Update NeurIPS 2026 submission p124P8VSQH: 7 notes
@openreview[bot] · 2026-11-24 15:55 UTC · 6b347cdb6c44 ·
reviews/openreview/p124p8vsqh/notes/b50zt49kfn.json added
+++ b/reviews/openreview/p124p8vsqh/notes/b50zt49kfn.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "b50Zt49kFn",+ "replyTo": "uFhuZkjvr8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Rebuttal for 2diP",+ "comment": "Thank you for recognizing the technical quality, thorough ablations, and long-tail results. We agree that the supervision claim and empirical scope need sharper boundaries. We provide systematic analyses and revisions below.\n\n**How does HeatRAD fail, and what is Figure 4's role?** Figure 4 is illustrative; the systematic evidence is our failure taxonomy. Per lesion, HeatRAD abstains on **4.6%** of true lesions (mainly chronic/background patterns or atypical anatomy), confidently misroutes **2.8%** (mainly pleura-parenchyma), and misses **26%** (**31%** in multi-lesion cases). DEAR has no routing module, precluding comparison. In an automatic, non-adjudicated analysis, per ground-truth finding HeatRAD vs. DEAR FN rates are **5.9% vs. 7.9%** (per-report macro FN: 9.6%), and FP rates are **3.3% vs. 5.1%** per generated finding; HeatRAD's laterality-only and severity/extent errors are **2.1%** and **1.6%**. On the subtle categories the framework targets, FN stays well below DEAR: **11.8% vs. 15.6%** for nodules $\\leq$10 mm and **13.2% vs. 17.1%** for low-contrast lung opacity (n=52). Residual errors center on organ attribution, extent wording. We will add this analysis alongside Figure 4.\n\n**fVLM provenance and “annotation-free.”** $E_{\\mathrm{txt}}$ is fVLM's frozen text branch (Shui et al., 2025), pretrained on MedVL-CT69K with auto-generated anatomical masks; curation undisclosed. Thus, “annotation-free” was too broad. We will replace it with: **no task-specific spatial or lesion supervision during HeatRAD training**; upstream fVLM did use masks. Organ-anchor agreement is 0.89 on RadGenome (native annotations), 0.85 on CTRG-Chest and 0.83 on BIMCV-R (TotalSegmentator pseudo-masks), and 0.81 on BIMCV-R's COVID subset, where F1 remains 0.272. Anchors enter cross-attention and routing, so errors may propagate; we will state this limitation.\n\n**Which rare abnormalities improve?** Gains over DEAR are largest in the lower-support tercile:\n\n| Support tercile | Categories (support, $\\Delta$F1) | Mean $\\Delta$F1 |\n|---|---|---|\n| Rarest 6 | pericardial effusion (42, **+0.13**); mosaic attenuation (28, **+0.11**); septal thickening (35, +0.06); hiatal hernia (31, +0.05); fibrotic sequelae (64, +0.05); lymphadenopathy (58, +0.03) | **+0.072** |\n| Middle 6 | peribronchial thickening; consolidation; bronchiectasis; medical material; arterial and coronary wall calcification | +0.050 |\n| Most frequent 6 | lung nodule; pleural effusion; atelectasis; emphysema; cardiomegaly; lung opacity | +0.047 |\n\nGain correlates with rarity ($\\rho=0.52$, p=0.026, n=18), consistent with, not proof of, budget under-coverage. For the GGO example, represented by the dataset's low-contrast **lung opacity** subgroup, Recall@8 is 0.76 vs. 0.34 (DEAR proxy) and FN is 13.2% vs. 17.1%. Yet $\\Delta$F1 is only +0.04 (absolute F1 0.62), indicating a wording bottleneck.\n\n**Suggested experiments and scope.** (i) Prospective radiologist evaluation is the decisive missing evidence; a blinded multi-reader study is future work. (ii) Three chest benchmarks test shifts in institutions, languages, reports, and diseases, but not abdominal or neurological CT. We will narrow the scope; other anatomies await common 3D RRG protocols. (iii) Against RadGenome lesion masks, slice scoring obtains AUROC **0.871** and Recall@8 **0.831**, vs. 0.74 for fVLM cosine and 0.71 for DEAR. Of slices with $\\alpha_j>0.8$, 78% contain a lesion (ECE 0.07). Thus, $\\alpha_j$ ranks slices well but is not a calibrated clinical probability.\n\n**Originality, cost, and equity.** We will revise the framing: the contribution is coupling signed in-plane HCO with non-negative inter-slice conduction, suspiciousness-first routing, and abstain-augmented sparsemax, not the primitives. Inference takes **2.6 s/volume** and **21.7 GB** on one RTX 4090; routing retains 386/2,048 slots (**5.3x** reduction), while cost is decoder-dominated. Sex/age subgroup results are uniform (spread 0.002 across sex, 0.012 across age; every subgroup above DEAR's full-set F1), but one benchmark cannot establish equity across imaging contexts.\n\nWe will add: *Limitations.* “HeatRAD relies on a frozen biomedical text encoder and fixed RadLex organ prompts; anchor errors may propagate under scanner, institutional, or population shift. Evaluation covers three chest CT benchmarks; other anatomies remain untested. Slice suspiciousness is not a calibrated probability. Post-surgical or congenital anatomy may weaken organ attribution. The 8B decoder is costly, and clinical validity is not established prospectively.”\n\n*Implications.* “A fluent, organ-attributed report may create over-trust when routing is wrong. Abstain mass is internal, not a calibrated clinical warning; interfaces must communicate uncertainty explicitly. HeatRAD is an assistive-drafting research prototype, not a diagnostic device; clinical use requires prospective validation, subgroup analysis, and human-factors evaluation.”"+ },+ "createdAt": "2026-07-28T16:22:05.428Z",+ "modifiedAt": "2026-11-19T16:48:14.214Z",+ "url": "https://openreview.net/forum?id=p124P8VSQH¬eId=b50Zt49kFn",+ "license": "CC-BY-4.0"+}
reviews/openreview/p124p8vsqh/notes/cv9hxd5y0d.json added
+++ b/reviews/openreview/p124p8vsqh/notes/cv9hxd5y0d.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "cv9hXD5Y0D",+ "replyTo": "Dy8IHfF2EQ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Followup Response to Reviewer T5J1's Formatting Concerns",+ "comment": "Thank you for highlighting these presentation issues. We agree that they affect readability at the standard review scale. In the revised version, we will (1) enlarge the text and labels and simplify the layouts of Figures 2 and 3; (2) reorganize Table 1 by separating the NLG results from the clinical and grounding results, with secondary results moved to the appendix as needed; (3) enlarge Figure 4 and present the reference report more prominently; and (4) correct “DEARpartially” to “DEAR partially,” remove the extra space before the period in the qualitative-case paragraph, and proofread the manuscript for similar typographical issues. These presentation-only revisions will not change the method, reported results, or conclusions. We appreciate these concrete suggestions, which will improve the paper's readability."+ },+ "createdAt": "2026-08-02T04:26:39.735Z",+ "modifiedAt": "2026-11-19T16:48:13.909Z",+ "url": "https://openreview.net/forum?id=p124P8VSQH¬eId=cv9hXD5Y0D",+ "license": "CC-BY-4.0"+}
reviews/openreview/p124p8vsqh/notes/fcvg3ktl1z.json added
+++ b/reviews/openreview/p124p8vsqh/notes/fcvg3ktl1z.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "FCVg3ktl1Z",+ "replyTo": "0tiS9eooPr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Reply to Ethics Reviewer RYsf",+ "comment": "We thank you for the careful ethics assessment. We agree that the manuscript does not discuss its limitations and clinical risks prominently enough, and we address each concern below.\n\n**1. Limitations, risks, and intended use (flagged concern 1; mitigations 1 and 3).** We will add a standalone section stating:\n\n> **Limitations.** HeatRAD relies on a frozen biomedical text encoder and fixed RadLex organ prompts; their errors may propagate under scanner, institutional, population, or anatomical shift. Evaluation covers three chest CT benchmarks; other anatomies remain untested. The sex/age analysis is retrospective and single-benchmark, and the slice suspiciousness score is not a calibrated probability. Post-surgical, congenital, bilateral, multifocal, or diffuse findings may weaken organ attribution. The 8B decoder is costly, and prospective clinical validity is not established.\n>\n> **Ethical considerations.** HeatRAD is an assistive-drafting research prototype, not a diagnostic device, and must not be used for autonomous diagnosis or clinical decisions. Fluent, organ-structured reports may create over-trust when routing or generation is wrong. Selected organ channels and slices are inspectable routing information, not faithful explanations or correctness guarantees for individual findings. The abstain mass is not a calibrated clinical warning. Clinicians must verify every output against the source CT.\n\n**2. Demographic subgroup evaluation (additional concern 1; mitigation 2).** Using CT-RATE age/sex metadata, we analyzed the 1,564 RadGenome-ChestCT evaluation volumes from 1,304 patients, using patients as the resampling unit and 10,000 patient-level bootstraps. Every subgroup 95% CI has a half-width of at most 0.02:\n\n| Subgroup | n (patients) | F1 |\n| --- | ---: | ---: |\n| Female | 578 | 0.703 |\n| Male | 726 | 0.701 |\n| Age 18–40 | 518 | 0.707 |\n| Age 41–65 | 562 | 0.701 |\n| Age >65 | 224 | 0.695 |\n\nThe observed spread is 0.002 across sex and 0.012 across age. Performance is descriptively similar across these strata, but one retrospective benchmark cannot establish demographic parity or rule out intersectional, site-specific, or underrepresented-condition disparities. Prospective, site-stratified subgroup validation remains required before clinical use.\n\n**3. Unusual presentations, domain shift, and safeguards (additional concern 2; mitigation 4).** Anchor agreement is 0.89 on RadGenome-ChestCT, 0.85 on CTRG-Chest, and 0.83 on BIMCV-R, decreasing to 0.81 on BIMCV-R's COVID-predominant subset, where report F1 is 0.272. These results quantify sensitivity within the evaluated domains; they are not a controlled true-OOD safety test or an online warning.\n\nThe slice suspiciousness score reaches AUROC 0.871 against lesion masks but is not calibrated as a clinical probability (ECE 0.07; 78% lesion-positive at $\\alpha_j>0.8$). The abstain mass is likewise not a validated alert, so HeatRAD has no validated fail-safe or OOD-warning mechanism. Clinical use would require prospective multi-site/OOD validation, radiologist verification, calibrated and human-factors-tested uncertainty communication, monitoring for degradation, and an out-of-scope fallback. We will also replace “trained from reports alone” with “trained on volume–report pairs without task-specific spatial or lesion supervision,” while disclosing report supervision, the frozen fVLM encoder, and fixed RadLex prompts.\n\n**4. Chest-only scope (flagged concern 2).** All three benchmarks concern chest CT; no conclusion about complete-body imaging follows. This scope mirrors the field: compared 3D RRG methods are established on chest CT benchmarks, and other anatomies lack a common evaluation protocol. Performance and organ routing on abdominal, neurological, or other anatomy remain untested and will be stated as future work.\n\n**5. Computational cost and deployment feasibility (flagged concern 3).** Training uses 8 RTX 4090 GPUs and a LoRA-tuned Llama3-8B decoder. Single-GPU inference requires 21.7 GB peak VRAM and 2.6 s per volume. Sparse routing retains $386\\pm142$ of 2,048 prefix slots (about a 5.3× reduction), but end-to-end cost remains decoder-dominated; we do not claim the system is lightweight. These measurements do not establish PACS integration, clinical throughput, workflow compatibility, or deployment feasibility."+ },+ "createdAt": "2026-07-29T10:58:56.988Z",+ "modifiedAt": "2026-11-19T16:48:13.935Z",+ "url": "https://openreview.net/forum?id=p124P8VSQH¬eId=FCVg3ktl1Z",+ "license": "CC-BY-4.0"+}
reviews/openreview/p124p8vsqh/notes/gkhp94bi4d.json added
+++ b/reviews/openreview/p124p8vsqh/notes/gkhp94bi4d.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "gkHp94bi4D",+ "replyTo": "oKoxNhZdGk",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Reply to Ethics Reviewer HnAg",+ "comment": "We thank you for recognizing the submission's data-privacy and human-subjects compliance and for identifying two transparency gaps. We agree with both required changes.\n\n**1. Scope of the centroid-based grounding metric (C1).** We agree that one organ-level centroid is uninformative for bilateral, multifocal, distributed, or diffuse findings. We also clarify a notational omission in Eq. (19). Because Eq. (14) includes abstention, the implemented centroid is\n\n $$\\hat{\\mathbf{c}}_k = \\frac{\\sum_{j=1}^{D} \\pi_{k,j} (\\bar{x}_{k,j}, \\bar{y}_{k,j}, z_j)}{\\sum_{j=1}^{D} \\pi_{k,j}}, \\qquad \\sum_{j=1}^{D} \\pi_{k,j} = 1 - \\pi_{k,0} > 0.$$ \n\nThe implementation already applies this normalization; only the displayed denominator was omitted, so the reported CDE values are unchanged. An all-abstain case is treated as no localization prediction and counted as a miss.\n\nThis normalization makes the centroid well-defined but not suitable for multi-site disease. Consistent with our response to Reviewer KgpT, we retain CDE only as a secondary summary for focal, single-site findings and use lesion-wise coverage as the primary multi-site metric. Each connected-component lesion is covered if any selected evidence point—an attention-weighted in-plane centroid at the slice's physical axial coordinate—falls inside its mask or within a 15 mm 3D physical-distance tolerance. Bilateral organs are scored separately by side.\n\nCoverage is **0.74 overall**, **0.69 on multi-lesion volumes**, and **0.71 per side on bilateral cases**, versus **0.66** using one organ-level centroid. Correspondingly, single-centroid CDE increases from **12.3 mm** on single-lesion cases to **24.7 mm** on multi-lesion cases.\n\nWe will state beside Eq. (19) that neither metric captures the full extent of diffuse disease, guarantees coverage of every clinically relevant lesion, or constitutes clinical validation of generated statements.\n\n**2. Slice budget, missing settings, and evaluation parity (C2).** The exact slice budget is **D=64 slices at 256×256 in-plane resolution**, after resampling volumes to 1×1×3 mm voxels. The complete configuration is:\n\n| Setting | Value |\n| --- | --- |\n| Slice budget / in-plane size | D=64 / 256×256 |\n| HU preprocessing | Clip to [−1000, 1000], then z-score using training-split statistics |\n| $\\tau_s$ / $\\tau_o$ initialization | 0.1 / 0.5, softplus-parameterized |\n| Abstain anchor / organ-bag dropout | 1.0 / annealed from 0.5 to 0 over the first 15 epochs |\n| LoRA | rank 64, scale 64, dropout 0.05, attention and MLP projections |\n| Optimization | AdamW; weight decay 0.05; learning rates $10^{-4}$ for visual modules and $2\\times10^{-4}$ for LoRA; one-epoch warm-up followed by cosine decay over 30 epochs; effective batch size 16 |\n| Software / hardware | PyTorch 2.5.1, CUDA 12.4, 8×RTX 4090 |\n\nWe will add these settings to Section 4.2 and provide the exact 32 RadLex prompt strings, full inference instruction, evaluator versions/checkpoint identifiers, input section, and aggregation settings in the camera ready and released code.\n\n**3. Baseline evaluation parity.** Published rows provide literature-level context under their original implementations. Rows marked † are our reproductions under the stated unified setting, and rows marked ‡ are 2D methods adapted to 3D inputs through M3D-CLIP. All outputs generated by us are evaluated using the same metric implementations and default checkpoints in the same software and hardware environment. \n\nTo isolate the routing contribution, we separately use a DEAR-matched control with the same Llama3-8B decoder, LoRA configuration, D=64 slice budget, preprocessing, data split, optimization schedule, training budget, hardware, and random seeds as HeatRAD. Full matched-protocol settings and results are provided in our response to Reviewer T5J1, Item 3. It publishes results as literature-level comparisons and use the DEAR-matched control only for the controlled routing comparison."+ },+ "createdAt": "2026-07-29T09:33:06.645Z",+ "modifiedAt": "2026-11-19T16:48:14.212Z",+ "url": "https://openreview.net/forum?id=p124P8VSQH¬eId=gkHp94bi4D",+ "license": "CC-BY-4.0"+}
reviews/openreview/p124p8vsqh/notes/jpfwzaxuch.json modified
+++ b/reviews/openreview/p124p8vsqh/notes/jpfwzaxuch.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair urqP","content": {- "metareview": "The paper proposes HEATRAD, a glance-before-tell framework for generating radiology reports from 3D CT volumes without relying on external segmentation masks or fixed phrase queues. It utilizes a signed heat-conduction slice encoder, a suspicious-slice discovery module, and an organ-attributed confirmation module to route suspicious evidence into an organ-ordered visual prefix for LLM decoding. Evaluated across three public 3D chest CT benchmarks, the method demonstrates consistent improvements over prior baselines in clinical entity accuracy and spatial grounding.\n\nStrengths:\n- The glance-before-tell decomposition aligns well with radiologist workflows and offers better interpretability than dense 3D token feeding. \n- By avoiding external segmentation models during training, the framework prevents error cascades inherited from segmenter blind spots. \n- The evaluation incorporates clinically grounded metrics like GREEN, RaTEScore, and RadGraph entity F1, rather than relying solely on superficial n-gram metrics. \n- The evidence-gating mechanism yields compelling performance gains on rare or long-tail abnormalities. \n\nWeaknesses:\n- Removing non-negativity constraints in the signed HCO could erroneously amplify high-frequency CT artifacts (like quantum noise) while suppressing large-scale, low-frequency diffuse lesions.\n- It is not sufficiently clear if the baseline models were evaluated under identical conditions regarding the LLM backbone, LoRA rank, and slice budgets. \n- The learned slice anomaly score is trained indirectly without direct slice-level validation against ground-truth annotations, and the evaluation lacks a radiologist reader study to assess false findings.\n- Key concepts, including the physical analogy to \"heat conduction,\" the acronym HCO, and the formulation of the slice anomaly score, lack clear definitions. \n\nQuestions:\n- Reviewer gp4V & Reviewer KgpT: Please provide a clear mathematical definition of the signed HCO and explain how the model ensures numerical stability against high-frequency CT artifacts like quantum noise or metal artifacts.\n- Reviewer KgpT: How does HEATRAD perform when faced with diffuse or large-scale, low-frequency abnormalities (e.g., lobar consolidation), and can you provide slice-level validation (e.g., AUROC) directly against ground-truth abnormal slices?\n- Reviewer T5J1 & Reviewer KgpT: Can you explicitly confirm whether the 3D baselines were evaluated with the exact same Llama3-8B decoder, slice budget, and preprocessing pipeline as HEATRAD?\n- Reviewer T5J1 & Reviewer 2diP: Since the system relies on frozen text embeddings, how might domain shifts or unusual anatomical presentations affect the quality of the organ anchors, and what are the limitations of this annotation-free claim?\n\nSuggestions:\n- It is important to address all questions from all reviewers."+ "metareview": "The paper proposes HEATRAD, a glance-before-tell framework for generating radiology reports from 3D CT volumes without relying on external segmentation masks or fixed phrase queues. It utilizes a signed heat-conduction slice encoder, a suspicious-slice discovery module, and an organ-attributed confirmation module to route suspicious evidence into an organ-ordered visual prefix for LLM decoding. Evaluated across three public 3D chest CT benchmarks, the method demonstrates consistent improvements over prior baselines in clinical entity accuracy and spatial grounding.\n\nStrengths:\n- The glance-before-tell decomposition aligns well with radiologist workflows and offers better interpretability than dense 3D token feeding. \n- By avoiding external segmentation models during training, the framework prevents error cascades inherited from segmenter blind spots. \n- The evaluation incorporates clinically grounded metrics like GREEN, RaTEScore, and RadGraph entity F1, rather than relying solely on superficial n-gram metrics. \n- The evidence-gating mechanism yields compelling performance gains on rare or long-tail abnormalities. \n\nWeaknesses:\n- Removing non-negativity constraints in the signed HCO could erroneously amplify high-frequency CT artifacts (like quantum noise) while suppressing large-scale, low-frequency diffuse lesions.\n- It is not sufficiently clear if the baseline models were evaluated under identical conditions regarding the LLM backbone, LoRA rank, and slice budgets. \n- The learned slice anomaly score is trained indirectly without direct slice-level validation against ground-truth annotations, and the evaluation lacks a radiologist reader study to assess false findings.\n- Key concepts, including the physical analogy to \"heat conduction,\" the acronym HCO, and the formulation of the slice anomaly score, lack clear definitions. \n\nQuestions:\n- Reviewer gp4V & Reviewer KgpT: Please provide a clear mathematical definition of the signed HCO and explain how the model ensures numerical stability against high-frequency CT artifacts like quantum noise or metal artifacts.\n- Reviewer KgpT: How does HEATRAD perform when faced with diffuse or large-scale, low-frequency abnormalities (e.g., lobar consolidation), and can you provide slice-level validation (e.g., AUROC) directly against ground-truth abnormal slices?\n- Reviewer T5J1 & Reviewer KgpT: Can you explicitly confirm whether the 3D baselines were evaluated with the exact same Llama3-8B decoder, slice budget, and preprocessing pipeline as HEATRAD?\n- Reviewer T5J1 & Reviewer 2diP: Since the system relies on frozen text embeddings, how might domain shifts or unusual anatomical presentations affect the quality of the organ anchors, and what are the limitations of this annotation-free claim?\n\nSuggestions:\n- It is important to address all questions from all reviewers.",+ "final_justification": "The paper introduces a clinically intuitive, anomaly-guided framework for 3D radiology report generation that effectively improves spatial grounding without relying on rigid external segmenters. The reviewers agreed that the method demonstrates consistent empirical gains across multiple benchmarks, with particularly compelling improvements on rare and long-tail abnormalities. During the rebuttal, the authors rigorously addressed initial concerns by providing statistically robust controls, substituting flawed evaluation metrics with lesion-wise coverage assessments, and detailing a comprehensive failure taxonomy."},"createdAt": "2026-07-21T03:23:47.360Z",- "modifiedAt": "2026-11-18T15:19:11.461Z",+ "modifiedAt": "2026-11-19T04:59:32.255Z","url": "https://openreview.net/forum?id=p124P8VSQH¬eId=jpFWZAxUcH","license": "CC-BY-4.0"}
reviews/openreview/p124p8vsqh/notes/lfdrdihc5o.json added
+++ b/reviews/openreview/p124p8vsqh/notes/lfdrdihc5o.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "lfDrdiHc5o",+ "replyTo": "jpFWZAxUcH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Reply to AC",+ "comment": "We thank the AC for recognizing the relevance of *glance before tell*, interpretable sparse routing, avoidance of external segmenters, and consistent gains across three chest-CT benchmarks. We address the AC's questions and shared concerns with controlled evidence and narrower claims where needed.\n\n**Signed HCO, stability, and diffuse disease.** HCO means **Heat Conduction Operator**: DCT, frequency-wise multiplication by $G(u,v)=\\exp[-\\kappa_\\theta(u,v)]$, then inverse DCT. We remove $\\kappa_\\theta\\ge0$ only in-plane; inter-slice HCO remains non-negative. This is an inductive bias, not a physical model or formal guarantee; we use no clipping/band-limiting. Trained gains remain 0.82–1.19 in shallow stages and at most $2.57\\times$ in the deepest stage. At $\\sigma=60$ HU, F1 drops 4.3 points versus 5.4–6.1 for three encoder controls; HeatRAD also performs best under simulated metal artifacts. It exceeds matched DEAR on diffuse cases (F1 0.688 vs. 0.659; Hit@1 0.77 vs. 0.72). Removing inter-slice HCO costs 2.8 points on diffuse but 0.7 on focal cases, supporting its role in axially extended evidence.\n\n**Direct validation of suspiciousness and routing.** We will define $f_j$ as pooled slice $j$, and $\\alpha_j$ as its cosine contrast against volume-conditioned suspicious/normal prototypes—not disease classes. Against RadGenome masks, $\\alpha_j$ achieves AUROC 0.871, AUPRC 0.612, and Recall@8 0.831, versus AUROC 0.74 for fVLM cosine and 0.71 for a DEAR proxy. Recall@8 is 0.74–0.81 across four subtle-finding groups; microfractures are unannotated, so we claim no result. $\\alpha_j$ ranks slices but is uncalibrated (ECE 0.07). The gate is soft: 47% of lesion-positive slices with $\\alpha_j<0.1$ still receive organ-bag weight.\n\nThe reported long-tail trend is also systematic rather than dependent on Fig. 4: the lowest-support tercile gains +0.072 mean F1 over DEAR, including pericardial effusion (+0.13) and mosaic attenuation (+0.11), and gain correlates with rarity ($\\rho=0.52,\\ p=0.026$). We present this as an association, not proof that limited evidence budgets cause the trend.\n\nOne centroid is misleading for bilateral/multifocal disease. We correct Eq. 19's abstention normalization and prioritize lesion-wise coverage: 0.74 overall, 0.69 multi-lesion, and 0.71 bilateral per-side, versus 0.52/0.46/0.49 without Stage I. In the same model, oracle routing reduces automatic location/laterality errors from 7.9% to 4.6%, while uniform routing raises them to 14.7%; uncertainty errors barely change. This links routing to *where*-errors without claiming clinical adjudication.\n\n**Fair comparison and statistical robustness.** Published rows are literature context; $\\dagger$ rows are our reproductions and $\\ddagger$ rows are 2D adaptations. We retrained DEAR with the same Llama3-8B, LoRA, $D=64$ slices, preprocessing, splits, schedule, budget, hardware, and three seeds. HeatRAD improves F1 by +0.013/+0.013/+0.011 on RadGenome/BIMCV-R/CTRG; paired-bootstrap 95% CIs are [+0.006,+0.020], [+0.004,+0.022], and [+0.003,+0.019] ($p=0.004/0.008/0.011$). Differences from published DEAR are not attributed to our method. The revision will separate provenance and provide prompts, inference instruction, evaluator details, preprocessing, and hyperparameters.\n\n**Contribution and priors.** Novelty lies in coupling signed in-plane/non-negative inter-slice HCO, suspiciousness-first routing, and organ anchors with abstain-augmented sparsemax—not the primitives. We replace “annotation-free/trained from reports alone” with: **trained on volume–report pairs without task-specific spatial or lesion supervision.** fVLM was pretrained on MedVL-CT69K using auto-generated masks, and RadLex prompts are explicit dependencies. Anchor agreement falls from 0.89 on RadGenome to 0.81 on BIMCV-R's COVID subset, exposing shift risk.\n\n**Scope and responsible use.** We will add standalone Limitations and Ethical Considerations sections. Evidence is chest-only, with no prospective reader study, validated OOD warning, or deployment guarantee. Failure analysis finds 4.6% lesion abstention, 2.8% confident misrouting, and 26% missed instances; this is not clinical validation. Retrospective F1 spreads are 0.002 by sex and 0.012 by age, but cannot establish equity. Inference takes 2.6 s/volume and 21.7 GB; the 8B decoder dominates cost. HeatRAD is an assistive-drafting prototype, not a diagnostic device: radiologists must verify every output, routing views are inspectable evidence rather than faithful explanations or correctness guarantees, and abstention is not a clinical alert. A prospective blinded multi-reader study should use source CTs and a severity-weighted taxonomy of false findings, misses, location/laterality errors, and uncertainty errors. Multi-site/OOD, subgroup, calibration, and human-factors studies are also prerequisites for clinical use."+ },+ "createdAt": "2026-07-28T16:19:34.139Z",+ "modifiedAt": "2026-11-19T16:48:14.084Z",+ "url": "https://openreview.net/forum?id=p124P8VSQH¬eId=lfDrdiHc5o",+ "license": "CC-BY-4.0"+}
reviews/openreview/p124p8vsqh/notes/w1f2t8fyyi.json added
+++ b/reviews/openreview/p124p8vsqh/notes/w1f2t8fyyi.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "w1F2t8fyyi",+ "replyTo": "QKCTsUAITN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Reply to Ethics Reviewer 24Cy",+ "comment": "We thank you for confirming that the submission raises no substantive ethics concerns, and we adopt all four of your recommendations. The strengthened responsible-use wording below will appear verbatim in the new Limitations and Ethical Considerations section:\n\n(i) **Oversight.** HeatRAD must not be used for autonomous diagnosis or clinical decision-making without radiologist oversight and appropriate validation; it is a research prototype for assistive drafting, not a diagnostic device. (ii) **Overreliance.** A fluent, organ-attributed report may create over-trust even when routing is incorrect; any interface must communicate uncertainty explicitly, and the abstain mass is an internal routing variable rather than a calibrated clinical warning. (iii) **Subgroup and site-level generalization.** A retrospective patient-level sex/age subgroup analysis is now reported on CT-RATE age/sex metadata (spread 0.002 across sex, 0.012 across age), but it is single-benchmark and retrospective; prospective multi-institutional subgroup validation remains a prerequisite for deployment. (iv) **Prospective clinical evaluation.** A multi-reader study with source-CT review and blinded reports under a pre-specified, severity-weighted error taxonomy is required before any clinical use; the present evidence is lesion-level and report-level technical validation only.\n\nWe appreciate the concrete suggestions, which made the responsible-use statement measurably stronger."+ },+ "createdAt": "2026-07-29T11:00:07.854Z",+ "modifiedAt": "2026-11-19T16:48:14.213Z",+ "url": "https://openreview.net/forum?id=p124P8VSQH¬eId=w1F2t8fyyi",+ "license": "CC-BY-4.0"+}