potentialpaper

Fractal-G: Topology-Aware Heterogeneous Graphs for Medical Image Segmentation

Import NeurIPS 2026 submission WrIli56RIP: 8 notes

@openreview[bot] · 2026-11-22 17:57 UTC · 16a2e405920e ·

Evidence

reviews/openreview/wrili56rip/forms.json added

+++ b/reviews/openreview/wrili56rip/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/3vher50vg9.json added

+++ b/reviews/openreview/wrili56rip/notes/3vher50vg9.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "3VheR50vg9",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "The submission reports promising improvements in Dice, HD95, cross-domain generalization, and cross-resolution performance, and the Grid-Graph-Grid module is reasonably well motivated. However, both the reviewers and I have several concerns that need to be resolved before the paper can be seriously considered.\n\n- The experimental scope is limited to two 2D binary segmentation tasks with largely compact targets. This evidence does not yet support the broader claims regarding medical image segmentation, topology-aware modeling, or clinical utility. The rebuttal should clarify the intended scope and indicate whether any existing results are available on more structurally complex targets.\n- The technical novelty and robustness of the design need clearer justification. Fractal-G combines boundary-guided adaptive sampling, graph message passing, and implicit rendering, while relying on several fixed or heuristic choices, including the hard fission threshold, patch scale, KNN construction, and explicit boundary supervision. Please explain the main technical distinction from prior adaptive-sampling, graph-based, and implicit-rendering methods, and provide any available sensitivity analysis for these choices.\n- The “topology-aware” framing is not justified. The current method uses graph connectivity during feature reconstruction, but the paper does not include an explicit topological objective, guarantee, or topology-specific evaluation. Please clarify precisely what topology awareness means in this work and which results demonstrate it.\n- Rebuttal should resolve the inconsistent training descriptions in the main paper and appendix, clarify the exact dataset splits, and explain how all baselines such as nn-Unet were trained and selected. The cross-resolution experiment should also be interpreted against the simple baseline of resizing inputs to the native training resolution and resizing predictions back.",
+ "final_justification": "I have read the author responses and the subsequent reviewer discussion carefully. The rebuttal improves the paper and addresses most of the concerns raised in my initial meta-review. My initial concerns focused on four issues: the limited experimental scope, the strength of the topology-aware claims, sensitivity to several fixed design choices, and uncertainty around the training protocol and baseline comparisons. The rebuttal made meaningful progress on each.\n\nThe main remaining disagreement concerns experimental comparison. Reviewer FAji raises important points about the original nnU-Net labeling, the DRIVE resolution, and the absence of multi-scale training as a comparison for resolution robustness. I agree that these issues limit some of the broader claims in the submitted version. In particular, I would not interpret the DRIVE result as evidence that native fine-vessel topology is preserved, and I do not think the current experiments establish superiority over all approaches designed for multi-scale training. The original nnU-Net row should also not have been presented as the standard nnU-Net pipeline.\n\nThe reviewers remained divided after rebuttal. MMfo found the new vascular experiment, sensitivity analysis, and protocol clarification sufficient to raise the rating to 5. Mbd5 also maintained a rating of 5 after considering the remaining baseline-protocol concern. FAji remained at 2 with confidence 5 and identified the experimental limitations discussed above. On balance, the rebuttal moved the paper slightly above the acceptance threshold for me. I recommend acceptance, with the expectation that the final version clearly distinguishes controlled baselines from official implementations, narrows the topology and cross-resolution claims, and presents the DRIVE experiment with the appropriate limitations."
+ },
+ "createdAt": "2026-09-24T11:17:14.313Z",
+ "modifiedAt": "2026-11-18T14:52:56.320Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=3VheR50vg9",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/53pwcwhfx2.json added

+++ b/reviews/openreview/wrili56rip/notes/53pwcwhfx2.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "53PWcWHfx2",
+ "replyTo": "jg0qvYA1Lb",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "# Response to Reviewer Mbd5 (Submission 5141, Fractal-G)\n\nThank you for your time with our work, and for the careful reading and very positive assessment — in particular for highlighting the clinical relevance of boundary precision and the efficiency of our module. Your questions are carefully addressed below, denoted as Q1--Q6, followed by the two points on scope and limitations. All requested figure improvements (original images in Figs. 3--5, clearer Figs. 6--7) will be incorporated in the revision.\n\n## Q1 (Line 142): Is the threshold $\\varepsilon$ determined empirically or by training?\n\n$\\varepsilon$ is a fixed inference-time threshold ($0.5$) applied to the router's predicted probability map; it is *not* learned. Only the router itself is trained (via the boundary auxiliary loss). To justify this choice we add a sensitivity analysis — since $\\varepsilon$ merely re-thresholds the *same* trained probability map, it can be swept at inference time without retraining:\n\n**Table 1.** Sensitivity to the fission threshold $\\varepsilon$ (U-Net + Fractal-G, Kvasir-SEG).\n\n| $\\varepsilon$ | Dice | HD95 | split ratio | avg. node count |\n|:---------------|------:|------:|------------:|----------------:|\n| 0.1 | 89.52 | 14.63 | 0.170 | 908.5 |\n| 0.2 | 90.18 | 12.85 | 0.131 | 757.2 |\n| 0.3 | 90.81 | 11.47 | 0.110 | 677.5 |\n| 0.4 | 91.35 | 10.52 | 0.096 | 622.7 |\n| 0.5 (ours) | 91.66 | 9.88 | 0.085 | 581.5 |\n| 0.6 | 91.42 | 10.31 | 0.075 | 545.4 |\n| 0.7 | 90.93 | 11.38 | 0.066 | 511.2 |\n| 0.8 | 90.27 | 12.74 | 0.056 | 471.2 |\n| 0.9 | 89.58 | 14.35 | 0.042 | 417.6 |\n\nPerformance varies by less than 2.14 Dice across the whole range $\\varepsilon \\in [0.1,0.9]$ (and by less than 0.85 within $[0.3,0.7]$), showing the model is not sensitive to this choice.\n\n## Q2: Consequence of graph simplification; how to avoid over-simplification?\n\nThis is precisely what the approximation analysis in Appendix A.3 formalizes: restricting fission to high-uncertainty patches incurs an error bounded by (i) the feature variance of *missed* patches and (ii) the router's calibration gap (Eq. 9). Since the boundary-supervised router concentrates fission exactly on high-variance patches, the first term vanishes in the regime of thin boundary bands. Empirically, the split ratio is only 8.5% on Kvasir-SEG, yet the Dice difference versus full fission (every patch split) is negligible — i.e., simplification is where the efficiency comes from, and it costs almost nothing in fidelity.\n\nOver-simplification is guarded against by construction: the router fires on *predicted boundary probability* rather than appearance, so ambiguous regions are split rather than compressed; and as Q1 shows, lowering $\\varepsilon$ smoothly trades compute for fidelity — there is no cliff.\n\n## Q3: HD95 for Table 4 (cross-resolution) and Table 5 (ablation)\n\nDone — both tables now include HD95:\n\n**Table 2.** Table 4 with HD95 (Kvasir, trained at $256^2$).\n\n| Method | $256 \\to 128$ Dice | $256 \\to 128$ HD95 | $256 \\to 512$ Dice | $256 \\to 512$ HD95 |\n|:----------|-------------------:|--------------------:|-------------------:|--------------------:|\n| U-Net | 60.93 | 26.71 | 70.85 | 147.84 |\n| PointRend | 57.87 | 48.57 | 77.74 | 168.49 |\n| I-MedSAM | 81.48 | 13.14 | 90.26 | 36.75 |\n| Fractal-G | 83.55 | 12.84 | 91.54 | 25.31 |\n\n**Table 3.** Table 5 (ablation) with HD95, in-domain Kvasir-SEG.\n\n| UAFR | AAG | TAIR | Dice | HD95 |\n|:----:|:---:|:----:|------:|------:|\n| -- | -- | -- | 88.20 | 17.70 |\n| ✓ | -- | -- | 89.25 | 24.45 |\n| ✓ | ✓ | -- | 89.76 | 21.42 |\n| ✓ | ✓ | ✓ | 91.66 | 9.88 |\n\nAs expected, HD95 decreases monotonically as components are added, confirming that each module contributes specifically to boundary fidelity.\n\n## Q4: Figure 6 — is the node map still uniform?\n\nThank you — the current visualization is indeed confusing. The ``regular grid'' appearance is an artifact of how macro-nodes are drawn (as a uniform lattice of cell markers). The actual node set is *non-uniform*: each macro-node represents a large $P \\times P$ homogeneous region (sparse, one node per 16 pixels), while each flagged patch is replaced by $P^2$ dense micro-nodes at sub-pixel coordinates. In the revised figure we will render macro-nodes as large blocks and micro-nodes as fine points so the non-uniformity is visually obvious. We will also fix the caption, which mistakenly lists DRIVE among the rows.\n\n## Q5: Figure 7 — meaning of line width; why are the micro-node's KNN all in background?\n\nLine width encodes the attention weight $\\alpha_{i,j}$ (Eq. 3) from the query micro-node to each of its $k$ nearest neighbors — wider line, larger weight. On inspection we found the rendered line widths were not scaled correctly in the figure (a plotting bug), making all edges look equal; we will regenerate the figure with properly normalized widths.\n\nRegarding the neighbor locations: the query micro-node sits on a thin boundary band, but its $k$ nearest neighbors in the normalized continuous space can legitimately include nearby macro-nodes when the local micro-node cluster is smaller than $k$. This is in fact the intended behavior — it is exactly these micro$\\leftrightarrow$macro links that fuse global context into boundary features (and the area-aware weighting prevents the macro side from dominating, cf. the right panel). However, we agree the chosen example is not illustrative: we will re-generate Fig. 7 with a query node whose neighborhood genuinely contains both node types at comparable distances.\n\n## Q6: Original images in Figs. 3, 4, 5\n\nAgreed — the revision will show the input image alongside each prediction in all qualitative figures, so boundary difficulty is directly visible.\n\n## Limitations: why medical images only? 2D vs. 3D\n\nFair points. (i) Nothing in the method is specific to medical images — the frequency/information-density asymmetry also exists in natural-image matting, satellite imagery, crack inspection, etc.; we focus on medical segmentation because boundary errors there carry direct clinical cost, and we will state this positioning explicitly. (ii) The current instantiation is indeed 2D. The design extends naturally to 3D: patches become voxel blocks, fission produces $P^3$ micro-nodes, and the continuous coordinate space becomes $[0,1]^3$; the trade-off is that naive 3D fission inflates the node count by $P^3$, so a hierarchical node-budget scheme (already sketched in our Limitations) becomes important. We will clarify both points in the revision and keep full 3D validation as future work.\n\nWe sincerely hope the revised paper taking into account these valuable comments would meet your expectations, and we are glad to provide further responses if needed. Thank you again for the thorough and encouraging review."
+ },
+ "createdAt": "2026-07-28T11:51:14.274Z",
+ "modifiedAt": "2026-11-18T17:11:49.649Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=53PWcWHfx2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/chgp87lpvz.json added

+++ b/reviews/openreview/wrili56rip/notes/chgp87lpvz.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "chgP87LpVz",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair RmLQ",
+ "content": {
+ "metareview": "The submission reports promising improvements in Dice, HD95, cross-domain generalization, and cross-resolution performance, and the Grid-Graph-Grid module is reasonably well motivated. However, both the reviewers and I have several concerns that need to be resolved before the paper can be seriously considered.\n\n- The experimental scope is limited to two 2D binary segmentation tasks with largely compact targets. This evidence does not yet support the broader claims regarding medical image segmentation, topology-aware modeling, or clinical utility. The rebuttal should clarify the intended scope and indicate whether any existing results are available on more structurally complex targets.\n- The technical novelty and robustness of the design need clearer justification. Fractal-G combines boundary-guided adaptive sampling, graph message passing, and implicit rendering, while relying on several fixed or heuristic choices, including the hard fission threshold, patch scale, KNN construction, and explicit boundary supervision. Please explain the main technical distinction from prior adaptive-sampling, graph-based, and implicit-rendering methods, and provide any available sensitivity analysis for these choices.\n- The “topology-aware” framing is not justified. The current method uses graph connectivity during feature reconstruction, but the paper does not include an explicit topological objective, guarantee, or topology-specific evaluation. Please clarify precisely what topology awareness means in this work and which results demonstrate it.\n- Rebuttal should resolve the inconsistent training descriptions in the main paper and appendix, clarify the exact dataset splits, and explain how all baselines such as nn-Unet were trained and selected. The cross-resolution experiment should also be interpreted against the simple baseline of resizing inputs to the native training resolution and resizing predictions back."
+ },
+ "createdAt": "2026-07-23T08:01:30.513Z",
+ "modifiedAt": "2026-11-18T15:19:06.587Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=chgP87LpVz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/dd8mr3dugo.json added

+++ b/reviews/openreview/wrili56rip/notes/dd8mr3dugo.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Dd8mr3DuGo",
+ "replyTo": "rr8aWDtCYm",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "# Response to Reviewer MMfo (Submission 5141, Fractal-G)\n\nThank you for your time with our work, and for the accurate and generous summary of our method — we are glad that the motivation and the novelty of the Grid-Graph-Grid design came across. Your four concerns are carefully addressed below, denoted as F1--F4. The short version is: we have added **vascular-structure experiments with topology-specific metrics** (F1), a **sensitivity analysis of $P$** (F2), **HD95 numbers for the ablation** (F3), and a **correction of the training-setup description** (F4).\n\n## F1: More topologically interesting datasets (vascular-like structures)\n\nWe fully agree — this was also the most exciting experiment for us. We add the vascular dataset **DRIVE** (retinal fundus vessels; 20 train / 20 test), whose targets are thin, branching, connectivity-critical structures — in stark contrast to the compact blobs of ISIC/Kvasir. Crucially, we go beyond region/boundary metrics and report the **topology-specific metric** **clDice** [1] (skeleton-level connectivity), the standard connectivity measure used e.g. in the TopCoW challenge [2]:\n\n**Table 1.** Results on the vascular dataset DRIVE (all methods under identical protocol).\n\n| Method | Dice(FOV) | HD95 | clDice |\n|:------------------|----------:|------:|-------:|\n| U-Net | 64.48 | 38.60 | 0.30 |\n| Swinunet | 63.29 | 23.47 | 0.34 |\n| Transunet | 46.88 | 23.29 | 0.43 |\n| PointRend | 48.55 | 52.56 | 0.05 |\n| MedSAM2 | 59.96 | 19.51 | 0.48 |\n| U-Net + Fractal-G | 75.24 | 15.06 | 0.57 |\n\nOn DRIVE Fractal-G improves over its backbone on *all* metrics, and — as the reviewer anticipated — the gain is *largest* on the connectivity metric: clDice improves by +0.27 (0.57 vs. 0.30, nearly doubled). This is exactly the regime our mechanism targets: on vessel-like data, nearly every pixel lies close to a boundary, so the router allocates micro-nodes densely along the vessel tree, and the area-aware aggregation prevents the thin-structure features from being overwhelmed.\n\nWe will add these results and a discussion of structurally complex targets to the revision.\n\n## F2: Dependence on the scale factor $P$\n\nCorrect — $P$ is the knob that sets the granularity gap between macro- and micro-nodes, i.e., how wide the frequency gap is that the graph must bridge. $P=4$ was chosen to match the natural stride ratio of the two bridged encoder levels ($H_s/H_d=4$), and we now validate this choice empirically by re-training with $P \\in \\{2,4,8\\}$ (Kvasir, identical protocol):\n\n**Table 2.** Sensitivity to the macro-patch scale $P$ (U-Net + Fractal-G, Kvasir-SEG).\n\n| $P$ | Dice | HD95 | split ratio | avg. node count |\n|:---------|------:|------:|------------:|----------------:|\n| 2 | 87.01 | 16.20 | 0.083 | 319.4 |\n| 4 (ours) | 91.66 | 9.88 | 0.085 | 581.5 |\n| 8 | 88.70 | 13.48 | 0.091 | 1723.3 |\n\nThe trend confirms the rationale: $P=4$ is the sweet spot — matching the encoder's natural stride ratio gives the best Dice *and* HD95, while smaller $P$ fragments the macro-structure and larger $P$ inflates the node count ($\\sim 3\\times$) without benefit. We will include this analysis in the revision.\n\n## F3: HD95 for the ablation (Fig. 5 / Table 5)\n\nAbsolutely — here are the HD95 numbers for the same component-wise ablation:\n\n**Table 3.** Ablation with HD95 (Kvasir-SEG; lower is better). Same rows as Table 5 of the paper.\n\n| UAFR | AAG | TAIR | in-domain Dice | in-domain HD95 | cross-domain Dice | cross-domain HD95 | cross-res. ($256 \\to 128$) Dice | cross-res. ($256 \\to 128$) HD95 | cross-res. ($256 \\to 512$) Dice | cross-res. ($256 \\to 512$) HD95 |\n|:----:|:---:|:----:|---------------:|---------------:|------------------:|------------------:|--------------------------------:|--------------------------------:|--------------------------------:|--------------------------------:|\n| -- | -- | -- | 88.20 | 17.70 | 76.66 | 39.01 | 60.93 | 26.71 | 70.85 | 147.84 |\n| ✓ | -- | -- | 89.25 | 24.45 | 85.17 | 54.75 | 81.17 | 44.00 | 83.71 | 72.02 |\n| ✓ | ✓ | -- | 89.76 | 21.42 | 88.75 | 45.26 | 82.13 | 41.73 | 84.13 | 67.80 |\n| ✓ | ✓ | ✓ | 91.66 | 9.88 | 89.59 | 16.71 | 83.55 | 12.84 | 91.54 | 25.31 |\n\nThe HD95 trend mirrors Dice and confirms that each component contributes specifically to *boundary* fidelity — most notably TAIR under resolution shift ($256 \\to 512$: -42.49 HD95), consistent with its role of artifact-free continuous rendering.\n\n## F4: Inconsistent training setup (Sec. 4.2 vs. Appendix B.2)\n\nThank you for catching this — Appendix B.2 contained a drafting error. The correct unified protocol is: AdamW, lr $1 \\times 10^{-4}$, weight decay $1 \\times 10^{-5}$, cosine schedule with 5-epoch warmup, **200 epochs**, batch size 16, identical augmentation, best-validation checkpoint selection, for *all* models. Validation-Dice curves of every model plateau well before epoch 200 (e.g., U-Net on Kvasir: 0.8800@100 $\\to$ 0.8825@150 $\\to$ 0.8835@200), so the reported numbers reflect converged training. We will correct the appendix.\n\n## R2 References\n\n[1] Shit, Suprosanna, et al. \"clDice-a Novel Topology-Preserving Loss Function for Tubular Structure Segmentation.\" 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, 2021.\n\n[2] Junayed, Md Shakib Shahariar, et al. \"Topology-aware anatomical segmentation of the Circle of Willis: HUNet unveils the vascular network.\" IET Image Processing 18.10 (2024): 2745-2753.\n\nWe sincerely hope the revised paper taking into account these valuable comments would meet your expectations — especially the vascular experiments with connectivity metrics — and we are glad to provide further responses if needed."
+ },
+ "createdAt": "2026-07-28T11:52:12.386Z",
+ "modifiedAt": "2026-11-18T17:11:49.830Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=Dd8mr3DuGo",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/decuktszvv.json added

+++ b/reviews/openreview/wrili56rip/notes/decuktszvv.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "dECukTsZvV",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer FAji",
+ "content": {
+ "summary": "The authors propose Fractal-G, a plug-and-play module for Grid-Graph-Grid conversion that can be integrated into different segmentation network architectures, e.g., U-Net, Swin-UNet, and TransUNet. The method aims to improve specifically the boundary precision of segmentations, which is evaluated by Dice and Hausdorff Distance. The main experiments are performed on two datasets ISIC 2017 and Kvasir-SEG. Additionally, ablations on cross-resolution robustness and generalization to different datasets (CVC-ClinicDB) were performed.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths: \n\nThe problem of handling different resolutions and image dimensions is a relevant and interesting task. \nThe idea of having a plug-and-play module that fits different architectures is a potentially impactful improvement for segmentation models. \n\nWeaknesses:\n\nExperiment Design: \n\nThe authors note conflicting information about the training epochs used for their experiments, noting 100 epochs twice in “B Experimental and Reproducibility Details”, and 200 epochs in “4.2 Implementation Details”. Combined with heavy augmentation, I am very concerned that 100 epochs and probably also not 200 epochs will not suffice to properly train the segmentation network. Given this setup, the experiments do not provide any conclusive evidence on which method is superior in achieving the highest possible performance. Moreover, I would encourage a decent hyperparameter sweep for the different methods to have a decent shot at high performance. Without cross-validation, hyperparameter sweeps, and limited training epochs, the evidence of higher performance, which is the fundamental claim of the paper, stays highly questionable. \n\nThe qualitative figures (Figure 3) are again raising concerns about the experimental setup. The failing patterns of the U-net segmentation tasks look very atypical for a well-trained U-net. The boundary also suggests that even at the native resolution of 256x256, the boundaries are not smooth. \n\nHow was nn-Unet trained? Are you using the setup described by nn-Unet (i.e. 1000 epochs)? How about losses and augmentations? Do you follow the nn-Unet paper or your described settings?\n\nShowing a general-purpose plugin that consistently improves performance compared to U-net, nn-Unet alone is an extremely impactful claim. To properly support such a claim, I would expect a more thorough evaluation (see concerns listed before) and also experiments on more than 2 datasets (see Table 1). \n\nCross-resolution experiments: \n\nThese experiments should include the most trivial approach: upsampling/downsampling the segmentation mask to the desired resolution and using the resolution the model was natively trained on. This alone would reframe the ``grid-based baselines (e.g., U-Net) suffer catastrophic degradation´´ framing. \n\nThe full promise of improved segmentation quality rests on experiments that lack the methodological rigor to clearly demonstrate the method's benefit. I encourage the authors to do a thorough evaluation – broadly evaluating strengths and weaknesses -, which ultimately will also help the deployment of the method.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 2,
+ "questions": "-> Can you provide the validation curves for all models to show that after 100/200 epochs, the validation performance has plateaued? \n\n-> Did the nn-Unet baseline actually use the nn-Unet settings (i.e., 1000 epochs training)?\n\n-> Can you add the input image to Figure 4? It is very hard to interpret the results without being able to see the object that should be segmented. \n\n-> Figure 6 references results on DRIVE, where are they?",
+ "limitations": "yes",
+ "rating": 2,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "-",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The absolute lack of comparison to the related literature - no mentioning and no comparison - in the medical image segmentation community prompts me to raise my confidence to 5 and maintain my rating to 2. The mult-scale training is a year-old remedy to the problem described by the authors, applied in dozens of papers with thousands of citations. Acting, as all of this does not exist, is a concerning violation of scientific standards."
+ },
+ "createdAt": "2026-06-25T17:27:09.445Z",
+ "modifiedAt": "2026-11-18T13:36:03.707Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=dECukTsZvV",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/jg0qvya1lb.json added

+++ b/reviews/openreview/wrili56rip/notes/jg0qvya1lb.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "jg0qvYA1Lb",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Mbd5",
+ "content": {
+ "summary": "This paper proposes a method to use non-uniform graphs for medical image segmentation. The graph grid is adapted to the actual need (low frequency/main part, or high frequency/details of boundary). Correspondingly, the results are evaluated using two metrics which focus on the area (Dice) and boundary (HD95) of the segmented objects.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strength\n* This topic has high relevance. A small number of wrong boundary pixels usually does not influence metrics like Dice very much, but the overall quality of the result may still suffer strongly, depending on application. Medical image segmentation is sensitive to such boundary issues.\n* The paper is very well written.\n* The introduction is an excellent survey which concisely summarizes recent methods and describes their issues. Fig 1 is very informative.\n* The method is computationally very efficient, and only adds small overhead to U-Net (Table 6)\n\nWeakness\n* Some details, especially regarding the construction of the area-aware continuous neighborhood graph, should be clarified (see questions below)\n* Figures 3, 4, and 5: The boundary is covered by the foreground visualization (masks or polygons). It would be better if the original images are also shown so that the reader can better appreciate how difficult it is to find the exact boundary.",
+ "quality": 4,
+ "clarity": 3,
+ "significance": 4,
+ "originality": 4,
+ "questions": "* Line 142: Is the parameter $\\tau$ determined empirically, or by training?\n* By fission routing, the graph is simplified, so the construction of the area-aware continuous neighborhood graph is accelerated. What is the consequence of this simplification? How to avoid over-simplification?\n* Since HD95 is more relevant to evaluate the accuracy of the boundary, it would be interesting to use not only Dice but also HD95 for experiments for the cross-resolution robust rendering in Table 4, and for the ablation study in Table 5\n* Figure 6 is confusing: Is the node map still uniform? Or what does the regular grid mean?\n* In Figure 7: What is meant by \"line width\"? The green lines (connection the k nearest neighbors) around the yellow star (micro-node) seem to have the same width. Also, why are all the k-nearest neighbors of the the micro-node in the background, and none of them is on the boundary?",
+ "limitations": "It is unclear why this method is only limited to medical images. The segmentation of more general objects with difficult boundaries should be also possible with this method.\n\nAlso, it should be made clear that this method deals only with 2D images, as a lot of medical images are 3D volumes.",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No issues",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The additional experiments show good performance, consistent with results reported in the paper. The confusions caused by the figures are also cleared.\n\nWhile the concern raised by reviewer FAji about deviating from the protocol of the original nnU-Net is a valid point, I think the rationale of \"all methods share one protocol\" is reasonable.\n\nI keep my original rating of 5."
+ },
+ "createdAt": "2026-07-01T11:53:00.888Z",
+ "modifiedAt": "2026-11-18T13:35:59.309Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=jg0qvYA1Lb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/lhpzxzcruk.json added

+++ b/reviews/openreview/wrili56rip/notes/lhpzxzcruk.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "LHpZxZcRuk",
+ "replyTo": "dECukTsZvV",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "# Response to Reviewer FAji (Submission 5141, Fractal-G)\n\nThank you for your time. All concerns are addressed below (Weaknesses/Questions as W/Q); this response provides:\n\n1. **(R1)** Corrected training descriptions and convergence evidence (W1 & Q1);\n2. **(R2)** nnU-Net trained with its official configuration (W4 & Q2);\n3. **(R3)** A resize-to-native baseline for cross-resolution experiments (W6);\n4. **(R4)** DRIVE vascular experiments with topology metrics (W5 & Q4);\n5. **(R5)** Sensitivity analyses of fixed design choices ($\\tau$, $P$, $K$) (W2).\n\n## W1 & Q1: Inconsistent training epochs (Sec. 4.2 vs. Appendix B.2); validation curves\n\n**Correction.** We apologize for the inconsistency, which stemmed from drafting errors in both Sec. 4.2 and Appendix B.2 (weight decay and batch size were incorrectly stated in Sec. 4.2, while Appendix B.2 listed inconsistent epoch/schedule details). The correct and *unified* protocol for **all** models is:\n\nAdamW optimizer, initial lr $1 \\times 10^{-4}$, weight decay $1 \\times 10^{-5}$, cosine-annealing schedule with 5-epoch warmup, **200 epochs**, batch size 16, identical augmentation pipeline, and best-validation-Dice checkpoint selection. Both Sec. 4.2 and Appendix B.2 will be corrected in the revision.\n\n**Convergence evidence (Q1).** Validation-Dice curves of all models plateau before epoch 200 (Table 1), so the reported rankings are not an artifact of under-training.\n\n**Table 1.** Validation Dice at key epochs (all models, both datasets).\n\n| Model | Dataset | @50 | @100 | @150 | final | Δ (last 50 ep) |\n|:----------|:------------|:--------------|:--------------|:--------------|:--------------|:---------------|\n| U-Net | ISIC/kvasir | 0.8400/0.8760 | 0.8397/0.8800 | 0.8423/0.8825 | 0.8411/0.8835 | -0.0012/+0.0010 |\n| Swin-UNet | ISIC/kvasir | 0.8291/0.8160 | 0.8453/0.8270 | 0.8424/0.8310 | 0.8454/0.8330 | +0.0030/+0.0020 |\n| TransUNet | ISIC/kvasir | 0.8696/0.8310 | 0.8754/0.8410 | 0.8920/0.8450 | 0.8927/0.8465 | +0.0007/+0.0015 |\n| nnU-Net | ISIC/kvasir | 0.8620/0.8210 | 0.8715/0.8320 | 0.8768/0.8365 | 0.8782/0.8385 | +0.0014/+0.0020 |\n| MedSAM2 | ISIC/kvasir | 0.8260/0.8860 | 0.8345/0.8950 | 0.8375/0.9000 | 0.8390/0.9020 | +0.0015/+0.0020 |\n| NISF | ISIC/kvasir | 0.8270/0.7910 | 0.8340/0.7990 | 0.8370/0.8030 | 0.8380/0.8050 | +0.0010/+0.0020 |\n| PointRend | ISIC/kvasir | 0.8245/0.7930 | 0.8315/0.8010 | 0.8345/0.8055 | 0.8355/0.8075 | +0.0010/+0.0020 |\n| I-MedSAM | ISIC/kvasir | 0.8560/0.8960 | 0.8660/0.9030 | 0.8705/0.9060 | 0.8720/0.9080 | +0.0015/+0.0020 |\n| Fractal-G | ISIC/kvasir | 0.8843/0.9060 | 0.8968/0.9130 | 0.8934/0.9160 | 0.8933/0.9180 | -0.0001/+0.0020 |\n\n## W2: Hyperparameter sweeps and fairness of comparison\n\nWe clarify: (i) all methods share one protocol (W1 & Q1), mirroring nnU-Net's controlled-ablation philosophy [3]; (ii) our claim rests on paired backbones $\\pm$ Fractal-G (Table 2), which shows +4.79 Dice and -13.32 HD95 on Kvasir-SEG.\n\nWe now provide **sensitivity analyses** for the design choices singled out by the AC and reviewers (all on Kvasir-SEG, U-Net + Fractal-G):\n\n**Table 2.** Sensitivity of Fractal-G to its fixed design choices (Kvasir-SEG).\n\n| Choice | Values tested | Dice range | HD95 range |\n|:--------------------------|:-------------------------|:-------------|:-------------|\n| Fission threshold $\\tau$ | 0.3 / 0.5 / 0.7 | 90.81--91.66 | 9.88--11.47 |\n| Patch scale $P$ | 2 / 4 / 8 | 87.01--91.66 | 9.88--16.20 |\n| KNN size $K_{\\mathrm{GNN}}$ | 2 / 4 / 8 / 16 / 32 / 64 | 89.20--91.66 | 9.52--17.50 |\n| KNN size $K_{\\mathrm{ren}}$ | 1 / 2 / 4 / 8 / 16 | 90.60--91.66 | 9.20--15.80 |\n\nExcluding the structural patch scale $P$ (chosen to match the encoder stride ratio), the remaining choices are insensitive: Dice varies by at most 2.5 points for $\\tau \\in [0.3,0.7]$ and $K \\geq 4$, and HD95 changes smoothly with $K$ — no performance cliff.\n\n## W3: \"Atypical\" failure patterns of U-Net in Fig. 3\n\nThe U-Net baseline is converged (W1 & Q1), so the qualitative behavior in Fig. 3 is not caused by under-training. Fig. 3 shows the cross-resolution stress test (256-trained model evaluated directly at 128/512). The jagged native boundaries motivate our work: discrete upsampling creates staircase artifacts that Dice misses but HD95 captures (U-Net 17.70 px vs. ours 9.88 px). We will clarify the caption.\n\n## W4 & Q2: How was nnU-Net trained?\n\nIn the submission, \"nnU-Net\" denotes the nnU-Net backbone re-implemented under our protocol (W1 & Q1), not the full self-configuring pipeline [3]; we apologize for the ambiguity. We now additionally report the official nnU-Net (1000 epochs, its own augmentation/loss):\n\n**Table 3.** Official nnU-Net pipeline vs. our method.\n\n| Method | ISIC 2017 Dice | ISIC 2017 HD95 | Kvasir-SEG Dice | Kvasir-SEG HD95 |\n|:-------------------------|---------------:|---------------:|----------------:|----------------:|\n| nnU-Net (official pipeline) | 88.01 | 28.34 | 89.90 | 15.40 |\n| U-Net + Fractal-G (ours) | 88.76 | 12.46 | 91.66 | 9.88 |\n\n## W5 & Q4: Experiments on more than two datasets; the DRIVE reference in Fig. 6\n\nFirst, a correction: the DRIVE mention in Fig. 6's caption was a drafting error — the figure contains only ISIC/Kvasir rows; we will correct the caption.\n\nWe add experiments on **DRIVE** (retinal vessels, 20/20 train/test), reporting **clDice** [1] (skeleton connectivity), the topology metric used in TopCoW [2]:\n\n**Table 4.** Results on DRIVE (all methods under identical protocol).\n\n| Method | Dice(FOV) | HD95 | clDice |\n|:------------------|----------:|------:|-------:|\n| U-Net | 64.48 | 38.60 | 0.30 |\n| Swinunet | 63.29 | 23.47 | 0.34 |\n| Transunet | 46.88 | 23.29 | 0.43 |\n| PointRend | 48.55 | 52.56 | 0.05 |\n| MedSAM2 | 59.96 | 19.51 | 0.48 |\n| U-Net + Fractal-G | 75.24 | 15.06 | 0.57 |\n\nFractal-G improves its backbone on all three metrics, with the largest gain on clDice (+0.27, 0.57 vs. 0.30).\n\n## W6: The trivial resize baseline for cross-resolution experiments\n\nWe add this baseline: train at $256^2$, test by resizing input to $256^2$ and the prediction back:\n\n**Table 5.** Cross-resolution evaluation with the resize-to-native baseline (Kvasir-SEG).\n\n| Method | $256 \\to 128$ Dice | $256 \\to 128$ HD95 | $256 \\to 512$ Dice | $256 \\to 512$ HD95 |\n|:----------------------|-------------------:|--------------------:|-------------------:|--------------------:|\n| U-Net direct | 60.93 | 26.71 | 70.85 | 147.84 |\n| U-Net + resize-native | 86.72 | 25.76 | 87.78 | 92.36 |\n| Fractal-G direct | 83.55 | 12.84 | 91.54 | 25.31 |\n| Fractal-G + resize-native | 91.45 | 8.01 | 91.58 | 30.84 |\n\nResize recovers part of U-Net's Dice, but boundary quality remains worse (U-Net+resize lags Fractal-G by 67.05 HD95 at $512^2$). Fractal-G needs no resolution-dependent pre/post-processing.\n\n## Q3: Input images in Fig. 4\n\nAgreed — original images will be added to Figs. 3--5 in the revision.\n\n## R1 References\n\n[1] Shit, Suprosanna, et al. \"clDice-a Novel Topology-Preserving Loss Function for Tubular Structure Segmentation.\" 2021 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, 2021.\n\n[2] Junayed, Md Shakib Shahariar, et al. \"Topology-aware anatomical segmentation of the Circle of Willis: HUNet unveils the vascular network.\" IET Image Processing 18.10 (2024): 2745-2753.\n\nWe hope the revised paper meets your expectations. Glad to provide further responses if needed."
+ },
+ "createdAt": "2026-07-28T11:56:55.526Z",
+ "modifiedAt": "2026-11-18T17:11:49.324Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=LHpZxZcRuk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/rr8awdtcym.json added

+++ b/reviews/openreview/wrili56rip/notes/rr8awdtcym.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "rr8aWDtCYm",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer MMfo",
+ "content": {
+ "summary": "This work introduces a method to tackle a classic problem in medical segmentation tasks: the tradeoff one typically makes between high frequency details and low frequency semantic information. It presents a novel method Fractal-G which addresses these issues via a 3 step ‘grid-graph-grid’ methodology which slots between a standard encoder-decoder setup:\n\n- the first step constructs a heterogeneous graph by adaptively sampling nodes based on local information, where each node represents either deep/macroscopic/low frequency or shallow/microscopic/high frequency information based on a predicted per patch fission probability. A scale factor P fixes patch size (and thus node area). It is ensured that micro nodes are defined sparsely by adding a boundary loss encoding an eroded binary semantic label such that only a sparse boundary / ‘topological transition band’ is sampled.\n- the second step performs message passing on this heterogeneous graph, directly involving area into an attention coefficient via the area (relative to the macro / micro scale factor P associated with nodes). \n\n- the third step maps the graph to a continuous feature field, where a point q is assigned feature based on an aggregation of MLPs over its K nearest nodes and their distances from their geometric centres, which are again defined by scale factor P. The resulting feature is residually added to shallow encoded feature before being decoded. \n\nExperiments are conducted on ISIC 2017, Kvasir-SEG datasets, and a generalisation task is also considered on CVC-ClinicDB dataset as well as cross resolution. Dice and HD95 scores are reported indicating improvement over state of the art models, and also improvement of other models’ performance when integrated. Qualitative results are also shown indicating faithful representation of topology relative to ground truth and better than other models. Ablations are shown isolating the improvements of all three components that make up the model.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths\n- the three step approach is well motivated by the discussion of targeting the tradeoff between high and low frequency information. Experiments suggest quantitative and qualitative improvements over state of the art models as well as out of distribution generalisability on the single cross domain benchmark tested. \n- the paper is very readable, with a clear narrative: it motivates the problem at hand by appealing to issues in both discrete and continuous representations for segmentation tasks, as well as the tradeoff between semantics and geometric details. It then presents its solution to these issues via its three step method, and finally demonstrates that all three components are important and lead to an overall improved method for its considered datasets.\n- the paper presents a model that improves upon current state of the art in the chosen benchmarks. The model is backed by novel choices to tackle known problems and so fits well within the segmentation literature.\n- The identified problem is not necessarily a new one (high frequency vs low frequency), but the method presented is novel in its solution.\n\nWeaknesses\n- how would the model fare with more topologically interesting datasets? The chosen datasets are clearly diverse in their biology, but ultimately result in compact blob like structures as the final segmentation. I would be interested to see a discussion and/or experiments regarding more complex vascular-like structures where the need for geometrically and topologically faithful representations are more central, particularly with issues such as faithful connectedness. It seems like an obvious choice for such a model.\n- choice of P? Perhaps i have missed it but it seems this is a rather important choice. It is stated that it is set to P=4 for experiments. It would be nice to see at least a brief description of the models dependence on this scale factor, as it links back to one of the key claims made regarding formalising ‘the conflict in frequency and information density between global semantics and local boundaries’.\n- ablations measured in HD95? It is quite hard to tell the improvements beyond the introduction of UAFR in the ablation (fig 5, table 5) - perhaps it would be nice to see the HD95 scores in addition to DICE to show how each component affects boundaries beyond the qualitative description. \n- section 4.2 gives a different training setup to Appendix B.2",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "See weaknesses",
+ "limitations": "yes",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "NA",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Thank you very much for the in-depth response and the additional investigations. It is encouraging to see the results on a vascular dataset with more topologically complex structures.\n\nProvided that the relevant training protocols are reported clearly and consistently in the revised paper, and that no further experimental-design concerns arise from the discussion with Reviewer FAji, I would be comfortable raising my score to 5."
+ },
+ "createdAt": "2026-06-26T00:37:47.594Z",
+ "modifiedAt": "2026-11-18T13:36:02.033Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=rr8aWDtCYm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/submission.json added

+++ b/reviews/openreview/wrili56rip/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "WrIli56RIP",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 5141,
+ "url": "https://openreview.net/forum?id=WrIli56RIP",
+ "license": "CC-BY-4.0"
+}

versions/v_aum527kv.json added

+++ b/versions/v_aum527kv.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-25",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 5141,
+ "url": "https://openreview.net/forum?id=WrIli56RIP",
+ "reviews": "openreview/wrili56rip",
+ "evidence": [
+ "https://openreview.net/forum?id=WrIli56RIP"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=WrIli56RIP",
+ "evidence": [
+ "https://openreview.net/forum?id=WrIli56RIP"
+ ]
+}