EEG-X: Toward Device-Agnostic and Noise-Robust Foundation Models for EEG
Update NeurIPS 2026 submission UHwOAjPtEg: 13 notes
@openreview[bot] · 2026-11-24 15:51 UTC · 51e6deb3be03 ·
reviews/openreview/uhwoajpteg/notes/1tef0nikm7.json added
+++ b/reviews/openreview/uhwoajpteg/notes/1tef0nikm7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "1tEf0NIkM7",+ "replyTo": "tNaxKChuFm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer zaCL",+ "content": {+ "title": "Reply to rebuttal",+ "comment": "Thank you for the detailed response and the different clarifications, particularly regarding the handling of channel information, the use of rASR, the DiCT formulation, and the ablation settings.\n\nA few points remain:\n\n- The mapping to the universal location space is still unclear. In particular, the transformation from the original (x,y,z) coordinates to the (u,v) representation should be made more explicit.\n- The new rASR comparison is useful. Reporting the uncertainty associated with the results in Table 5 would further improve the discussion around their interpretation.\n- I appreciate the additional statistical analysis. However, five runs provide limited statistical power, and it remains unclear which observations were paired in the Wilcoxon tests and how the small cross-domain p-values were obtained. Please clarify the pairing procedure, and number of observations."+ },+ "createdAt": "2026-07-31T13:28:21.891Z",+ "modifiedAt": "2026-11-19T17:01:36.771Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=1tEf0NIkM7",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/5nvoqkqdvo.json added
+++ b/reviews/openreview/uhwoajpteg/notes/5nvoqkqdvo.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5nvOqkqDVo",+ "replyTo": "Bq4GpD3S7g",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer cbFB",+ "content": {+ "comment": "Thanks for the detailed response and additional experiments. You have addressed pretty much all my concerns, especially with the head to head comparison against REVE, and novelty matters less under the use-inspired track. The statistical test is also helpful to confirm that EEG-X's in domain gains over strong baselines are not as significant after correction while cross-domain is. For the limitations, the authors should soften their claim in the abstract and paper, saying that it's device agnostic up to linear probing and standard configurations, with generalization to non-standard electrode placement untested. Nevertheless, it's a solid contribution and I have increased my score accordingly."+ },+ "createdAt": "2026-08-04T00:57:26.780Z",+ "modifiedAt": "2026-11-19T17:01:36.590Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=5nvOqkqDVo",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/bq4gpd3s7g.json added
+++ b/reviews/openreview/uhwoajpteg/notes/bq4gpd3s7g.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Bq4GpD3S7g",+ "replyTo": "tapYaPpMLK",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer cbFB (2/2)",+ "comment": "**Q1-Learned vs. fixed random kernels in DiCT**\n\nDiCT is designed to provide a stable, task-independent feature space for measuring reconstruction quality rather than acting as an additional trainable feature extractor. If learned jointly with the encoder and decoder, the kernels could adapt to the current reconstructions or dataset-specific patterns simply to reduce the training loss, weakening their role as a task independent feature extractor. To test this design choice, we made the DiCT kernels learnable on STEW and DREAMER while keeping all other settings unchanged. Learnable kernels performed worse than fixed random kernels on both datasets.\n\n| DiCT comparison space | STEW Accuracy | DREAMER Accuracy |\n|---|---:|---:|\n| Learnable DiCT kernels | 77.10 | 52.68 |\n| Fixed random DiCT kernels | **80.32** | **58.14** |\n\n**Q2 — Real EEG reconstruction using MSE and DiCT**\nThe toy example was motivated by behavior first observed when reconstructing real EEG signals using MSE loss. In practice, MSE often produced overly averaged reconstructions and sometimes reproduced common noise patterns, whereas DiCT better preserved informative structure. We used the toy example only to illustrate this behavior more clearly and will add representative real-signal reconstructions to the revised manuscript.\n\n**Q3 — rASR preprocessing versus using rASR as a pretext task**\n\nThe two settings affect the learning pipeline differently. With rASR preprocessing, the cleaned signal replaces the raw input, so any removed neural components are unavailable to the classifier. In EEG-X, the encoder receives the original raw EEG, while the rASR-cleaned signal is used only as the reconstruction target during self-supervised pretraining. Thus, rASR acts as a denoising supervisory signal rather than a hard input filter. At downstream time, representations are extracted directly from raw EEG without rASR preprocessing, allowing the model to retain access to the full signal while reducing its reliance on dominant artifacts. As shown in the ablation study in Table 4, using raw EEG instead of the rASR-cleaned signal as the reconstruction target reduces performance by 2.42 in-domain and 1.43 cross-domain."+ },+ "createdAt": "2026-07-29T13:37:16.471Z",+ "modifiedAt": "2026-11-19T17:01:36.886Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=Bq4GpD3S7g",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/cuwgnyqios.json added
+++ b/reviews/openreview/uhwoajpteg/notes/cuwgnyqios.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "CUWGNYQiOS",+ "replyTo": "EjIqJElWaL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the thoughtful and constructive feedback. We address the concerns below.\n\n**Q1 — DiCT gradient**\n\nThank you for raising this ambiguity. For simplicity, Eqs. (5)–(6) describe only the (hard winner-take-all) forward pass. A hard `argmax` creates a sparse gradient path because only the selected maximum response receives a gradient, while the remaining responses receive no gradient. To provide a smoother gradient path during training, we use a straight-through estimator (STE). Let\n\n$$ h=\\mathrm{one\\_hot}(\\arg\\max(R)) $$\ndenote the hard assignment, and\n$$ p=\\mathrm{softmax}(R) $$\nthe corresponding soft assignment. We define\n$$ \\tilde{p}=h+p-\\mathrm{detach}(p). $$\n\nThus, the forward pass uses the hard winner-take-all assignment, while the backward pass follows the softmax gradient through $p$, allowing gradients to propagate to all responses. We will add this backward-pass formulation and clarify the gradient path in the camera-ready version.\n\n**Q2 — rASR calibration**\n\nWe ensured that there is no leakage. All datasets are split at the subject level, ensuring that no subject appears in more than one of the training, validation, or test sets. The rASR calibration samples are selected exclusively from the training split, and all calibration parameters, including the reference covariance and mixing matrix, are estimated using only training subjects. \n\n**Q3 — Statistical significance**\n\nWe performed pairwise two-sided Wilcoxon signed-rank tests on all matched results, using five runs per dataset and method, followed by Holm correction for multiple comparisons. For the in-domain results in Table 2, EEG-X achieved the highest average rank. However, its differences from REVE and ST-EEGFormer were not significant after correction, while its improvements over all other baselines were statistically significant.\n\n| Setting | REVE | ST-EEGFormer | EEG2Rep | CBraMod | LaBraM | EEGPT | BioT | MAEEG |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|\n| In-domain adjusted p-value | 0.5324 | 0.1700 | 0.0264 | 0.0056 | 0.0036 | 0.0036 | 0.0036 | 0.0036 |\n\nFor the cross-domain results in Table 3, EEG-X ranked first and was significantly better than every competing method after Holm correction. The adjusted p-value was 0.0021 for all comparisons. \n\n**Q4 — Scope of the foundation-model claim**\n\nWe agree that the current evidence does not yet establish EEG-X as a fully general EEG foundation model. We therefore frame EEG-X as a step toward an EEG foundation model as indicated by the title \"Toward Device-Agnostic and Noise-Robust Foundation Models for EEG\".\n\n**Q5 — Novelty relative to prior spatial encodings and random convolutional transforms**\n\n**Spatial encoding:** The novelty is not the use of electrode coordinates itself. Unlike REVE, which jointly encodes spatial coordinates and temporal position, EEG-X encodes each scalp coordinate separately and combines the resulting spatial representation with temporal position afterward. This factorized design preserves the contribution of each spatial axis and better maintains similarity between adjacent electrodes, particularly under compact embedding dimensions. To directly evaluate this distinction, we replaced our channel embedding with the REVE encoding while keeping the EEG-X backbone, embedding dimension $(d_e=16)$, and training setup unchanged:\n\n| Channel embedding |Accuracy| AUROC |\n|---|---:|---:|\n|EEG-X (REVE encoding)|85.93|92.12|\n|EEG-X (our encoding)|**86.89**|**93.51**|\n\nWith compact embeddings, REVE's joint Fourier components must be truncated, which may underrepresent some coordinate axes and reduce sensitivity to true electrode adjacency. In contrast, our factorized encoding explicitly preserves each spatial direction and is designed for transfer across different montages.\n\n**Random convolutional transforms:** prior methods generally use random kernels as fixed feature extractors for classification. DiCT uses them instead as a self-supervised reconstruction objective. We apply multi-scale kernels designed to capture temporal patterns across EEG frequency ranges, project both the reconstruction and target into the same fixed feature space, and minimize their discrepancy. Thus, DiCT is not a classifier-side feature extractor, but a parameter-free reconstruction loss that encourages preservation of informative EEG dynamics while reducing sensitivity to point-wise amplitude errors and small temporal misalignments. We will clarify these distinctions in the related-work and method sections.\n\n**Effect of the artifact-removal method**\n\nWe agree that comparison with an alternative artifact-removal method would strengthen the manuscript. We therefore compared rASR with ICA (using 10 components). \n| Dataset | ICA | rASR |\n|---|---:|---:|\n| STEW | 80.21 ± 1.18 | **80.96 ± 1.25** |\n| DREAMER | **58.16 ± 1.33**| 58.14 ± 1.30|\n\nThe difference between the two methods is at most 0.75 percentage points, which is smaller than the reported run-to-run standard deviation."+ },+ "createdAt": "2026-07-29T13:54:10.693Z",+ "modifiedAt": "2026-11-19T17:01:36.863Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=CUWGNYQiOS",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/ekdvanfusv.json added
+++ b/reviews/openreview/uhwoajpteg/notes/ekdvanfusv.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "EKDvAnfusv",+ "replyTo": "lWsqxA5zWy",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Ethics Chairs",+ "content": {+ "title": "Clarification regarding prompt injection",+ "comment": "Thank you for flagging the possible prompt injection. This was *not* injected by the authors and should *not* be taken into consideration in the paper decision. No further action is required."+ },+ "createdAt": "2026-07-30T10:35:58.206Z",+ "modifiedAt": "2026-11-19T17:01:37.157Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=EKDvAnfusv",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/ihswabtlmm.json added
+++ b/reviews/openreview/uhwoajpteg/notes/ihswabtlmm.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "IhswAbTLmM",+ "replyTo": "qHKGiIQSro",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Meta-Review (1/2)",+ "comment": "We thank the AC for the meta-review and their guidance in improving our work. In our rebuttal responses, we have addressed every question raised by the reviewers through additional experiments, statistical analyses, and methodological clarifications. Below, we summarize how each concern highlighted in the meta-review has been addressed. The full details of all new results and clarifications are provided in our individual responses to the reviewers.\n\n**1. Differentiability of the DiCT Objective**\n\nReviewer btYd raised a key concern about the non-differentiability of the `argmax` and discrete assignments in DiCT. We clarified that Equations 5–6 describe only the forward operation, while the implementation uses a straight-through estimator for backpropagation.\n\nLet\n\n$$\nh=\\mathrm{one\\_hot}(\\arg\\max(R))\n$$\n\ndenote the hard assignment, and\n\n$$\np=\\mathrm{softmax}(R)\n$$\n\nthe corresponding soft assignment. We define\n\n$$\n\\tilde{p}=h+p-\\mathrm{detach}(p).\n$$\n\nThus, the forward pass uses the hard assignment, while the backward pass follows the softmax gradient through $p$. We will add this backward-pass formulation to the manuscript so that both the forward operation and the gradient path are explicitly described.\n\n\n**2. Statistical Significance of Empirical Gains**\n\nReviewers cbFB, zaCL, and btYd noted that several in-domain gains in Table 2 were small relative to the reported standard deviations.\n\nFor each model comparison, we used 20 matched observations, corresponding to 4 datasets × 5 runs. Each EEG-X result was paired with the competing model result from the same dataset and corresponding run or seed. We then applied a two-sided Wilcoxon signed-rank test, followed by Holm correction for multiple comparisons.\n\nFor the in-domain results, EEG-X achieved the highest average rank. However, its differences from REVE and ST-EEGFormer were not statistically significant after correction, while its improvements over the remaining baselines were significant.\n\n| Comparison with EEG-X | REVE | ST-EEGFormer | EEG2Rep | CBraMod | LaBraM | EEGPT | BioT | MAEEG |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|\n| Holm-adjusted $p$-value | 0.5324 | 0.1700 | 0.0264 | 0.0056 | 0.0036 | 0.0036 | 0.0036 | 0.0036 |\n\nFor the cross-domain results, we conducted the same analysis using 20 matched observations from the cross-domain setting. EEG-X ranked first and was significantly better than all competing methods after Holm correction, with an adjusted $p$-value of 0.0021 for every comparison.\n\nThe small cross-domain $p$-values result from the consistency of EEG-X across the 20 matched observations. For example, EEG-X outperformed REVE in 16 of 20 observations and ST-EEGFormer in 19 of 20 observations. We will include the full statistical comparison table in the appendix.\n\n\n**3. Ambiguity in Preprocessing vs. Target Generation**\n\nWe clarified that the references to ICA in Appendix C.4 are typographical errors. During pretraining, the encoder receives raw EEG, while rASR is used only to generate the artifact-cleaned reconstruction target.\n\nReviewer zaCL requested uncertainty estimates for the new rASR comparison. We therefore report the mean ± standard deviation over five runs:\n\n| Setting | STEW | DREAMER | TUAB | TUEV |\n|---|---:|---:|---:|---:|\n| Supervised (Raw Input) | 75.12 ± 2.64 | 55.69 ± 1.34 | 78.12 ± 0.98 | 88.24 ± 2.09 |\n| Supervised (rASR Input) | 73.68 ± 1.74 | 56.41 ± 1.04 | 78.32 ± 1.11 | 83.36 ± 1.68 |\n| Self-Supervised (Raw input with rASR target) | **80.32 ± 1.21** | **58.14 ± 1.35** | **81.02 ± 1.48** | **91.15 ± 1.41** |\n\nThe results show that using rASR only to generate the reconstruction target performs better than directly preprocessing the model input. This supports our interpretation of rASR as a denoising supervisory signal rather than a hard input filter."+ },+ "createdAt": "2026-08-03T03:50:49.963Z",+ "modifiedAt": "2026-11-19T17:01:36.738Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=IhswAbTLmM",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/mwo8gh9z6t.json added
+++ b/reviews/openreview/uhwoajpteg/notes/mwo8gh9z6t.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MWO8Gh9Z6T",+ "replyTo": "5nvOqkqDVo",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for engaging with our rebuttal and for your constructive feedback. \n\nYour comments—especially the suggestion to provide a head-to-head comparison with REVE—helped us improve the manuscript and clarify the contribution of our channel embedding.\n\nWe are glad that the additional experiments and explanations addressed your concerns. We also appreciate your recommendation regarding the device-agnostic claim and will revise the abstract and manuscript to clearly state the current scope and limitations.\n\nThank you again for reconsidering the paper and increasing your score."+ },+ "createdAt": "2026-08-04T03:59:47.549Z",+ "modifiedAt": "2026-11-19T17:01:36.586Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=MWO8Gh9Z6T",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/qcwvg3qxnb.json added
+++ b/reviews/openreview/uhwoajpteg/notes/qcwvg3qxnb.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "QcWvg3QXNB",+ "replyTo": "1tEf0NIkM7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer zaCL Follow-Up Comment",+ "comment": "We thank the reviewer for the positive feedback and continued engagement. We clarify the remaining points below.\n\n**Universal-coordinate mapping.** In our notation, $(u,v)$ are the 2D Cartesian scalp coordinates corresponding to the projected $(x,y)$ coordinates. We use $(u,v)$ instead of $(x,y)$ to avoid confusion with the input and output variables of EEG-X. When electrode coordinates are available, we use the matching location in the universal map. If there is no exact match, we use the closest standardized electrode location. When coordinates are unavailable, we obtain $(u,v)$ from the canonical channel name or the predefined montage/device layout. We will make this notation and mapping procedure explicit in the revised manuscript.\n\n**Uncertainty in Table 5.** We agree and now report mean ± standard deviation over five runs:\n\n| Setting | STEW | DREAMER | TUAB | TUEV |\n|---|---:|---:|---:|---:|\n| Raw input and raw target | 75.12 ± 2.64 | 55.69 ± 1.34 | 78.12 ± 0.98 | 88.24 ± 2.09 |\n| rASR-preprocessed input | 73.68 ± 1.74 | 56.41 ± 1.04 | 78.32 ± 1.11 | 83.36 ± 1.68 |\n| Raw input with rASR-generated target | **80.32 ± 1.21** | **58.14 ± 1.35** | **81.02 ± 1.48** | **91.15 ± 1.41** |\n\n\n**Wilcoxon pairing and sample size.** The tests were conducted on 20 matched observations in each setting: 4 datasets × 5 runs. Each EEG-X result was paired with the competing model result from the same dataset and corresponding run/seed. We then applied a two-sided Wilcoxon signed-rank test to these 20 paired differences.\n\nThe small cross-domain p-values arise from the consistency of EEG-X across the 20 matched observations. For example, EEG-X outperformed REVE in 16 of 20 observations, giving a raw p-value of 0.0002, and outperformed ST-EEGFormer in 19 of 20 observations. Holm correction was then applied across the pairwise comparisons. \n\n\nThank you again for your constructive feedback and for helping us improve the clarity of our work."+ },+ "createdAt": "2026-08-03T03:14:09.007Z",+ "modifiedAt": "2026-11-19T17:01:36.767Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=QcWvg3QXNB",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/qgap1aehsa.json added
+++ b/reviews/openreview/uhwoajpteg/notes/qgap1aehsa.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "qgaP1AehSA",+ "replyTo": "EjIqJElWaL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Formatting and Proofreading",+ "comment": "Thank you for identifying formatting and proofreading issues. Your detailed comments will help us improve the clarity, consistency, and overall presentation of the manuscript. We will carefully address all of them in the revised version."+ },+ "createdAt": "2026-08-03T12:51:43.299Z",+ "modifiedAt": "2026-11-19T17:01:36.589Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=qgaP1AehSA",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/qhkgiiqsro.json modified
+++ b/reviews/openreview/uhwoajpteg/notes/qhkgiiqsro.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair bPn4","content": {- "metareview": "**Summary of Contributions**\nThe paper proposes EEG-X, a self-supervised foundation model for EEG representation learning aimed at resolving two major challenges: device/electrode heterogeneity and low signal-to-noise ratio (SNR). The framework introduces three main components: (1) a location-based spatial channel embedding using universal scalp mapping; (2) a noise-aware masking strategy that reconstructs artifact-cleaned (rASR) targets rather than raw signals; and (3) a Dictionary-based Convolution Transformation (DiCT) objective designed to capture multi-scale temporal patterns and mitigate the amplitude bias of standard MSE. The model is evaluated on 8 datasets across in-domain and cross-domain settings.\n\n**Main Strengths**\n\n* **Strong Motivation & Relevance:** The paper tackles highly relevant, use-inspired challenges in EEG processing (cross-device generalization and artifact robustness). The motivation for moving away from raw time-domain MSE to a feature-space loss (DiCT) is well-reasoned.\n* **Extensive Benchmarking:** The evaluation spans multiple datasets with varying channel configurations, providing a solid testing ground for the cross-domain capabilities of the model.\n* **Thoughtful Ablations:** The ablation studies effectively isolate the individual contributions of the spatial embedding, artifact-aware reconstruction, and structured reconstruction objective.\n\n**Critical Weaknesses & Areas for Author Response**\nWhile the reviewers appreciate the direction of the work, several critical technical and empirical concerns must be addressed in the rebuttal:\n\n* **Differentiability of the DiCT Objective (Critical):** The mathematical formulation of the DiCT loss (Equations 5 and 6) utilizes `argmax` and discrete indicator counts. It is entirely unclear how gradients are propagated through these non-differentiable operations to train the neural network. Authors must explicitly clarify the gradient path (e.g., use of soft relaxations or straight-through estimators) and ensure it matches the implementation.\n* **Statistical Significance of Empirical Gains:** Across multiple tables (particularly Table 2), the performance gains over baseline methods are marginal and often fall within the reported standard deviations. Authors must provide statistical significance testing or confidence intervals to prove that these improvements are robust and not merely run-to-run variance. Tables 4 and 5 are also missing standard deviations entirely.\n* **Ambiguity in Preprocessing vs. Target Generation:** The experimental pipeline requires clarification. Section 2.2 states that rASR is used to generate reconstruction targets, but Appendix C.4 mentions the use of ICA preprocessing for several datasets. The exact interplay, ordering, and potential data leakage between ICA preprocessing and rASR target generation needs to be explicitly detailed. Furthermore, the calibration protocol for rASR must be clarified to ensure no test-set information is leaked.\n* **Presentation and Notation:** The presentation of the DiCT module lacks clarity. Notations (such as $W^{(d)}$) are not fully introduced, and the mechanism for concatenating reconstructions to preserve dimensionality is vaguely described. Additionally, figure references in the text are misaligned (e.g., referencing Figure 5 instead of Figure 3).\n* **Differentiation from Prior Work:** The novelty of the location-based channel embedding needs stronger justification when compared head-to-head with recent spatial encoding methods in EEG foundation models (such as REVE), specifically regarding how it handles unseen electrodes.\n\n**Initial Recommendation**\nThe paper presents promising ideas for EEG representation learning, but currently suffers from a potentially critical technical flaw regarding the differentiability of its core loss function, coupled with marginal empirical gains that lack statistical validation. A strong author response addressing the gradient propagation of DiCT and the statistical significance of the results is necessary to lean toward acceptance."+ "metareview": "**Summary of Contributions**\nThe paper proposes EEG-X, a self-supervised foundation model for EEG representation learning aimed at resolving two major challenges: device/electrode heterogeneity and low signal-to-noise ratio (SNR). The framework introduces three main components: (1) a location-based spatial channel embedding using universal scalp mapping; (2) a noise-aware masking strategy that reconstructs artifact-cleaned (rASR) targets rather than raw signals; and (3) a Dictionary-based Convolution Transformation (DiCT) objective designed to capture multi-scale temporal patterns and mitigate the amplitude bias of standard MSE. The model is evaluated on 8 datasets across in-domain and cross-domain settings.\n\n**Main Strengths**\n\n* **Strong Motivation & Relevance:** The paper tackles highly relevant, use-inspired challenges in EEG processing (cross-device generalization and artifact robustness). The motivation for moving away from raw time-domain MSE to a feature-space loss (DiCT) is well-reasoned.\n* **Extensive Benchmarking:** The evaluation spans multiple datasets with varying channel configurations, providing a solid testing ground for the cross-domain capabilities of the model.\n* **Thoughtful Ablations:** The ablation studies effectively isolate the individual contributions of the spatial embedding, artifact-aware reconstruction, and structured reconstruction objective.\n\n**Critical Weaknesses & Areas for Author Response**\nWhile the reviewers appreciate the direction of the work, several critical technical and empirical concerns must be addressed in the rebuttal:\n\n* **Differentiability of the DiCT Objective (Critical):** The mathematical formulation of the DiCT loss (Equations 5 and 6) utilizes `argmax` and discrete indicator counts. It is entirely unclear how gradients are propagated through these non-differentiable operations to train the neural network. Authors must explicitly clarify the gradient path (e.g., use of soft relaxations or straight-through estimators) and ensure it matches the implementation.\n* **Statistical Significance of Empirical Gains:** Across multiple tables (particularly Table 2), the performance gains over baseline methods are marginal and often fall within the reported standard deviations. Authors must provide statistical significance testing or confidence intervals to prove that these improvements are robust and not merely run-to-run variance. Tables 4 and 5 are also missing standard deviations entirely.\n* **Ambiguity in Preprocessing vs. Target Generation:** The experimental pipeline requires clarification. Section 2.2 states that rASR is used to generate reconstruction targets, but Appendix C.4 mentions the use of ICA preprocessing for several datasets. The exact interplay, ordering, and potential data leakage between ICA preprocessing and rASR target generation needs to be explicitly detailed. Furthermore, the calibration protocol for rASR must be clarified to ensure no test-set information is leaked.\n* **Presentation and Notation:** The presentation of the DiCT module lacks clarity. Notations (such as $W^{(d)}$) are not fully introduced, and the mechanism for concatenating reconstructions to preserve dimensionality is vaguely described. Additionally, figure references in the text are misaligned (e.g., referencing Figure 5 instead of Figure 3).\n* **Differentiation from Prior Work:** The novelty of the location-based channel embedding needs stronger justification when compared head-to-head with recent spatial encoding methods in EEG foundation models (such as REVE), specifically regarding how it handles unseen electrodes.\n\n**Initial Recommendation**\nThe paper presents promising ideas for EEG representation learning, but currently suffers from a potentially critical technical flaw regarding the differentiability of its core loss function, coupled with marginal empirical gains that lack statistical validation. A strong author response addressing the gradient propagation of DiCT and the statistical significance of the results is necessary to lean toward acceptance.",+ "final_justification": "The authors provided a strong and comprehensive rebuttal that successfully resolved all major concerns raised by the reviewers. Specifically, they:\n\n- Resolved the critical technical flaw by clarifying that the non-differentiable DiCT objective is optimized using a valid straight-through estimator (STE) during the backward pass.\n\n- Cleared up preprocessing ambiguities by confirming that rASR is strictly used for target generation (not input preprocessing) and explicitly detailing a safe, training-only calibration protocol to prevent data leakage.\n\n- Validated empirical gains by providing pairwise statistical significance tests (Wilcoxon signed-rank with Holm correction), which confirmed the robustness of their cross-domain results.\n\n- Justified novelty by adding a direct head-to-head comparison demonstrating the advantages of their factorized location-based channel embedding over existing methods like REVE.\n\nFollowing the rebuttal, all reviewers were satisfied with the clarifications, with Reviewers btYd and cbFB explicitly raising their scores. There are no outstanding ethical or technical flags. Given the practical relevance of this use-inspired framework, the extensive benchmarking, and the consensus among reviewers, I recommend the paper for Accept."},"createdAt": "2026-07-20T05:10:11.005Z",- "modifiedAt": "2026-11-18T15:18:22.905Z",+ "modifiedAt": "2026-11-19T04:59:05.795Z","url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=qHKGiIQSro","license": "CC-BY-4.0"}
reviews/openreview/uhwoajpteg/notes/tnaxkchufm.json added
+++ b/reviews/openreview/uhwoajpteg/notes/tnaxkchufm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "tNaxKChuFm",+ "replyTo": "BsU6gKETKH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the constructive feedback and for recognizing the quality and potential of EEG-X. We address each point below.\n\n1- Clarification of the device-agnostic channel representation.\n\nMost EEG datasets provide at least one of the following: electrode coordinates, channel names, or the device/montage type. EEG-X uses this information to assign each channel a location in a shared scalp coordinate system. We build the **universal location mapping** by combining the standard electrode positions from the 10–20, 10–10, and 10–05 systems into one dense map. Each node in this map has a canonical channel name and Cartesian coordinate.\n\nWe handle each as follows:\n\n- **Coordinates are available:** We use the exact matching node in the universal map. If no exact match exists, we use the nearest node. Because the 10–05 map is dense, the matching error is at most about 2.5 mm, smaller than the typical 5–10 mm electrode diameter\n\n- **Only channel names are available:** We map each name to its canonical coordinate in the universal map\n\n- **Only the device or montage is known:** We load the predefined channel layout for that cap (such as EPOC-14 or BioSemi-16)\n\nChannel interpolation serves a different purpose: it resamples signals onto a common montage and may alter the original measurements. EEG-X instead keeps the recorded channels unchanged and uses their physical locations to align data across devices.\n\n2- Preprocessing pipeline and denoising strategy\n\nWe thank the reviewer for identifying this. The references to ICA in Appendix C.4 are typographical errors and will be corrected. During EEG-X pretraining, the encoder receives raw EEG, while rASR is used only to generate the artifact-cleaned reconstruction target.\n\nWe agree that Table 5 should more clearly isolate the effect of rASR-generated targets. We will add the following comparison in the revised manuscript:\n\n| Setting | STEW | DREAMER | TUAB | TUEV |\n|---|---:|---:|---:|---:|\n| Supervised (Raw input) | 75.12 | 55.69 | 78.12 | 88.24 |\n| Supervised (rASR input) | 73.68 | 56.41 | 78.32 | 83.36 |\n| Self-Supervised (Raw input with rASR target) |**80.32**|**58.14**|**81.02**| **91.15** |\n\nUsing rASR only to generate the reconstruction target performs best across all datasets, showing that it is more effective as denoising supervision than as direct input preprocessing.\n\n3- Interpretability of the DiCT loss formulation.\n\nThe notation \\(W^{(d)}\\), illustrated in Fig. 1, denotes the bank of convolution kernels with dilation \\(d\\). We agree that this notation should also be defined explicitly in the text.\n\nDiCT does not preserve the original signal dimensionality. Instead, it projects each signal into a dictionary-style feature representation whose size depends on the number of kernels, dilation values, and kernel groups. The reconstructed signal and target signal are transformed using the same fixed dictionary, and the loss compares their resulting feature representations. Figure 3 illustrates MSE’s sensitivity to amplitude and frequency differences, while Figure 5 extends this analysis to temporal or phase shifts. \n\nWe will revise the notation, clarify the role of dilation and the output dimensionality, and explicitly explain the relationship between Figures 3 and 5.\n\n4- Interpretation of the experimental gains\n\nWe performed pairwise two-sided Wilcoxon signed-rank tests on all matched results, using five runs per dataset and method, followed by Holm correction for multiple comparisons. For the in-domain results in Table 2, EEG-X achieved the highest average rank. However, its differences from REVE and ST-EEGFormer were not significant after correction, while its improvements over all other baselines were statistically significant.\n\n| Setting | REVE | ST-EEGFormer | EEG2Rep | CBraMod | LaBraM | EEGPT | BioT | MAEEG |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|\n| In-domain adjusted p-value | 0.5324 |0.1700 | 0.0264 | 0.0056 | 0.0036 | 0.0036 | 0.0036 | 0.0036 |\n\nFor the cross-domain results in Table 3, EEG-X ranked first and was significantly better than every competing method after Holm correction. The adjusted p-value was 0.0021 for all comparisons.\n\n5- Clarification of ablation studies\n\nTable 4 is intended to isolate the contribution of each EEG-X component by removing or replacing one component at a time.\n- **×DiCT** means that DiCT is removed and the reconstructed signal is compared with the target using standard MSE in the signal space.\n- **×CE** means that the channel embedding is removed entirely.\n- **✓CE** denotes a learnable channel embedding.\n- **Location-based CE** denotes our proposed coordinate-based channel embedding.\nThe results show that learnable channel embeddings improve performance over using no channel embedding, while our location-based embedding performs best, particularly in the cross-domain setting. Likewise, replacing DiCT with signal-space MSE reduces performance, demonstrating the independent contribution of the DiCT loss."+ },+ "createdAt": "2026-07-30T13:00:58.621Z",+ "modifiedAt": "2026-11-19T17:01:36.797Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=tNaxKChuFm",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/xbu5hrxpfo.json added
+++ b/reviews/openreview/uhwoajpteg/notes/xbu5hrxpfo.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "xbu5HRXPFo",+ "replyTo": "tapYaPpMLK",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the thoughtful feedback and for highlighting the strengths of DiCT, the broad evaluation, and the ablation study. We appreciate the concerns raised and address them below.\n\n**W1 — Comparison with REVE**\n\nUnlike REVE, which combines spatial coordinates and temporal position in a single joint Fourier encoding, EEG-X encodes each scalp coordinate separately and then combines the resulting spatial representation with the temporal position embedding. This ensures that each spatial axis contributes explicitly to the channel representation, which is important for generating similar embeddings for adjacent electrodes, especially when the embedding dimension is small.\n\nTo compare the two approaches directly, we replaced our channel embedding with the REVE encoding while keeping the EEG-X backbone, embedding dimension $(d_e=16)$, and training setup unchanged. Our location-based channel embedding achieved better results on STEW:\n\n| Channel embedding | Accuracy | AUROC |\n|---|---:|---:|\n| EEG-X with REVE encoding | 85.93 | 92.12 |\n| EEG-X with our encoding | **86.89** | **93.51** |\n\nThe main difference becomes apparent in compact embedding settings, such as $d_e \\in \\{16,32,64\\}$. REVE forms joint frequency combinations over $(x,y,z,t)$. For example, with $d_e=16$ and two frequency values per coordinate, there are $2^4=16$ possible joint phase combinations before applying sine and cosine. However, only eight phase components can be retained, producing eight sine and eight cosine values. Because these joint components are truncated, the retained subset may not represent all coordinate axes equally. In this example, the $x$-axis may be poorly represented or omitted. As a result, electrodes may appear similar mainly because they share a similar $y$-coordinate, even when they are separated along the $x$-axis. This reduces sensitivity to the true spatial adjacency of the electrodes.\n\nFor example, using a 64-channel montage and taking F4 as the reference electrode, the REVE-style encoding assigns high similarity to F3, F2, F1, and Fz. Although these electrodes have similar $y$-coordinates, they are not necessarily the closest spatial neighbours when differences along the $x$-axis are considered. In contrast, our embedding assigns the highest similarity to nearby electrodes such as F2, F6, FC4, and AF4.\n\n**W2 — Handling unseen electrodes**\n\nTable 3 evaluates transfer from pretraining on the 19-channel TUAB dataset to frozen-encoder linear probing on datasets with 8-, 14-, 22-, and 64-channel montages, with only limited electrode overlap. EEG-X consistently achieves the best performance across these settings. As shown in the Table 4 ablation study, removing the location-based embedding reduces average performance by 1.16 points in-domain and 7.67 points cross-domain, demonstrating its importance for generalization to unseen electrode layouts.\n\n**W3 — Statistical test**\n\nWe performed pairwise two-sided Wilcoxon signed-rank tests on all matched results, using five runs per dataset and method, followed by Holm correction for multiple comparisons. For the in-domain results in Table 2, EEG-X achieved the highest average rank. However, its differences from REVE and ST-EEGFormer were not significant after correction, while its improvements over all other baselines were statistically significant.\n\n| Setting | REVE | ST-EEGFormer | EEG2Rep | CBraMod | LaBraM | EEGPT | BioT | MAEEG |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|\n| In-domain adjusted p-value | 0.5324 | 0.1700 | 0.0264 | 0.0056 | 0.0036 | 0.0036 | 0.0036 | 0.0036 |\n\nFor the cross-domain results in Table 3, EEG-X ranked first and was significantly better than every competing method after Holm correction. The adjusted p-value was 0.0021 for all comparisons. We will add this analysis to the revised manuscript and report mean and standard deviation for the ablations in Tables 4 and 5.",+ "title": "Response to Reviewer cbFB (1/2)"+ },+ "createdAt": "2026-07-29T13:34:30.259Z",+ "modifiedAt": "2026-11-19T17:01:36.909Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=xbu5HRXPFo",+ "license": "CC-BY-4.0"+}
reviews/openreview/uhwoajpteg/notes/y2whmkaear.json added
+++ b/reviews/openreview/uhwoajpteg/notes/y2whmkaear.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Y2WHmkAear",+ "replyTo": "qHKGiIQSro",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Meta-Review (2/2)",+ "comment": "**4. Presentation and Notation of DiCT**\n\nWe clarified the notation and dimensionality of the DiCT module. In particular, $W^{(d)}$ denotes the bank of convolution kernels with dilation $d$. DiCT does not concatenate reconstructions to preserve the original signal dimensionality. Instead, both the reconstructed signal and the target signal are projected into the same dictionary-style feature space, whose size depends on the number of kernels, dilation values, and kernel groups. The loss is then computed between these two feature representations.\n\nWe will clarify the intermediate notation and kernel-group combination, and correct all figure references.\n\n\n\n**5. Differentiation from Prior Work**\n\nWe clarified that EEG-X differs from REVE through a factorized formulation: each scalp coordinate is encoded independently, while temporal position is encoded separately. We showed that this formulation better preserves similarity among neighbouring electrodes, particularly in low-dimensional embedding regimes. In contrast, REVE combines the coordinates through a joint encoding. Under a low-dimensional embedding, the coordinate axes may not be represented evenly, and some axes may be omitted after truncation. This can reduce sensitivity to electrode differences along those directions.\n\n\nTo isolate this difference, we replaced our channel encoding with REVE's encoding while keeping the EEG-X backbone, $d_e=16$, and the training setup unchanged:\n\n| Channel embedding | Accuracy | AUROC |\n|---|---:|---:|\n| EEG-X with REVE encoding | 85.93 | 92.12 |\n| EEG-X with our encoding | **86.89** | **93.51** |\n\n**Summary**\n\nWe hope these additional experiments and clarifications address the concerns raised by the AC and reviewers. Reviewer zaCL has already acknowledged that our response provided useful clarifications. We remain happy to address any further questions during the remaining discussion period."+ },+ "createdAt": "2026-08-03T03:59:46.682Z",+ "modifiedAt": "2026-11-19T17:01:36.862Z",+ "url": "https://openreview.net/forum?id=UHwOAjPtEg¬eId=Y2WHmkAear",+ "license": "CC-BY-4.0"+}