these methods to data from other institutions.\n\nW3. Insufficient verification of baseline implementation reproducibility and fairness:\nAdequate verification of baseline implementation reproducibility and fairness is lacking.\nAll four baselines (CardioFlow, RDDM, CardioGAN, PPGFlowECG) have been adapted to the MC-MED setting, which differs from their original proposal settings (e.g., dataset, sampling rate). However, the absence of details regarding the adaptation process, such as the performance of hyperparameter tuning and the utilization of official implementations, hinders the ability to verify the accurate capture of baseline performance.",
+ "quality": 3,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "Q1. Robustness of ICD-stratified simulator fitting:\nHow robust is the ICD-stratified simulator fitting when the number of samples in each ICD group is small, especially for rare disease categories? In such cases, the fitting procedure may become unstable. Do the authors have any fallback strategies, such as merging ICD groups or applying stronger regularization? It would also be helpful to include a sensitivity analysis showing how the results change when the number of ICD groups is varied.\n\nQ2. Quality evaluation of the ECG-to-PPG forward mapper:\nPlease provide a quantitative evaluation of the pretrained ECG-to-PPG forward mapper G_p, such as PPG waveform reconstruction error. In addition, have the authors investigated how the effect of L_sim in Eq. (26) changes when the mapper is intentionally weakened? Such an ablation study would help clarify the dependence of the proposed method on the quality of the forward mapper.\n\nQ3. Generalization to other datasets:\nDo the authors have any preliminary results on datasets other than MC-MED, such as BIDMC or MIMIC-III waveform data? If not, how robust do the authors expect the trained model to be against differences in PPG sensor characteristics and sampling rates across datasets?\n\nQ4. Inference efficiency and clinical practicality:\nPlease provide the trade-off between generation quality and inference time when varying the number of ODE solver steps N. In addition, for potential real-time or online monitoring applications, what level of latency can be expected with the current architecture?",
+ "limitations": "Heart-rate dependence:\nThe paper does not sufficiently discuss the robustness of PAT estimation under very high or very low heart-rate conditions. In such cases, adjacent beats may overlap, and ST-segment variations may affect the reliability of PAT estimation.\n\nDiversity of sensor modalities:\nThe impact of different PPG sensor modalities is not adequately considered. For example, reflected PPG and transmitted PPG, or smartwatch-type sensors and fingertip clip-type sensors, can exhibit substantially different waveform characteristics. It would be helpful for the authors to discuss how such differences may affect the proposed method and whether additional adaptation or calibration would be required.",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "There is a missing equation number (Eq.(??)) in the list of equations in Appendix B.2 (p. 15).",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal addresses most of my concerns through additional cross-dataset evaluations, mapper analysis, sensitivity experiments, and inference-efficiency results. These additions substantially strengthen the paper.\n\nOne concern remains regarding baseline fairness, since PG-LRF was trained on MC-MED, while the baselines appear to use pretrained checkpoints without retraining on the same dataset.\n\nOverall, the resolved concerns outweigh the remaining issue. I therefore raise my rating to 4 (Borderline Accept)."
+ },
+ "createdAt": "2026-06-15T22:48:26.065Z",
+ "modifiedAt": "2026-11-18T13:35:00.540Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=Goapr4CkoH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/qtwc6jtkqr.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/qtwc6jtkqr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "QTwC6JTkQR",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair M216",
+ "content": {
+ "metareview": "## (a) Scientific Claims/Findings\n\nThe paper proposes PG-LRF, a physiology-guided latent rectified flow framework for generating ECG signals from PPG signals. The core claim is that existing data-driven generation methods fail to capture physiological constraints. To address this, the authors introduce an electro-hemodynamic simulator and a physiology-aware autoencoder that jointly model ECG and PPG through shared cardiac phase dynamics.\n\n## (b) Strengths\n\n* [SNin, dFeY, BLDH] Compelling motivation. The integration of an electro-hemodynamic simulator provides a principled, physiology-aware foundation that improves upon purely data-driven cross-modal translation.\n* [SNin, dFeY, BLDH] Comprehensive evaluation on MC-MED, demonstrating strong performance in both signal generation metrics and downstream cardiovascular disease classification.\n* [dFeY, BLDH] Well-designed ablation studies that clearly isolate and validate the independent contributions of the core architectural components.\n\n## (c) Weaknesses\n\n* [SNin, dFeY, BLDH] Limited evaluation datasets. Validating on a single dataset (MC-MED) restricts claims of generalizability. Evaluation or zero-shot testing on additional public datasets (e.g., MIMIC-AFib, BIDMC, VitalDB) is highly requested.\n* [SNin, dFeY, BLDH] Lack of clarity on implementation of chosen hyperparameters for given model, as well as baselines for fair comparison.\n* [SNin, BLDH] Additional qualitative examples and visualizations would be helpful, especially due to the reconstruction nature of the model.\n\n\n## (d) Recommendations\n\nPlease address the weaknesses above and from each reviewer during the rebuttal. In particular, the most critical weakness is the 1 dataset evaluation."
+ },
+ "createdAt": "2026-07-21T15:22:04.728Z",
+ "modifiedAt": "2026-11-18T15:18:17.916Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=QTwC6JTkQR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/notes/sinocvx0tc.json added

+++ b/reviews/openreview/iovxn5dzbr/notes/sinocvx0tc.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "SInOCvX0tc",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer BLDH",
+ "content": {
+ "summary": "The authors propose PG-LRF. PG-LRF generates ECG from PPG by combining a physiology-aware latent space with simulator-guided rectified flow. Its electro-hemodynamic simulator links ECG and delayed PPG through shared cardiac phase dynamics, encouraging generated ECGs to be physiologically plausible and clinically useful. The model also performs well compared with baselines in both generation and downstream classification.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths\n- Well written and easy to follow.\n- The figures are clear and visually appealing.\n- The experimental details were clear and seem to be reproducible.\n- Ablation study on their loss components were appreciated.\n\nWeaknesses\n- Evaluated solely on one dataset. I think this is the biggest weakness. Showing generation/classification performance on one more dataset would be a huge strength to this paper.\n- It would be helpful to see failure cases for the generation qualitative results.\n- See questions.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "- During training of both stages, what were some instabilities the authors noticed?\n- What was the most common failure mode during inferencing?\n- The authors mention that z score normalization was applied to each segment. Have the authors tried min max normalization? It would be interesting to see this comparison as I found for rectified flow for ECGs, min max yielded consistently better results. However, it may be different in your setting so I am curious whether my experience and yours aligned.\n- Will the authors open source the model?",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "NA",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The authors adequately carried out my requested experiments and answered all of my questions. I have adjusted the score accordingly."
+ },
+ "createdAt": "2026-06-01T21:03:10.323Z",
+ "modifiedAt": "2026-11-18T13:35:01.466Z",
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr&noteId=SInOCvX0tc",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/iovxn5dzbr/submission.json added

+++ b/reviews/openreview/iovxn5dzbr/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "iOvXn5DzBr",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 1430,
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr",
+ "license": "CC-BY-4.0"
+}

versions/v_srwasg6g.json added

+++ b/versions/v_srwasg6g.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-16",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 1430,
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr",
+ "reviews": "openreview/iovxn5dzbr",
+ "evidence": [
+ "https://openreview.net/forum?id=iOvXn5DzBr"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=iOvXn5DzBr",
+ "evidence": [
+ "https://openreview.net/forum?id=iOvXn5DzBr"
+ ]
+}