potentialpaper

Prior as Geometry, Not Generator: Weak-Diffusion Test-Time Reconstruction for Dynamic MRI

Update NeurIPS 2026 submission UbC0NrVCfU: 6 notes

@openreview[bot] · 2026-11-24 15:51 UTC · 28f222c6d97d ·

Evidence

reviews/openreview/ubc0nrvcfu/notes/1lwwyif8ba.json modified

+++ b/reviews/openreview/ubc0nrvcfu/notes/1lwwyif8ba.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair kVhH",
"content": {
- "metareview": "This manuscript suggests a method for MR reconstruction with the classical understampled k-space case, but in the Dynamic MRI collection setting, where ground truth k-space is very difficult to collect. It establishes a learned prior, to be used in place of the (inaccessible) true fully sampled data.\n\nAll reviewers found it hard to connect theory results to any guarantee of performance, and several reviewers found the results lackluster. In my opinion, authors should attempt to reconcile these views (or clarify any misconceptions about the theory, e.g., that they \"follow directly from definitions\") in the Rebuttal.\n\nMultiple reviewers offer complaints about baselines. I think it is reasonable to skip baselines given justification, or comparison to a superseding baseline, but those justifications should be made. \n\nMRI is clinically a visual and qualitative modality (at least for most contrasts). Following up on `mdsH`'s line of questions about visual differences would be beneficial to the manuscript.\n\nI tend to agree that this can get \"over the bar\", but I think that theory connections and questions need to be resolved before moving forward."
+ "metareview": "This manuscript suggests a method for MR reconstruction with the classical understampled k-space case, but in the Dynamic MRI collection setting, where ground truth k-space is very difficult to collect. It establishes a learned prior, to be used in place of the (inaccessible) true fully sampled data.\n\nAll reviewers found it hard to connect theory results to any guarantee of performance, and several reviewers found the results lackluster. In my opinion, authors should attempt to reconcile these views (or clarify any misconceptions about the theory, e.g., that they \"follow directly from definitions\") in the Rebuttal.\n\nMultiple reviewers offer complaints about baselines. I think it is reasonable to skip baselines given justification, or comparison to a superseding baseline, but those justifications should be made. \n\nMRI is clinically a visual and qualitative modality (at least for most contrasts). Following up on `mdsH`'s line of questions about visual differences would be beneficial to the manuscript.\n\nI tend to agree that this can get \"over the bar\", but I think that theory connections and questions need to be resolved before moving forward.",
+ "final_justification": "I find that the responses in rebuttal have adequately answered questions posed by reviewers, and in particular the ones I directed them towards.\n\nI am going to upweight `mdsH`'s assessment that this should be published, and down weight there category assessment; the results presented in this paper (both empirical and theoretical) may be fairly specific to MRI currently, but may have indirect relevance to other signal processing/imaging applications, or more broadly learned \"reconstruction\"."
},
"createdAt": "2026-07-21T20:51:22.950Z",
- "modifiedAt": "2026-11-18T15:18:51.015Z",
+ "modifiedAt": "2026-11-19T04:59:19.902Z",
"url": "https://openreview.net/forum?id=UbC0NrVCfU&noteId=1LWwyIf8bA",
"license": "CC-BY-4.0"
}

reviews/openreview/ubc0nrvcfu/notes/7k6ryyps9b.json added

+++ b/reviews/openreview/ubc0nrvcfu/notes/7k6ryyps9b.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "7K6rYYps9b",
+ "replyTo": "1LWwyIf8bA",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank the Area Chair for identifying three crucial issues in the manuscript: the connection between the theoretical analysis and empirical reconstruction performance, the adequacy of the baseline comparisons, and the need for visual evaluation.\n\nWhile keeping the reconstruction algorithm unchanged, we have significantly clarified and strengthened the theoretical formulation. We now define TD-DIP more precisely as a scan-specific parameterized image set, rather than an explicit Bayesian prior and clarify that our analysis provides conditional local recovery and perturbation bounds rather than unconditional performance guarantees.\n\nFor Assumption 3.2, we replace the curvature condition in the original parameter space with a local restricted condition in the image space that is independent of network parameterization, and we derive a direct bound on the conditional reconstruction error. JVP-based restricted-spectrum experiments provide empirical support for the tangent-space form of this condition on sampled local subspaces encountered along actual reconstruction trajectories.\n\nFor Assumption 3.4, we interpret the denoiser Jacobian as a local prior-sensitivity operator rather than an exact tangent projector. Under this more general formulation, the main mismatch result remains valid and shows that the gating parameter explicitly controls the dependence of the gated correction on diffusion-operator mismatch.\n\nTo address the issue of visual assessment, we conducted an additional blinded exploratory reader study: two radiologists independently evaluated seven anonymized methods across five randomly selected VISTA 24× cases, assessing overall image quality, structural-detail preservation, temporal consistency, and artifact suppression. Our method achieved the highest mean scores across all four dimensions, with differences between methods reaching statistical significance ( $p$ < 0.001) according to the Friedman test. We explicitly characterize this as a small-scale exploratory study rather than evidence of diagnostic or clinical superiority.\n\nWe have also strengthened our baseline evaluation. In addition to the original methods, we included a stronger supervised unrolled baseline, PromptMR+, evaluating both the released checkpoint and a version fine-tuned on the same cardiac cine training distribution. Furthermore, we incorporated DDIP-2D and D3IP-Time to enable a more direct comparison between frozen-diffusion guidance and diffusion-parameter adaptation. We wish to clarify that these DDIP experiments assess the direct transfer of existing static or volumetric adaptation strategies to cardiac cine MRI, rather than questioning the effectiveness of DDIP in its original tasks.\n\nIn addition, we have included experiments on runtime, memory, and reduced steps to demonstrate the trade-off between reconstruction quality and computational cost.\n\nIn summary, these modifications not only redefine the precise scope of the theoretical results but also establish a clearer link between the theoretical mechanisms and actual reconstruction performance through restricted-spectrum testing, mismatch analysis, matched ablation studies, stronger baselines, and radiologist evaluations. We believe these additions directly address the decision-critical concerns raised in the meta-review and render the manuscript’s contributions, evidence, and scope of applicability more accurate and comprehensive."
+ },
+ "createdAt": "2026-07-29T08:04:58.054Z",
+ "modifiedAt": "2026-11-19T17:01:24.676Z",
+ "url": "https://openreview.net/forum?id=UbC0NrVCfU&noteId=7K6rYYps9b",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ubc0nrvcfu/notes/f52ab05y14.json added

+++ b/reviews/openreview/ubc0nrvcfu/notes/f52ab05y14.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "f52Ab05y14",
+ "replyTo": "u7iHUxvtGN",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely appreciate your constructive and positive feedback. We are especially grateful for your recognition of the radiologist scoring experiment and of our clarification and empirical validation of Assumption 3.2. Your comments have greatly helped us improve the manuscript. \n\nWe also appreciate your candid concern that DIP remains somewhat of a black box and is difficult to interpret. In future work, we will explore more interpretable methods and develop a more comprehensive and clinically relevant evaluation framework."
+ },
+ "createdAt": "2026-07-29T03:38:33.323Z",
+ "modifiedAt": "2026-11-19T17:01:24.884Z",
+ "url": "https://openreview.net/forum?id=UbC0NrVCfU&noteId=f52Ab05y14",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ubc0nrvcfu/notes/iu78pineec.json added

+++ b/reviews/openreview/ubc0nrvcfu/notes/iu78pineec.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "iu78pinEec",
+ "replyTo": "tF642qDcfc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer Thc9",
+ "content": {
+ "comment": "I appreciate that the authors revised the theoretical framing and added empirical diagnostics. However, I still find the theory only partially informative. The revised formulation is more defensible, but it also substantially weakens the original geometric claim: the denoiser Jacobian is now treated as a prior-sensitivity operator rather than a tangent projector, and the guarantees are explicitly conditional local perturbation bounds rather than performance guarantees. The restricted-spectrum experiment is useful, but it only probes sampled local directions along successful reconstruction trajectories and does not establish that the TD-DIP image set generally avoids measurement-null directions or that the condition predicts reconstruction success. This feels like a substantial change to the original submission, rather than a minor revision.\n\nSimilarly, the gating analysis still appears largely algebraic: increasing $\\lambda$ reduces dependence on the diffusion sensitivity operator by construction, but this does not explain when the prior-residual component corresponds to useful subject-specific signal rather than aliasing or noise."
+ },
+ "createdAt": "2026-08-04T01:14:47.906Z",
+ "modifiedAt": "2026-11-19T17:01:24.574Z",
+ "url": "https://openreview.net/forum?id=UbC0NrVCfU&noteId=iu78pinEec",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ubc0nrvcfu/notes/prhdndpjsy.json added

+++ b/reviews/openreview/ubc0nrvcfu/notes/prhdndpjsy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PRHDNDPjsy",
+ "replyTo": "iu78pinEec",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the careful follow-up. We agree that the revised theory is deliberately narrower than the geometric interpretation in the submitted manuscript. This revision does not change the reconstruction objective, TD-DIP optimization, Jacobian–vector computation, adaptive gate, or any part of the implemented algorithm. It removes assumptions that were stronger than required and limits the claims to the operator-level properties that can be established rigorously.\n\nWe also agree that the restricted-spectrum experiment does not prove global injectivity over the entire TD-DIP image set or provide a standalone predictor of reconstruction success. However, neither property is required by the revised result, which assumes only local restricted conditioning near the Stage-B solution. The diagnostic therefore examines the relevant local directions encountered along actual reconstruction trajectories. We evaluated multiple cases at VISTA 12× and 24×, across early, middle, and late stages, without selecting only favorable states. The consistently positive restricted gains support the non-degeneracy of the sampled local subspaces, while the lower gains at 24× are consistent with weaker conditioning under more severe undersampling. We will state this strictly as trajectory-local empirical support, not as a global guarantee or success predictor.\n\nRegarding the gate, we agree that the mismatch inequality does not prove that every prior-residual correction is useful. Its role is narrower: it quantifies how $λ$ controls sensitivity to disagreement in the diffusion operator. We will therefore replace “useful subject-specific signal” with “candidate scan-specific innovation.” This correction is produced by the measurement-consistent, temporally parameterized Stage-B TD-DIP solution, but it may still contain aliasing or noise; this is why it is adaptively and conservatively gated rather than fully injected.\n\nWhether the proposed geometric correction is empirically beneficial is addressed by the matched ablation rather than by the algebraic bound. Under VISTA 12×, TD-DIP alone achieves 41.45 dB. Combining diffusion and TD-DIP yields 43.92 dB with naive MCG coupling and 45.05 dB without the proposed projection strategy, while the full geometric strategy achieves 45.77 dB and the highest SSIM. Thus, the ablation distinguishes the general benefit of combining diffusion and TD-DIP from the additional contribution of geometric control: our strategy improves PSNR by 1.85 dB over naive MCG coupling and by 0.72 dB over the matched hybrid without geometric projection.\n\nWe acknowledge that the theoretical interpretation has been substantially refined. However, the method itself has not been replaced or modified; the revision calibrates the claims to the actual algorithm and evidence."
+ },
+ "createdAt": "2026-08-04T01:57:08.964Z",
+ "modifiedAt": "2026-11-19T17:01:24.580Z",
+ "url": "https://openreview.net/forum?id=UbC0NrVCfU&noteId=PRHDNDPjsy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ubc0nrvcfu/notes/u7ihuxvtgn.json added

+++ b/reviews/openreview/ubc0nrvcfu/notes/u7ihuxvtgn.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "u7iHUxvtGN",
+ "replyTo": "xdUxqxrPwA",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer mdsH",
+ "content": {
+ "title": "Reply to rebuttal",
+ "comment": "This is a very responsive rebuttal to my review, and I have skimmed the other reviews and the other rebuttals also look responsive to me. The addition of the radiologist score study is very valuable and shows significant benefits. The review process should reward papers that go to those lengths (and should discourage papers that just report PSNR values). The additional clarification about Assumption 3.2 and the associated empirical evidence is also a strong addition.\n\nI intend to improve my scores.\nI still won't go to the highest scores because DIP feels like a black box ad hoc method to me, but I recognize that we lack training data for learning a good temporal prior, so the proposed approach seems like a very reasonable option at this point in time and the empirical comparisons are convincing enough."
+ },
+ "createdAt": "2026-07-29T00:32:08.848Z",
+ "modifiedAt": "2026-11-19T17:01:25.013Z",
+ "url": "https://openreview.net/forum?id=UbC0NrVCfU&noteId=u7iHUxvtGN",
+ "license": "CC-BY-4.0"
+}