GlucoFM: A Dual-Stream Foundation Model for Continuous Glucose Monitoring
Import NeurIPS 2026 submission SxWZ7KJ3KP: 8 notes
@openreview[bot] · 2026-11-22 17:56 UTC · 466110187828
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,34 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "SxWZ7KJ3KP"+ }+ ],+ "title": "GlucoFM: A Dual-Stream Foundation Model for Continuous Glucose Monitoring",+ "authors": [+ "Zechen Li",+ "Keerthana Natarajan",+ "Weizhi Zhang",+ "Menglian Zhou",+ "Simon A. Lee",+ "Yuwei Zhang",+ "Maxwell A Xu",+ "Zeinab Esmaeilpour",+ "Flora D. Salim",+ "Mark Malhotra",+ "Lindsey Sunden",+ "Shwetak Patel",+ "Yuzhe Yang",+ "Ahmed Metwally"+ ],+ "abstract": "Continuous glucose monitoring (CGM) provides a dense view of daily metabolic physiology, yet existing generic time-series and CGM-specific foundation models often encode glucose traces as entangled single-stream sequences, leaving their multiscale temporal structure only implicitly modeled. We present GlucoFM, a lightweight CGM foundation model that aligns irregular recordings to a 24-hour chronological grid, preserves observation masks, and decomposes glucose dynamics into slow-varying glycemic trend and short-term deviation streams. GlucoFM is pretrained on 109,066 hours of unlabeled CGM recordings from 477 subjects with masked contextual latent prediction over fused daily representations and temporal dynamics prediction over the two streams. Across four diverse cohorts and seven phenotype-classification tasks, GlucoFM achieves the strongest subject-disjoint linear-probing performance among evaluated baselines, improving average PR-AUC by 4.1 points over the best CGM-specific foundation model, while also supporting strong cross-dataset transfer and few-shot adaptation. Beyond phenotyping, when combined with recent CGM, meal nutrition, and subject context, the same frozen encoder achieves the lowest two-hour postprandial glycemic response errors among evaluated methods for trajectory, incremental area under the curve, peak rise, and peak timing. Together, these results demonstrate that GlucoFM learns reusable frozen CGM representations spanning metabolic phenotyping and context-conditioned glucose-response prediction.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/sxwz7kj3kp/forms.json added
+++ b/reviews/openreview/sxwz7kj3kp/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/1wx06oayva.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/1wx06oayva.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "1wx06OaYVa",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair Pf5y",+ "content": {+ "metareview": "The paper presents GlucoFM, a lightweight foundation model for continuous glucose monitoring. It decomposes daily CGM traces into a slowly varying state stream and a transient event stream and uses complementary self-supervised objectives to pretrain on approximately 109,000 hours of data from 477 individuals. The paper reports generally strong frozen-representation performance across clinical prediction tasks, cross-dataset transfer, and few-shot adaptation, often ranking first or second among CGM-specific and general time-series baselines.\n\nThe work studies an important application using a relatively large CGM pretraining corpus. The evaluation covers multiple cohorts, clinical endpoints, cross-dataset transfer, few-shot learning, and architectural ablations. Reviewers Kkgy and rPuz acknowledge that the reported improvements are generally consistent and that the manuscript is clearly organized. The lightweight design and explicit attempt to model distinct temporal scales are practically appealing.\n\nReviewer Kkgy notes that the state and event streams are produced through smoothing and residualization rather than physiological ground truth. The model may therefore exploit CGM autocorrelation, device filtering, or smoothness rather than distinct metabolic states and events.\nWhile cross-validation variance is provided in the appendix, the paper lacks explicit pairwise statistical significance testing to verify that the modest gains over baseline models are statistically reliable.\nDevice brands, sampling rates, and proprietary manufacturer preprocessing vary widely across the datasets, but a device-stratified analysis is missing.\nReviewer rPuz questions whether independent 24-hour context windows adequately capture cross-day carryover and longer-term glycemic dynamics, and whether the benefits of the proposed decomposition and augmentations are sufficiently distinguished from modifications that could be incorporated into existing models.\nReviewer tPQP points out that common clinical management metrics (such as time in range) are absent from the evaluations, and flags that the human-subject ethics and data governance description requires further detail. \n\nI recognize that some of these issues may not be fully resolvable through new experiments during the rebuttal period; clear methodological justification, additional analyses where feasible, and appropriately narrowed claims will also be considered.\n\n1.\tProvide an appropriate paired uncertainty analysis of the performance differences, such as subject-level paired bootstrap confidence intervals, paired permutation testing on held-out subject predictions, or another method that accounts for dependence across repeated cross-validation splits. This is particularly important because several cohorts are small, some test folds contain fewer than ten participants, and the reported variability in Appendix Table 6 is large relative to several of the claimed improvements.\n2.\tReport device-stratified results or otherwise analyze device effects to assess whether performance is robust across manufacturers and sampling protocols, or may partly reflect device-specific preprocessing signatures.\n3.\tThe existing single-stream ablations provide evidence that the dual-stream architecture improves downstream performance. However, the authors should demonstrate or clarify whether the state and event representations contain complementary, non-redundant information beyond the frequency separation imposed by construction. Relevant evidence could include representational-similarity or dependence analyses or associations with independent physiological or behavioral measurements. Otherwise, the physiological interpretation of the streams should be narrowed.\n4.\tClearly state the relevant IRB or ethics determination, participant consent or secondary-use basis, data-access permissions, and institutional governance procedures, particularly for the non-public Wear-CGM cohort.\n5.\tClarify the consequences of representing each window independently over 24 hours, including boundary sensitivity and the limited ability to encode multi-day carryover within any individual representation. Any shifted-window or longer-context sensitivity evidence would be helpful, but at minimum this limitation should be explicitly reflected in the claims.\n6.\tIn Appendix B.3, the authors explain that they retrained baseline models (CGM-JEPA, X-CGM-JEPA, and GluFormer) on their new 109,066-hour corpus using the baselines' official configurations. Clarify how convergence and model selection were assessed for the same-corpus baselines, including validation criteria, training curves where available, and whether reasonable corpus-specific adjustments were considered. This is needed to determine whether the comparison may be influenced by unequal optimization effort.\n7.\tAccording to Appendix A.2, unlabeled subjects from the Stanford and ShanghaiT2DM datasets were included in the pretraining corpus. Although participant-level separation prevents direct subject leakage, pretraining includes other participants from some downstream sites. The current results therefore do not fully establish transfer to unseen institutions or device pipelines. A leave-one-cohort-out analysis would strengthen this claim.\n8.\tAppendix A.3 outlines binary prediction tasks for systemic, long-term conditions such as hyperlipidemia and obesity; comparisons with standard CGM summaries, such as mean glucose, variability, time in range, and rate-of-change features, would help establish whether the learned representation adds value beyond conventional CGM phenotyping. The potential for cohort, device, and demographic confounding should also be discussed.\n9.\tThe authors claim their architecture \"preserves observation masks\" and explicitly avoids interpolating missing values. The authors should clarify how the causal Gaussian filter behaves near missing intervals, including what happens when a patch has little or no recent observed support, and whether estimates become disproportionately dependent on older measurements.\n10.\tTable 4 is missing cross-dataset transfer results for ShanghaiT2DM, which is a representative dataset for domain shift. Explain why ShanghaiT2DM is excluded from the cross-dataset transfer analysis and whether any clinically harmonized task, such as insulin resistance, could be a meaningful transfer evaluation. \n11.\tBecause the model explicitly encodes absolute time of day, clarify how sensitive performance is to this assumption. An ablation without circular time features, or a controlled phase-shift analysis, would help determine whether the model captures robust circadian structure or cohort-specific daily schedules.\n12.\tThe abstract and introduction heavily motivate the model's ability to capture \"short-term deviations\" that reflect \"acute physiological responses\" or \"behavior\". Furthermore, Figure 1 explicitly asks if the model can \"disentangle latent behavioral dynamics\". There is no multimodal evaluation against actual behavioral ground truth, such as meal logs, insulin administration, or physical activity data. The authors should either provide validation against independent behavioral annotations or consistently narrow the behavioral and physiological language in the abstract, introduction, Figure 1, and discussion."+ },+ "createdAt": "2026-07-18T17:42:53.440Z",+ "modifiedAt": "2026-11-18T15:18:46.701Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=1wx06OaYVa",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/bjuy81zwwm.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/bjuy81zwwm.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "bJuy81zwwM",+ "replyTo": "Kajj3PcZEO",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewer for recognizing the clarity, broad evaluation, and technical soundness of our work. We address each question below.\n\n---\n> 1. Need for GlucoFM relative to existing foundation models\n\n- **Design goal**: \n - We do not claim that previous foundation models are unusable. A central value of a foundation model is that **one pretrained backbone can be reused across tasks with limited task-specific adaptation**. GlucoFM targets reusable representation learning: one lightweight frozen backbone supports multiple tasks with lightweight heads, rather than requiring full task-specific fine-tuning.\n - For a controlled comparison, we re-pretrained CGM-JEPA, X-CGM-JEPA, and GluFormer on exactly the same unlabeled corpus as GlucoFM, removing pretraining-data confounding. CGMformer was evaluated using its released checkpoint, pretrained on a larger external non-public 964-participant cohort. Prior work evaluated different task sets and protocols; **none reports all these 7 phenotype benchmark**. We will release GlucoFM’s weights, code, and evaluation pipeline. \n\n- **Existing evidence**:\n - GlucoFM leads PR-AUC on all diabetes and β-cell dysfunction evaluations and 3/4 insulin-resistance evaluations. Across 14 cohort–task evaluations, its corrected paired gains are +4.11/+4.34/+2.57 points over same-data CGM-JEPA and +4.74/+4.67/+2.34 over CGMformer for PR-AUC/ROC-AUC/Macro-F1.\n - The contribution is also not CGM-aware augmentation alone, which could be transferred to other architectures. Under matched training, the submitted dual-stream encoder achieves 58.81/66.73/59.87, compared with 55.29/63.68/58.29 for the raw-input encoder.\n\n- **New fine-tuning analysis**: To directly test the reviewer’s hypothesis, we fully fine-tuned Chronos-2-small and MOMENT-small using model-native preprocessing, the same windows and labels as Table 3, the exact 10 × 5 subject-disjoint outer folds, and inner validation without outer-test-based selection. Each cohort–task evaluation required training a separate complete backbone.\n\n**Rebuttal Table 4. Frozen GlucoFM versus fine-tuned general FMs (PR-AUC/ROC-AUC/Macro-F1, %)**\n\n| Evaluation | Frozen GlucoFM (0.72M) | Fine-tuned Chronos-2-small (28M) | Fine-tuned MOMENT-small (40M) |\n|---|---:|---:|---:|\n| CGMacros Diabetes | **65.90/78.70/58.30** | 55.46/70.94/49.54 | 56.33/70.80/46.85 |\n| CGMacros IR | **91.90/81.20/69.60** | 87.39/75.06/66.08 | 87.98/75.60/64.71 |\n| Stanford Diabetes | **77.30/72.80/66.20** | 75.71/72.65/65.02 | 75.46/72.09/64.58 |\n| Stanford IR | **67.60/69.10/64.00** | 65.09/67.72/58.79 | 65.78/67.44/59.11 |\n| Hall Diabetes | **66.20/75.90/64.50** | 56.36/64.78/56.78 | 55.35/67.00/55.57 |\n| Hall IR | **60.20/70.70/62.00** | 49.68/61.22/51.66 | 55.92/64.51/54.23 |\n| ShanghaiT2DM IR | **67.00/57.80/55.40** | 60.58/49.16/44.66 | 60.52/50.28/44.70 |\n\n- **Findings**: Frozen GlucoFM is higher on all 3 metrics in all 7 evaluations. Using a shared-fold GlucoFM rerun that reproduced the submitted results within 0.1 percentage point, the task-averaged Nadeau–Bengio-corrected differences were:\n - versus Chronos: +6.54 [3.41, 9.67] / +6.38 [3.37, 9.39] / +6.76 [2.35, 11.18];\n - versus MOMENT: +5.53 [2.00, 9.05] / +5.49 [1.84, 9.15] / +7.16 [2.49, 11.83], for PR-AUC/ROC-AUC/Macro-F1. All six Holm-adjusted $p\\leq0.0111$. These tests support task-averaged gains, not significance for every individual task.\n\n- **Conclusion**: General-purpose FMs clearly benefit from CGM-specific fine-tuning, but they do not match GlucoFM’s frozen representations in this evaluation. GlucoFM therefore provides a stronger **accuracy–reuse–model-size trade-off**: one lightweight frozen backbone supports multiple downstream tasks while outperforming substantially larger models that are fully fine-tuned separately for each task.\n\n---\n> 2. Advantage and limitation of independent 24-hour modeling\n\nThe two choices serve different roles: **24 hours defines the modeling scope, whereas state–event decomposition is an empirically evaluated architectural contribution.**\n\n- **24-hour context.** GlucoFM targets within-day metabolic phenotyping rather than native multi-day trajectory modeling. 24 hours is the context length, not midnight-to-midnight segmentation. Overlapping windows with **diverse start times** and circular time features capture pre-dawn and cross-midnight patterns, but a single window cannot encode cross-day carryover.\n\nNevertheless, any finite window can split dynamics, and a single embedding cannot directly encode cross-day carryover.\n\n- **New multi-day analysis**: We froze GlucoFM, independently encoded contiguous 24-hour windows, and aggregated adjacent $K$-day embeddings. Within each cohort, all $K$ values use the same $K_{\\max}$-eligible subjects and identical subject-level splits. A lightweight probe is fitted for each $K$, while the backbone remains frozen. Because this eligibility restriction and subject-level aggregation differ from Table 3, $K=1$ is not intended to reproduce its window-level results. The maximum $K$ is cohort-specific; Hall is capped at $K=4$ because requiring five valid days would reduce the eligible cohort from 37 to 27 subjects.\n\n**Rebuttal Table 5. Multi-day core tasks (PR-AUC, %)**\n\n| Dataset | Task | Pooling | K=1 | K=2 | K=3 | K=4 | K=5 | K=6 | K=7 |\n|---|---|---|---:|---:|---:|---:|---:|---:|---:|\n| CGMacros | Diabetes | Mean | 64.0 | 65.6 | 66.3 | 67.0 | **67.6** | 67.4 | 67.0 |\n| CGMacros | IR | Mean | 92.7 | 93.2 | 93.6 | 93.8 | 94.2 | 94.4 | **94.6** |\n| Stanford | Diabetes | Mean | 67.6 | 69.8 | 70.6 | 70.3 | 70.5 | 71.8 | **73.6** |\n| Stanford | β-cell dysfunction | Mean | 60.3 | 61.8 | 64.0 | 65.4 | 66.8 | 68.3 | **69.9** |\n| Stanford | IR | Mean | 60.3 | 61.5 | 62.4 | 62.9 | 64.1 | 65.9 | **66.6** |\n| Hall | Diabetes | Mean | 59.8 | 62.8 | 67.7 | **73.8** | — | — | — |\n| Hall | Glucotype | Mean | 85.9 | 91.6 | 96.0 | **99.5** | — | — | — |\n| Hall | IR | Mean | 46.3 | 44.5 | 46.3 | **49.8** | — | — | — |\n| Shanghai | IR | Mean | **61.9** | **61.9** | 61.0 | 61.7 | 61.2 | 61.4 | **61.9** |\n| Shanghai | IR | Concat(mean,max) | 63.1 | 62.5 | 60.8 | 62.1 | 67.8 | **75.2** | **75.2** |\n\n- **Findings**: The same frozen daily backbone supports different observation lengths without retraining the backbone. Mean aggregation improves all Stanford tasks, CGMacros IR, and Hall diabetes/glucotype, while gains vary across other settings. Shanghai further shows that aggregation is task-dependent: mean pooling remains flat, whereas concat(mean,max) improves performance at $K=6–7$. We therefore claim that daily representations are **composable for multiday phenotyping**, not that longer observation or one aggregation rule is universally superior.\n\n- **State–event decomposition.** Holding the corpus, augmentation, objectives, optimization, and downstream protocol fixed, dual-stream encoding achieves 58.81/66.73/59.87, versus 55.29/63.68/58.29 for raw-input, 55.61/63.74/57.94 for state-only, and 51.76/60.09/55.57 for event-only encoding. This supports state–event fusion as a useful multi-scale inductive bias without treating either stream as physiological ground truth.\n\n---\n> 3. Meaning of “irregular” CGM recordings\n\n“Irregular” refers to heterogeneous and incomplete observations, not randomly varying nominal sensor cadence. The datasets contain different sensors and 5- or 15-minute rates; timestamps may also be offset from the common 5-minute grid. We use timestamp-based binning and retain only observed measurements. Approximately every third position is observed for 15-minute recordings, while dropout, non-wear, and other missing positions remain masked without interpolation. Gaps of up to 1 hour are preserved as missing observations; longer gaps split the trace into separate continuous segments to avoid constructing windows across extended disconnections or sensor replacements.\n\n---\n> 4. Why cross-validation was used\n\nCross-validation is used only for **within-dataset linear probing and few-shot evaluation**, which are supervised probe experiments rather than zero-shot classification. The encoder is frozen; a classifier is trained on four subject-disjoint folds and evaluated on unseen subjects in the fifth. **Repeated folds reduce sensitivity to a single split**, and all methods use identical folds with train-only preprocessing and model selection.\n\nFor **cross-dataset transfer**, no cross-validation or target-label exposure is used: the probe is trained on the full source cohort and directly evaluated on the target cohort.\n\n---\n> 5. Selection of the number of temporal patches \n\n$P=24$ follows from dividing a 24-hour window into 24 non-overlapping one-hour patches, each containing 12 positions on the 5-minute grid. This scale was chosen a priori to balance local resolution, observations per patch, sequence length, and model size; it was not selected using downstream labels, and we do not claim physiological optimality.\n\n---\n> 6. Modalities and heterogeneous sampling rates\n\nGlucoFM is self-supervised using only unlabeled CGM signals, including Wear-CGM. Other modalities are not consistently paired across cohorts and are excluded; clinical metadata only constructs downstream labels and never enters the encoder.\n\nAll readings are timestamp-aligned to a 288-position 5-minute grid. Unobserved positions remain masked rather than interpolated. Pretraining includes real 5- and 15-minute recordings and structural sparsification that exposes dense recordings to 15-minute-like observation patterns.\n\n---\nFurther, GlucoFM **remained informative across matched simultaneous Dexcom/Libre recordings**, with no consistent aggregate sensor advantage (Kkgy, Rebuttal Table 2), while additional **postprandial glucose-response forecasting** and **biomarker regression** support its utility beyond classification (tPQP, Rebuttal Tables 8-9).\n\nWe hope these additional analyses address the reviewer’s concerns and would appreciate reconsideration of the score."+ },+ "createdAt": "2026-07-26T20:33:58.022Z",+ "modifiedAt": "2026-11-18T17:11:20.466Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=bJuy81zwwM",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/djhvlee9nb.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/djhvlee9nb.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "DJhVLEE9nb",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper presents GlucoFM, a lightweight foundation model for continuous glucose monitoring. It decomposes daily CGM traces into a slowly varying state stream and a transient event stream and uses complementary self-supervised objectives to pretrain on approximately 109,000 hours of data from 477 individuals. The paper reports generally strong frozen-representation performance across clinical prediction tasks, cross-dataset transfer, and few-shot adaptation, often ranking first or second among CGM-specific and general time-series baselines.\n\nThe work studies an important application using a relatively large CGM pretraining corpus. The evaluation covers multiple cohorts, clinical endpoints, cross-dataset transfer, few-shot learning, and architectural ablations. Reviewers Kkgy and rPuz acknowledge that the reported improvements are generally consistent and that the manuscript is clearly organized. The lightweight design and explicit attempt to model distinct temporal scales are practically appealing.\n\nReviewer Kkgy notes that the state and event streams are produced through smoothing and residualization rather than physiological ground truth. The model may therefore exploit CGM autocorrelation, device filtering, or smoothness rather than distinct metabolic states and events.\nWhile cross-validation variance is provided in the appendix, the paper lacks explicit pairwise statistical significance testing to verify that the modest gains over baseline models are statistically reliable.\nDevice brands, sampling rates, and proprietary manufacturer preprocessing vary widely across the datasets, but a device-stratified analysis is missing.\nReviewer rPuz questions whether independent 24-hour context windows adequately capture cross-day carryover and longer-term glycemic dynamics, and whether the benefits of the proposed decomposition and augmentations are sufficiently distinguished from modifications that could be incorporated into existing models.\nReviewer tPQP points out that common clinical management metrics (such as time in range) are absent from the evaluations, and flags that the human-subject ethics and data governance description requires further detail. \n\nI recognize that some of these issues may not be fully resolvable through new experiments during the rebuttal period; clear methodological justification, additional analyses where feasible, and appropriately narrowed claims will also be considered.\n\n1.\tProvide an appropriate paired uncertainty analysis of the performance differences, such as subject-level paired bootstrap confidence intervals, paired permutation testing on held-out subject predictions, or another method that accounts for dependence across repeated cross-validation splits. This is particularly important because several cohorts are small, some test folds contain fewer than ten participants, and the reported variability in Appendix Table 6 is large relative to several of the claimed improvements.\n2.\tReport device-stratified results or otherwise analyze device effects to assess whether performance is robust across manufacturers and sampling protocols, or may partly reflect device-specific preprocessing signatures.\n3.\tThe existing single-stream ablations provide evidence that the dual-stream architecture improves downstream performance. However, the authors should demonstrate or clarify whether the state and event representations contain complementary, non-redundant information beyond the frequency separation imposed by construction. Relevant evidence could include representational-similarity or dependence analyses or associations with independent physiological or behavioral measurements. Otherwise, the physiological interpretation of the streams should be narrowed.\n4.\tClearly state the relevant IRB or ethics determination, participant consent or secondary-use basis, data-access permissions, and institutional governance procedures, particularly for the non-public Wear-CGM cohort.\n5.\tClarify the consequences of representing each window independently over 24 hours, including boundary sensitivity and the limited ability to encode multi-day carryover within any individual representation. Any shifted-window or longer-context sensitivity evidence would be helpful, but at minimum this limitation should be explicitly reflected in the claims.\n6.\tIn Appendix B.3, the authors explain that they retrained baseline models (CGM-JEPA, X-CGM-JEPA, and GluFormer) on their new 109,066-hour corpus using the baselines' official configurations. Clarify how convergence and model selection were assessed for the same-corpus baselines, including validation criteria, training curves where available, and whether reasonable corpus-specific adjustments were considered. This is needed to determine whether the comparison may be influenced by unequal optimization effort.\n7.\tAccording to Appendix A.2, unlabeled subjects from the Stanford and ShanghaiT2DM datasets were included in the pretraining corpus. Although participant-level separation prevents direct subject leakage, pretraining includes other participants from some downstream sites. The current results therefore do not fully establish transfer to unseen institutions or device pipelines. A leave-one-cohort-out analysis would strengthen this claim.\n8.\tAppendix A.3 outlines binary prediction tasks for systemic, long-term conditions such as hyperlipidemia and obesity; comparisons with standard CGM summaries, such as mean glucose, variability, time in range, and rate-of-change features, would help establish whether the learned representation adds value beyond conventional CGM phenotyping. The potential for cohort, device, and demographic confounding should also be discussed.\n9.\tThe authors claim their architecture \"preserves observation masks\" and explicitly avoids interpolating missing values. The authors should clarify how the causal Gaussian filter behaves near missing intervals, including what happens when a patch has little or no recent observed support, and whether estimates become disproportionately dependent on older measurements.\n10.\tTable 4 is missing cross-dataset transfer results for ShanghaiT2DM, which is a representative dataset for domain shift. Explain why ShanghaiT2DM is excluded from the cross-dataset transfer analysis and whether any clinically harmonized task, such as insulin resistance, could be a meaningful transfer evaluation. \n11.\tBecause the model explicitly encodes absolute time of day, clarify how sensitive performance is to this assumption. An ablation without circular time features, or a controlled phase-shift analysis, would help determine whether the model captures robust circadian structure or cohort-specific daily schedules.\n12.\tThe abstract and introduction heavily motivate the model's ability to capture \"short-term deviations\" that reflect \"acute physiological responses\" or \"behavior\". Furthermore, Figure 1 explicitly asks if the model can \"disentangle latent behavioral dynamics\". There is no multimodal evaluation against actual behavioral ground truth, such as meal logs, insulin administration, or physical activity data. The authors should either provide validation against independent behavioral annotations or consistently narrow the behavioral and physiological language in the abstract, introduction, Figure 1, and discussion.",+ "final_justification": "This paper introduces GlucoFM, a lightweight foundation model for continuous glucose monitoring that decomposes daily traces into slow-varying glycemic trends and short-term deviations. Although initial reviews raised valid concerns regarding the physiological interpretations of the model's architecture, temporal limitations, and the statistical reliability of the results, the authors provided an exceptionally thorough and compelling rebuttal that successfully resolved these issues."+ },+ "createdAt": "2026-09-24T11:16:48.563Z",+ "modifiedAt": "2026-11-18T14:52:40.087Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=DJhVLEE9nb",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/kajj3pczeo.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/kajj3pczeo.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "Kajj3PcZEO",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer rPuz",+ "content": {+ "summary": "This paper presents GlucoFM, a foundation model for continuous glucose monitoring data for 24 hour time blocks. They introduce a method using dual stream modeling of glucose states and events, cgm augmentation, masked latent prediction and modeling of temporal dynamics to help learn underlying glucose dynamics. They test and compare the model with prior methods using multiple CGM datasets for different tasks including linear probing, few shot performance and cross-dataset transfer.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Clarity:** This paper’s presentation is very strong, with easy to understand graphics, paragraph structure and flow.\n\n**Significance and Originality:** My main concerns lie around significance and originality. I am looking for a stronger justification about where this model's contribution lies in comparison to previous methods. While GlucoFM in most cases does perform better than previous models, it is still unclear to me why this new method was needed. Why do previous CGM specific foundation models not suffice? Moreover, why are previous general purpose foundation models (like Chronos, Moment) not sufficient? Could they not be fine tuned on CGM data and also do equally well? See Question 1a.\n\nFurthermore, as motivated in the paper it is unclear why daily windowing and state-event decoupling are strong separators from prior work; these feel more like different assumptions as opposed to inherent advantages or problems with the previous methods. (I note that CGM-aware augmentation does seem like an advantage but this could also be added to prior methods in a straightforward manner). In particular, daily windowing using rigid end of day cutoffs like this has some notable disadvantages (for example failing to capture pre-dawn phenomena and inability to account for carryover effects from prior days.) See Question 1b.\n\nLastly, the paper claims to align irregular CGM recordings. However, all CGM sensors record glucose at a regular cadence (e.g., every t minutes such as every 5 mins) and are therefore not irregular. Can the authors specify in what way the data is irregular and how this is a contribution? See Question 1c.\n\n**Quality:** The submission appears mostly technically sound, minus a few clarifying questions (see Questions 2-4). Of most importance, why was cross fold validation used? If the intention was to test zero-shot performance and cross-dataset transfer, this is somewhat confounded by the use of cross validation, which introduces exposure to the data distribution.",+ "quality": 3,+ "clarity": 4,+ "significance": 3,+ "originality": 3,+ "questions": "1a. Why do previous CGM specific foundation models not suffice? Why are previous general purpose foundation models (like Chronos, Moment) not sufficient particularly if they were fine tuned for CGM?\n\n1b. Why are daily windowing and state-event decoupling inherent advantages over prior methods? How do you address shortcomings of daily windowing?\n\n1c. In what way is the data irregular since CGMs record glucose at a regular cadence? I may be misunderstanding something here, but can the authors please clarify how handling the irregularity is a contribution?\n\n2. Why was cross-validation used?\n\n3. How is *P* the number of temporal patches selected? Is this guided by some underlying physiology or temporal consideration?\n\n4. Is only CGM data used from the datasets that contain other features too (eg like multimodal features in WearCGM data)? How are different sampling rates handled? Section 3.1 mentions that data are aligned to a fixed 24 hour grid with 5 minute timestamps but some datasets have 15 minute timestamps. Are the dataset sampling rates being used interchangeably (e.g., the models were pretrained on data at 5 minute sampling rate and then trained and tested on ones of a different sampling rate?)",+ "limitations": "Yes",+ "rating": 5,+ "confidence": 5,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No concerns",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I have changed my score to accept. The authors adequately addressed my main concerns surrounding novelty and originality of this foundation model, use of 24 hour modeling windows, definition of irregularity, use of cross validation and handling of different sampling rates. With these additional analyses included (eg in the appendix) I believe this is a strong paper with high originality and impact, valid technical soundness and good presentation."+ },+ "createdAt": "2026-06-25T21:33:19.331Z",+ "modifiedAt": "2026-11-18T13:35:37.183Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=Kajj3PcZEO",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/nupy962dy3.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/nupy962dy3.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "NUPY962DY3",+ "replyTo": "Utpzp2vRib",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We appreciate that the reviewer considers the work technically solid and the comparisons broad. We address each concern below and will revise accordingly.\n\n---\n> 1. State–event interpretation and non-redundancy\n\nWe agree that smoothing and residualization do not provide physiological ground truth. Our submission defines the two inputs as a causal, mask-aware low-frequency trend and its high-frequency residual. We will therefore replace *baseline/transient physiology* with *slow-varying glycemic trend* and *short-term deviation*. This self-supervised multi-scale bias requires no meal, activity, or sleep annotations, which were not consistently available across our >100,000h corpus.\n\n- **Evidence already in the submission.** The Fig. 7 ablation compares raw, state-only, event-only, and dual-stream encoders under identical training and evaluation settings. The dual-stream model is best on all three task-averaged metrics, demonstrating the downstream utility of explicit decomposition and fusion. This ablation does not, by itself, establish physiological semantics or pre-fusion non-redundancy.\n\n- **New validation protocol.** CGMacros is our only downstream cohort with time-aligned meal logs. We analyze its 5-min Dexcom data and extract frozen 64-d pre-fusion $z_{state}$ and $z_{event}$ tokens from the same checkpoint without encoder updates. All representations use identical linear probes—Ridge for continuous targets and logistic regression for binary targets—with 5 repeated subject-disjoint 5-fold splits. We report repeat-wise OOF means and paired 95% CIs from 2,000 subject-cluster bootstraps. Meal labels are used only for evaluation, never for pretraining.\n\n We conduct 2 complementary tests:\n\n1. **Stream-content selectivity:** From 7,435 hourly patches across 35 subjects, we predict mask-aware hourly mean glucose and mean absolute adjacent 5-minute change, representing slow level and local dynamic content, respectively.\n2. **External meal alignment:** Using 542 standardized meals, we classify pre-meal (-60 min) versus post-meal (+60 min) tokens, with circular clock time as a control. A harder full-day test localizes tokens 30–120 minutes after exact meal logs among 7,162 eligible tokens from 310 windows, without meal-time, clock, or patch-position features.\n\n**Rebuttal Table 1. Frozen pre-fusion stream analyses**\n\n| Analysis (metric) | State | Event | State $\\oplus$ Event | Clock time | Paired difference (95% CI) |\n|---|---:|---:|---:|---:|---|\n| Glucose level ($R^2$) | 0.962 | 0.401 | — | — | State−Event: 0.561 [0.518, 0.630] |\n| 5-min absolute change ($R^2$) | 0.832 | 0.888 | — | — | Event−State: 0.056 [0.040, 0.073] |\n| Meal phase (ROC-AUC) | 0.849 | 0.847 | 0.854 | 0.704 | State−Time: 0.145 [0.108, 0.178]; Event−Time: 0.142 [0.103, 0.177]; Event−State: −0.002 [−0.015, 0.010] |\n| Post-meal localization (Recall@$K$) | 0.521 | 0.547 | 0.539 | 0.283 | Event−State: 0.026 [0.010, 0.042] |\n\n*Point estimates are means across 5 complete OOF repeats. Recall@K is the fraction of true post-meal tokens recovered in the top $K$ positions, where $K$ is the number of positives in that window.*\n\n- **New findings:**\n - **Content selectivity:** State tokens better preserve glucose level, whereas event tokens better preserve short-term change; both directional paired gaps exclude zero. This provides evidence against pre-fusion collapse and supports functional slow/fast non-redundancy.\n - **External behavioral alignment:** Meal annotations, unseen during pretraining, provide independent validation: both streams outperform clock time in meal-phase prediction, with paired CIs excluding zero. In the harder full-day task, event tokens achieve higher Recall@K with a non-zero paired CI; other event–state localization intervals include zero, so we do not claim event-exclusive meal semantics.\n\n- **Conclusion**: Together, the submitted ablation and new analyses show downstream utility, pre-fusion slow/fast content specialization, and meal-associated information beyond clock time. This supports the state–event design as an effective, non-redundant self-supervised multi-scale inductive bias. We will revise the terminology to reflect functional specialization without implying causal physiological disentanglement.\n\n---\n> 2. Manufacturer preprocessing and device-specific signatures\n\nWe agree that exported CGM values may retain manufacturer-specific filtering, calibration, lag correction, and artifact processing. **Our intended claim is robustness across sensor domains**—not recovery of device-independent physiological ground truth.\n\n- **Existing design**: Our 109,066-h pretraining corpus comprises 79.87% Dexcom, 11.38% Libre, and 8.75% iPro. GlucoFM aligns recordings to a common time grid while preserving observation masks. Mask-aware decoupling uses only observed values, and structural sparsification exposes the model to sparse sampling and gaps. These choices reduce sensitivity to cadence and missingness but cannot eliminate shifts from proprietary manufacturer preprocessing.\n\n- **Existing Libre-domain evidence**: We retrained CGM-JEPA, X-CGM-JEPA, and GluFormer on the same data using official preprocessing and identical subject splits; GlucoFM preserves observation masks rather than interpolating values as observed measurements. On the Libre/15-min Shanghai cohort, GlucoFM ranks first among these controlled same-pretraining CGM baselines on all 3 hypoglycemia metrics. For insulin resistance, it ranks second in PR-AUC and Macro-F1, and third in ROC-AUC. This provides existing cross-domain evidence, although Shanghai simultaneously differs in manufacturer, cadence, site, and cohort composition.\n\n- **New paired device analysis**: We analyzed 393 same-subject, same-date 24-h windows from 44 CGMacros participants wearing Dexcom and Libre simultaneously. We compared native Dexcom with timestamp-matched Dexcom and Libre views; the matched views share subjects, dates, labels, timestamps, and missingness masks. Separate linear probes were evaluated on all 4 CGMacros tasks using the same 10 repeated subject-disjoint 5-fold splits as in Table 3, with held-out window metrics and paired 95% CIs from 2,000 subject-cluster bootstraps.\n\n**Rebuttal Table 2. CGMacros paired-device analysis**\n| Four-task average | PR-AUC | ROC-AUC | Macro-F1 |\n|---|---:|---:|---:|\n| Dexcom native | 62.99 ± 0.98 | 71.56 ± 1.23 | 63.01 ± 0.97 |\n| Dexcom matched mask | 61.34 ± 0.97 | 68.84 ± 1.26 | 60.79 ± 0.96 |\n| Libre matched mask | 65.04 ± 2.07 | 70.73 ± 1.92 | 61.79 ± 1.32 |\n| **Paired difference in percentage points [95% CI]** | | | |\n| Native Dexcom − matched Dexcom | +1.66 [+0.06, +3.38] | +2.72 [+0.69, +4.89] | +2.22 [+0.29, +4.36] |\n| Matched Dexcom − matched Libre | −3.71 [−7.94, +0.95] | −1.89 [−6.35, +2.97] | −1.00 [−5.30, +3.59] |\n\n*Values are mean ± SD over 10 complete OOF repeats.*\n\n- **Findings**: Retaining denser native Dexcom observations yields a modest aggregate gain, showing that sampling density remains relevant despite our robustness design. After exactly matching timestamps and missingness, however, all three four-task-average Dexcom–Libre intervals include zero, providing no evidence of a consistent aggregate sensor advantage. This does not establish equivalence or device-invariant representations, but shows that phenotype-relevant information remains linearly decodable from both simultaneous sensor views after controlling for subject, date, labels, timestamps, and missingness.\n\n- **Revision**: We will revise the Shanghai discussion to describe a compound shift in manufacturer, cadence, site, and cohort composition rather than attributing its results specifically to Libre/15-min sampling. Together, the submitted Shanghai results and new paired analysis provide complementary evidence that GlucoFM remains informative across Dexcom and Libre conditions while appropriately limiting claims about physiological or device invariance.\n\n---\n> 3. Paired statistical significance\n\nWe agree that mean ± std alone does not establish the reliability of the improvements. We therefore performed paired inference on the submitted Table 3 results.\n\n- **Protocol:** All models use identical 10 repeated subject-disjoint 5-fold splits. For each repeat/fold, we macro-average the 14 tasks and compare GlucoFM with CGM-JEPA—the strongest same-pretraining CGM baseline—and CGMformer, pretrained on a larger external cohort. We use two-sided Nadeau–Bengio corrected paired t-tests to account for correlated folds, with Holm correction across six comparisons.\n\n**Rebuttal Table 3. Paired task-averaged comparisons**\n\n| Comparator | Metric | Ours / baseline | Difference [95% CI] | Holm-p |\n|---|---|---:|---:|---:|\n| CGM-JEPA | PR-AUC | 58.8 / 54.7 | +4.11 [2.40, 5.81] | <0.001 |\n| | ROC-AUC | 66.7 / 62.4 | +4.34 [2.26, 6.41] | <0.001 |\n| | Macro-F1 | 59.9 / 57.3 | +2.57 [0.91, 4.23] | 0.006 |\n| CGMformer | PR-AUC | 58.8 / 54.1 | +4.74 [2.47, 7.02] | <0.001 |\n| | ROC-AUC | 66.7 / 62.1 | +4.67 [2.02, 7.32] | 0.003 |\n| | Macro-F1 | 59.9 / 57.5 | +2.34 [0.55, 4.14] | 0.012 |\n\n*Differences are computed from unrounded paired fold-level scores and reported in percentage points.*\n\n- **Findings:** All six corrected 95% CIs exclude zero and all Holm-adjusted p-values remain significant, supporting the reliability of GlucoFM’s task-averaged improvements against both the strongest same-pretraining-data CGM baseline and a model pretrained on a larger external cohort.\n\n- **Revision:** We will add the paired-test protocol and complete task-level confidence intervals to the appendix.\n\n---\nBeyond these analyses, additional results on **multiday phenotyping** (rPuz, Rebuttal Table 5), **postprandial glucose-response forecasting**, and **biomarker regression** (tPQP, Rebuttal Tables 8-9) further extend the evaluation beyond single-day classification. We will also enlarge and simplify Figure 1.\n\nWe hope these clarifications address your concerns and invite you to reconsider your score."+ },+ "createdAt": "2026-07-25T03:31:20.758Z",+ "modifiedAt": "2026-11-18T17:11:21.113Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=NUPY962DY3",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/p9bhrry5gg.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/p9bhrry5gg.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "P9BHrRy5Gg",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer tPQP",+ "content": {+ "summary": "Motivated by the multi-scale dynamics of continuous glucose monitoring (CGM) in diabetes, the paper under the \"General: Most submissions will fall into this type.\" submission category proposes and evaluates GlucoFM, a lightweight self-supervised foundation model for CGM representation learning.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The paper works on a timely application of machine/deep learning in diabetes that holds potential for a large global impact due to the prevalence of diabetes and current gaps in CGM sensor technologies. However, its evaluation methodology is insufficient to harvest this potential, because relevant metrics such as those reflecting time in range and hypoglycemia prevention mentioned on p. 1 of the paper have not been included in the evaluation. The author's response clarifies this standing now, making a convincing case for their study where these clinical metrics are not directly applicable but other comparative evaluations to give evidence of the clinically meaningful methodological gains are and have been achieved. Also, the current IRB statement and other ethical considerations are now sufficiently addressed. Finally, a clear and convincing explanation of the novel methodological contributions of this paper beyond integrating and slightly adapting the existing deep learning methods such as Transformers has been made; authors are encourage to revise their paper based on their own addressing of the reviewer comments, possibly sharpened by them reflecting on what the reviewers were highlighting as the strengths of their study.",+ "quality": 3,+ "clarity": 3,+ "significance": 4,+ "originality": 3,+ "questions": "Addressed: What are the key research contributions of the paper to deep learning methods, their specific applications to CGM data modelling, and applications to other time series signals?\n\nAddressed: How does the model perform with respect to clinical metrics?\n\nAddressed: How did you address ethical considerations related to the use of data from human subjects for the purposes of this study?",+ "limitations": "The authors have briefly addressed the limitations of their work and proposed some future work, but otherwise their discussion part of this paper is somewhat lacking. How are you guiding future work to extend the framework as a deep learning contribution, apply it more generally to other data signals, and translate it into clinical practice in diabetes monitoring/management? What actionable advice would you give to methodological researchers, applied scientists, CGM-device developers, and clinicians interested in extending, applying, and translating this study?",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "See above"+ },+ "createdAt": "2026-06-25T09:20:35.093Z",+ "modifiedAt": "2026-11-18T13:35:38.690Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=P9BHrRy5Gg",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/utpzp2vrib.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/utpzp2vrib.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "Utpzp2vRib",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Kkgy",+ "content": {+ "summary": "The authors present a CGM foundation model, GlucoFM, which is pretrained on more than 100 thousand hours of records from nearly 500 subjects. This CGM foundation model is lightweight, combining state-event modeling and CGM-aware augmentation. It evaluates frozen representations on several CGM cohorts and clinical prediction tasks, reporting gains over CGM-specific and general time-series baselines, plus few-shot, cross-dataset, and ablation results.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The authors compared their proposed GlucoFM with general forecasting models and other SOTA CGM-related foundation model, proving that their GlucoFM achieve overall better results.\nThe state and event streams are defined by smoothing and residualization, not by supervised physiological ground truth. So claims like baseline physiology and transient dynamics are plausible but not validated.\nThe objective may mainly exploit CGM autocorrelation or smoothness rather than learning clinically meaningful dynamics.\n\nThe reported improvements appear numerically consistent but relatively modest compared with the variability. Although GlucoFM often ranks first or second, the paper does not report paired statistical tests or confidence intervals demonstrating that these gains are statistically reliable across splits or subjects.\n\nThe font size of Figure 1 is way too small and hard to read. An overview of the research is always helpful. Please edit Figure 1 to improve readability.",+ "quality": 3,+ "clarity": 3,+ "significance": 2,+ "originality": 3,+ "questions": "Manufacturer preprocessing may confound the proposed state–event decomposition.\nThe model operates on exported CGM glucose values, which are already processed by device-specific algorithms. This makes the interpretation of the “event stream” as transient physiology or behavior less direct, since residuals may also reflect device-side filtering, lag correction, or artifact processing.\nThe datasets mix Dexcom, FreeStyle Libre, and iPro recordings. These differences may introduce device-specific signatures into the learned representations. Thus, some downstream performance differences may reflect device/domain shift rather than purely metabolic phenotype representation. The paper partially acknowledges sampling/device shift, but more analysis would help. The weaker results on ShanghaiT2DM are attributed to Libre/15-minute sampling shift, but the paper does not fully disentangle whether the issue comes from. A device-stratified analysis would strengthen the methodological claim. This would help determine whether GlucoFM learns device-invariant metabolic representations or partly exploits device-specific preprocessing patterns.\n\nThere is no explicit guarantee against the two streams becoming redundant after fusion. The authors should check whether state/event streams have distinct frequency content or non-redundant embeddings.\n\nThe main performance claim would be stronger if the authors reported paired significance tests using the shared cross-validation splits. Since the downstream cohorts are small and several tasks have high variance, it is difficult to determine whether the observed gains reflect a robust improvement or split-level variability.",+ "limitations": "yes",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal and subsequent discussion addressed most of my main concerns.\n\n1. The authors clarified that the state–event design should be interpreted as a multi-scale inductive bias. They also committed to revising the terminology to describe the streams as capturing slow-varying glycemic trends and short-term deviations.\n2. The added pre-fusion analyses, considered with the reported encoder and objective ablations, provide reasonable evidence against complete pre-fusion redundancy and indicate scale-specific differences in the information retained by the two streams. The ablation results also support the downstream utility of both the dual-stream organization and the temporal dynamics objective.\n3. The Nadeau–Bengio-corrected paired tests, confidence intervals, and Holm-adjusted p-values strengthen the evidence supporting the statistical reliability of the task-averaged improvements over CGM-JEPA and CGMformer.\n4. The paired Dexcom–Libre analyses do not establish device invariance or equivalence, and device-specific or outcome-specific effects cannot be fully excluded. However, the additional controlled analyses partially address this concern, and the authors appropriately acknowledge the limitations and narrow the corresponding claims.\n5. The remaining limitations are that the current analyses do not establish physiological semantics and that residual device-specific effects may remain. Given the narrower framing, I regard these as remaining limitations rather than decisive objections, because the supported methodological claim is limited to scale-specific functional specialization and downstream utility."+ },+ "createdAt": "2026-06-26T11:05:17.998Z",+ "modifiedAt": "2026-11-18T13:35:34.985Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=Utpzp2vRib",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/notes/vbajdxbpgd.json added
+++ b/reviews/openreview/sxwz7kj3kp/notes/vbajdxbpgd.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "vbAJdxbpgd",+ "replyTo": "P9BHrRy5Gg",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewer for recognizing the timeliness of our work, and its potential global impact in diabetes. We address each question below.\n\n---\n> 1. Key methodological contribution and broader relevance\n\n- **Deep-learning methodology**: GlucoFM is not a generic application of Transformer/JEPA. GlucoFM couples a mask-aware dual-stream encoder for slow trends and transient residuals with two complementary objectives matched to this architecture: masked prediction after fusion and cross-conditioned next-patch prediction before fusion. Dual-stream modelling improves task-averaged PR-AUC/ROC-AUC/Macro-F1 from 55.29/63.68/58.29 to 58.81/66.73/59.87; removing temporal prediction or CGM-aware augmentation also degrades performance.\n\n- **CGM utility**: The frozen lightweight encoder is evaluated across 4 cohorts, 7 phenotypes, and 14 cohort–task settings, including cross-dataset transfer, multiday aggregation, and few-shot learning. New biomarker-regression and postprandial glucose-response experiments further evaluate continuous metabolic phenotyping and dynamic prediction. Its compact design may support future on-device analysis, *reducing transmission of privacy-sensitive raw CGM data*.\n\n- **Relevance to other signals**: GlucoFM is intentionally designed as a CGM-specific, use-inspired model. We do not claim general-purpose applicability, and cross-signal evaluation is outside the scope of this work.\n\n---\n> 2. Clinical metrics and management relevance\n\nTime in range (TIR) is clinically important for glycemic management, but it is not a label-based metric for our retrospective diabetes-classification tasks. We therefore add a matched-window GMI baseline. Treatment-induced TIR improvement and hypoglycemia prevention require prospective evaluation; we will narrow the p.1 wording and identify them as future endpoints.\n\n- **New GMI-equivalent analysis.** Using the same $K=7$-eligible subjects, fixed 7-day windows, and subject splits as Rebuttal Table 5 in our response to rPuz, we compute $\\mathrm{GMI}_{\\mathrm{eq}}=3.31+0.02392 \\times \\overline{G}$, where $\\overline{G}$ is mean glucose in mg/dL. We apply thresholds of 5.7 for Stanford (binary) and 5.7/6.4 for CGMacros (three-class). We use *GMI-equivalent* because this value is retrospectively computed from the matched 7-day research window rather than a standard-duration clinical GMI report.\n\n**Rebuttal Table 6. GMI-equivalent comparison (Macro-F1, %)**\n| Dataset / setting | GMI-equivalent | GlucoFM | Improvement |\n|:--|--:|--:|--:|\n| Stanford | 59.6 | **67.0** | **+7.4** |\n| CGMacros–Dexcom | 36.3 | **53.7** | **+17.4** |\n| CGMacros–Libre | 63.7 | **65.6** | **+1.9** |\n| CGMacros–Fused | 56.9 | **65.9** | **+9.0** |\n\n*Both methods use identical subjects and windows. GlucoFM reports 10 repeated subject-level CV runs, whereas GMI-equivalent is deterministic. For Fused, same-day Dexcom/Libre embeddings are averaged before multiday aggregation, and the baseline uses the corresponding combined readings.*\n\n- **Findings**: GlucoFM outperforms the GMI-equivalent baseline in all four settings. Because GMI compresses each window into an average-glucose-derived value, these gains demonstrate predictive information beyond mean-glucose-based stratification, potentially including glucose variability, excursions, and temporal patterns.\n---\n> 3. Human-subject ethics and data governance\n\nThe checklist’s “N/A” reflected our interpretation that no new recruitment or intervention occurred; we agree this was ambiguous and will correct it in the final manuscript.\n\n- **Approval and consent**: Both phases of the Wear-CGM study were approved by an independent IRB. All participants provided written informed consent explicitly permitting the use of de-identified data for secondary research and algorithm development. The present retrospective analysis falls within this consented scope.\n\n- **Data governance and minimization.** Although Wear-CGM contains multimodal measurements, this work uses only de-identified CGM data. Participant-level records remain access-restricted and will not be redistributed. All other raw datasets used in this work are previously released, de-identified research datasets accessed under their dataset-specific terms. No direct identifiers were available, and no re-identification was attempted.\n\n**To preserve double-blind anonymity**, we omit the IRB name, protocol identifiers, and institutional details during review. These details will be included in the final manuscript and can be provided confidentially to the Program or Ethics Chairs upon request.\n\n---\n> 4. Discussion, future work, and stakeholder guidance\n\nWe add three complementary evaluations to provide a more concrete translation roadmap while separating demonstrated research utility from unvalidated clinical deployment, all using frozen representations and subject-disjoint protocols. \n\n- **New TyG-defined fatty-liver-risk**: Among our downstream cohorts, only CGMacros, Shanghai, and Hall provide both fasting glucose and triglycerides required to construct the TyG label, TyG is calculated as $\\mathrm{TyG} = \\ln[(\\mathrm{TG} \\times \\mathrm{FPG})/2]$, with risk defined as TyG $>8.64$. We evaluate frozen representations using the same linear-probing protocol with 10 repeats of 5-fold subject-disjoint cross-validation as in Table 3.\n\n**Rebuttal Table 7. TyG-defined fatty-liver-risk linear probing (mean ± std, %)**\n\n| Dataset | Representation | PR-AUC | ROC-AUC | Macro-F1 |\n|:--|:--|--:|--:|--:|\n| CGMacros | **GlucoFM** | **83.5 ± 8.8** | **75.7 ± 10.8** | **66.6 ± 9.0** |\n| | Best baseline (CGMformer) | 81.2 ± 7.9 | 72.0 ± 9.2 | 64.5 ± 7.4 |\n| Shanghai | **GlucoFM** | **91.3 ± 4.5** | **66.5 ± 13.6** | **55.6 ± 8.1** |\n| | Best baseline (X-CGM-JEPA) | 91.2 ± 4.0 | 65.3 ± 11.7 | 54.5 ± 6.6 |\n| Hall | **GlucoFM** | **37.0 ± 9.5** | **58.9 ± 9.4** | **53.1 ± 7.8** |\n| | Best baseline (CGM-JEPA) | 33.9 ± 7.4 | 55.1 ± 9.4 | 50.4 ± 6.4 |\n\n- **Findings**: GlucoFM achieves the highest PR-AUC, ROC-AUC, and Macro-F1 across all three cohorts, although Shanghai PR-AUC is nearly tied. This extends the submitted benchmark **from 7 to 8 classification tasks** and provides cross-cohort evidence for a laboratory-derived metabolic-risk proxy, not imaging-confirmed fatty-liver diagnosis.\n\n---\n\n- **New postprandial glucose-response (PPGR)**: Among our downstream cohorts, only CGMacros provides aligned quantitative meal logs required for PPGR prediction. We use 34 participants and the same 800 quality-controlled meal events for Dexcom and Libre, with the two sensors trained and evaluated separately under identical subject splits. Each model receives a frozen embedding of the strictly causal 24-hour pre-meal CGM window, identical nutrition features, and the same explicit 1-hour pre-meal glucose context. The same MLP settings predict the complete 3-hour glucose-delta trajectory. Evaluation uses 5 fixed subject-disjoint folds and 10 complete out-of-fold runs. \n\n**Rebuttal Table 8. Three-hour PPGR trajectory MAE (mg/dL)**\n\n| Representation | Dexcom | Libre | Cross-sensor mean |\n|:--|--:|--:|--:|\n| No frozen embedding | 24.8 ± 0.1 | 24.3 ± 0.2 | 24.6 |\n| CGM-JEPA | 24.7 ± 0.2 | 22.8 ± 0.2 | 23.8 |\n| X-CGM-JEPA | 25.2 ± 0.2 | 22.2 ± 0.3 | 23.7 |\n| GluFormer | 26.2 ± 0.2 | 23.0 ± 0.2 | 24.6 |\n| CGMformer | 26.1 ± 0.4 | 24.7 ± 0.2 | 25.4 |\n| **GlucoFM** | **23.6 ± 0.2** | **22.1 ± 0.3** | **22.8** |\n\n*Cross-sensor mean is the unweighted mean of the two sensor-specific MAEs, not a fused-sensor result.*\n\n- **Findings**:\n - The three lowest cross-sensor mean MAEs are obtained by JEPA-style models, suggesting a potential advantage of predictive latent learning in this setting.\n - Among tested biomarkers and subject characteristics, adding fasting glucose, HbA1c, BMI, and diabetes status achieved the lowest cross-sensor MAE of 22.3 mg/dL.\n\n---\n- **New biomarker regression analysis**: We extend the submitted categorical evaluation to continuous biomarkers. Fasting plasma glucose (FPG) and HbA1c are evaluated across CGMacros, Hall, Shanghai, and Stanford; HOMA-IR and fasting insulin are evaluated across CGMacros, Hall, and Shanghai, the cohorts containing the required measurements. For $K\\in\\{1,3,5\\}$, frozen daily embeddings are mean-pooled and evaluated using the same linear Ridge probe with nested subject-grouped 5-fold cross-validation across 5 repeated partitions. For space, Table 9 reports the single-day $K=1$ results.\n\n**Rebuttal Table 9. $K=1$ biomarker regression MAE**\n| Target | GlucoFM | Best baseline | Train-mean |\n|:--|--:|--:|--:|\n| FPG (mg/dL) | **20.8 ± 0.1** | 21.5 ± 0.5 (CGMformer) | 34.1 |\n| HbA1c (%) | **0.90 ± 0.03** | 0.99 ± 0.03 (CGMformer) | 1.51 |\n| HOMA-IR | **2.60 ± 0.01** | 2.63 ± 0.03 (GluFormer) | 2.78 |\n| Fasting insulin (μU/mL) | 8.47 ± 0.08 | **8.46 ± 0.03** (GluFormer) | 8.50 |\n\n*Train-mean is a non-representation baseline that predicts each test subject using the target mean from the corresponding training fold.*\n\n- **Findings**:\n - At $K=1$, GlucoFM achieves the lowest MAE for FPG, HbA1c, and HOMA-IR. For fasting insulin, GlucoFM, GluFormer, and train-mean perform comparably, indicating limited predictive signal from a single day of CGM.\n - Across $K=1, 3, 5$, GlucoFM achieves the lowest MAE in 10/12 settings and lower MAE than train-mean in 12/12, extending the evaluation from categorical outcomes to continuous biomarkers.\n\n---\nIn summary, GlucoFM combines a novel CGM-specific dual-stream architecture with, to our knowledge, one of the most comprehensive evaluations among existing CGM FMs, spanning classification, forecasting, and regression. Additional analyses demonstrate functional pre-fusion stream specialization (Kkgy, Rebuttal Table 1), while frozen GlucoFM outperforms fully fine-tuned Chronos-2-small and MOMENT-small on all 3 metrics across 7 evaluations (rPuz, Rebuttal Table 4).\n\nWe hope these clarifications and new results address the reviewer’s concerns and invite reconsideration of the rating."+ },+ "createdAt": "2026-07-27T02:53:40.026Z",+ "modifiedAt": "2026-11-18T17:11:19.452Z",+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP¬eId=vbAJdxbpgd",+ "license": "CC-BY-4.0"+}
reviews/openreview/sxwz7kj3kp/submission.json added
+++ b/reviews/openreview/sxwz7kj3kp/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "SxWZ7KJ3KP",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 3746,+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP",+ "license": "CC-BY-4.0"+}
versions/v_m4bjemey.json added
+++ b/versions/v_m4bjemey.json@@ -0,0 +1,22 @@+{+ "date": "2026-04-21",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 3746,+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP",+ "reviews": "openreview/sxwz7kj3kp",+ "evidence": [+ "https://openreview.net/forum?id=SxWZ7KJ3KP"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=SxWZ7KJ3KP",+ "evidence": [+ "https://openreview.net/forum?id=SxWZ7KJ3KP"+ ]+}