FacePhys: State of the Heart Learning
Update NeurIPS 2026 submission ftGKpah4gM: 13 notes
@openreview[bot] · 2026-11-24 15:54 UTC · 0f49d39840b8 ·
reviews/openreview/ftgkpah4gm/notes/0farabffeh.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/0farabffeh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "0FArabffeh",+ "replyTo": "kd0z2ytNwn",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Both concerns resolved: (1) no TN train–test gap (RMA is optional, now quantified); (2) the number discrepancy is a protocol + band-pass difference — all baselines re-run under matched 5-fold, FacePhys still best (5.58).",+ "comment": "We thank the AC for the clear synthesis of the concerns and for the guidance that resolving them could move the paper toward acceptance. We have posted detailed per-reviewer responses with **new experiments**; below we summarize how each of the two meta-review concerns is now addressed.\n\n**Concern 1 — Architectural discrepancy in the Temporal Normalization (TN) module.**\nThere is **no train–test gap** in our reported numbers: both training and the streaming inference behind Table 3 use the **same** chunk-wise global least-squares detrending (Eq. 3). The Recursive Moving Average (RMA) is an *optional* $O(1)$-memory streaming mode, **not** the path that produced our results. We also now **quantify** the choice directly (UBFC, 15 s windowed HR-MAE): the RMA decay is a *learned* per-channel parameter ($\\\\alpha \\\\approx 0.97$), and across $\\\\alpha \\\\in [0.9, 0.99]$ the RMA (**0.94–1.15 BPM**) matches or beats the global-LSQ training path (**1.01 BPM**) — i.e. **switching train→inference causes no drop**. We will state both detrending paths explicitly in the revision.\n\n**Concern 2 — Comparison with prior numbers (MMPD 5.58 vs. RhythmMamba 3.16 / RhythmFormer 3.07; UBFC 0.46 vs. Contrast-Phys+ 0.21) and breadth of baselines.**\nThis is a **protocol difference, not a method gap**, and we have made it verifiable:\n\n- **Matched protocol.** Prior figures use the rPPG-Toolbox **single ~20% split**; we use **5-fold subject-independent CV over 100% of subjects** and **re-train + re-evaluate every baseline** under this identical protocol.\n- **Post-processing corrected.** Prompted by the reviewers, we found our original band-pass (0.5–3 Hz) was wider than RhythmMamba's (0.75–2.5 Hz) — unintentionally unfavourable to the baselines. We aligned each method to its own band and re-ran everything.\n- **Reconciliation.** Under matched 5-fold MMPD, **FacePhys 5.58** is best, vs. PhysMamba 6.22, PHASE-Net 6.61, RhythmMamba 7.57, PhysNet 8.13, PhysFormer 9.47. RhythmMamba's **best fold (3.54)** is close to its reported 3.16 — consistent with that number coming from an easy subset — while it degrades to **15.98** on the hardest fold, where FacePhys holds **9.55**. The UBFC 0.21-vs-0.46 gap is likewise the Dual-GAN 12-subject split vs. our all-42-subject CV, on a benchmark saturated **below the 3 BPM clinically-acceptable margin**.\n- **Cross-dataset sanity check.** Where there is *no split to choose*, our re-trained baselines reproduce the published band exactly (RhythmMamba **9.62 / 10.9**), confirming our pipeline is faithful — the discrepancy appears **only** in the intra-dataset (subject-split) setting.\n- **Broader baselines.** We added **PhysMamba** and **PHASE-Net (CVPR 2026)**, and moved the per-fold two-protocol table into the main text.\n\nWe believe **both meta-review concerns are now fully resolved**, and we have folded every change into the camera-ready plan (updated Table 3, added baselines, explicit dual-latency and detrending descriptions, released split files and scripts).\n\nWe would be glad to run **any additional analysis the AC or reviewers would find useful** — e.g., further baselines under the matched protocol, or additional subgroup breakdowns — and we welcome continued discussion. Thank you again for your time and for handling our submission."+ },+ "createdAt": "2026-07-30T14:50:54.247Z",+ "modifiedAt": "2026-11-19T16:54:07.677Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=0FArabffeh",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/7nw3e1vjkg.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/7nw3e1vjkg.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "7Nw3e1VJKG",+ "replyTo": "il1S1KfV5o",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Gentle reminder: responses posted — we welcome any follow-up before the discussion closes",+ "comment": "Dear Reviewer R9iW, thank you for the detailed review. We posted new experiments directly addressing each point: **HRV estimation**, the **MMPD/UBFC number discrepancy** (a protocol + band-pass difference, all baselines re-run under matched 5-fold), **implementation details**, and **skin-tone robustness**. We would sincerely welcome any further discussion."+ },+ "createdAt": "2026-07-31T01:13:55.711Z",+ "modifiedAt": "2026-11-19T16:54:07.589Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=7Nw3e1VJKG",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/aieblrp7gz.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/aieblrp7gz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "aIeBLrP7GZ",+ "replyTo": "50H5eybwYr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Kind check-in before discussion closes — thank you for reviewing our rebuttal",+ "comment": "With only 2.5 days left in the discussion period, we wanted to kindly check in to see if our rebuttal addressed your concerns. We believe this rebuttal has significantly strengthened the paper. Please let us know if there are any remaining concerns we can clarify before the discussion period closes."+ },+ "createdAt": "2026-08-02T01:00:55.512Z",+ "modifiedAt": "2026-11-19T16:54:07.371Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=aIeBLrP7GZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/azz0whildz.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/azz0whildz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Azz0WhiLDZ",+ "replyTo": "il1S1KfV5o",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer R9iW",+ "content": {+ "title": "Thank you for the rebuttal",+ "comment": "Thank you for your thorough response. My concerns have been largely addressed. I plan to reflect this in the score.\nPlease incorporate these changes into the new manuscript.\n\nRegarding the new table presented in W1/Q1, I believe the experiments were conducted using the same setup as PHASE-Net. Which results in the PHASE-Net paper can these findings be directly compared to? I noticed that the numbers differ from those in Table 1 of the PHASE-Net paper, so I would like to ask about the discrepancies between them."+ },+ "createdAt": "2026-08-02T05:21:50.299Z",+ "modifiedAt": "2026-11-19T16:54:07.312Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=Azz0WhiLDZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/h3oegtlmre.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/h3oegtlmre.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "h3OEgTlMrE",+ "replyTo": "50H5eybwYr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Gentle reminder: responses posted — we welcome any follow-up before the discussion closes",+ "comment": "Dear Reviewer 6VPv, thank you for your positive assessment. We posted responses with new experiments quantifying **RMA α-sensitivity** (no train→inference drop), the end-to-end **HR-latency** vs. FFT-window trade-off, and empirical SSM recovery from severe motion (~**0.9** s). We would welcome any follow-up before the discussion closes."+ },+ "createdAt": "2026-07-31T01:11:38.408Z",+ "modifiedAt": "2026-11-19T16:54:07.673Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=h3OEgTlMrE",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/kd0z2ytnwn.json modified
+++ b/reviews/openreview/ftgkpah4gm/notes/kd0z2ytnwn.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair yENU","content": {- "metareview": "The authors propose FacePhys, a memory-efficient remote photoplethysmography (rPPG) algorithm designed for real-time inference on edge devices. To overcome the quadratic complexity of Transformers and the limited receptive fields of CNNs, FacePhys is built upon a Linear Time-Invariant (LTI) state space model (SSM) featuring temporal-spatial duality. A key innovation is the use of complex diagonal entries in the state transition matrix to explicitly model the periodic nature of physiological signals. Evaluated across five benchmark datasets, FacePhys achieves state-of-the-art performance in both intra-dataset and cross-dataset settings.\n\nThis work received borderline scores initially with major concerns centered around:\n* Architectural discrepancy in the Temporal Normalization module.\n* Comparison with conventional methods in the experimental results. For example, in Table 3, it is stated that FacePhys achieves the lowest MAE of 5.58 for MMPD; however, the RhythmMamba paper reports that RhythmFormer achieved 3.07 and RhythmMamba achieved 3.16. Furthermore, while it is stated that FacePhys achieves the lowest MAE of 0.46 on UBFC-rPPG, Contrast-Phys+ achieves 0.21. An explanation is needed regarding the discrepancy with the performance reported in prior papers. Additionally, it is possible that performance comparisons with a sufficiently broad range of prior papers have not been conducted.\n\nThe rebuttal addressed these concerns and provided additional baseline comparisons that further resolve initial concerns around evaluation. The review panel agreed to recommend this paper for acceptance."+ "metareview": "The authors propose FacePhys, a memory-efficient remote photoplethysmography (rPPG) algorithm designed for real-time inference on edge devices. To overcome the quadratic complexity of Transformers and the limited receptive fields of CNNs, FacePhys is built upon a Linear Time-Invariant (LTI) state space model (SSM) featuring temporal-spatial duality. A key innovation is the use of complex diagonal entries in the state transition matrix to explicitly model the periodic nature of physiological signals. Evaluated across five benchmark datasets, FacePhys achieves state-of-the-art performance in both intra-dataset and cross-dataset settings.\n\nThis work received borderline scores initially with major concerns centered around:\n* Architectural discrepancy in the Temporal Normalization module.\n* Comparison with conventional methods in the experimental results. For example, in Table 3, it is stated that FacePhys achieves the lowest MAE of 5.58 for MMPD; however, the RhythmMamba paper reports that RhythmFormer achieved 3.07 and RhythmMamba achieved 3.16. Furthermore, while it is stated that FacePhys achieves the lowest MAE of 0.46 on UBFC-rPPG, Contrast-Phys+ achieves 0.21. An explanation is needed regarding the discrepancy with the performance reported in prior papers. Additionally, it is possible that performance comparisons with a sufficiently broad range of prior papers have not been conducted.\n\nThe rebuttal addressed these concerns and provided additional baseline comparisons that further resolve initial concerns around evaluation. The review panel agreed to recommend this paper for acceptance.",+ "final_justification": "See metareview."},"createdAt": "2026-07-22T18:23:37.256Z",- "modifiedAt": "2026-11-18T15:19:12.344Z",+ "modifiedAt": "2026-11-19T04:59:32.135Z","url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=kd0z2ytNwn","license": "CC-BY-4.0"}
reviews/openreview/ftgkpah4gm/notes/krevrrcsn9.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/krevrrcsn9.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "KREVRrcsn9",+ "replyTo": "LfDzAF0359",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Gentle reminder: responses posted — we welcome any follow-up before the discussion closes",+ "comment": "Dear Reviewer CpUx, thank you for your constructive review. We posted new results: a **VitalVideo subgroup analysis** (skin tone / sex / motion), a matched-protocol **PHASE-Net comparison** (FacePhys best on HR and HRV), and a concrete clinical-validation plan. We would greatly value any further feedback."+ },+ "createdAt": "2026-07-31T01:12:51.637Z",+ "modifiedAt": "2026-11-19T16:54:07.586Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=KREVRrcsn9",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/kxpfdnc3vh.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/kxpfdnc3vh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "kxpFdnc3vh",+ "replyTo": "z3G98HjXWp",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thanks for the reply — clarifying the robustness of FacePhys",+ "comment": "**W4/Q4 (follow-up) · Is FacePhys more robust than the other methods?**\n\nYes. We extended the subgroup analysis to the baselines under identical RLAP training on the same 1783 VitalVideo clips. HR-MAE (BPM, $\\downarrow$):\n\n| Method | Fitz. 1–2 | Fitz. 3–4 | Fitz. 5–6 |\n| :--- | :---: | :---: | :---: |\n| **FacePhys** | **0.54** | **0.86** | **3.82** |\n| PhysFormer | 0.99 | 1.20 | 6.68 |\n| RhythmMamba | 1.07 | 1.74 | 8.35 |\n| PhysMamba | 2.43 | 2.17 | 6.59 |\n| TS-CAN | 2.91 | 2.82 | 7.75 |\n| EfficientPhys | 5.98 | 4.86 | 9.68 |\n\nFacePhys attains the lowest error in **every** skin-tone bin, and remains the best method on the darkest one. We stress that this is a matter of degree, not immunity: *every* method degrades on Fitzpatrick 5–6, and the cause is physical rather than architectural — in our data the mean pulsatile SNR of the Fitzpatrick 5–6 clips is **3.4 dB below** that of the Fitzpatrick 1–2 clips ($-5.40$ vs $-2.04$ dB), so the input signal itself is weaker before any model is applied.\n\nThis is corroborated on **MMPD mentioned on W2/Q2, which is itself a Fitzpatrick 3–6 population**. Under the matched 5-fold intra-dataset protocol, FacePhys obtains the **best 5-fold average HR-MAE (5.58 BPM)**, is best on **3 of 5 folds**, and degrades **least on the hardest fold** (9.55 BPM, while the competing methods rise to 10.2–16.0); it also outperforms the concurrent **PHASE-Net (6.61)**. Across both a Fitzpatrick-labelled benchmark and a benchmark composed entirely of darker-skin subjects, FacePhys is therefore the most robust of the compared methods — while skin-tone fairness remains a limitation we commit to improving through targeted data collection and SNR-aware training."+ },+ "createdAt": "2026-08-03T15:19:57.715Z",+ "modifiedAt": "2026-11-19T16:54:07.410Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=kxpFdnc3vh",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/lvogbtihbh.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/lvogbtihbh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "lvOgbtiHBH",+ "replyTo": "il1S1KfV5o",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Kind check-in before discussion closes — thank you for reviewing our rebuttal",+ "comment": "With only 2.5 days left in the discussion period, we wanted to kindly check in to see if our rebuttal addressed your concerns. We believe this rebuttal has significantly strengthened the paper. Please let us know if there are any remaining concerns we can clarify before the discussion period closes."+ },+ "createdAt": "2026-08-02T01:00:04.409Z",+ "modifiedAt": "2026-11-19T16:54:07.585Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=lvOgbtiHBH",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/qori5t6mld.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/qori5t6mld.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QorI5T6mLd",+ "replyTo": "6ZN1g9irB2",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6VPv",+ "content": {+ "comment": "Thank you for the detailed rebuttal and the additional experiments provided to validate the approach. The authors have successfully addressed all my comments, which were primarily requests for clarification. I am satisfied with the responses and will maintain my initial positive rating, as my overall assessment of the paper's contribution remains unchanged."+ },+ "createdAt": "2026-08-02T16:30:41.651Z",+ "modifiedAt": "2026-11-19T16:54:07.331Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=QorI5T6mLd",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/rgqr6x6vjq.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/rgqr6x6vjq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "rGqr6X6VjQ",+ "replyTo": "mZZZkZessv",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer CpUx",+ "content": {+ "comment": "Thank you for your response and additional clarification. I have carefully considered your comments and appreciate your efforts. After consideration, I will maintain my original score. I wish you all the best with your research and good luck with this paper."+ },+ "createdAt": "2026-07-31T15:15:00.151Z",+ "modifiedAt": "2026-11-19T16:54:07.409Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=rGqr6X6VjQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/wqpmp5dzzx.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/wqpmp5dzzx.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "WQPmp5dZzx",+ "replyTo": "Azz0WhiLDZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thanks for the reply — clarifying the protocol of the PHASE-Net comparison (W1/Q1)",+ "comment": "We thank the reviewer for considering raising the score and for this careful follow-up — it is a fair point and we want to be fully transparent.\n\n**Which PHASE-Net number this compares to.** The reviewer is correct: our table is *not* directly comparable to Table 1 of the PHASE-Net paper. Their Table 1 (UBFC-rPPG MAE **0.15 bpm**) is an **intra-dataset** result produced with **their own preprocessing and cached data** (HC face detector, large-box ×1.5 crop, their exact train/test file lists). Our table used PHASE-Net's **released checkpoint run through our unified pipeline on our own face crops**, on the same 12 held-out subjects (0.72–1.0 split). So the difference is a **preprocessing / input-distribution gap, not a re-implementation of their method** — rPPG accuracy is highly sensitive to crop geometry, so we could not reproduce their exact number.\n\nWe will therefore **cite PHASE-Net's results as published** under their own protocol, and only compare methods we can run end-to-end under one identical pipeline. On this saturated benchmark, recent methods (PHASE-Net 0.15, FacePhys 0.46) are all far below the 3 bpm clinical margin, so we are cautious about ranking sub-1-bpm differences on 12 subjects. FacePhys's contribution is **orthogonal** to single-split peak accuracy: true per-frame streaming, O(1) memory (3.6 MB), sub-10 ms/frame, and stability under cross-dataset shift. We are glad to add any further comparison the reviewer would find useful."+ },+ "createdAt": "2026-08-02T13:18:36.166Z",+ "modifiedAt": "2026-11-19T16:54:07.310Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=WQPmp5dZzx",+ "license": "CC-BY-4.0"+}
reviews/openreview/ftgkpah4gm/notes/z3g98hjxwp.json added
+++ b/reviews/openreview/ftgkpah4gm/notes/z3g98hjxwp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "z3G98HjXWp",+ "replyTo": "WQPmp5dZzx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer R9iW",+ "content": {+ "comment": "Thank you for your response.\n\nRegarding the robustness analysis across skin tones in W4/Q4, is FacePhys more robust than the other methods?"+ },+ "createdAt": "2026-08-03T00:57:09.220Z",+ "modifiedAt": "2026-11-19T16:54:07.324Z",+ "url": "https://openreview.net/forum?id=ftGKpah4gM¬eId=z3G98HjXWp",+ "license": "CC-BY-4.0"+}