Prior as Geometry, Not Generator: Weak-Diffusion Test-Time Reconstruction for Dynamic MRI
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:35 UTC · 4ef4596ef82c ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,26 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "UbC0NrVCfU"- }- ],- "title": "Prior as Geometry, Not Generator: Weak-Diffusion Test-Time Reconstruction for Dynamic MRI",- "authors": [- "Mengzhe Du",- "Congcong Liu",- "Baoqing Li",- "Jinglong Tao",- "Wenwu He",- "Zhuo-Xu Cui"- ],- "abstract": "Dynamic MRI reconstruction from highly undersampled $k$-space is an ill-posed inverse problem that requires strong measurement consistency, fine spatial and temporal recovery.\nDiffusion priors provide useful population-level regularization, but task-matched spatiotemporal diffusion models are costly to train, while generic pretrained priors may be mismatched to protocols, vendors, or anatomies, causing hallucination or over-smoothing.\nUntrained test-time priors like Time-Dependent Deep Image Prior (TD-DIP) adapt to each scan and naturally couple with data consistency, but can drift toward aliasing artifacts and overfit noise.\nWe propose Geometry-Gated TD-DIP for this weak-diffusion regime, where diffusion is used primarily as a local geometric reference rather than an unconstrained generative prior.\nEach TD-DIP correction is split by the diffusion denoiser's Jacobian into a prior-sensitive component and a prior-residual component.\nA self-calibrated gate regulates the residual contribution to balance scan-specific recovery against prior mismatch and noise amplification.\nWe establish conditional reconstruction error bounds and characterize the effects of geometric gating and diffusion-prior mismatch on reconstruction fidelity.\nExperiments on cine MRI show consistent gains over diffusion-only, TD-DIP-only, and additive hybrid baselines, especially at high acceleration and under out-of-distribution diffusion priors. The code is publicly available at: https://github.com/MAiTL-Group/weak-diffusion-mri.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "c15ac7ce-5830-4904-98b2-96a5b904988b"}
paper.json added
+++ b/paper.json@@ -0,0 +1,16 @@+{+ "title": "Prior as Geometry, Not Generator: Weak-Diffusion Test-Time Reconstruction for Dynamic MRI",+ "authors": [+ "Mengzhe Du",+ "Congcong Liu",+ "Baoqing Li",+ "Jinglong Tao",+ "Wenwu He",+ "Zhuo-Xu Cui"+ ],+ "abstract": "Dynamic MRI reconstruction from highly undersampled $k$-space is an ill-posed inverse problem that requires strong measurement consistency, fine spatial and temporal recovery.\nDiffusion priors provide useful population-level regularization, but task-matched spatiotemporal diffusion models are costly to train, while generic pretrained priors may be mismatched to protocols, vendors, or anatomies, causing hallucination or over-smoothing.\nUntrained test-time priors like Time-Dependent Deep Image Prior (TD-DIP) adapt to each scan and naturally couple with data consistency, but can drift toward aliasing artifacts and overfit noise.\nWe propose Geometry-Gated TD-DIP for this weak-diffusion regime, where diffusion is used primarily as a local geometric reference rather than an unconstrained generative prior.\nEach TD-DIP correction is split by the diffusion denoiser's Jacobian into a prior-sensitive component and a prior-residual component.\nA self-calibrated gate regulates the residual contribution to balance scan-specific recovery against prior mismatch and noise amplification.\nWe establish conditional reconstruction error bounds and characterize the effects of geometric gating and diffusion-prior mismatch on reconstruction fidelity.\nExperiments on cine MRI show consistent gains over diffusion-only, TD-DIP-only, and additive hybrid baselines, especially at high acceleration and under out-of-distribution diffusion priors. The code is publicly available at: https://github.com/MAiTL-Group/weak-diffusion-mri.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}