HandXFM: Semantic-Structural Distillation for Hand Radiograph Foundation Models
Update NeurIPS 2026 submission fKr07Pdg6F: 23 notes
@openreview[bot] · 2026-11-24 15:53 UTC · 5cd92f70af8e ·
reviews/openreview/fkr07pdg6f/notes/3kbwpfjt1j.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/3kbwpfjt1j.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "3KBwPfjt1J",+ "replyTo": "ok3lOKjpUN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **W4. Quantitative interpretability and qualitative examples**\n\n**Response:** Quantitative interpretability evaluation aims to assess whether the learned representations encode clinically meaningful semantic information through accurate text–region correspondence. Such evaluation requires a sufficiently large benchmark with paired text queries and region-level correspondence annotations. Given the limited scale of the current VQA dataset, the manuscript instead presents cross-attention heatmaps as qualitative evidence of semantic cross-modal alignment rather than quantitative interpretability metrics.\n\nThe manuscript already includes representative visualizations for joint detection, bone segmentation, and text–image attention, with additional downstream examples provided in the Supplement. \n\nAs larger hand-radiograph VQA datasets become available, quantitative text–region alignment evaluation (e.g., pointing-game accuracy or localization faithfulness) will become feasible and provide a more rigorous assessment of semantic alignment.\n\n---\n\nWe thank the reviewer again. These revisions will substantially improve transparency regarding the pretraining data, objective design, annotation quality, and the scope of our segmentation and interpretability evidence."+ },+ "createdAt": "2026-07-31T13:41:16.475Z",+ "modifiedAt": "2026-11-19T16:54:30.686Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=3KBwPfjt1J",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/5cfhia32zc.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/5cfhia32zc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "5cFHIa32ZC",+ "replyTo": "SNQpFApjZG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer zCn7",+ "content": {+ "title": "Response to Authors",+ "comment": "Thank you, author, for providing your rebuttal. Most of my concerns are addressed, except for the performance of medical semantic segmentation models, U-Net, and nnU-Net, or medical pretraining, which are not strong enough to demonstrate the strengths of pre-trained models. However, consider overall other experiments and contributions of the paper, I would keep my current positive rating."+ },+ "createdAt": "2026-08-04T10:15:40.687Z",+ "modifiedAt": "2026-11-19T16:54:29.540Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=5cFHIa32ZC",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/67yuph37wz.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/67yuph37wz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "67yUpH37WZ",+ "replyTo": "yGYm6cyRtH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 4mKQ",+ "content": {+ "title": "Thank you for your rebuttal",+ "comment": "Thank you for the very thorough rebuttal and the evident effort and time that went into it. The additional analyses address my main concerns and provide substantially stronger justification for the proposed pipeline.\n\nIn particular, Tables R2, R3, and R4 offer more convincing evidence that the combination of teachers, objectives, and edge-aware masking contributes to the overall performance. I would still recommend being cautious when interpreting these results causally: the ablations support the proposed explanation, but further analysis would be needed to establish more generally why each component produces these gains. This is naturally beyond the scope of your work, but the final manuscript should avoid claims broader than the presented evidence.\n\nI also reconsidered my earlier criticism of the VQA evaluation. Under the correct Use-Inspired framing, it provides a useful additional test of whether the learned representations transfer to a distinct multimodal task, even if it is not intended as a comprehensive VQA contribution.\n\nMore broadly, for systems that combine several models and design components, I always consider important to demonstrate what each component contributes rather than relying only on seen improvements in aggregate metrics (which can be misleading). This is particularly important in clinical applications, where simplicity, efficiency, and clear justification of each component should remain priorities.\n\nOverall, the rebuttal addressed the main gaps I identified in the evaluation and methodological justification. The hand X-ray application is well motivated as a Use-Inspired contribution, and incorporating these clarifications and results into the final manuscript will substantially strengthen the paper. I have updated my score accordingly."+ },+ "createdAt": "2026-08-02T10:32:19.592Z",+ "modifiedAt": "2026-11-19T16:54:30.209Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=67yUpH37WZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/akrdvmpln1.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/akrdvmpln1.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "AkrdVMpLn1",+ "replyTo": "MHI0zh1ZLc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer u6Li,\n\nAs the discussion period concludes, we would appreciate your feedback on whether our rebuttal and additional experiments have addressed your main concerns.\nShould any concern remain central to your assessment, we would be grateful if you could identify it so that we may clarify it directly. If our response has resolved your concerns, we would also appreciate your reconsideration of the assessment.\n\nThank you again for your time and thoughtful evaluation.\n\nThanks\n\nThe Authors"+ },+ "createdAt": "2026-08-03T04:17:39.176Z",+ "modifiedAt": "2026-11-19T16:54:30.159Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=AkrdVMpLn1",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/au9ckou8ix.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/au9ckou8ix.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Au9cKOU8iX",+ "replyTo": "fPJXb2dnfN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 4mKQ",+ "content": {+ "title": "Update of review based on correct contribution type",+ "comment": "I have updated my review to reflect that the submission is categorized as a Use-Inspired contribution rather than a General contribution. I am now placing greater weight on the clinical motivation, the curation of a large hand X-ray dataset, the breadth of clinically relevant downstream tasks, and the value of developing a reusable model for an underserved radiological domain. My main technical questions and overall recommendation remain similar, but I will reframe the discussion to focus more directly on whether the proposed design choices are sufficiently justified and validated for the intended clinical application."+ },+ "createdAt": "2026-07-31T10:49:38.401Z",+ "modifiedAt": "2026-11-19T16:54:30.433Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=Au9cKOU8iX",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/dpvteaqjsq.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/dpvteaqjsq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "dpvteaQJsq",+ "replyTo": "T5u1mZGjTd",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **Q2: The proposed alignment uses only two experts, making “multi-expert” somewhat overstated.**\n\n**Response:** We agree. The implemented model uses exactly two frozen teacher encoders. We will therefore use dual-teacher or two-teacher throughout the abstract, empirical sections, figure captions, and conclusions. The term multi-teacher will appear only when describing the general mathematical notation with J teachers, and we will explicitly state that all experiments use J = 2.\n\nWe will also remove the implication that the teachers form a clean semantic/structural decomposition. BiomedCLIP contributes a visual representation shaped by biomedical image-text pretraining, while the chest model contributes a representation shaped by radiograph-domain classification. HandXFM uses visual tokens from both and does not identify a purely semantic or purely structural factor. The teacher ablations support different and partially complementary transfer profiles, not factor identifiability.\n\n---\n\n### **Q3: Limited representation analysis. Little evidence that the proposed framework learns better representations.**\n\n**Response:** We agree that end-to-end downstream performance alone does not isolate the quality of the pretrained representation. **We therefore provide complementary evidence from a matched same-corpus control, a frozen-backbone probe, external transfer to an excluded dataset, and label-free feature-space diagnostics.** We base our main representation-quality claim on the first three analyses and treat the feature-space analyses as descriptive evidence rather than standalone proof that a particular geometry is intrinsically better.\n\n#### (1) Same-backbone, same-corpus control\n\nTo distinguish the effect of the HandXFM pretraining formulation from the effect of simply exposing DINOv3 to hand-radiograph data, we compared native DINOv3, DINOv3 continually adapted on the same hand-radiograph corpus, and HandXFM using the same downstream localization architecture and evaluation protocol.\n\n**Table R1. Same-corpus control on 17-class joint detection.**\n\n| Method | [email protected]:0.95 | [email protected] |\n|:---|---:|---:|\n| DINOv3 (native) | 0.5857 | 0.6512 |\n| DINOv3 (same-corpus adapted) | 0.5900 | 0.6487 |\n| **HandXFM** | **0.7636** | **0.9026** |\n\nContinued DINOv3 adaptation on the same corpus produces only a small change relative to native DINOv3, whereas HandXFM improves [email protected]:0.95 from 0.5900 to 0.7636 and [email protected] from 0.6487 to 0.9026 relative to the same-corpus DINOv3 control. This result indicates that, for the evaluated localization task, HandXFM’s improvement cannot be explained solely by additional exposure to hand-radiograph images and instead supports the contribution of its pretraining formulation. We restrict this conclusion to the matched localization setting and do not assume that the same margin necessarily holds for every downstream task.\n\n#### (2) Frozen-backbone probe\n\nWe next evaluated whether clinically relevant information is directly accessible from the learned representation without updating the encoder. On the Anhui whole-hand SvH scoring task, each visual backbone was frozen and only the same lightweight regression head was trained.\n\n**Table R2. Frozen-backbone evaluation on Anhui whole-hand SvH scoring.**\n\n| Frozen backbone | PCC | $R^2$ |\n|:---|---:|---:|\n| ResNet-50 | 0.602 | 0.290 |\n| RadFM | 0.521 | 0.236 |\n| RadCLIP | 0.654 | 0.241 |\n| **HandXFM** | **0.684** | **0.333** |\n\nAmong the evaluated frozen baselines, HandXFM achieves the highest PCC and $R^2$. Because the encoders remain fixed and the downstream head is held constant, this result supports that HandXFM makes information relevant to radiologist-assigned SvH severity more directly accessible to a lightweight predictor. We interpret this as supportive frozen-representation evidence rather than attributing the result to any particular geometric property of the feature space."+ },+ "createdAt": "2026-07-31T13:59:58.023Z",+ "modifiedAt": "2026-11-19T16:54:30.424Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=dpvteaQJsq",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/ewuspg4bvb.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/ewuspg4bvb.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ewUSpg4BvB",+ "replyTo": "Au9cKOU8iX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the thoughtful comments, for recognizing the clinical importance of developing a reusable foundation model for hand radiographs, and for updating the review to reflect the paper’s Use-Inspired contribution type. We understand that the reviewer’s main remaining concern is whether the proposed design choices are sufficiently motivated and validated for the intended hand-radiograph application. We therefore begin with a high-level summary of the key constraints in this domain, how each component of HandXFM is designed to address them, and the evidence supporting these choices. We then respond to the reviewer’s specific weaknesses and questions in detail.\n\n**Table R1. Use-case-driven design and validation of HandXFM.**\n| Use-case constraint | Design response | Direct validation |\n|:---|:---|:---|\n| Scarce, fragmented public hand X-rays and no large hand-specific teacher | Continuous supervision from two complementary frozen experts | Teacher-composition ablations; same-corpus DINOv3 control |\n| Extremely limited paired hand image–text data | Biomedical semantic transfer from BiomedCLIP | Teacher ablations and VQA |\n| Fine cortical margins, joint spaces, and bone boundaries | Edge-aware masked latent prediction | Random vs. edge-aware masking |\n| One encoder must support both global prediction and local localization | Visible-token alignment + masked latent reconstruction | Objective ablations across classification, detection, and segmentation |\n\n\n---\n\n### **Q1 and Weaknesses 1-3: Why use the chest X-ray ViT, and what does it contribute?**\n\nWe agree that the term **\"structural expert\"** was too strong. The chest model was trained for chest-radiograph classification, not for hand anatomy, boundary prediction, or segmentation. We will therefore replace this term with \"radiography-domain expert\" and avoid claiming that its knowledge is exclusively structural.\n\nThe rationale for its inclusion is modality transfer. Chest and hand radiographs differ anatomically, but they share 2D projection physics, grayscale attenuation, exposure and positioning effects, and bone-soft-tissue contrast and edge statistics. Because no comparably large hand-radiograph teacher is available, the chest model supplies a radiographic prior that is complementary to BiomedCLIP's biomedical image-text prior. Importantly, both teachers remain frozen and supervise the same DINOv3 student. Unlike chest-model initialization, which only determines the student's initial parameters, HandXFM receives continuous supervision from both frozen teachers throughout pretraining via visible-token/CLS alignment and masked latent prediction.\n\n\n**Table R2. Controlled teacher ablation. Student architecture and initialization, hand-X-ray corpus, optimization, downstream heads, and data splits are held fixed; only teacher supervision changes.**\n\n| Task | DINOv3 | BiomedCLIP | Chest | Dual |\n|:---|---:|---:|---:|---:|\n| RSNA Bone Age MAE ↓ | 9.106 | 7.885 | 8.064 | **7.343** |\n| RHPE Bone Age RMSE ↓ | 27.828 | 18.487 | 12.462 | **11.073** |\n| AIRINIIReumHands Erosion RMSE ↓ | 0.525 | 0.420 | 0.306 | **0.298** |\n| MURA AUC ↑ | 0.7405 | 0.7771 | 0.8485 | **0.8599** |\n| MURA ACC ↑ | 0.6741 | 0.6987 | 0.7768 | **0.7857** |\n| Joint Detection [email protected]:0.95 ↑ | 0.5900 | 0.5550 | 0.6017 | **0.7636** |\n| Joint Detection [email protected] ↑ | 0.6487 | 0.5810 | 0.6771 | **0.9026** |\n\nThe transfer pattern is task-dependent rather than a clean semantic/structural decomposition: BiomedCLIP is slightly stronger than the chest teacher on RSNA, whereas the chest teacher is stronger on RHPE, erosion, MURA, and joint detection. The dual-teacher model is best on all seven representative metrics. These matched ablations demonstrate distinct, task-dependent, and complementary transfer from the two teachers. Accordingly, we will avoid assigning either teacher an exclusively semantic or structural role. We will revise the paper to make that narrower conclusion explicit."+ },+ "createdAt": "2026-07-31T15:51:47.325Z",+ "modifiedAt": "2026-11-19T16:54:30.685Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=ewUSpg4BvB",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/fibhdbv4qi.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/fibhdbv4qi.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "fIBHdbV4qI",+ "replyTo": "ewUSpg4BvB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **Q2 and Weaknesses 5-6: Are the ablations diagnostic, and why is each component retained?**\n\n\nDue to the NeurIPS page limit, the main text summarizes the principal ablation findings, while the complete quantitative results are provided in the Supplementary Material. Below, we clarify the relationship between each design choice and downstream performance using representative results from the full ablation tables.\n\n#### **Dual-teacher supervision provides the most consistent cross-task transfer** \n\nThe teacher-composition results are summarized in Table R2. The single teachers exhibit different transfer behaviors, while the dual-teacher model achieves the strongest overall performance across regression, classification, and localization tasks. The chest teacher is particularly competitive on structure-sensitive tasks, whereas their integration produces the most reusable representation across heterogeneous downstream settings.\n\n\n#### **Alignment and masked latent reconstruction provide complementary representation learning signals**\n\n**Table R3: Objective Ablation**\n\n| Task / Metric | Alignment Only | Reconstruction Only | **Combined** |\n|:---|---:|---:|---:|\n| MURA AUC ↑ | 0.8413 | 0.8430 | **0.8599** |\n| MURA ACC ↑ | 0.7790 | 0.7723 | **0.7857** |\n| Joint Detection [email protected]:0.95 ↑ | 0.5765 | 0.5995 | **0.7636** |\n| Joint Detection [email protected] ↑ | 0.6230 | 0.6699 | **0.9026** |\n| Bone Segmentation Instance ACC ↑ | 0.9722 | 0.9512 | **0.9751** |\n| Bone Segmentation Localization [email protected]:0.95 ↑ | 0.5071 | 0.2444 | **0.6101** |\n| Bone Segmentation Localization [email protected] ↑ | 0.5056 | 0.0984 | **0.7030** |\n\n\nThese results show that the two objectives are complementary rather than individually dominant on every metric. Reconstruction-only is stronger on joint detection, whereas alignment-only remains stronger on several segmentation metrics. Combining both objectives yields the best classification, joint-localization, and instance-level bone-localization performance, supporting their complementary roles and producing the most reliable cross-task transfer.\n\n\n#### **Edge-aware masking produces its largest gains on localization-sensitive tasks**\n\n**Table R4: Random versus edge-aware masking**\n\n| Task / Metric | Random Masking | **Edge-aware Masking** |\n|:---|---:|---:|\n| RSNA Bone Age MAE ↓ | 7.870 | **7.343** |\n| RHPE Bone Age RMSE ↓ | 11.650 | **11.073** |\n| Anhui SvH RMSE ↓ | 21.402 | **18.231** |\n| MURA AUC ↑ | 0.7739 | **0.8599** |\n| MURA ACC ↑ | 0.7098 | **0.7857** |\n| Joint Detection [email protected]:0.95 ↑ | 0.7125 | **0.7636** |\n| Joint Detection [email protected] ↑ | 0.8485 | **0.9026** |\n| Bone Segmentation Localization [email protected]:0.95 ↑ | 0.4680 | **0.6101** |\n| Bone Segmentation Localization [email protected] ↑ | 0.4617 | **0.7030** |\n\nEdge-aware masking improves every representative metric, with the largest absolute gains on bone-segmentation localization: [email protected]:0.95 by **0.1421** and [email protected] by **0.2413**. This directly supports the use-case motivation that edge-biased reconstruction is most helpful when precise local anatomy matters; gains on global regression are smaller.The goal of HandXFM is to learn a general-purpose hand-radiograph foundation model rather than optimize performance for any single downstream task or metric. Therefore, each component was selected based on its ability to provide consistent improvements across diverse downstream tasks, including regression, classification, segmentation, detection, and VQA, instead of maximizing an individual benchmark.\n\nAs shown in the representative ablation results above, the final combination consistently achieves the strongest overall transfer performance across heterogeneous tasks, even though an individual teacher or component may occasionally perform better on a specific metric. Such exceptions are primarily observed on AIRINIIReumHands, which contains only 240 training images and is therefore substantially more susceptible to optimization variance. To assess the stability of these observations, we additionally conducted a five-seed evaluation (Table B18). Across repeated experiments, the complete HandXFM consistently achieves the best mean performance for both erosion (RMSE 0.3201, MAE 0.1236, $R^2$ 0.6672, PCC 0.9568) and JSN (RMSE 0.7067, $R^2$ 0.5810, PCC 0.8844), indicating that the isolated single-run improvements of individual components do not reflect a systematic advantage over the complete framework."+ },+ "createdAt": "2026-07-31T15:52:40.830Z",+ "modifiedAt": "2026-11-19T16:54:30.473Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=fIBHdbV4qI",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/gmpghoslpm.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/gmpghoslpm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "GMPgHoSlpm",+ "replyTo": "9HD8eiCsqa",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the reviewer for the constructive feedback and positive evaluation. We address each comment below.\n\n---\n\n### **Q1: L.80 – Why does a hand X-ray image have three channels?**\n\n**Response:** The notation $x\\in\\mathbb{R}^{3\\times224\\times224}$ describes the standardized model input, not the physical number of channels produced during X-ray acquisition. The multi-source corpus contains images stored in different formats. Anhui RA and MedPix images are natively stored as RGB, whereas RSNA, RHPE, MURA, and AIRINIIReumHands contain grayscale images. For grayscale radiographs, the single channel is replicated across R, G, and B. This standardization is required because all three pretrained ViT backbones (DINOv3, BiomedCLIP, and the chest-X-ray ViT) accept three-channel inputs. Supplementary A.2 already states that all images are read as RGB; the intended meaning is therefore input-format compatibility rather than color information in the radiograph.\n\n---\n\n### **Q2: L.83 – Please clarify what is meant by \"frozen medical experts.\"**\n\n**Response:** “Frozen” means that the expert parameters remain fixed throughout HandXFM pretraining and receive no gradient updates. The two experts are:\n\n1. the BiomedCLIP ViT-B/16 visual encoder, whose representation was shaped by biomedical image–text contrastive pretraining; and\n2. a chest-X-ray ViT-B/16, which supplies complementary radiography-domain appearance and structural priors.\n\nOnly the HandXFM student encoder, expert-specific projection layers, and masked latent regressor are optimized. Supplementary A.1 specifies the expert checkpoints, their original training data, and that both teachers are kept frozen and used only to generate latent targets.\n\nHere, “medical expert” denotes a domain-pretrained model used as a fixed source of latent supervision; it does not refer to a human clinician or a downstream task-specific oracle.\n\n\n---\n\n### **Q3: It would be helpful to illustrate the model's failure modes in more detail.**\n\n**Response:** The current manuscript provides two complementary forms of evidence about model limitations: qualitative VQA cases in Supplementary B.9 and quantitative multi-seed stability analysis on the small AIRINIIReumHands dataset in Table B18. We clarify what each reveals below.\n\n**1. Fine-grained reasoning limitations of the lightweight VQA adapter.** \nSupplementary B.9 presents four VQA examples corresponding to confident success, ambiguous correctness, a close call, and failure. In the failure case, the model does not reliably distinguish pure dislocation from fracture-associated cortical disruption. This distinction requires reasoning about fine-grained local geometry and cortical continuity. The lightweight VQA adapter performs global cross-attention over HandXFM patch tokens but does not explicitly condition on detected joints or segmented bones, which can limit such relational reasoning.\n\nThis failure does not indicate that the backbone lacks spatial information. Using the same pretrained encoder, HandXFM achieves [email protected] \\(=0.9026\\) for joint detection and [email protected]:0.95 \\(=0.6101\\) for bone segmentation in Table 3. The evidence instead suggests that the generic VQA adapter does not always translate the backbone’s structural representation into the precise reasoning required by the question.\n\n**2. Instability under very limited downstream supervision.** \nAIRINIIReumHands contains only 330 radiographs. Rather than relying on a single-run result, Table B18 reports performance across five random seeds. For JSN prediction, HandXFM obtains mean PCC \\(=0.8844\\) with standard deviation \\(=0.0216\\), compared with standard deviations of \\(0.0244\\) for RheumaVIT and \\(0.0865\\) for RadCLIP. HandXFM remains the strongest and comparatively stable method, but the residual variation shows that downstream performance on very small datasets remains sensitive to initialization and sampling.\n\nThese results identify two distinct limitations: the lightweight VQA head can fail on questions requiring explicit fine-grained anatomical relations, while tasks with very limited labeled data retain measurable training variability. \n\n---\n\n### **Q4: Figure B3 – Please display all images in their proper aspect ratio.**\n\n**Response:** We will regenerate Figure B3 with proper aspect ratio preservation, adjust the size of each example image, and reorganize the grid layout to ensure all anatomical structures are clearly visible and correctly proportioned.\n\n---"+ },+ "createdAt": "2026-07-31T13:29:12.054Z",+ "modifiedAt": "2026-11-19T16:54:30.124Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=GMPgHoSlpm",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/hdkzjagpsy.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/hdkzjagpsy.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "HdKZjagPsy",+ "replyTo": "T5u1mZGjTd",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer u6Li",+ "content": {+ "title": "Little Novelty",+ "comment": "Thank you for your comment. However, the authors have not addressed my main concern. In my view, this paper offers very little novelty. Although the authors argue that their work falls into the category of use-inspired research, this does not justify overlooking the novelty requirement simply because of its intended category. From my perspective, the level of novelty is still far from what I would expect for a NeurIPS paper."+ },+ "createdAt": "2026-08-04T12:31:27.097Z",+ "modifiedAt": "2026-11-19T16:54:29.463Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=HdKZjagPsy",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/l7dwuvitp9.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/l7dwuvitp9.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "L7dWUviTP9",+ "replyTo": "x1OxF01I5Z",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **3. Evaluation Fairness and Data Exposure**\n\nAs detailed in our response to **Reviewer 4mKQ, Question 3, Table R8**, we provide a consolidated data-allocation table specifying, for every source, the images used for unlabeled pretraining, downstream fitting, validation, testing, and external evaluation. HandXFM pretraining uses only the designated training partitions and never includes validation, test, or external-evaluation images. It may include downstream training images without their labels, which we will state explicitly. Official patient- or study-level partitions are preserved wherever they are provided. For the few datasets without patient identifiers or official patient-level partitions, the source datasets contain one image per patient and use the random splitting protocol defined in the original dataset release. These allocation rules prevent overlap between pretraining and evaluation images.\n\nFor all foundation-model comparisons, the evaluated models use the same downstream datasets, data partitions, input resolution, task head, evaluation implementation, and hyperparameter-selection budget. The Appendix already reports the exact checkpoints, architectures, parameter counts, native pretraining sources, and pretraining objectives of the evaluated baselines. All reported baseline results are obtained on the same benchmark datasets, data splits, and evaluation protocols as HandXFM.\n\nWe agree that ordinary downstream comparisons among models pretrained on different corpora cannot isolate the effect of the HandXFM objective. We therefore distinguish matched same-corpus controls from comparisons involving models with different native pretraining data and objectives. In the same-corpus localization control (see **Table R1** in our response to **Reviewer u6Li, Question 3**), native DINOv3 obtains joint-detection [email protected]:0.95 of 0.5857, continued hand-corpus adaptation obtains 0.5900, and HandXFM obtains 0.7636; at [email protected], the matched comparison is 0.6487 versus 0.9026. This result shows that access to the hand-radiograph corpus alone does not explain the localization gain. We explicitly limit this conclusion to the evaluated localization task rather than generalizing it to all downstream benchmarks.\n\nWe also report fully external transfer to the Digital Hand Atlas (see **Table R3** in our response to **Reviewer u6Li**, Question 3), which is excluded from HandXFM pretraining and downstream fitting. After training on RSNA and applying the model to DHA without DHA adaptation, HandXFM achieves RMSE 1.269, MAE 0.990, ($R^2$ = 0.930), and PCC 0.965, outperforming DINOv3, RadFM, and RadCLIP on every reported metric. The matched frozen-backbone analysis further compares HandXFM with DINOv3 under the same probing protocol, providing evidence about the clinical information directly accessible from the learned representations without updating either encoder.\n\nIn summary, the revision makes substantive corrections rather than merely changing terminology: it narrows the novelty claim to the domain-specific formulation and resource; replaces the semantic/structural decomposition with the empirically supported conclusion of complementary medical visual priors; and makes data exposure, baseline provenance, matched controls, leakage control, external transfer, and remaining limitations explicit.\n\nThe numerical results referenced above are supported by the manuscript’s principal and supplementary tables."+ },+ "createdAt": "2026-07-31T16:34:48.976Z",+ "modifiedAt": "2026-11-19T16:54:29.703Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=L7dWUviTP9",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/mhi0zh1zlc.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/mhi0zh1zlc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MHI0zh1ZLc",+ "replyTo": "T5u1mZGjTd",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "#### (3) External transfer to an excluded dataset\n\nWe further evaluated whether the learned representation transfers across datasets. The bone-age models were trained on RSNA and evaluated directly on the Digital Hand Atlas (DHA), which was excluded from both pretraining and downstream fitting, without any DHA-specific adaptation.\n\n**Table R3. External transfer evaluation.**\n\n| Model | RMSE ↓ | MAE ↓ | $R^2$ ↑ | PCC ↑ |\n|:---|---:|---:|---:|---:|\n| DINOv3 | 1.909 | 1.418 | 0.842 | 0.930 |\n| RadFM | 1.799 | 1.365 | 0.859 | 0.929 |\n| RadCLIP | 1.864 | 1.420 | 0.849 | 0.931 |\n| **HandXFM** | **1.269** | **0.990** | **0.930** | **0.965** |\n\nHandXFM achieves the lowest RMSE and MAE and the highest $R^2$ and PCC. The lower absolute errors indicate more accurate bone-age prediction under dataset shift, while the higher \\(R^2\\) and PCC indicate better preservation of skeletal-age variation and subject ordering. These results provide complementary evidence that the representation learned by HandXFM supports stronger transfer to an excluded data distribution.\n\n#### (4) Label-free feature-space analyses\n\nWe further conducted two label-free analyses of the frozen representations: a singular-value spectrum analysis and a patch-feature projection analysis.\n\nHandXFM shows a more concentrated singular-value spectrum than the matched DINOv3 architecture, with \\(k_{90}\\) values of 36 versus 42 for CLS features and 282 versus 500 for patch features. We interpret this result as evidence that HandXFM changes the spectral organization of the feature space, rather than that lower effective rank is inherently better. In the revised manuscript, we will use squared singular values when reporting explained variance and include feature-variance and anisotropy diagnostics.\n\nFor the patch-feature analysis, we L2-normalized the extracted patch tokens, sampled 10,000 tokens per model using the same random seed, reduced them to 50 dimensions with PCA, and generated two-dimensional t-SNE projections using identical settings. HandXFM retains 94.76% of the normalized variance within the first 50 principal components, compared with 83.89% for DINOv3 and 88.98% for RadCLIP. It also achieves comparable near-ceiling trustworthiness and, under the same projection protocol, a larger projected extent with a lower scale-normalized 30-nearest-neighbor distance.\n\nThese results are consistent with a more concentrated feature spectrum and a patch-feature projection that is globally broader while retaining relatively compact local neighborhoods. Because t-SNE embeddings do not have an intrinsically calibrated global scale, the projection-based statistics are interpreted under the shared analysis protocol.\n\nTaken together, these analyses provide evidence beyond end-to-end fitting: HandXFM retains more accessible clinically relevant information when frozen, transfers more effectively to an excluded external dataset, and outperforms a same-backbone, same-data DINOv3 control under a matched localization protocol. The label-free analyses further reveal a more concentrated feature spectrum and, under the shared projection protocol, broader patch-feature coverage with relatively compact local neighborhoods. These additional analyses will be incorporated into the revised manuscript.\n\n---\nWe thank the reviewer for this valuable suggestion. These additional analyses will be incorporated into the revised manuscript to provide more direct evidence of the learned representations."+ },+ "createdAt": "2026-07-31T14:02:13.898Z",+ "modifiedAt": "2026-11-19T16:54:30.426Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=MHI0zh1ZLc",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/ok3lokjpun.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/ok3lokjpun.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ok3lOKjpUN",+ "replyTo": "WBeGbjm4Vd",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the positive assessment of HandXFM’s clinical relevance, technical coherence, broad multi-task evaluation, and cross-dataset generalization. We respond to each concern below.\n\n---\n\n### **W1. Semantic supervision from BiomedCLIP**\n\n**Response:** HandXFM transfers semantic knowledge by distilling the **BiomedCLIP visual encoder**, rather than introducing an additional text-conditioned objective during pretraining. This design is motivated by the scarcity of paired hand image–text data and allows the model to inherit semantic representations learned from large-scale biomedical image–text pretraining while remaining applicable to large collections of unlabeled hand radiographs.\n\nThe semantic supervision therefore originates from the representation learned by the frozen BiomedCLIP image encoder during biomedical image–text contrastive pretraining. HandXFM distills these language-aligned visual representations into the student encoder, while the radiograph-pretrained ViT contributes complementary structural knowledge specific to projection radiography.\n\nThis design is also reflected in the downstream VQA architecture. HandXFM combines its visual encoder with the frozen BiomedCLIP text encoder through a lightweight cross-attention module, followed by an MLP classifier over a predefined answer vocabulary. This design naturally follows our pretraining strategy: HandXFM is distilled toward the frozen BiomedCLIP image encoder, whose visual representations are already aligned with the corresponding BiomedCLIP text encoder. Consequently, the learned HandXFM visual representations remain compatible with the same vision-language embedding space, making the frozen BiomedCLIP text encoder a natural choice for multimodal fusion without requiring a generative language model or additional language adaptation.\n\nThe effectiveness of this semantic transfer is supported by the teacher-composition ablations (Tables B4–B7). If the semantic teacher contributed little beyond the radiographic expert, the dual-teacher model would not consistently outperform the single-teacher variants. Instead, the dual-teacher formulation consistently achieves the strongest or comparable performance across most downstream tasks, indicating that the semantic knowledge transferred from BiomedCLIP provides complementary information beyond radiographic structural representations.\n\nTo avoid possible ambiguity, we will clarify that HandXFM transfers semantic knowledge through distillation from a language-aligned visual encoder, rather than through explicit text-conditioned pretraining.\n\n---\n\n### **W 2 and Q(a). Pretraining corpus composition and leakage prevention**\n\n**Response:** Please also see our response to **Reviewer 4mKQ, Question 3**, where we provide the complete composition of the unlabeled pretraining corpus, including the image count, dataset sources, data diversity, splitting strategy, duplicate removal, and leakage-prevention protocol. Dataset demographic information (e.g., age and sex distributions, where available) is also summarized in the Appendix C.1.\n\nBriefly, HandXFM is pretrained on approximately **26K unlabeled hand radiographs** collected exclusively from the training partitions of six public datasets. All validation, test, and external evaluation images are excluded before pretraining. Patient-level splits are preserved whenever available, checksum-based duplicate detection is performed across the pretraining and downstream evaluation manifests, and the external DHA dataset is completely held out from both pretraining and model fitting.\n\nTo address the reviewer's concern regarding the \"foundation model\" claim, our objective is to learn a transferable representation for the **hand-radiograph domain**, where public data are inherently scarce and fragmented, rather than to match the scale of internet-scale or chest-radiograph foundation models. Despite this limitation, HandXFM consistently generalizes across six downstream tasks and an external dataset (DHA), indicating that the learned representation transfers beyond individual datasets.\n\n\n---"+ },+ "createdAt": "2026-07-31T13:39:11.269Z",+ "modifiedAt": "2026-11-19T16:54:30.112Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=ok3lOKjpUN",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/snqpfapjzg.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/snqpfapjzg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "SNQpFApjZG",+ "replyTo": "3KBwPfjt1J",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer zCn7,\n\nAs the discussion period concludes, we would appreciate your feedback on whether our rebuttal and additional experiments have addressed your main concerns.\nShould any concern remain central to your assessment, we would be grateful if you could identify it so that we may clarify it directly. If our response has resolved your concerns, we would also appreciate your reconsideration of the assessment.\n\nThank you again for your time and thoughtful evaluation.\n\nThanks\n\nThe Authors"+ },+ "createdAt": "2026-08-03T04:20:38.977Z",+ "modifiedAt": "2026-11-19T16:54:29.566Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=SNQpFApjZG",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/t5u1mzgjtd.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/t5u1mzgjtd.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "T5u1mZGjTd",+ "replyTo": "1aIxQPnu6w",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the careful assessment and for recognizing several strengths of HandXFM, including its integration of complementary expert knowledge through distillation and alignment, the curation of a large multi-source hand-radiograph dataset, the proposed edge-aware masking strategy, and the extensive evaluation across diverse downstream tasks. We also appreciate the reviewer’s constructive feedback regarding the scope of the methodological contribution, the terminology used for the two-teacher setting, and the need for more direct representation-level evidence. We address each of these points one by one below and describe the corresponding clarifications, additional analyses, and manuscript revisions.\n\n---\n\n### **Q1: Limited novelty.**\n\n**Response:** We first clarify that this work was submitted under the **Use-Inspired** contribution type. **Our originality claim follows the intended scope of this contribution type: the contribution lies not necessarily in introducing an entirely new primitive, but in developing a novel, application-motivated combination of methods that addresses the characteristics and requirements of a specific real-world problem.** We therefore do not claim edge-aware masking, teacher distillation, or masked latent prediction in isolation as the novelty of HandXFM.\n\nTo the best of our knowledge at the time of submission, HandXFM is the first hand-radiograph pretraining framework to jointly align visual representations from two medical teacher encoders with different pretraining sources while reconstructing masked teacher targets selected from anatomically edge-rich regions in a single student encoder. The framework is designed specifically for the hand-radiograph setting, where public pretraining data are limited and fragmented, paired hand image–text supervision is scarce, clinically relevant information is concentrated around cortical margins, joint spaces, and bone boundaries, and downstream applications require both image-level prediction and anatomically precise localization.\n\n**From a methodological perspective, the novelty lies in how these elements are formulated and integrated for this use case.** **First,** HandXFM performs both visible-token and CLS-token alignment to transfer complementary visual priors from a biomedical image–text-pretrained model and a radiograph-domain-pretrained model into one hand-radiograph encoder. **Second,** masked latent prediction is performed against teacher representations rather than raw pixels, allowing the student to learn contextual visual structure in the teachers’ latent spaces. **Third,** edge-aware masking concentrates this prediction objective on anatomically informative regions instead of allocating most masked tokens to relatively homogeneous background or soft-tissue regions. At inference, the teacher encoders and latent prediction module are removed, leaving a single reusable visual encoder.\n\n**The ablation results support that the integrated formulation provides complementary benefits across tasks.** The dual-teacher model achieves a MURA AUC of 0.8599, compared with 0.8485 and 0.7771 for the two single-teacher variants, and a joint-detection [email protected]:0.95 of 0.7636, compared with 0.6017 and 0.5550. Combining teacher alignment and masked latent reconstruction increases joint-detection [email protected]:0.95 from 0.5765 and 0.5995 for the individual objectives to 0.7636 for their combination. Replacing random masking with edge-aware masking further improves bone-segmentation localization [email protected]:0.95 from 0.4680 to 0.6101.\n\nWe will also make the limits of this claim explicit. The complete formulation is not uniformly superior on every metric; for example, the radiograph-domain single-teacher variant performs better on several JSN error measures. We therefore claim improved robustness across heterogeneous hand-radiograph tasks rather than universal dominance of every component.\n\nIn addition, **the work consolidates six fragmented public hand-radiograph datasets into a unified pretraining and evaluation resource and introduces new joint-detection and bone-segmentation annotations independently reviewed by two annotators with musculoskeletal training.** The resulting evaluation covers regression, classification, detection, segmentation, visual question answering, and external transfer.\n\nAccordingly, the contribution is not edge-aware masking or any other established component alone. It is a **use-inspired hand-radiograph pretraining formulation that combines complementary medical visual priors, global and local representation alignment, and anatomically guided latent prediction**, together with a comprehensive evaluation resource for studying transfer across diverse hand-radiograph applications. We will revise the Introduction and Related Work to state this scope more precisely and more clearly acknowledge the precedents of the individual techniques."+ },+ "createdAt": "2026-07-31T13:57:51.199Z",+ "modifiedAt": "2026-11-19T16:54:29.966Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=T5u1mZGjTd",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/ttzihyhnwh.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/ttzihyhnwh.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "tTziHYHNWh",+ "replyTo": "GMPgHoSlpm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **Q5: Please clarify which tasks and data are used for training versus held out for evaluation.**\n\n**Response:** Please refer to our response to **Reviewer 4mKQ, Q3** for the complete dataset-by-dataset split table. Briefly, pretraining uses only training splits without labels; all validation/test splits are excluded, and DHA is entirely held out for external evaluation. For the RSNA-based detection and segmentation tasks, downstream training images come from the RSNA training split and evaluation images from the disjoint validation split. Therefore, no evaluation image is used during pretraining or downstream training. This protocol is already specified in Section 4.1 and Supplementary A.2/E.2.\n\n---\n\n### **Q6: Clarify \"bridging semantic foundation models and anatomical hand analysis.\"**\n\n**Response:** It means that HandXFM distills complementary priors from BiomedCLIP and a chest-X-ray ViT into a single hand-radiograph encoder. BiomedCLIP provides medical visual features shaped by biomedical image–text pretraining, while the chest-X-ray ViT provides radiography-domain cues such as grayscale contrast, projection patterns, and bone–soft-tissue boundaries.\n\nThe student absorbs these priors through patch- and CLS-level alignment, while masked latent reconstruction and edge-aware masking encourage anatomical and boundary-sensitive representations. After pretraining, both experts are discarded, and the single HandXFM encoder transfers across regression, classification, detection, segmentation, and VQA.\n\nWe empirically evaluate the contribution of each expert through controlled ablations. The no-teacher, BiomedCLIP-only, chest-X-ray-only, and dual-expert variants use otherwise identical settings. Each expert improves over the DINOv3-only baseline, while the dual-expert model provides the most balanced performance across task families. These results support the complementarity of the two expert priors.\n\n---\n\n### **Q7: Figure 1 – Some arrows point to unclear destinations.**\n\n**Response:** We apologize for the unclear figure layout. During PDF compression, a small icon illustrating the edge strength heatmap (generated by applying a Sobel operator to the input image, as described in Section 3.3) was inadvertently dropped from Figure 1. This icon is what the arrows from \"Edge-Aware\" were intended to point to. We will restore this icon and clarify the remaining connections: the dashed arrow from EMA will connect to Consistency Loss, and all loss blocks will have unambiguous connections. We will also add a legend distinguishing solid versus dashed arrows.\n\n\n---\n\n### **Q8: Section 3.4 – Clarify whether EMA is novel or standard/prior art.**\n\n**Response:** The Exponential Moving Average (EMA) is standard prior art and is not claimed as an independently novel component. Our implementation follows established teacher–student and self-distillation frameworks, including Mean Teacher [1], BYOL [2], and DINO [3]. In HandXFM, EMA serves as a standard stabilization mechanism alongside multi-expert alignment and masked latent reconstruction. The novel component is not EMA itself, but the overall semantic–structural distillation framework and its domain-specific design for hand radiographs.\n\n**References:**\n\n[1] Antti Tarvainen and Harri Valpola. **Mean Teachers Are Better Role Models: Weight-Averaged Consistency Targets Improve Semi-Supervised Deep Learning Results.** In *Advances in Neural Information Processing Systems (NeurIPS)*, 2017.\n\n[2] Jean-Bastien Grill, Florian Strub, Florent Altché, Corentin Tallec, Pierre H. Richemond, Elena Buchatskaya, Carl Doersch, Bernardo Avila Pires, Zhaohan Daniel Guo, Mohammad Gheshlaghi Azar, Bilal Piot, Koray Kavukcuoglu, Rémi Munos, and Michal Valko. **Bootstrap Your Own Latent: A New Approach to Self-Supervised Learning.** In *Advances in Neural Information Processing Systems (NeurIPS)*, 2020.\n\n[3] Mathilde Caron, Hugo Touvron, Ishan Misra, Hervé Jégou, Julien Mairal, Piotr Bojanowski, and Armand Joulin. **Emerging Properties in Self-Supervised Vision Transformers.** In *Proceedings of the IEEE/CVF International Conference on Computer Vision (ICCV)*, 2021.\n\n---\n\nWe hope these comprehensive responses and planned revisions address all of the reviewer's concerns and further strengthen the paper. We are grateful for the reviewer's time and valuable feedback."+ },+ "createdAt": "2026-07-31T13:34:56.630Z",+ "modifiedAt": "2026-11-19T16:54:31.283Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=tTziHYHNWh",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/ulm1uc0x4g.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/ulm1uc0x4g.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ulM1uC0x4G",+ "replyTo": "x1OxF01I5Z",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **2. Interpretation of the Two Teachers**\n\nWe agree that calling the chest X-ray ViT a “structural expert” was too strong. It was trained for chest-radiograph classification, not for hand anatomy, boundary prediction, detection, or segmentation. We will rename it the **radiography-domain teacher** and will not claim that it isolates a structural latent factor.\n\nSimilarly, BiomedCLIP contributes a visual representation shaped by biomedical image–text contrastive pretraining, but HandXFM uses only its frozen visual tokens during pretraining. HandXFM therefore does not use an explicit text-conditioned loss and does not identify a purely semantic factor. We will describe BiomedCLIP more precisely as a **biomedical vision-language-pretrained visual teacher**.\n\nThe two teachers should thus be understood as differently pretrained visual priors. Their transfer profiles are not identical: the radiography-domain teacher is stronger on RHPE bone age, erosion scoring, MURA classification, and joint detection, whereas the BiomedCLIP teacher is slightly stronger on some bone-segmentation instance-classification metrics. The dual-teacher student provides the strongest overall cross-task balance. These results support nonredundant and complementary transfer behavior, not identifiability of a semantic factor and a structural factor.\n\nThe explicit structural inductive biases in HandXFM instead arise from patch-level reconstruction and the preferential masking of edge-rich regions. We will revise the title, abstract, Methods, figure caption, and conclusions accordingly. A more accurate title would be:\n\n**HandXFM: Dual-Teacher Latent Distillation for Hand Radiograph Foundation Models**"+ },+ "createdAt": "2026-07-31T16:34:35.316Z",+ "modifiedAt": "2026-11-19T16:54:30.361Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=ulM1uC0x4G",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/vecdphtib4.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/vecdphtib4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "VEcdPhTIb4",+ "replyTo": "Au9cKOU8iX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Table R8 below consolidates the use of each dataset across HandXFM pretraining, downstream fine-tuning, and evaluation. Only training images are included in the HandXFM pretraining corpus; all validation, test, and external-evaluation images are excluded.\n\n**Table R8: Dataset allocation and overlap control.**\n\n| Dataset | Task | HandXFM pretraining | Downstream fine-tuning | Validation / testing | Overlap control |\n|:--|:--|:--|:--|:--|:--|\n| **RSNA Bone Age** | Bone-age regression | Official train: **12,611 images** | Same official train split | Official validation: **1,425 images**; official test labels unavailable | Validation images excluded from pretraining and fine-tuning |\n| **RHPE** | Bone-age regression | Official train: **5,487 images** | Same official train split | Official validation: **713 images**; test: **79 images** | Validation/test images excluded from pretraining and fine-tuning |\n| **MURA Hand** | Abnormality classification | Official train: **5,543 studies**; Normal Ratio=0.268 | Same official train studies | Official validation: **460 studies** ; Normal Ratio=0.411 | Official study-level separation; validation studies excluded from pretraining |\n| **AIRINIIReumHands** | Joint-level SvH scoring | Training split only; **240 training images** | Same training split | Official validation: **60 images**; test: **30 images** | Validation/test images excluded from pretraining and fine-tuning |\n| **Anhui RA** | Whole-hand SvH scoring | Random train split: **2,700 images** | Same train split | Validation: **760**; test: **158 images** | Disjoint image-level random splits using the original split sizes |\n| **MedPix Hand** | Closed-set VQA | Training portion of **97 image–question pairs** | Same training portion | Fixed held-out **11** test pairs | Every test image excluded from pretraining |\n| **DHA** | External bone-age validation | **Not used** | **Not used**; encoder and regression head trained on RSNA | Entire dataset: **1,103 images** | Fully external; no DHA image used during pretraining or fine-tuning |\n| **Joint Detection (ours)** | 17-class detection | RSNA official train only | Annotations drawn from RSNA train | Annotations drawn from RSNA validation; **6,130 annotated images in total**, sampled from RSNA train/validation at approximately **9:1** | Pretraining and detector training use only RSNA-train images; evaluation images originate exclusively from RSNA validation |\n| **Bone Segmentation (ours)** | 19-class segmentation | RSNA official train only | Annotations drawn from RSNA train | Annotations drawn from RSNA validation; **549 annotated images in total**, following the same train/validation source separation | Pretraining and segmentation training use only RSNA-train images; evaluation images originate exclusively from RSNA validation |\n\nFor the newly annotated localization datasets, annotations inherit the official RSNA train/validation partition. Specifically, approximately 90% of the annotated images were sampled from the official training split and the remaining 10% from the official validation split. As a result, all localization models are trained only on annotations from the RSNA training split and evaluated only on annotations from the RSNA validation split, ensuring complete separation between pretraining, downstream training, and evaluation.\n\nWe strictly enforce image-level separation between pretraining and all validation/test sets. For datasets with official study- or patient-level partitions, we preserve those groupings (e.g., MURA). For datasets released without patient identifiers (e.g., Anhui), patient-level duplication cannot be independently audited beyond the official or provided splits; we will state this limitation explicitly.\n\nFor baseline comparability, unless otherwise explicitly stated, all foundation-model baselines are initialized from their respective official pretrained weights and fully fine-tuned end-to-end on the same downstream training split as HandXFM, using the same validation/test split and task-specific evaluation protocol. For detection and segmentation, the compared backbones are paired with the same DETR-based downstream architecture, so the comparison primarily reflects differences in the visual encoder. Task-specific methods whose results are taken from the original publications are reported separately on their corresponding benchmark datasets. We also include explicitly labeled controlled variants with different training protocols. In Table 3, the domain-adapted DINOv3 is additionally pretrained on exactly the same hand-radiograph corpus as HandXFM before downstream fine-tuning, directly controlling for access to in-domain pretraining data. In Table B17, all encoders are evaluated under a frozen-backbone setting on the Anhui whole-hand SvH scoring task, with only the downstream prediction head trained. These exceptions are clearly identified and are not mixed with the default end-to-end fine-tuning comparisons."+ },+ "createdAt": "2026-07-31T17:09:16.779Z",+ "modifiedAt": "2026-11-19T16:54:30.239Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=VEcdPhTIb4",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/viczzbpsth.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/viczzbpsth.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "viczZbPsTH",+ "replyTo": "ok3lOKjpUN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **Q(b). What loss weights are used, and how sensitive are the results?**\n\n**Response:** The main experiments use\n\n$\\[\n\\lambda_{\\mathrm{recon}}=1.0,\\qquad\n\\lambda_{\\mathrm{ema}}=0.01,\\qquad\n\\lambda_{\\mathrm{cls}}=0.01.\n\\]$\n\nThese values were not selected through downstream hyperparameter tuning. During preliminary pretraining, we monitored the empirical magnitudes of the four loss terms over the early training epochs. Since the reconstruction and alignment losses exhibited comparable scales, the reconstruction loss retained a unit weight. In contrast, the raw EMA and CLS losses were substantially larger despite serving as auxiliary regularization terms, and were therefore assigned weights of 0.01 to prevent them from dominating the optimization. The same loss weights were then used for all pretraining runs and downstream evaluations.\n\nA comprehensive sensitivity analysis would require independently pretraining multiple foundation models with different weight configurations and evaluating each model across all downstream tasks, which is beyond the scope of the current work. To improve reproducibility, the revised manuscript will explicitly report the loss weights, describe the calibration procedure, provide representative loss magnitudes and convergence curves, and discuss comprehensive weight sensitivity as a limitation.\n\nThe current manuscript nevertheless evaluates the more fundamental contribution of each objective through the loss-composition ablation (alignment only, reconstruction only, and the combined objective). Across regression, classification, and localization tasks, the combined objective consistently provides the most balanced performance, suggesting that the overall performance does not depend critically on any single auxiliary loss term. The exact loss weights are stated explicitly in Supplementary A.4.\n\n---\n\n### **Q(c). Please clarify the annotation and quality-assurance protocol.**\n\n**Response:** Two annotators with musculoskeletal training participated in dataset construction. One annotator produced the initial annotations, followed by joint quality review and consensus resolution by both annotators.\n\nJoint-detection annotations comprise bounding boxes for 17 anatomical landmarks defined according to *Terminologia Anatomica* and RSNA RadLex, while bone-segmentation masks include 19 anatomically defined metacarpal and phalangeal categories. \n\nAn automated quality-assurance (QA) program was used to identify potentially inconsistent annotations by checking annotation completeness, category counts, missing or duplicated labels, hand orientation, and anatomically implausible spatial relationships. Flagged cases were subsequently reviewed until consensus was reached. After annotation, an additional audit of 1,000 joint-detection images and 100 segmentation masks was independently reviewed by both annotators to verify anatomical placement and category assignment, as described in Supplementary C.2. \n\nThe dataset was annotated through consensus rather than independent duplicate annotation; consequently, inter-annotator agreement metrics such as IoU or Cohen's \\(\\kappa\\) are not available. \n\n---\n\n### **W3 and Q(d). Please compare against stronger segmentation baselines.**\n\n**Response:** Our original evaluation focused on **instance-level bone segmentation**, since HandXFM is designed to distinguish individual anatomical bones rather than only foreground pixels. This setting is directly motivated by downstream clinical tasks requiring bone-level reasoning, such as per-bone bone-age estimation and anatomical structure analysis. Accordingly, the main paper adopted COCO-style instance segmentation metrics ([email protected]:0.95) and compared against instance-aware methods (e.g., YOLOv12).\n\nTo provide a comprehensive evaluation, we additionally trained two widely used medical semantic segmentation models, **U-Net** and **nnU-Net**, on the same dataset and evaluated all methods using pixel-level metrics.\n\n**Table R1. Comparison with semantic segmentation baselines using pixel-level metrics.**\n\n| Method | Pixel ACC ↑ | Precision ↑ | Recall ↑ | F1 ↑ |\n|:---|---:|---:|---:|---:|\n| nnU-Net | 0.9587 | 0.4384 | 0.4762 | 0.4538 |\n| U-Net | **0.9597** | 0.4549 | 0.4803 | 0.4645 |\n| **HandXFM (ours)** | 0.9586 | **0.4596** | **0.4984** | **0.4777** |\n\nHandXFM achieves the best Precision, Recall, and F1 while maintaining comparable pixel accuracy to U-Net and nnU-Net. Together with its superior instance-level performance ([email protected]:0.95 = **0.6101**), these results demonstrate that HandXFM preserves strong pixel-level segmentation quality while providing explicit instance-aware anatomical representations for downstream bone-level clinical tasks.\n\nThe revised manuscript reports both **semantic segmentation metrics (Pixel ACC, Precision, Recall, and F1)** and **instance segmentation metrics (COCO mAP)**, providing a more comprehensive comparison with conventional semantic segmentation models and instance-aware approaches."+ },+ "createdAt": "2026-07-31T13:40:34.784Z",+ "modifiedAt": "2026-11-19T16:54:30.054Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=viczZbPsTH",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/wii1azfaew.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/wii1azfaew.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Wii1aZfAEW",+ "replyTo": "Au9cKOU8iX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **Q3 and Weakness 4: Data exposure, overlap control, and baseline comparability**\n\n#### **Baseline provenance and matched downstream protocol**\n\nAll foundation-model baselines use their official pretrained checkpoints and are fully fine-tuned end-to-end on the same downstream training split as HandXFM, with the same validation/test split and task-specific protocol. Detection and segmentation backbones use the same DETR-style downstream head; task-specific numbers taken from original publications are reported separately. The revised appendix will list exact checkpoint identifiers in addition to model names.\n\n**Table R5. Native pretraining provenance and comparison protocol.**\n| Model | Native pretraining source / objective | Protocol in this paper |\n|:---|:---|:---|\n| **ResNet50 / ConvNeXt-T / ViT-B/16** | Official natural-image supervised checkpoints used in our implementation; exact checkpoint identifiers and native source datasets will be stated explicitly. | Same downstream split and task head; end-to-end fine-tuning. |\n| **DINOv3 ViT-B/16** | Self-supervised/distilled visual model pretrained on the LVD-1689M web-image corpus. | Native checkpoint and a separately labeled same-hand-corpus adapted control. |\n| **RadFM** | MedMD (approximately 16M 2D/3D medical scans), followed by RadMD (approximately 3M radiology image–text pairs). | Official checkpoint; same downstream split and task head. |\n| **RadCLIP** | 1,157,587 2D and 52,766 3D radiology image–text pairs collected from 14 public sources. | Official checkpoint; same downstream split and task head. |\n| **BiomedCLIP (teacher)** | PMC-15M biomedical image–text pairs. | Frozen teacher used only during HandXFM pretraining. |\n| **Chest X-ray teacher** | ViT-B/16 fine-tuned for normal-versus-pneumonia classification on a chest X-ray dataset (12,230 / 1,165 / 582 train / validation / test images). | Frozen radiography-domain teacher used only during HandXFM pretraining. |\n| **HandXFM** | Training partitions of six public hand-radiograph datasets (approximately 26K images) using dual-expert latent alignment and masked reconstruction. | Same downstream splits and task heads as the compared encoders. |\n\n#### **Baseline control and external transfer**\n\nThe reviewer is correct that the compared foundation models were pretrained on different source data. To clarify this aspect of the evaluation, we summarize two complementary pieces of evidence already included in the manuscript: (1) a same-corpus controlled DINOv3 baseline pretrained on exactly the same hand-radiograph corpus as HandXFM, and (2) transfer performance on a fully unseen external dataset.\n\n**Table R6. Same-corpus control on 17-class joint detection.**\n\n| Method | Pretraining Data | Joint Detection (17-class) [email protected]:0.95 ↑ | [email protected] ↑ |\n|:--|:--|:--:|:--:|\n| DINOv3 (native) | Original DINOv3 | 0.5857 | 0.6512 |\n| DINOv3 (adapted) | Same hand-radiograph corpus as HandXFM | 0.5900 | 0.6487 |\n| **HandXFM** | Same hand-radiograph corpus | **0.7636** | **0.9026** |\n\nDomain-adapting DINOv3 on exactly the same hand corpus changes mAP only modestly, while HandXFM reaches 0.7636/0.9026 with the same DINOv3 initialization and pretraining images. This control shows, for this localization task, that the gain is not explained solely by access to in-domain images. We will not overgeneralize this single controlled task to every downstream benchmark.\n\n**Table R7. Direct RSNA-to-DHA external transfer. All bone-age models are trained on RSNA and evaluated on DHA without DHA adaptation; DHA is excluded from pretraining and downstream fitting.**\n\n| Model | RMSE ↓ | MAE ↓ | R² ↑ | PCC ↑ |\n|:---|---:|---:|---:|---:|\n| DINOv3 | 1.909 | 1.418 | 0.842 | 0.930 |\n| RadFM | 1.799 | 1.365 | 0.859 | 0.929 |\n| RadCLIP | 1.864 | 1.420 | 0.849 | 0.931 |\n| **HandXFM** | **1.269** | **0.990** | **0.930** | **0.965** |\n\nHandXFM also has the lowest error and highest $R^2$/PCC on the completely unseen DHA distribution. This does not eliminate every pretraining-source difference, but it shows that the advantage is not confined to images drawn from the HandXFM pretraining datasets."+ },+ "createdAt": "2026-07-31T17:08:26.376Z",+ "modifiedAt": "2026-11-19T16:54:30.597Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=Wii1aZfAEW",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/x1oxf01i5z.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/x1oxf01i5z.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "x1OxF01I5Z",+ "replyTo": "X7TyfezOAG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the Area Chair for identifying the three issues most relevant to the final discussion: the scope of novelty, the interpretation of the two teacher models, and evaluation fairness. We recognize that the original manuscript could have articulated these points more precisely. Our revisions therefore make three substantive changes: **First,** we narrow the originality claim to the domain-motivated formulation, curated resource, and comprehensive validation, rather than to the individual methodological components, which is more consistent with the paper’s Use-Inspired contribution type. **Second** we replace the semantic/structural factorization language with a more precise account of two differently pretrained and partially complementary medical visual priors. **Third,** we distinguishe matched, leakage-controlled evidence from contextual comparisons involving models with different native pretraining corpora, objectives and architectures.\n\n### **1. Scope of the Novelty Claim**\n\nHandXFM builds on established advances in teacher–student distillation, masked latent prediction, structure-aware sampling, and EMA-based representation learning. **Its originality lies in how these elements are jointly formulated and validated to address the specific challenges of hand-radiograph foundation modeling.** To describe the implemented system with greater precision, we will use dual-teacher throughout the empirical sections, while retaining the general J-teacher formulation in the Methods. All experiments reported in this submission use J=2.\n\nSpecifically, the contribution we claim is the problem-driven formulation and validation of a single hand-radiograph encoder that combines: (i) visible-patch and CLS-token alignment to two frozen medical visual encoders; (ii) prediction of masked, edge-rich latent tokens against the same teacher targets; and (iii) EMA regularization. This formulation is motivated by a coupled set of hand-radiograph constraints: public data are fragmented across six sources; paired hand image–text data are exceptionally scarce; clinically important evidence often lies in cortical margins, joint spaces, and bone boundaries; and a reusable representation must support both global tasks, such as bone age and abnormality prediction, and local tasks, such as joint detection and bone segmentation. The work additionally contributes a consolidated pretraining and evaluation resource and new 17-class joint-detection and 19-class bone-segmentation annotations, with independent musculoskeletal review of representative subsets.\n\n**The controlled ablations indicate that the formulation is not an arbitrary aggregation of standard components.** Relative to the single-teacher variants, the dual-teacher model achieves the strongest representative results on RSNA bone age (MAE 7.343), RHPE bone age (RMSE 11.073), MURA abnormality classification (AUC 0.8599), joint detection ([email protected]:0.95 of 0.7636), and bone-segmentation localization ([email protected]:0.95 of 0.6101). Combining alignment and reconstruction increases joint-detection [email protected]:0.95 from 0.5765 and 0.5995 for the individual objectives to 0.7636. Replacing random masking with edge-aware masking increases bone-segmentation localization [email protected]:0.95 from 0.4680 to 0.6101 and [email protected] from 0.4617 to 0.7030.\nThe results demonstrate that the proposed design provides the strongest overall balance across regression, classification, detection, segmentation, and external-transfer settings. Individual components retain task-specific strengths. For example, the radiography-domain single-teacher model performs particularly well on several AIRINIIReumHands JSN error measures, while random masking remains competitive on selected pixel-level segmentation metrics. These patterns further support the complementary roles of the teachers and objectives. In the revision, we will emphasize one prespecified primary metric for each task and report the complete set of secondary metrics in the appendix, providing a clear and comprehensive view of performance across tasks.\n\nThe originality of HandXFM therefore lies in its domain-motivated dual-teacher latent-distillation formulation, edge-biased masked latent prediction, and the accompanying hand-radiograph pretraining and evaluation resource. **Together, these contributions address the linked challenges of limited multimodal supervision, anatomically fine-grained radiographic structure, and heterogeneous downstream tasks within a unified encoder.** We will refine the Introduction and Related Work to position the individual components within their established literature while more clearly highlighting the novelty of their integrated formulation, domain-specific motivation, and broad empirical validation."+ },+ "createdAt": "2026-07-31T16:34:03.621Z",+ "modifiedAt": "2026-11-19T16:54:30.684Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=x1OxF01I5Z",+ "license": "CC-BY-4.0"+}
reviews/openreview/fkr07pdg6f/notes/x7tyfezoag.json modified
+++ b/reviews/openreview/fkr07pdg6f/notes/x7tyfezoag.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair FkR7","content": {- "metareview": "The reviewers recognize that the proposed method addresses an important and clinically relevant domain, and they generally appreciate the breadth of the evaluation across hand-radiograph tasks. However, the current discussion depends on several issues concerning novelty, the validity of the claimed expert decomposition, and the fairness of the evaluation. At this stage, the authors should focus the rebuttal on these issues, which are most relevant to the final discussion."+ "metareview": "The reviewers recognize that the proposed method addresses an important and clinically relevant domain, and they generally appreciate the breadth of the evaluation across hand-radiograph tasks. However, the current discussion depends on several issues concerning novelty, the validity of the claimed expert decomposition, and the fairness of the evaluation. At this stage, the authors should focus the rebuttal on these issues, which are most relevant to the final discussion.",+ "final_justification": "The submission received positive recommendations from the majority of the panel: two Accept, one Borderline Accept, and one Reject. The authors provided an extensive rebuttal, clarifying data splits, revising terminology, and providing external transfer benchmarks. Overall, considering the positive scores from three reviewers and that most of the questions are addressed by this rebuttal, the paper is recommended for acceptance."},"createdAt": "2026-07-22T06:49:08.335Z",- "modifiedAt": "2026-11-18T15:18:34.471Z",+ "modifiedAt": "2026-11-19T04:59:11.668Z","url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=X7TyfezOAG","license": "CC-BY-4.0"}
reviews/openreview/fkr07pdg6f/notes/ygym6cyrth.json added
+++ b/reviews/openreview/fkr07pdg6f/notes/ygym6cyrth.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "yGYm6cyRtH",+ "replyTo": "Au9cKOU8iX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### **Q4, Weaknesses 7-8, and Limitations: Attention maps, VQA, and scope of claims**\n\n#### **Cross-attention visualizations provide qualitative evidence of cross-modal alignment**\n\nWe agree that attention maps should not be interpreted as faithful explanations of model decision-making. Our intention was not to claim causal interpretability, but rather to qualitatively demonstrate that the representations learned by HandXFM encode clinically meaningful semantic information. In the illustrative examples (Figure 2 right) shown in the manuscript, the highlighted regions generally correspond to anatomical structures relevant to the associated clinical terms, suggesting that the learned visual representations capture clinically meaningful semantic cues through vision-language alignment. We will revise the manuscript to explicitly describe these visualizations as qualitative examples of semantic cross-modal alignment, rather than conclusive interpretability evidence. We also agree that a dedicated quantitative evaluation of text-region alignment would further strengthen this aspect of the work and consider it an interesting direction for future research.\n\n#### **VQA serves as an additional evaluation of representation transfer**\n\nThe purpose of the VQA experiment is not to develop a specialized medical VQA system, but to evaluate whether the learned image representations transfer effectively to a multimodal downstream task requiring joint visual and clinical reasoning. Given the limited number of available VQA annotations, we formulate this benchmark as a closed-set VQA task. As described in the manuscript, HandXFM combines its visual encoder with the frozen BiomedCLIP text encoder via a lightweight cross-attention module, followed by an MLP classifier that predicts answers from a predefined answer vocabulary. Performance is therefore evaluated using Top-1 and Top-5 accuracy. This design is motivated by our pretraining strategy: HandXFM is distilled toward the frozen BiomedCLIP image encoder, whose visual representations are already aligned with the corresponding BiomedCLIP text encoder. Consequently, the learned HandXFM visual representations remain compatible with the same vision-language embedding space, making the frozen BiomedCLIP text encoder a natural choice for multimodal fusion without requiring a generative language model or additional language adaptation.\n\n#### **Edge-aware masking emphasizes anatomically informative regions during representation learning**\n\nUnlike random masking, edge-aware masking samples masked patches according to the anatomical edge distribution. As a result, masked patches are more likely to contain cortical boundaries, joint spaces, and other clinically informative structures instead of predominantly homogeneous background regions. During masked latent reconstruction, the model is therefore encouraged to recover representations of anatomically meaningful content rather than relying primarily on low-information regions. This provides a stronger supervisory signal for learning fine-grained structural representations, which is reflected by the largest improvements on localization-sensitive downstream tasks, while remaining beneficial for regression and classification tasks.\n\n#### **Revised scope of the contribution.**\n\nUnder the Use-Inspired framing, our claim is that the hand-radiograph setting motivates a specific combination of complementary radiography-domain and biomedical-semantic supervision, visible and masked latent learning, and edge-biased sampling, and that controlled ablations support the value of these choices across clinically relevant global and local tasks. We will not claim that the chest teacher is uniquely structural, that attention maps are faithful explanations, that the VQA task is open-ended, or that every component dominates every individual metric. These revisions align the methodological claims with the evidence and with the intended clinical application.\n\n---\n\nWe sincerely thank the reviewer again for the thoughtful and constructive feedback. The comments have helped us substantially improve the presentation of the method, the interpretation of the experimental evidence, and the clarity of the evaluation protocol. We will incorporate these revisions in the final manuscript."+ },+ "createdAt": "2026-07-31T17:10:04.921Z",+ "modifiedAt": "2026-11-19T16:54:29.644Z",+ "url": "https://openreview.net/forum?id=fKr07Pdg6F¬eId=yGYm6cyRtH",+ "license": "CC-BY-4.0"+}