potentialpaper

Fractal-G: Topology-Aware Heterogeneous Graphs for Medical Image Segmentation

Update NeurIPS 2026 submission WrIli56RIP: 10 notes

@openreview[bot] · 2026-11-24 15:52 UTC · 172f55b631d4 ·

Evidence

reviews/openreview/wrili56rip/notes/1g1hd5lp0t.json added

+++ b/reviews/openreview/wrili56rip/notes/1g1hd5lp0t.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "1g1hd5lp0t",
+ "replyTo": "3gC0WmAQLY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer FAji",
+ "content": {
+ "comment": "Dear Area Chair, Reviewers, and Authors. \n\nMy concerns were consolidated after another careful evaluation of the paper and the rebuttal. Please see my detailed concerns below. \n\n1.) The lacking baseline of just resampling the images to different resolutions in the inference step prompted me to perform a detailed analysis of the standard remedy for the multi-resolution problem, revealing a large corpus of works utilizing the multi-scale training paradigm that is fully absent in this work (no mention of it in the related work, and no utilization as a comparison method). (See more details and a selection of works utilizing this method in my detailed answer below.)\n\n2.) The evaluation of the DRIVE dataset at a resolution that destroys capillaries, as well as the performance of the baseline method, is concerning, and even more so when it is used to do topological evaluation (Reviewer MMfo). Exactly in a setting where the topological integrity of the vessel structures is destroyed by downsampling. \n\n3.) The second iteration of reporting \"nnU-net\" in the results, although not adhering to the nnU-net prescribed protocol, is another concerning experimental flaw. \n\nGiven all these concerns, especially (1), I cannot recommend accepting this paper."
+ },
+ "createdAt": "2026-08-04T10:20:49.564Z",
+ "modifiedAt": "2026-11-19T16:59:50.649Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=1g1hd5lp0t",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/3gc0wmaqly.json added

+++ b/reviews/openreview/wrili56rip/notes/3gc0wmaqly.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "3gC0WmAQLY",
+ "replyTo": "chgP87LpVz",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "# Author Final Remarks\n\nDear Area Chair and Reviewers,\n\nWe sincerely thank the Area Chair and all Reviewers for their careful feedback. We are grateful that Reviewer MMfo engaged with our rebuttal and increased the rating from 4 to 5. Although Reviewer FAji did not join the subsequent discussion, we addressed the methodological concerns point by point. We also thank Reviewer Mbd5 for recognizing the importance of boundary precision, the paper’s clarity, and Fractal-G’s efficiency, and have addressed each question.\n\n## Response to the Area Chair’s main concerns\n\n**Scope and structurally complex targets.** We agree that evaluation on ISIC 2017 and Kvasir-SEG alone did not justify broad claims about medical segmentation, clinical utility, or topological fidelity. We therefore added **DRIVE**, whose thin, branching vessels provide a connectivity-sensitive setting. Fractal-G improves its U-Net backbone from **64.48 to 75.24 Dice**, **38.60 to 15.06 HD95**, and **0.30 to 0.57 clDice**. We will scope our claims explicitly to **2D binary segmentation** and will not imply demonstrated 3D applicability or clinical deployment; 3D validation remains future work.\n\n**Technical distinction and robustness.** Our contribution is not adaptive sampling, graph propagation, or implicit decoding in isolation, but their coupling in a **Grid–Graph–Grid representation**. Unlike output-only refinement, fission changes the intermediate representation; unlike conventional graph aggregation, our message passing accounts for nodes’ unequal physical areas; and heterogeneous graph neighborhoods support continuous rendering. We added sensitivity analyses for the fission threshold $\\tau$, patch scale $P$, and graph/rendering KNN sizes. The results vary smoothly rather than relying on a fragile setting, while $P=4$ is justified by the encoder stride ratio. Boundary supervision requires no extra annotation because it is derived from the segmentation mask, and the appendix connects it to the router-calibration term in our approximation bound. Using a symmetric rather than internal boundary band changes Dice by less than 0.05 points.\n\n**Meaning of “topology-aware.”** We appreciate this important distinction. Here, the term means that **connectivity in the dynamically constructed graph is used during feature propagation and continuous reconstruction**. It does **not** imply a topological objective or formal guarantee. We will revise the terminology and claims accordingly. DRIVE clDice provides empirical evidence of improved connectivity, which we will present as evidence rather than a guarantee.\n\n**Experimental protocol and cross-resolution baseline.** We corrected the inconsistent descriptions. All controlled comparisons use AdamW, lr $10^{-4}$, weight decay $10^{-5}$, cosine annealing with five warm-up epochs, **200 epochs**, batch size 16, identical augmentations, and best-validation-Dice checkpoint selection; validation curves plateau before epoch 200. We will state exact dataset splits and distinguish our controlled nnU-Net-style backbone from the additional **official nnU-Net pipeline trained for 1000 epochs**. We also added the requested resize-to-native baseline. Since resizing recovers much of U-Net’s Dice, we will soften “catastrophic degradation”; nevertheless, at $256\\!\\to\\!512$, HD95 remains **92.36** for U-Net with resizing versus **25.31** for direct Fractal-G inference.\n\n## Summary by Reviewer\n\n**Reviewer FAji (rating 2 / confidence 3).** We provided convergence curves, unified the training protocol, evaluated official nnU-Net, added DRIVE with clDice and the resize baseline, and will improve the qualitative figures. Paired backbone comparisons with/without Fractal-G provide the key controlled evidence. The reviewer did not participate in the subsequent discussion.\n\n**Reviewer MMfo (4→5 / confidence 4).** We added DRIVE with topology-specific evaluation, sensitivity to $P$, HD95-based component ablations, and the corrected training protocol. We deeply appreciate the reviewer’s follow-up and score increase.\n\n**Reviewer Mbd5 (rating 5 / confidence 3).** We clarified the fixed threshold and graph simplification, added sensitivity and HD95 ablations, and will revise Figures 3–7 to better show inputs, node types, neighborhoods, and attention weights. We sincerely appreciate the encouraging evaluation and thoughtful suggestions.\n\nOverall, the rebuttal adds a connectivity-sensitive benchmark, topology-specific evaluation, sensitivity analyses, convergence evidence, official nnU-Net comparison, and the missing resize baseline, while narrowing our claims to match the evidence. We again thank the Area Chair and Reviewers and hope these additions support a fair assessment.\n\nBest regards, \nThe Authors"
+ },
+ "createdAt": "2026-08-04T09:33:38.843Z",
+ "modifiedAt": "2026-11-19T16:59:50.468Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=3gC0WmAQLY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/4dqviu5on6.json added

+++ b/reviews/openreview/wrili56rip/notes/4dqviu5on6.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "4dqvIU5on6",
+ "replyTo": "JB6P1Ojlvl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer FAji’s Follow-up",
+ "comment": "Dear Reviewer FAji and Area Chair,\n\nThank you for the careful follow-up. We re-audited our experiments in light of these comments. We agree that our description did not clearly distinguish the controlled nnU-Net-style baseline from the additional official nnU-Net v2 run, and that our interpretation of the DRIVE experiment was too broad. We clarify and correct these points below.\n\n**W2: Protocol breadth.** We agree that a single shared protocol does not establish the best attainable performance of every competing method. It provides a controlled comparison, but not a per-method optimum. We will therefore remove claims of general superiority based on the cross-method ranking. Our narrower evidence is the paired comparison of the same backbone with and without Fractal-G under the same protocol, which isolates the module’s marginal effect. We will explicitly state that multi-protocol/per-method tuning remains necessary for claims about best achievable performance.\n\n**W3: Qualitative U-Net failure.** The reviewer is correct: the native-resolution example contains false-positive connected components below the principal object, not merely a jagged boundary. Our previous reply addressed only the latter and therefore missed the central concern. We will identify these components explicitly, include the input image, and avoid attributing the entire failure to interpolation. Convergence shows that the checkpoint was not simply unfinished, but it does not make this qualitative failure unimportant.\n\n**W4: nnU-Net.** Our first response did not clearly distinguish two baselines. The submission row is a re-implemented **nnU-Net-style backbone under our controlled protocol** and will be renamed. In contrast, the rebuttal result used the **official nnU-Net v2 self-configuring pipeline**, including fingerprint extraction, automatic planning/preprocessing, default trainer/augmentation/loss, and 1000 epochs. The generated 2D plans—not a manual $256^2$ setting—use spacing $[1,1]$, median size $[2000,3008]$, and patch $[640,1152]$ for Kvasir; and spacing $[1,1]$, median size $[530,621]$, and patch $[640,640]$ for ISIC. Thus, the reviewer’s assumption that this run retained $256^2$ preprocessing is incorrect. Due to rebuttal-time/compute constraints, we ran **fold 0 only**, not a five-fold ensemble; we will label it “official nnU-Net v2 (fold 0)” and report these plans explicitly.\n\n**W5: DRIVE.** We clarify the scope. We did not present this as a standard full-resolution benchmark, compare absolute scores with optimized literature results, claim native-capillary topology preservation, or infer intrinsically weak baselines. DRIVE images are $565\\times584$; for every method, training uses $224^2$ patches from images resized to $448^2$, while testing resizes the full image to $224^2$. Thus, comparison with Alom et al. under another protocol is not like-for-like. Downsampling limits conclusions about the finest native vessels, but does not invalidate the paired comparison on the same labels/grid. We retain the table and interpret Dice/clDice gains only as within-protocol evidence that Fractal-G improves its identically trained U-Net backbone on a branching target.\n\n**W6: Cross-resolution evaluation vs. multi-scale training.** Table 4 is not an evaluation of, or alternative to, multi-scale training. It is a **cross-resolution generalization** diagnostic: one checkpoint is trained at $256^2$ and evaluated on unseen grids ($128^2/512^2$), without retraining. This protocol has been adopted in prior medical image segmentation studies [1--4]. Multi-scale training instead changes the training distribution and asks whether scale augmentation improves performance; it is valuable but orthogonal to our diagnostic of representation/rendering under an unseen grid. We added the AC-requested resize control and will clarify this scope. We do **not** claim that Fractal-G outperforms multi-scale training; the two can be combined.\n\nThese clarifications do not change the paired backbone $\\pm$ Fractal-G results, component/sensitivity ablations, or official nnU-Net v2 fold-0 result. They establish performance under the stated protocols, not universal superiority. We thank the reviewer for prompting these clarifications.\n\n## References\n\n[1] Zhang, Yejia, et al. “SwIPE: Efficient and Robust Medical Image Segmentation with Implicit Patch Embeddings.” MICCAI, 2023.\n\n[2] Wei, Xiaobao, et al. “I-MedSAM: Implicit Medical Image Segmentation with Segment Anything.” ECCV, 2024.\n\n[3] Wu, Jinxuan, Jiange Wang, and Dongdong Zhang. “GauSAM: Contour-Guided 2D Gaussian Fields for Multi-Scale Medical Image Segmentation with Segment Anything.” NeurIPS, 2025.\n\n[4] Huang, Lianchao, et al. “HiImp-SMI: An Implicit Transformer Framework with High-Frequency Adapter for Medical Image Segmentation.” Frontiers in Physics 13 (2025): 1614983.\n\nSincerely, \nThe Authors"
+ },
+ "createdAt": "2026-08-04T11:57:23.956Z",
+ "modifiedAt": "2026-11-19T16:59:50.652Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=4dqvIU5on6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/6wo65muqzg.json added

+++ b/reviews/openreview/wrili56rip/notes/6wo65muqzg.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "6WO65MUQZG",
+ "replyTo": "kHw7CH7r0w",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer MMfo,\n\nThank you very much for the careful follow-up and for the encouraging assessment of our additional experiments — we are delighted that the vascular results with topology-specific metrics help address your concerns about structurally complex targets.\n\nWe will make sure the training protocol is reported clearly and consistently in the revised paper, and we are also happy to address any further experimental-design points that may come up in the discussion with Reviewer FAji.\n\nThank you again for your constructive engagement with our work. Please do not hesitate to let us know if any additional clarification would be helpful.\n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-03T02:36:15.554Z",
+ "modifiedAt": "2026-11-19T16:59:50.548Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=6WO65MUQZG",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/chgp87lpvz.json modified

+++ b/reviews/openreview/wrili56rip/notes/chgp87lpvz.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair RmLQ",
"content": {
- "metareview": "The submission reports promising improvements in Dice, HD95, cross-domain generalization, and cross-resolution performance, and the Grid-Graph-Grid module is reasonably well motivated. However, both the reviewers and I have several concerns that need to be resolved before the paper can be seriously considered.\n\n- The experimental scope is limited to two 2D binary segmentation tasks with largely compact targets. This evidence does not yet support the broader claims regarding medical image segmentation, topology-aware modeling, or clinical utility. The rebuttal should clarify the intended scope and indicate whether any existing results are available on more structurally complex targets.\n- The technical novelty and robustness of the design need clearer justification. Fractal-G combines boundary-guided adaptive sampling, graph message passing, and implicit rendering, while relying on several fixed or heuristic choices, including the hard fission threshold, patch scale, KNN construction, and explicit boundary supervision. Please explain the main technical distinction from prior adaptive-sampling, graph-based, and implicit-rendering methods, and provide any available sensitivity analysis for these choices.\n- The “topology-aware” framing is not justified. The current method uses graph connectivity during feature reconstruction, but the paper does not include an explicit topological objective, guarantee, or topology-specific evaluation. Please clarify precisely what topology awareness means in this work and which results demonstrate it.\n- Rebuttal should resolve the inconsistent training descriptions in the main paper and appendix, clarify the exact dataset splits, and explain how all baselines such as nn-Unet were trained and selected. The cross-resolution experiment should also be interpreted against the simple baseline of resizing inputs to the native training resolution and resizing predictions back."
+ "metareview": "The submission reports promising improvements in Dice, HD95, cross-domain generalization, and cross-resolution performance, and the Grid-Graph-Grid module is reasonably well motivated. However, both the reviewers and I have several concerns that need to be resolved before the paper can be seriously considered.\n\n- The experimental scope is limited to two 2D binary segmentation tasks with largely compact targets. This evidence does not yet support the broader claims regarding medical image segmentation, topology-aware modeling, or clinical utility. The rebuttal should clarify the intended scope and indicate whether any existing results are available on more structurally complex targets.\n- The technical novelty and robustness of the design need clearer justification. Fractal-G combines boundary-guided adaptive sampling, graph message passing, and implicit rendering, while relying on several fixed or heuristic choices, including the hard fission threshold, patch scale, KNN construction, and explicit boundary supervision. Please explain the main technical distinction from prior adaptive-sampling, graph-based, and implicit-rendering methods, and provide any available sensitivity analysis for these choices.\n- The “topology-aware” framing is not justified. The current method uses graph connectivity during feature reconstruction, but the paper does not include an explicit topological objective, guarantee, or topology-specific evaluation. Please clarify precisely what topology awareness means in this work and which results demonstrate it.\n- Rebuttal should resolve the inconsistent training descriptions in the main paper and appendix, clarify the exact dataset splits, and explain how all baselines such as nn-Unet were trained and selected. The cross-resolution experiment should also be interpreted against the simple baseline of resizing inputs to the native training resolution and resizing predictions back.",
+ "final_justification": "I have read the author responses and the subsequent reviewer discussion carefully. The rebuttal improves the paper and addresses most of the concerns raised in my initial meta-review. My initial concerns focused on four issues: the limited experimental scope, the strength of the topology-aware claims, sensitivity to several fixed design choices, and uncertainty around the training protocol and baseline comparisons. The rebuttal made meaningful progress on each.\n\nThe main remaining disagreement concerns experimental comparison. Reviewer FAji raises important points about the original nnU-Net labeling, the DRIVE resolution, and the absence of multi-scale training as a comparison for resolution robustness. I agree that these issues limit some of the broader claims in the submitted version. In particular, I would not interpret the DRIVE result as evidence that native fine-vessel topology is preserved, and I do not think the current experiments establish superiority over all approaches designed for multi-scale training. The original nnU-Net row should also not have been presented as the standard nnU-Net pipeline.\n\nThe reviewers remained divided after rebuttal. MMfo found the new vascular experiment, sensitivity analysis, and protocol clarification sufficient to raise the rating to 5. Mbd5 also maintained a rating of 5 after considering the remaining baseline-protocol concern. FAji remained at 2 with confidence 5 and identified the experimental limitations discussed above. On balance, the rebuttal moved the paper slightly above the acceptance threshold for me. I recommend acceptance, with the expectation that the final version clearly distinguishes controlled baselines from official implementations, narrows the topology and cross-resolution claims, and presents the DRIVE experiment with the appropriate limitations."
},
"createdAt": "2026-07-23T08:01:30.513Z",
- "modifiedAt": "2026-11-18T15:19:06.587Z",
+ "modifiedAt": "2026-11-19T04:59:29.297Z",
"url": "https://openreview.net/forum?id=WrIli56RIP&noteId=chgP87LpVz",
"license": "CC-BY-4.0"
}

reviews/openreview/wrili56rip/notes/h7djl73byo.json added

+++ b/reviews/openreview/wrili56rip/notes/h7djl73byo.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "H7dJl73byO",
+ "replyTo": "LHpZxZcRuk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer,\nWith just over one day remaining before the Author–Reviewer discussion period closes, we would be very grateful if you could take a moment to review our rebuttal. We hope that our responses and additional experiments have adequately addressed your concerns, and we would be happy to provide any further clarification if needed.\nIf you feel that your concerns have been sufficiently addressed, we would sincerely appreciate it if you could consider updating your assessment accordingly.\nThank you again for your time and thoughtful feedback.\nBest regards,\nThe Authors"
+ },
+ "createdAt": "2026-08-03T11:39:48.875Z",
+ "modifiedAt": "2026-11-19T16:59:50.562Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=H7dJl73byO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/jb6p1ojlvl.json added

+++ b/reviews/openreview/wrili56rip/notes/jb6p1ojlvl.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "JB6P1Ojlvl",
+ "replyTo": "LHpZxZcRuk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer FAji",
+ "content": {
+ "comment": "- W5:\n\nThank you for adding the result of the Drive dataset. The reported Dice scores raise major concerns for the experimental procedure chosen by the authors. Numerous papers report Dice scores for U-Net baselines and other architectural baselines. None of these papers report Dice scores in the area of 60% or even lower as you report them for Transunet. Naming just one: Alom et al. [1] report F1 scores (Dice) of 81% for U-Net, Residual U-Net, and Recurrent U-Net. \n\nThe issue most likely arises from downscaling to a smaller sample resolution. Since no information on the resolution is mentioned here, I assume it was also downsampled to 256x256. What is the purpose of this downsampling step? Why is the comparison not done on the largest possible joint resolution of the dataset, as it is a community standard? A topological analysis of the DRIVE dataset in this resolution is extremely problematic because the downsampling destroys thin vessels and connectivity within thin vessel branches. This also raises major concerns about the answers to Reviewer MMfo. \n\n[1] Alom, Md Zahangir, et al. \"Recurrent residual convolutional neural network based on u-net (r2u-net) for medical image segmentation.\" arXiv preprint arXiv:1802.06955 (2018).\n\n\n- W6:\n\nThank you for reporting the trivial baseline here. Already, this extremely trivial baseline sets the benefits of the proposed method into proportion. However, this is only the trivial starting point for a proper evaluation of the method. \nThere is a severe lack of comparison to well-established literature. Not only is there no comparison to the dominating method of multiscale training, which achieves excellent performance on the two investigated datasets. Leaving all of this literature out [1-7] – and not having the well-established remedy of the resolution problem in polyp segmentation, which is multi-scale training, either (1) mentioned nor (2) evaluated, is a fundamental flaw which cannot allow this work to be published in its current form.\n\n[1] Fan, Deng-Ping, et al. \"Pranet: Parallel reverse attention network for polyp segmentation.\" International conference on medical image computing and computer-assisted intervention. Cham: Springer International Publishing, 2020.\n\n[2] Wei, Jun, et al. \"Shallow attention network for polyp segmentation.\" International conference on medical image computing and computer-assisted intervention. Cham: Springer International Publishing, 2021.\n\n[3] Dong, Bo, et al. \"Polyp-pvt: Polyp segmentation with pyramid vision transformers.\" arXiv preprint arXiv:2108.06932 (2021).\n\n[4] Lou, Ange, et al. \"CaraNet: context axial reverse attention network for segmentation of small medical objects.\" Medical Imaging 2022: Image Processing. Vol. 12032. SPIE, 2022.\n\n[5] Chen, Feiyu, Haiping Ma, and Weijia Zhang. \"Segt: a novel separated edge-guidance transformer network for polyp segmentation.\" arXiv preprint arXiv:2306.10773 (2023).\n\n[6] Huang, Chien-Hsiang, Hung-Yu Wu, and Youn-Long Lin. \"Hardnet-mseg: A simple encoder-decoder polyp segmentation neural network that achieves over 0.9 mean dice and 86 fps.\" arXiv preprint arXiv:2101.07172 (2021).\n\n[7] Chen, Ziqiang, Kang Wang, and Yun Liu. \"Efficient polyp segmentation via integrity learning.\" ICASSP 2024-2024 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP). IEEE, 2024."
+ },
+ "createdAt": "2026-08-04T10:05:12.996Z",
+ "modifiedAt": "2026-11-19T16:59:50.379Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=JB6P1Ojlvl",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/khw7ch7r0w.json added

+++ b/reviews/openreview/wrili56rip/notes/khw7ch7r0w.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "kHw7CH7r0w",
+ "replyTo": "Dd8mr3DuGo",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer MMfo",
+ "content": {
+ "comment": "Thank you very much for the in-depth response and the additional investigations. It is encouraging to see the results on a vascular dataset with more topologically complex structures.\n\nProvided that the relevant training protocols are reported clearly and consistently in the revised paper, and that no further experimental-design concerns arise from the discussion with Reviewer FAji, I would be comfortable raising my score to 5."
+ },
+ "createdAt": "2026-08-02T22:48:59.986Z",
+ "modifiedAt": "2026-11-19T16:59:50.652Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=kHw7CH7r0w",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/kukc7a8gcm.json added

+++ b/reviews/openreview/wrili56rip/notes/kukc7a8gcm.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "kuKC7A8gCm",
+ "replyTo": "LHpZxZcRuk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer FAji",
+ "content": {
+ "comment": "Dear authors, \n\nThank you for your detailed answers and efforts to address my concerns. I appreciate your efforts. Unfortunately, my concerns regarding the experimentation remain unresolved. I still have major concerns regarding reported performance metrics and the lack of consideration of critical literature in the field. Please see my answers and remaining concerns (W2, W3, W4, W5, W6) below. \n\n- W1:\n\nThank you for clarifying the previously ill-defined training setting and for providing the validation scores for the ISIC/Kvasir dataset. This is an important step towards a more rigorous experimentation section.\n\n- W2:\n\nIt is a good starting point to conduct an evaluation using the same protocol across the different applied methods. However, a rigorous evaluation must include multiple protocols for each method to verify that not the exact protocol that was picked favors one specific method. In the deployment, the relevant metric is whether or not high performance can be achieved; methods that are not extremely robust to hyperparameter choices might be unfavorable at one specific protocol, while providing excellent performance on another protocol. To account for this, you should ideally evaluate all methods on multiple protocols. Something that is still missing from the paper. \n\n- W3: \n\nThank you for mentioning the boundary issues again. I see the problems with the boundary. However, to repeat my concerns – in the 256x256 image (the native resolution), the boundaries are not only jagged, but the much more noticeable thing is also that there are additional connected components in the bottom below the large marked-out area.\n\n- W4:\n\nThank you for clarifying that nnUnet was actually not trained with the nnUnet prescribed protocol. The whole point of having a fully pre-specified training protocol is destroyed if the nnUnet performance is reported, but the protocol is changed. It is extremely important to fully clarify this in the paper. Directly citing “nnU-Net [48]’’ in the tables without actually adhering to the prescribed protocol undermines the whole point of the paper. \n\nThe authors describe that they “now additionally report the official nnU-Net (1000 epochs, its own augmentation/loss):”. I have a fundamental concern here: the authors have now only adapted to 1000 epochs and the augmentation/loss handling of nnU-Net, but did not adapt the image resolution handling, keeping it at their arbitrarily chosen value of 256. This contradicts what the nnU-Net pipeline would actually do for images of different resolutions, and is the second time the authors describe a baseline as nnU-Net, which is not nnU-Net."
+ },
+ "createdAt": "2026-08-04T10:04:40.654Z",
+ "modifiedAt": "2026-11-19T16:59:50.452Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=kuKC7A8gCm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wrili56rip/notes/zqnzxbs0gb.json added

+++ b/reviews/openreview/wrili56rip/notes/zqnzxbs0gb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ZqnzXbs0GB",
+ "replyTo": "1g1hd5lp0t",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer FAji’s Follow-up",
+ "comment": "Dear Reviewer FAji and Area Chair,\n\nThank you for the careful follow-up. We re-audited our experiments in light of these comments. We agree that our description did not clearly distinguish the controlled nnU-Net-style baseline from the additional official nnU-Net v2 run, and that our interpretation of the DRIVE experiment was too broad. We clarify and correct these points below.\n\n**W2: Protocol breadth.** We agree that a single shared protocol does not establish the best attainable performance of every competing method. It provides a controlled comparison, but not a per-method optimum. We will therefore remove claims of general superiority based on the cross-method ranking. Our narrower evidence is the paired comparison of the same backbone with and without Fractal-G under the same protocol, which isolates the module’s marginal effect. We will explicitly state that multi-protocol/per-method tuning remains necessary for claims about best achievable performance.\n\n**W3: Qualitative U-Net failure.** The reviewer is correct: the native-resolution example contains false-positive connected components below the principal object, not merely a jagged boundary. Our previous reply addressed only the latter and therefore missed the central concern. We will identify these components explicitly, include the input image, and avoid attributing the entire failure to interpolation. Convergence shows that the checkpoint was not simply unfinished, but it does not make this qualitative failure unimportant.\n\n**W4: nnU-Net.** Our first response did not clearly distinguish two baselines. The submission row is a re-implemented **nnU-Net-style backbone under our controlled protocol** and will be renamed. In contrast, the rebuttal result used the **official nnU-Net v2 self-configuring pipeline**, including fingerprint extraction, automatic planning/preprocessing, default trainer/augmentation/loss, and 1000 epochs. The generated 2D plans—not a manual $256^2$ setting—use spacing $[1,1]$, median size $[2000,3008]$, and patch $[640,1152]$ for Kvasir; and spacing $[1,1]$, median size $[530,621]$, and patch $[640,640]$ for ISIC. Thus, the reviewer’s assumption that this run retained $256^2$ preprocessing is incorrect. Due to rebuttal-time/compute constraints, we ran **fold 0 only**, not a five-fold ensemble; we will label it “official nnU-Net v2 (fold 0)” and report these plans explicitly.\n\n**W5: DRIVE.** We clarify the scope. We did not present this as a standard full-resolution benchmark, compare absolute scores with optimized literature results, claim native-capillary topology preservation, or infer intrinsically weak baselines. DRIVE images are $565\\times584$; for every method, training uses $224^2$ patches from images resized to $448^2$, while testing resizes the full image to $224^2$. Thus, comparison with Alom et al. under another protocol is not like-for-like. Downsampling limits conclusions about the finest native vessels, but does not invalidate the paired comparison on the same labels/grid. We retain the table and interpret Dice/clDice gains only as within-protocol evidence that Fractal-G improves its identically trained U-Net backbone on a branching target.\n\n**W6: Cross-resolution evaluation vs. multi-scale training.** Table 4 is not an evaluation of, or alternative to, multi-scale training. It is a **cross-resolution generalization** diagnostic: one checkpoint is trained at $256^2$ and evaluated on unseen grids ($128^2/512^2$), without retraining. This protocol has been adopted in prior medical image segmentation studies [1--4]. Multi-scale training instead changes the training distribution and asks whether scale augmentation improves performance; it is valuable but orthogonal to our diagnostic of representation/rendering under an unseen grid. We added the AC-requested resize control and will clarify this scope. We do **not** claim that Fractal-G outperforms multi-scale training; the two can be combined.\n\nThese clarifications do not change the paired backbone $\\pm$ Fractal-G results, component/sensitivity ablations, or official nnU-Net v2 fold-0 result. They establish performance under the stated protocols, not universal superiority. We thank the reviewer for prompting these clarifications.\n\n## References\n\n[1] Zhang, Yejia, et al. “SwIPE: Efficient and Robust Medical Image Segmentation with Implicit Patch Embeddings.” MICCAI, 2023.\n\n[2] Wei, Xiaobao, et al. “I-MedSAM: Implicit Medical Image Segmentation with Segment Anything.” ECCV, 2024.\n\n[3] Wu, Jinxuan, Jiange Wang, and Dongdong Zhang. “GauSAM: Contour-Guided 2D Gaussian Fields for Multi-Scale Medical Image Segmentation with Segment Anything.” NeurIPS, 2025.\n\n[4] Huang, Lianchao, et al. “HiImp-SMI: An Implicit Transformer Framework with High-Frequency Adapter for Medical Image Segmentation.” Frontiers in Physics 13 (2025): 1614983.\n\nSincerely, \nThe Authors"
+ },
+ "createdAt": "2026-08-04T11:57:28.676Z",
+ "modifiedAt": "2026-11-19T16:59:50.309Z",
+ "url": "https://openreview.net/forum?id=WrIli56RIP&noteId=ZqnzXbs0GB",
+ "license": "CC-BY-4.0"
+}