Prior as Geometry, Not Generator: Weak-Diffusion Test-Time Reconstruction for Dynamic MRI
Import NeurIPS 2026 submission UbC0NrVCfU: 8 notes
@openreview[bot] · 2026-11-22 17:57 UTC · 024948aa9364 ·
reviews/openreview/ubc0nrvcfu/forms.json added
+++ b/reviews/openreview/ubc0nrvcfu/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/1lwwyif8ba.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/1lwwyif8ba.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "1LWwyIf8bA",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair kVhH",+ "content": {+ "metareview": "This manuscript suggests a method for MR reconstruction with the classical understampled k-space case, but in the Dynamic MRI collection setting, where ground truth k-space is very difficult to collect. It establishes a learned prior, to be used in place of the (inaccessible) true fully sampled data.\n\nAll reviewers found it hard to connect theory results to any guarantee of performance, and several reviewers found the results lackluster. In my opinion, authors should attempt to reconcile these views (or clarify any misconceptions about the theory, e.g., that they \"follow directly from definitions\") in the Rebuttal.\n\nMultiple reviewers offer complaints about baselines. I think it is reasonable to skip baselines given justification, or comparison to a superseding baseline, but those justifications should be made. \n\nMRI is clinically a visual and qualitative modality (at least for most contrasts). Following up on `mdsH`'s line of questions about visual differences would be beneficial to the manuscript.\n\nI tend to agree that this can get \"over the bar\", but I think that theory connections and questions need to be resolved before moving forward."+ },+ "createdAt": "2026-07-21T20:51:22.950Z",+ "modifiedAt": "2026-11-18T15:18:51.015Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=1LWwyIf8bA",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/5bhv4nwqoz.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/5bhv4nwqoz.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "5bHV4nWQoz",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer mdsH",+ "content": {+ "summary": "This paper addresses the important and challenging problem of reconstructing dynamic MR images from under-sampled k-space data. It is infeasible to obtain sufficient \"fully sampled\" k-space data in the dynamic setting for training excellent priors, so the paper proposes a combination of a time-dependent deep imaging \"prior\" (TD-DIP) that uses no training data with a \"weak\" diffusion prior. \nThe method first applies a standard diffusion/Tweedie denoiser per (3), and then combines that with the measurement negative log-likelihood per (7). At this point, a typical diffusion method would perform (unconstrained) minimization of (7) using CG, whereas the proposed method uses TD-DIP as a manifold constraint per (8). This is a logical approach.\n\nThere is some theoretical analysis of the method, and empirical results show PSNR/SSIM values ranked 1st or 2nd among several baselines, with HashINR being a close contender. The proposed method had the highest PSNR for the largest acceleration factors.\n\nThe approach could be relevant to other inverse-problem applications where there is limited data for training a diffusion prior. The central use of TD-DIP here makes it a \"use-inspired\" contribution with dynamic MRI as the principal application.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths \n\nThe absence of well-trained diffusion priors for dynamic MRI make this topic an important one. If there existed a \"somewhat well trained\" diffusion prior, then test-time refinement of that prior would be a serious contender here that would seem more interpretable than the proposed combination. Such refinement approaches have been effective for 2D inverse problems, but I haven't seen 2d+time or 3d+time approaches for refining diffusion models, probably because it is so challenging to train Nd+time diffusion priors. So the conglomeration of diffusion priors with TD-DIP is a reasonable strategy at this point in time, although hopefully in the long run it will be made obsolete by test-time refinement of diffusion priors. \n\nConcerns \n\nL79 claims that the method \"couples two complementary priors\" (diffusion and TD-DIP), but nowhere do I see a proposed p(x) expression. The problem here is probably that the \"P\" in DIP is for \"prior,\" yet it is not really a prior but really just a regularizer or constraint. I am unconvinced that the proposed method is really \"Bayesian\" as claimed in L78. To be Bayesian, the paper should describe p(x) or at least ∇ log p(x). \n\nClarity \n\nI don't see where Figures 1 or are cited in the text. The first reference to a figure in the text is to Fig. 8!? Fig. 2 is extremely small and the GT image is so far from the proposed method that one cannot zoom to see details side-by-side.\n\nEverything up to (10) is clear. I found it hard to follow (11)-(17) in part due to uncommon terms like \"geometric gating\" and \"dual-proxy control\" and \"structural innovation\" none of which appear in typical dynamic MRI papers. Similar terms abound in the theory in Section 3. Hopefully other reviewers can better assess this section. \n\nQuality \n\nThe only results are some PSNR/SSIM metrics; these are popular in the ML/CV community, but they are far from relevant to how dynamic MRI images are used in practice. The authors should read this recent editorial on leaderboard metrics https://doi.org/10.1002/mrm.70377 and then tone down the claims about \"gains\" and \"improve\" and \"superior fidelity\" and \"high-fidelity\" and simply report what has been shown: somewhat higher PSNR. Simple low-pass filtering can often increase PSNR while losing the fine details crucial for diagnosis. The results do not demonstrate any improvements in the actual use case of dynamic MRI - just PSNR values.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "Assumption 3.2 is a kind of strong convexity that seems quite strong for highly undersampled A. Why is that assumption reasonable?\n\nDo any of the theoretical analysis results establish performance guarantees for the method? (It didn't seem so to me.)\n\nDid you consult with any domain experts (e.g., radiologists) to get feedback on your image quality? In particular, are the images acceptable to a radiologist at the highest acceleration factors (where the improvements are most noticeable)?",+ "limitations": "The limitations focus on computational time, but do not address the limitations of using PSNR as a metric in medical imaging.",+ "rating": 4,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "none",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "Based on the authors' very good response, I would have bumped my recommendation from borderline accept to accept, as a use-inspired method. But then the PCs bugged me for not selecting the \"general\" category that was (unwisely?) selected by the authors.\nThere is solid MRI work here, but I don't really see the relevence to the general ML community, so that brings it back down to to \"borderline accept\" which is where I started."+ },+ "createdAt": "2026-06-07T14:50:49.597Z",+ "modifiedAt": "2026-11-18T13:35:37.513Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=5bHV4nWQoz",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/cmrggcuqjq.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/cmrggcuqjq.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "cmrGgcUqjQ",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Thc9",+ "content": {+ "summary": "This paper proposes Geometry-Gated TD-DIP for dynamic MRI reconstruction under a “weak diffusion” setting. The core idea is to use a pretrained, potentially mismatched 2D diffusion model not as a dominant generative prior, but as a local geometric reference. At each reverse step, the method computes a Tweedie anchor from the diffusion model, fits a scan-specific TD-DIP reconstruction through a proximal objective, decomposes the TD-DIP correction into diffusion-tangent and orthogonal components, and adaptively gates the orthogonal innovation before the sampler update. The paper reports strong empirical results on dynamic cardiac MRI, including high acceleration, cross-vendor generalization, and prior-mismatch experiments.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "While the empirical performance is promising, I found the conceptual positioning and theoretical justification insufficiently convincing. The method entangles several factors: test-time optimization, TD-DIP temporal modeling, a frozen 2D diffusion prior, tangent-normal decomposition, and adaptive gating. As a result, it is difficult to determine whether the gains come from the proposed geometric mechanism or from the broader benefit of combining a dynamic scan-adaptive INR/DIP with a weak spatial diffusion prior. The relationship to prior work on test-time diffusion-prior adaptation, especially DDIP[1] and SCD[2], should also be made much clearer.\n\n### Strengths\n\n- The paper addresses an important and practical problem: dynamic MRI reconstruction under aggressive undersampling and diffusion-prior mismatch.\n- The proposed method is intuitively reasonable. Using diffusion as a weak stabilizing anchor while letting TD-DIP recover scan-specific dynamics is a plausible design.\n- The empirical results are strong across multiple undersampling settings\n\n### Weaknesses\n\nThe paper is generally hard to read, with several components not fully justified along the way. \n- L87: DPS places a dirac approx with $\\mu_k \\rightarrow \\infty$. One that places a Gaussian is $\\Pi$GDM [3].\n- Sec 2.5. needs more explanation. What do the authors mean by \"manifold-constraint view\"? \n\nThe theoretical analysis is weak. Several results are essentially consequences of definitions rather than meaningful guarantees.\n- The assumptions behind the theory are strong and not well justified. For instance, Assumption 3.2 requires restricted data curvature on the TD-DIP manifold. In highly undersampled dynamic MRI, this is precisely the kind of identifiability condition that is hard to expect without evidence.\n- Assumption 3.4 is also questionable. The theory assumes the denoiser Jacobian is close to an oracle tangent map, non-expansive, and approximately idempotent. This is a very strong assumption for a pretrained, intentionally mismatched diffusion model.\n- The positioning relative to DDIP is insufficient. DDIP also addresses OOD diffusion-prior adaptation for inverse problems using a proximal test-time objective, but adapts the *diffusion model* parameters rather than a separate DIP/INR network. The present paper is algorithmically different, but the high-level motivation is closely related. The novelty should be framed more carefully as frozen-diffusion geometry plus TD-DIP adaptation, rather than as an entirely new weak-diffusion paradigm.\n- Important ablations are missing. In particular, the paper should disentangle 2D vs dynamic diffusion priors, frozen diffusion vs diffusion-parameter adaptation, TD-DIP architecture effects, and the actual contribution of the tangent-normal gate under matched compute.\n\n**Minor**\n\n- L88: Is $mu_k$ the anchor *strength*? I'm confused since this is inverse.\n\n### References\n\n[1] Chung, Hyungjin, and Jong Chul Ye. \"Deep diffusion image prior for efficient ood adaptation in 3d inverse problems.\" ECCV 2024.\n\n[2] Barbano, Riccardo, et al. \"Steerable conditional diffusion for out-of-distribution adaptation in medical image reconstruction.\" IEEE Transactions on Medical Imaging 44.5 (2025): 2093-2104.\n\n[3] Song, Jiaming, et al. \"Pseudoinverse-Guided Diffusion Models for Inverse Problems\", ICLR 2023",+ "quality": 2,+ "clarity": 2,+ "significance": 2,+ "originality": 2,+ "questions": "- Why is a 2D diffusion prior the appropriate object for defining tangent geometry in a dynamic 2D+t reconstruction problem? Would the method still provide gains if the diffusion prior were a dynamic 2D+t diffusion model?\n- How much of the improvement comes from the proposed tangent-normal gating, versus simply combining a frozen 2D spatial diffusion prior with a strong dynamic TD-DIP model?\n- Can the authors compare against or discuss DDIP more directly? \n- Can the authors empirically validate Assumption 3.2 by reporting singular values or conditioning?\n- Can the authors empirically validate Assumption 3.4 by measuring whether the denoiser Jacobian is actually near-idempotent, non-expansive, or projection-like under matched and mismatched priors?",+ "limitations": "yes",+ "rating": 3,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I appreciate the authors’ substantial effort in the rebuttal, including the stronger baselines, radiologist evaluation, ablations, and more careful theoretical framing. However, my main concern remains unresolved: the revised theory is considerably weaker than the original geometric interpretation, providing only conditional local bounds and an essentially algebraic characterization of the gate, without explaining when the residual correction is actually beneficial for reconstruction. The new experiments strengthen the empirical case, but I view them as supporting a useful dynamic-MRI-specific method rather than establishing the broader methodological or theoretical contribution claimed by the paper. Overall, the rebuttal improves the work, but not enough to outweigh my concerns about significance and the informativeness of the theoretical contribution, so I maintain my score of 3."+ },+ "createdAt": "2026-06-02T07:29:52.802Z",+ "modifiedAt": "2026-11-18T13:35:40.607Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=cmrGgcUqjQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/hbxwgoxwqx.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/hbxwgoxwqx.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "hbXwGOxWQX",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "This manuscript suggests a method for MR reconstruction with the classical understampled k-space case, but in the Dynamic MRI collection setting, where ground truth k-space is very difficult to collect. It establishes a learned prior, to be used in place of the (inaccessible) true fully sampled data.\n\nAll reviewers found it hard to connect theory results to any guarantee of performance, and several reviewers found the results lackluster. In my opinion, authors should attempt to reconcile these views (or clarify any misconceptions about the theory, e.g., that they \"follow directly from definitions\") in the Rebuttal.\n\nMultiple reviewers offer complaints about baselines. I think it is reasonable to skip baselines given justification, or comparison to a superseding baseline, but those justifications should be made. \n\nMRI is clinically a visual and qualitative modality (at least for most contrasts). Following up on `mdsH`'s line of questions about visual differences would be beneficial to the manuscript.\n\nI tend to agree that this can get \"over the bar\", but I think that theory connections and questions need to be resolved before moving forward.",+ "final_justification": "I find that the responses in rebuttal have adequately answered questions posed by reviewers, and in particular the ones I directed them towards.\n\nI am going to upweight `mdsH`'s assessment that this should be published, and down weight there category assessment; the results presented in this paper (both empirical and theoretical) may be fairly specific to MRI currently, but may have indirect relevance to other signal processing/imaging applications, or more broadly learned \"reconstruction\"."+ },+ "createdAt": "2026-09-24T11:16:52.897Z",+ "modifiedAt": "2026-11-18T14:52:42.344Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=hbXwGOxWQX",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/mxjxx37scv.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/mxjxx37scv.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MxJXx37ScV",+ "replyTo": "WnsVDI6bib",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your time and review comments. We accept the reviewers' suggestions regarding the structure of the manuscript. Next, we will address the reviewers' concerns and questions. \n\n### **On W1 & Q1 Scope of application of the method**:\n---\nWe agree that validation using contrast injection dynamic MRI is required to establish the method's general applicability. However, as such data are not currently available, we will limit the scope of all claims to the domain of cardiac dynamic MRI. We will present this aspect as a subject for future work.\n\n### **On Q2 Results of CMRxRecon2025 and OCMR**:\n---\nThe experimental results in **Table 1** were obtained using an in-house cardiac cine dataset. For detailed information about the dataset, please refer to **Appendix B.1**. The experimental results for the **CMRxRecon2025** dataset are presented in **Table 6**. Experiments conducted on the **OCMR dataset** can be found in **Appendix F, and the relevant charts are Table 7, Table 8, and Figure 9**.(All the charts mentioned above refer to those in the manuscript, not the rebuttal)\n\n### **On L1 & W6 Execution times of different methods**:\n---\nThank you for pointing this out we have added the running times for the different methods—please refer to the **Table 1** for details. Due to differences in computational workflows, we focused our comparison on unsupervised reconstruction methods. We will also include relevant runtime tables in the revised version.\n\nTable 1. Single-sample runtime and peak GPU memory usage of different methods using the VISTA mask.\n\n| Method | Runtime (s) | Peak Alloc (GB) |\n| :------------ | :---------- | :-------------- |\n| Ours | 309.59 | 12.01 |\n| TD-DIP | 278.36 | 10.12 |\n| SVI-Diffusion | 33.88 | 8.59 |\n| HashINR_tTVLR | 11.88 | 13.05 |\n\nMeasurements of runtime and memory usage were conducted on an A800 GPU using the cardiac cine dataset from this study, with all methods employing identical reconstruction settings.\n\nAs can be seen from the table, the primary time cost stems from TD-DIP. Compared to TD-DIP, our method incurs only a small amount of additional time and memory overhead. As shown in **Figure 2 and Table 1** of the original paper, this small amount of additional computational cost yields higher reconstruction quality, which is particularly evident in high-rate undersampling scenarios.\n\nWe also took into account the most time-consuming sampling scenario: radial sampling. We compared our method with TD-DIP and HashINR_tTVLR under the condition of 38.4× accelerated sampling. We introduce an acceleration strategy that reduces the number of TD-DIP iterations, trading a slight loss in quality for significant time savings. Please refer to the **Table 2** for details.\n\nTable 2. Runtime, GPU memory usage, and reconstruction quality of different methods under golden-angle radial sampling.\n\n| Method | Runtime (s) | Peak Alloc (MiB) | PSNR (dB) |\n| :------------------- | :---------- | :--------------- | --------- |\n| TD-DIP | 1071.98 | 1911 | 41.523 |\n| HashINR_tTVLR | 890.85 | 19377 | 42.214 |\n| Ours (Full steps) | 1336.92 | 6183 | 43.469 |\n| Ours (Half steps) | 758.63 | 6183 | 42.959 |\n| Ours (Quarter steps) | 472.23 | 6183 | 41.879 |\n\n### **On L2 & W7 Baseline method**:\n---\nThank you to the reviewer for the references provided. Following the reviewers' suggestions, we further compared our approach with the method proposed in [3]. This method represents a strong baseline for supervised model-based reconstruction, offering a fairer and more representative comparison than the original MoDL. \n\nThe official weights are primarily derived from the CMRxRecon2024 dataset, which differs from our cine test data. We conducted experiments using two approaches: the official weights and a model fine-tuned on the official weights. \n\nFor model fine-tuning, we perform supervised fine-tuning using the training set from the cardiac cine dataset and the VISTA 12×/24× masks consistent with the main experiments in this paper. The corresponding test sets were used for testing, along with PSNR and SSIM calculation procedures identical to those employed by the main method proposed in this paper. For specific results, see **Table 3**.\n\nTable 3. Experimental results of the PromptMR+ method\n\n| Mask | Model | PSNR | SSIM |\n| --------- | ---------- | -------------- | ----------- |\n| VISTA 12× | Released | 27.610 ± 1.369 | 0.72 ± 0.03 |\n| VISTA 12× | Fine-tuned | 43.898 ± 1.723 | 0.98 ± 0.01 |\n| VISTA 24× | Released | 22.846 ± 0.883 | 0.60 ± 0.02 |\n| VISTA 24× | Fine-tuned | 39.273 ± 1.901 | 0.96 ± 0.01 |\n\nCompared to the traditional MoDL method, this method demonstrates significant performance improvement. It also demonstrates that the method proposed in this paper can provide high-quality reconstruction results. We will also include the complete test results in the revised version.\n\n### **On W2 & W3 & W4 Manuscript organization and content presentation**:\n---\nWe thank the reviewers for carefully reading our manuscript. We accept the reviewer's suggestions regarding the organization of the content and will adjust the relevant sections in the revised version."+ },+ "createdAt": "2026-07-28T07:47:43.621Z",+ "modifiedAt": "2026-11-18T17:11:23.451Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=MxJXx37ScV",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/tf642qdcfc.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/tf642qdcfc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "tF642qDcfc",+ "replyTo": "cmrGgcUqjQ",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewer for the detailed theoretical critique.\n\n### **On W1 Incorrect statement:**\n---\nThe local Gaussian approximation should not be attributed to standard DPS as stated in the original manuscript. We will revise this statement and distinguish between the Dirac approximation used in DPS and the Gaussian local modeling in the relevant guided diffusion formula.\n\n### **On W2 Manifold-constraint view:**\n---\nIn our paper, this term refers to the implicit constraint introduced by the scan-specific TD-DIP parameterization, rather than an explicitly known or globally defined data manifold. Specifically, TD-DIP defines a feasible image set $M_k=\\{x_\\phi|\\phi\\in V_k\\}$ and the Stage-B optimization searches within this set instead of the full image space. Separately, the diffusion Jacobian $J_{\\theta,k}=\\nabla_xD_{\\theta,k}(x_k)$ is used to describe the local sensitivity of the denoiser and guide the correction decomposition. \n\nWe agree that the original wording may have caused ambiguity, and we will revise the manuscript to distinguish TD-DIP as an implicit image-set constraint and the diffusion Jacobian as a local sensitivity operator, rather than implying a rigorously defined data manifold or an exact tangent projector.\n\n### **On W3 & Q4 Assumption 3.2:**\n---\nDue to space constraints, please refer to the section **\"On Q1 Assumption 3.2\"** in the rebuttal addressing reviewer **mdsH**.\n\n### **On W4 & Q5 Assumption 3.4**:\n---\n\nWe agree that a learned, intentionally mismatched denoiser Jacobian should not be assumed to be an exact orthogonal tangent projector. We therefore revise the decomposition from\n$$\nd_k^\\parallel=J_{\\theta,k}d_k, \\qquad d_k^\\perp=(I-J_{\\theta,k})d_k\n$$\n\nto\n\n$$\nd_k^{\\mathrm{sens}} = J_{\\theta,k}d_k, \\qquad d_k^{\\mathrm{res}} = (I-J_{\\theta,k})d_k,\n$$\n\nwhich we call the **prior-sensitive** and **prior-residual** components. The algorithm itself is unchanged.\n\nDefine\n\n$$\nG_{\\theta,k}(\\lambda) = \\lambda I+(1-\\lambda)J_{\\theta,k}.\n$$\n\nFor any reference sensitivity operator $J_{r,k}$ ,\n\n$$\nG_{\\theta,k}(\\lambda) - G_{r,k}(\\lambda) = (1-\\lambda) (J_{\\theta,k}-J_{r,k}).\n$$\n\nTherefore,\n\n$$\n \\||G\\_{\\theta,k}(\\lambda)d - G\\_{r,k}(\\lambda)d\\||\\_2 \\leq (1-\\lambda) \\||J\\_{\\theta,k}-J_{r,k}\\||\\_2 \\||d\\||\\_2. \\tag{1}\n$$\n\nEquation (1) requires neither idempotence, symmetry, non-expansiveness, nor an orthogonal-projection interpretation. Its meaning is direct: a larger $\\lambda$ makes the update closer to the complete TD-DIP correction and reduces sensitivity to disagreement between the weak diffusion operator and the reference operator.\n\nSimilarly,\n\n$$\n\\widetilde x_{0,k} - x_k^{\\mathrm{DIP}} = -(1-\\lambda_k) (I-J_{\\theta,k})d_k,\n$$\n\nso\n\n$$\n \\||\\widetilde x\\_{0,k} - x_k^{\\mathrm{DIP}}\\||\\_2 = (1-\\lambda_k) \\||(I-J\\_{\\theta,k})d_k\\||\\_2. \\tag{2}\n$$\n\nEquation (2) quantifies the gate-induced deviation from the full TD-DIP update. It does not claim that this deviation necessarily lowers the reconstruction error.\n\nWe evaluated the three diffusion priors used in the paper at matched reconstruction states using JVPs and VJPs. The empirical symmetry residual\n\n$$\n\\frac{\\||(J-J^H)v\\||_2}{\\||v\\||_2}\n$$\n\nranged from 0.008 to 0.067. Other projection-related quantities, including the operator gain and idempotence residual, varied across prior types and reverse stages.\n\nWe also measured discrepancies between the matched-prior operator and the two weaker operators. In the middle and late reverse stages, the matched-to-OOD discrepancy was larger than the matched-to-generic discrepancy, consistent with the ordering of prior mismatch.\n\nThese observations support the revised formulation: the Jacobian is informative as a local sensitivity operator, but its projector-like properties should be treated as diagnostics rather than necessary assumptions.\n\nWe will therefore remove non-expansiveness and near-idempotence from the assumptions required by the main mismatch result.\n\n### **On W5 & Q3 DDIP:**\n---\nWe agree that both DDIP and the present paper focus on the test-time adaptation of diffusion priors for OOD inverse problems; thus, they are closely related in terms of high-level motivation. The original manuscript did not sufficiently highlight this relationship.\n\nDDIP primarily targets **static** 2D and 3D inverse problems. In contrast, this paper specifically addresses dynamic MRI, employing TD-DIP to construct a shared temporal implicit manifold within a single scan, thereby recovering inter-frame dynamics and temporal consistency. And DDIP differs from the method in this paper regarding the role of the diffusion model.\n\nTo facilitate a direct comparison, we supplemented our study with DDIP experiments conducted on the full cardiac cine test set (118 cases). All methods employed the same experimental settings and fixed VISTA 12×/24× masks as described in the paper. For DDIP, we utilized the publicly available fastMRI checkpoint, official hyperparameters, and a fixed random seed, without performing dataset-specific hyperparameter tuning.\n\nAs the public DDIP implementation was not specifically designed for dynamic MRI, we evaluated two plausible implementations: DDIP-2D, which applies the official 2D solver frame-by-frame; and D3IP-Time, which maps the temporal dimension to the third dimension of D3IP and shares LoRA parameters. The results are presented in **Table 1**.\n\nTable 1. Comparison of different DDIP implementations and the method proposed in this paper.\n\n| method | VISTA AF | PSNR (dB) ↑ | SSIM ↑ |\n| --------- | -------- | -------------- | ----------- |\n| DDIP-2D | 12× | 29.213 ± 1.276 | 0.67 ± 0.02 |\n| D3IP-Time | 12× | 17.608 ± 3.415 | 0.40 ± 0.05 |\n| Ours | 12× | 45.769 ± 1.924 | 0.98 ± 0.01 |\n| DDIP-2D | 24× | 24.179 ± 1.742 | 0.55 ± 0.03 |\n| D3IP-Time | 24× | 18.314 ± 1.966 | 0.35 ± 0.05 |\n| Ours | 24× | 42.129 ± 1.848 | 0.96 ± 0.01 |\n\nWe attribute this discrepancy primarily to the approaches employed for dynamic sequence modeling. DDIP-2D processes each time frame independently, failing to leverage temporal information across adjacent frames; conversely, D3IP was originally designed for 3D volumetric data, and interpreting its third dimension merely as time allows only for parameter sharing without explicitly modeling cardiac motion. The TD-DIP method proposed in this paper performs scan-specific fitting across the entire spatiotemporal sequence. This design reduces reliance on the quality of the diffusion prior fit in situations where the static prior and dynamic data do not perfectly align.\n\nThese results do not imply that DDIP is ineffective for the static inverse problems for which it was originally designed; rather, they indicate certain limitations in dynamic scenarios. We will include this comprehensive comparison in the revised manuscript. In addition, we will briefly discuss methods such as SCD in the \"Related Work\" section.\n\n### **On W6 & Q2 Ablation experiment:**\n---\nWe conducted additional, more comprehensive ablation experiments. The newly added experimental setup eliminates vector decomposition and gating mechanisms, relying entirely on TD-DIP to guide the diffusion-based reconstruction. The results are shown in **Table 2**.\n\nTable 2. Ablation study on the effectiveness of key components using VISTA mask at 12× acceleration.\n| Diffusion | TD-DIP | Projection Strategy | PSNR (dB) | SSIM (×10⁻²) |\n| --------: | -----: | -------------------- | ---------------: | ---------------: |\n| ✓ | – | MCG | 34.25 ± 1.18 | 84.17 ± 3.07 |\n| – | ✓ | – | 41.45 ± 1.84 | 95.67 ± 1.06 |\n| ✓ | ✓ | MCG (Naive) | 43.92 ± 1.57 | 97.74 ± 0.69 |\n| ✓ | ✓ | – | 45.05 ± 1.88 | 98.14 ± 0.70 |\n| ✓ | ✓ | **Geometric (Ours)** | **45.77 ± 1.92** | **98.27 ± 0.68** |\n\nThe results demonstrate that each component of the proposed method contributes to the reconstruction performance.\n\n### **On Q1: 2D + t Diffusion model**\n---\nThe apparent dimensional mismatch results from an overly compressed description in the submitted paper. We do not claim that the 2D denoiser Jacobian represents the complete tangent geometry of the dynamic (2D+t) image manifold.\n\nLet $X=(x_1,\\ldots,x_T)$ denote a dynamic sequence. The 2D diffusion model provides a frame-wise spatial sensitivity operator:\n\n$$\nD_{\\theta}^{\\mathrm{seq}}(X)\n(D_{\\theta}(x_1),\\ldots,D_{\\theta}(x_T)),\n$$\n\nwhose sequence-level Jacobian is approximately block diagonal,\n\n$$\nJ_{\\theta}^{\\mathrm{seq}}\n\\operatorname{diag}(J_{\\theta,1},\\ldots,J_{\\theta,T}).\n$$\n\nThis operator only describes spatial prior sensitivity. Temporal coupling is provided by the shared TD-DIP parameters and the temporal latent encoding, which generate the entire sequence jointly.\n\nWe address scenarios where task-specific dynamic (2D+t) diffusion priors are unavailable or come with high training costs. The 2D diffusion model is therefore used as a weak spatial reference, while TD-DIP supplies scan-specific temporal structure and measurement consistency."+ },+ "createdAt": "2026-07-28T09:51:53.837Z",+ "modifiedAt": "2026-11-18T17:11:24.000Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=tF642qDcfc",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/wnsvdi6bib.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/wnsvdi6bib.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "WnsVDI6bib",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 9AfB",+ "content": {+ "summary": "The authors propose Geometry-Gated Time-Dependent Deep Image Prior (TD-DIP) for highly undersampled dynamic MRI reconstruction. In their method, diffusion prior is used as a local geometric reference, and each TD-DIP update is decomposed into a diffusion-consistent tangent component and a measurement-supported orthogonal component. The self-calibrated gate can adaptively regulate the orthogonal component to counter prior mismatch while suppressing noise amplification. The proposed method was validated on two public cardiac cine MRI dataset and a synthetic moving-ellipses dataset. The results show that it can outperform baseline methods for highly undersampled cine MRI reconstruction and can generalize well under out-of-distribution diffusion priors.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\n1. The proposed method can combine the advantage of both pretrained diffusion prior and untrained test-time prior into a single framework. \n2. The self-calibrated gate can adaptively regulate the orthogonal component of each TD-DIP update to counter prior mismatch while suppressing noise amplification.\n3. The proposed method can improve the performance on highly undersampled dynamic MRI reconstruction and can generalize well under out-of-distribution diffusion priors. \n\nWeaknesses:\n1. Although the proposed method was claimed to be applicable to dynamic MRI reconstruction, the authors only validated it on cardiac cine MRI. The authors should also conduct experiments on other forms of dynamic MRI, such as contrast injection dynamic MRI, to test the broad application scope of their method.\n2. The ablation study was placed in the Appendix, which is improper. It is better to include the ablation study in the main content.\n3. It is better to include the Related Work section in the main content. \n4. The Theoretical Analysis section can be placed in the Appendix.\n5. Did you mix the results on CMRxRecon2025 and OCMR into Table 1? It is better to separately present the results on these two datasets as you were testing different aspects of your method.\n6. The authors should report the inference time of different MRI reconstruction methods.\n7. The baseline supervised unrolled method (MoDL) is old. The authors should use newly proposed deep unrolled models for comparison:\n\n(1) Xin, B., Ye, M., Axel, L. and Metaxas, D.N., 2024, September. Rethinking deep unrolled model for accelerated MRI reconstruction. In European Conference on Computer Vision (pp. 164-181). Cham: Springer Nature Switzerland.\n\n(2) Xin, B., Ye, M., Axel, L. and Metaxas, D.N., 2023, October. Fill the k-space and refine the image: Prompting for dynamic and multi-contrast MRI reconstruction. In International Workshop on Statistical Atlases and Computational Models of the Heart (pp. 261-273). Cham: Springer Nature Switzerland.\n\n(3) Xin, B., Ye, M., Axel, L. and Metaxas, D.N., 2024, October. Enhanced deep unrolled models applied to the cmrxrecon2024 challenge. In International Workshop on Statistical Atlases and Computational Models of the Heart (pp. 289-300). Cham: Springer Nature Switzerland.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Although the proposed method was claimed to be applicable to dynamic MRI reconstruction, the authors only validated it on cardiac cine MRI. The authors should also conduct experiments on other forms of dynamic MRI, such as contrast injection dynamic MRI, to test the broad application scope of their method.\n\n2. Did you mix the results on CMRxRecon2025 and OCMR into Table 1? It is better to separately present the results on these two datasets as you were testing different aspects of your method.",+ "limitations": "1. The authors should report the inference time of different MRI reconstruction methods.\n\n2. The baseline supervised unrolled method (MoDL) is old. The authors should use newly proposed deep unrolled models for comparison:\n\n(1) Xin, B., Ye, M., Axel, L. and Metaxas, D.N., 2024, September. Rethinking deep unrolled model for accelerated MRI reconstruction. In European Conference on Computer Vision (pp. 164-181). Cham: Springer Nature Switzerland.\n\n(2) Xin, B., Ye, M., Axel, L. and Metaxas, D.N., 2023, October. Fill the k-space and refine the image: Prompting for dynamic and multi-contrast MRI reconstruction. In International Workshop on Statistical Atlases and Computational Models of the Heart (pp. 261-273). Cham: Springer Nature Switzerland.\n\n(3) Xin, B., Ye, M., Axel, L. and Metaxas, D.N., 2024, October. Enhanced deep unrolled models applied to the cmrxrecon2024 challenge. In International Workshop on Statistical Atlases and Computational Models of the Heart (pp. 289-300). Cham: Springer Nature Switzerland.",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "1. The ablation study was placed in the Appendix, which is improper. It is better to include the ablation study in the main content.\n2. It is better to include the Related Work section in the main content. \n3. The Theoretical Analysis section can be placed in the Appendix.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I thank the authors for the detailed rebuttal. They have addressed my concerns. So, I would like to raise my rating from 3 to 4."+ },+ "createdAt": "2026-06-03T09:28:26.793Z",+ "modifiedAt": "2026-11-18T13:35:38.874Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=WnsVDI6bib",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/notes/xduxqxrpwa.json added
+++ b/reviews/openreview/ubc0nrvcfu/notes/xduxqxrpwa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xdUxqxrPwA",+ "replyTo": "5bHV4nWQoz",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We appreciate the reviewer's positive assessment of this work and constructive comments that helped us further refine the manuscript.\n\n### **On W1 Bayesian interpretation:**\n---\nWe agree that TD-DIP is not an explicitly normalized Bayesian prior: we do not define a density ${p}_{DIP}(x)$ or a corresponding score. We will therefore remove the statement that the method combines “two Bayesian priors.”\n\nThe revised formulation is\n\n$$ \\\\mathcal L_k(x) = \\\\frac{1}{2\\sigma\\_y^2}\\||Ax-y\\||\\_2^2 + \\frac{\\mu_k}{2}\\||x-\\widehat x\\_{0,k}\\||_2^2, \\qquad x\\in\\mathcal M\\_k,$$\n\nwhere $\\widehat x_{0,k}$ is the score-derived Tweedie anchor, $\\mu_k$ is its precision, and $\\mathcal M_k$ is the local TD-DIP image set. Thus, diffusion provides a local quadratic reference, while TD-DIP defines a scan-specific feasible set. We will use “score-anchored local surrogate” rather than “two-prior Bayesian MAP.”\n\n### **On W2 Clarity:**\n---\n\nThank you for pointing out the writing issues in the manuscript. We will add citations for all figures in the revised version to ensure a better reading experience for the audience. To address the issue of Figure 2 being too small, we will adjust the arrangement of the different comparison methods in the revised version so that the proposed method appears closer to the GT. We will replace “geometric gating,” “dual-proxy control,” and related shorthand by direct mathematical descriptions where possible, too.\n\n### **On W3 & Q3 & L1 Evaluation metrics:**\n---\n\nThe reviewers and the AC expressed concerns regarding the visual evaluation metrics for MRI. We read the editorial recommended by the reviewers and, in conjunction with Q3, invited two radiologists with more than three years of professional experience. to score the reconstruction results. We would like to express our gratitude to the two doctors.\n\nTwo radiologists independently evaluated dynamic MRI reconstructions generated by seven anonymized methods (labeled A–G; actual method names are used in the subsequent table) using a set of five randomly selected cases. A 5-point Likert scale was employed to rate overall image quality, structural detail, temporal consistency, and artifact suppression, with higher scores indicating superior performance. For each method, the radiologists' scores were first averaged within individual cases, followed by the calculation of the mean and standard deviation across all five cases. As shown in **Table 1**, our method achieved the highest mean scores across all four dimensions. Furthermore, we performed the Friedman chi-square test on five sets of paired cases; the results indicated significant differences among the seven methods across various dimensions (p < 0.001).\n\nTable 1: Reader-averaged radiologist scores\n\n| Method | Overall image quality | Structural detail | Temporal consistency | Artifact suppression |\n| :--------------------: | --------------------: | ----------------: | -------------------: | -------------------: |\n| L + S | 1.00 +/- 0.00 | 1.00 +/- 0.00 | 1.00 +/- 0.00 | 1.00 +/- 0.00 |\n| MoDL | 2.90 +/- 0.42 | 2.80 +/- 0.27 | 3.00 +/- 0.00 | 3.10 +/- 0.22 |\n| HashINR_tTVLR | 1.90 +/- 0.22 | 2.40 +/- 0.22 | 2.00 +/- 0.00 | 2.00 +/- 0.00 |\n| TD-DIP | 3.10 +/- 0.96 | 3.10 +/- 0.96 | 3.80 +/- 0.45 | 3.10 +/- 0.96 |\n| SVI-Diffusion | 1.00 +/- 0.00 | 1.00 +/- 0.00 | 1.00 +/- 0.00 | 1.00 +/- 0.00 |\n| Linear Fusion | 1.50 +/- 0.00 | 1.50 +/- 0.00 | 1.00 +/- 0.00 | 1.50 +/- 0.00 |\n| **Ours** | **3.60 +/- 0.55** | **3.60 +/- 0.55** | **4.30 +/- 0.27** | **3.20 +/- 0.67** |\n| Friedman chi-square(6) | 28.74 | 28.12 | 29.91 | 27.90 |\n| p-value | <0.001 | <0.001 | <0.001 | <0.001 |\n\nValues are mean +/- standard deviation across five cases after averaging the two reader scores within each case. Scores range from 1 to 5, and higher values indicate better quality. For artifact suppression, a higher score indicates fewer artifacts. The labels themselves contain certain artifacts, causing all methods to score slightly lower on the artifact intensity dimension.\n\nThe cases used were selected from experimental results involving VISTA 24x accelerated masking. The results demonstrate that our method achieves superior reconstruction quality at high acceleration factors; notably, for dynamic MRI, our method offers significant advantages in terms of temporal continuity.\n\n### **On Q1 Assumption 3.2:**\n---\n\nThe original condition was stated in the TD-DIP parameter space:\n\n$$\n\\||A J_{\\mathrm{DIP}}(\\phi)h\\||\\_2^2\n\\geq\n\\kappa_k\\||h\\||\\_2^2,\n\\qquad \\forall h\\in\\mathbb R^p,\n\\tag{1}\n$$\n\nwhere $J_{\\mathrm{DIP}}(\\phi)=\\nabla_\\phi x_\\phi$. This formulation may incorrectly suggest that every nonzero parameter perturbation must produce a distinguishable measurement change. For an overparameterized network, parameter symmetries or inactive directions may satisfy\n\n$$\nh\\neq 0,\n\\qquad\nJ_{\\mathrm{DIP}}(\\phi)h=0.\n$$\n\nSuch directions do not change the reconstructed image and are irrelevant to image recovery, but they violate Eq. (1). We will therefore restate the assumption at the image-space level actually required by the analysis.\n\nLet $\\phi_k^\\star$ be the Stage-B solution and define the local TD-DIP image set\n\n$$\nM_k = \\{x\\_\\phi:\\phi\\in V\\_k\\},\n$$\n\nwhere $V_k$ is a neighborhood of $\\phi_k^\\star$. The revised condition is\n\n$$\n\\||A(u-v)\\||\\_2\n\\geq\n\\alpha_k\\||u-v\\||\\_2,\n\\qquad\nu,v\\in M_k.\n\\tag{2}\n$$\n\nEquivalently, if\n\n$$\nS_k =\n\\\\left\\\\{\n\\\\frac{u-v}{\\\\|u-v\\\\|_2}\n\\\\mid\nu,v \\\\in M_k,\\\\ u \\\\neq v\n\\\\right\\\\}.\n$$\n\nthen\n\n$$\n\\\\alpha_k =\n\\\\inf_{q \\\\in S_k} \\\\|Aq\\\\|_2 > 0.\n\\\\tag{3}\n$$\n\nThis is not a claim that the highly undersampled operator $A$ is injective over the full image space. It only requires local injectivity on the structured image variations explored by TD-DIP:\n\n$$\n\\ker(A)\n\\cap\n\\\\{u-v:u,v\\in M_k\\\\} = \\\\{0\\\\}\n\\\\tag{4}\n$$\n\nThus, a large null space in the ambient image space does not automatically violate the assumption, provided that the local TD-DIP variations do not lie in that null space.\n\nThe corresponding infinitesimal condition follows from the local linearization. For\n\n$$\n\\phi(t)=\\phi_k^\\star+th,\n$$\n\nwe have\n\n$$\nx_\\\\phi(t) = x_{\\\\phi_k^\\\\star} + t J_{DIP}(\\\\phi_k^\\\\star)h + o(t).\n$$\n\nTherefore, the normalized local secant approaches an image-space tangent direction\n\n$$\nq = J_{\\mathrm{DIP}}(\\phi_k^\\star)h.\n$$\n\nThe tangent form of Eq. (2) is\n\n\n$$\n\\\\|Aq\\\\|_2\n\\\\geq\n\\\\alpha_k^{tan} \\\\|q\\\\|_2,\n\\\\qquad\nq \\\\in T_x^* M_k\n\\\\tag{5}\n$$\n\nUnlike Eq. (1), the right-hand side measures the induced image variation rather than the parameter variation, so parameter-null directions are automatically excluded.\n\n**Empirical validation**\n\nWe evaluated the tangent condition at early, middle, and late reconstruction stages under VISTA $12\\times$ and $24\\times$ undersampling. At each state, we sampled parameter directions $h_i$ and computed the induced image directions using Jacobian-vector products:\n\n$$\n\\widetilde q_i = J_{\\mathrm{DIP}}(\\phi_k^\\star)h_i.\n$$\n\nAfter normalization and orthonormalization, these directions formed\n\n$$\nQ_k=[q_1,\\ldots,q_r],\n\\qquad\nQ_k^HQ_k=I.\n$$\n\nWe then measured\n\n$$\n\\widehat\\alpha_k^{\\mathrm{tan}} = \\sigma_{\\min}(AQ_k).\n\\tag{6}\n$$\n\nBecause\n\n$$\n\\sigma_{\\min}(AQ_k) = \\min_{\\|c\\|_2=1}\\||AQ_kc\\||_2,\n$$\n\nLet $s_k$ denote the smallest singular value of $A Q_k$. for every sampled direction $q=Q_kc$,\n\n$$\n\\\\|Aq\\\\|_2\n\\\\geq\ns_k\\\\|q\\\\|_2.\n$$\n\nThus, $s_k$ measures the restricted gain over all linear combinations of the sampled local image directions, rather than testing each direction independently. \n\nAt each state, we sampled 32 local TD-DIP image directions using Jacobian–vector products and computed the singular values of the restricted operator $AQ$. The results are presented in **Table 2**.\n\nTable 2: Restricted conditioning of local TD-DIP image secants\n\n| AF | Stage | sigma_min(AQ) [IQR] | Condition number [IQR] |\n| ---- | ----- | -------------------: | ---------------------: |\n| 12x | Early | 0.282 [0.204, 0.300] | 1.28 [1.21, 1.75] |\n| 12x | Mid | 0.261 [0.158, 0.290] | 1.41 [1.26, 2.38] |\n| 12x | Late | 0.259 [0.130, 0.285] | 1.41 [1.27, 3.21] |\n| 24x | Early | 0.207 [0.162, 0.221] | 1.33 [1.25, 1.67] |\n| 24x | Mid | 0.191 [0.112, 0.212] | 1.52 [1.34, 2.68] |\n| 24x | Late | 0.190 [0.098, 0.214] | 1.51 [1.34, 3.26] |\n\nThe results show that all sampled valid directions exhibit positive restricted gain, and no valid directions were discarded. These findings support the validity of the local restricted-conditioning condition regarding the actual reconstructed trajectories. We will revise the manuscript to avoid describing this property as strong convexity over the full parameter space and will adjust the associated conclusions accordingly.\n\n### **On Q2:**\n---\nWe agree that the theory does not provide an unconditional guarantee of higher PSNR, clinical quality, or global convergence. Instead, it gives a conditional local recovery bound. For\n\n$$\ny=Ax_0+\\eta,\n$$\n\nassume local stability on the TD-DIP image set:\n\n$$\n\\||A(u-v)\\||_2\\geq\\alpha_k\\||u-v\\||_2,\\quad u,v\\in M_k.\n$$\n\nThen\n\n$$\n\\||\\widehat{x}_k-x_0\\||_2\\lesssim e_M+\\frac{r_M+\\sqrt{\\mu_k}e_a+\\sqrt{\\delta_k}}{\\alpha_k},\n$$\n\nwhere the terms denote representation, measurement, anchor, and optimization errors. Thus, the theory explains when recovery is stable, but does not guarantee superiority over every baseline."+ },+ "createdAt": "2026-07-28T11:43:28.707Z",+ "modifiedAt": "2026-11-18T17:11:24.021Z",+ "url": "https://openreview.net/forum?id=UbC0NrVCfU¬eId=xdUxqxrPwA",+ "license": "CC-BY-4.0"+}
reviews/openreview/ubc0nrvcfu/submission.json added
+++ b/reviews/openreview/ubc0nrvcfu/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "UbC0NrVCfU",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 3964,+ "url": "https://openreview.net/forum?id=UbC0NrVCfU",+ "license": "CC-BY-4.0"+}
versions/v_buhvh7id.json added
+++ b/versions/v_buhvh7id.json@@ -0,0 +1,22 @@+{+ "date": "2026-04-22",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 3964,+ "url": "https://openreview.net/forum?id=UbC0NrVCfU",+ "reviews": "openreview/ubc0nrvcfu",+ "evidence": [+ "https://openreview.net/forum?id=UbC0NrVCfU"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=UbC0NrVCfU",+ "evidence": [+ "https://openreview.net/forum?id=UbC0NrVCfU"+ ]+}