potentialpaper

Equivariant Spherical Transformer for Efficient Molecular Modeling

Update NeurIPS 2026 submission 5i7KqZASE3: 13 notes

@openreview[bot] · 2026-11-24 15:46 UTC · 021089f4de7b ·

Evidence

reviews/openreview/5i7kqzase3/notes/4atr9k4r4o.json added

+++ b/reviews/openreview/5i7kqzase3/notes/4atr9k4r4o.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "4atr9k4r4o",
+ "replyTo": "YlJuhOzjxT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Direct SCN Ablation Further Confirms the Contribution of EST",
+ "comment": "Fortunately, we were also able to complete a direct **SCN-based OC20-S2EF-200K experiment** before the discussion period closes. This experiment provides a particularly direct validation complementary to our earlier parameter-matched EquiformerV2 ablation.\n\nSpecifically, we use the original SCN implementation and replace only its orientation-wise grid MLP (S2Activation) with EST. All backbone and training settings are kept unchanged: lmax=3, 6 interaction blocks, 256 hidden channels, 64 spherical channels, 20 neighbors, a 6 Å cutoff, and the same 60k-step training budget. The parameter count increases moderately from 3.933M to 4.282M (+8.9%).\n\nFor broader context, we also include the OC20-S2EF-200K baselines reported in the Open Catalyst Project MODELS.md(https://github.com/Marimuda/ocp/blob/master/MODELS.md):\n\n| Model | Energy MAE ↓ | Force MAE ↓ | Force cosine ↑ | Force magnitude error ↓ |\n| -------------- | -----------: | ----------: | -------------: | ----------------------: |\n| CGCNN* | – | 0.0800 | – | – |\n| SchNet* | – | 0.0743 | – | – |\n| DimeNet* | – | 0.0693 | – | – |\n| DimeNet++* | – | 0.0741 | – | – |\n| SCN-original | **0.54533** | 0.05172 | 0.26900 | 0.08147 |\n| **SCN-EST** | 0.56208 | **0.04931** | **0.29511** | **0.07597** |\n\n\nReplacing S2Activation with EST reduces force MAE by **4.7%**, improves force cosine similarity by **9.7%**, and reduces force magnitude error by **6.7%**. We also observe a slight increase in energy MAE (+3.1%), suggesting that the gain is concentrated on force modeling.\n\nTogether with our earlier ablation in EquiformerV2, we believe this direct SCN experiment further isolates the contribution of EST: the spherical representation and overall backbone remain unchanged, while introducing cross-orientation interaction consistently improves the force-related metrics. We will include this result and clarify this positioning relative to SCN/eSCN in the revision."
+ },
+ "createdAt": "2026-08-04T06:08:05.633Z",
+ "modifiedAt": "2026-11-19T17:17:11.741Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=4atr9k4r4o",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/4pnsr8xzcn.json modified

+++ b/reviews/openreview/5i7kqzase3/notes/4pnsr8xzcn.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair 7vQd",
"content": {
- "metareview": "I read the authors' response, the discussion and the revised claims, and I went back through the paper.\n\n**Summary.** EST is a plug-in module for SO(3)-equivariant networks. Steerable spherical-harmonic features on a node are mapped by a spherical Fourier transform onto a finite set of sampled orientations, Transformer self-attention runs across those orientations, and the result is mapped back. The attention is the design point: prior spatial-domain models such as SCN and eSCN process each sampled orientation independently through a pointwise MLP, whereas EST lets the orientations interact. Two components make that workable. A relative orientation embedding supplies positional information without the conventional positional encoding that would break equivariance, and Fibonacci-lattice sampling keeps the sample set near-uniform so that the departure from exact equivariance stays small. The claim is that attention across orientations captures angular correlations beyond the degree bound limiting Clebsch-Gordan tensor products, raising expressiveness without raising the maximum degree. EST is inserted into the update blocks of Equiformer, EquiformerV2 and GotenNet and evaluated on OC20 (S2EF, IS2RE), MPtrj and QM9, with state-of-the-art results reported and small EST models matching or beating larger baselines and baselines trained on extra data. The reviewers describe the contribution the same way, but had disagreements over how much of the gain the attention itself explains.\n\n**Strengths.** The paper addresses a real challenge: Clebsch-Gordan tensor products are expressiveness-bounded by the maximum degree, and raising the degree is expensive. The module is a genuine plug-in, dropping into the update block of several existing architectures, so others can adopt it without changing models. The empirical work is broad, validated on OC20 S2EF, IS2RE-OOD and MPtrj. The authors also measure the point where their own theory stops holding, instead of leaving it unexamined. Reviewer RgUU rated significance and originality excellent, and I agree.\n\n**Weaknesses.** Memory might be a problem: attention is quadratic in the number of sampled orientations, peak memory on the QM9 setting grows from 2538 MiB at 128 samples to 12424 MiB at 512, and the MPtrj global batch size was halved partly for this reason. The gains are uneven, small or absent on several QM9 energy targets and largely gone on the deepest GotenNet variant; the authors attribute this to QM9 saturation plus equivariance error accumulating with depth, which is consistent with their depth ablation but is offered after the observation rather than tested. Claim 3.2 is intuition supported by a universal-approximation argument and fitting experiments, not a proof, which is fine once labeled as such. Presentation is the weakest dimension: clarity drew the lowest scores, the appendix mixes unrelated material, and the rebuttal added a great deal that now needs integrating rather than appending. For the direct force head, Jacobian asymmetry rises relative to the baseline (0.258 to 0.464), so non-conservativity is measurably worse, though both models stay inside the range the reported tasks require.\n\n**Author response and discussion with the reviewers.** My initial meta-review found no critical flaws and put the decision on one question: whether the novelty and the size of the improvements justify acceptance. The rebuttal was aimed at that question and, in my judgment, succeeded.\n\nThe central objection was Reviewer ymhd's, that EST is an incremental variant of SCN/eSCN-style spherical-channel processing and that the OC20 gains conflate backbone, parameter count, depth and training setup. The authors ran the experiment the objection called for. In the original SCN implementation on OC20-S2EF-200K they replace only the orientation-wise grid MLP, holding maximum degree, blocks, channels, neighbors, cutoff and training budget fixed, at an 8.9% parameter increase: force MAE improves from 0.0517 to 0.0493, force cosine from 0.269 to 0.295 and force magnitude error from 0.0815 to 0.0760, with energy MAE slightly worse. A parameter-matched EquiformerV2 experiment on QM9, replacing only S2Activation, points the same way. That attributes the gain to cross-orientation interaction rather than to the spherical projection, which SCN already had. Reviewer ymhd confirmed the additions substantially addressed their main concerns, stated that none remain, and moved to the accept side, asking that the approximate-equivariance limitation be put more plainly.\n\nThe second objection, that finite sampling leaves equivariance approximate and that this matters for interatomic potentials, was answered with force-level equivariance error against depth and resolution, NVE drift on MPtrj and MD17, Jacobian-asymmetry conservativity, relaxation convergence, and finite-difference Hessians showing no spurious imaginary modes. Errors are small and shrink with resolution, and the physical checks track the baselines.\n\nI will add my own assessment here, since this was the main reason a reviewer initially leaned reject. I do not regard approximate equivariance as a defect. Other work in the literature has shown that compromising exact equivariance, whether through numerically approximate constructions or deliberate symmetry breaking, can match or improve on strictly equivariant designs, and the trade-off against expressiveness is by now a recognized design axis rather than a flaw. What matters is that the departure is measured and disclosed, which the authors now do. The paper would be stronger for situating its choice in that literature instead of treating the finite-sampling gap only as a shortcoming of its own construction.\n\nReviewer RgUU's concerns were about precision: Theorem 3.1 is stated for a finite point set but holds only for a closed one, and Claim 3.2's status was unclear. Both were clarified, uniformity was quantified with three standard sphere-sampling metrics that put the Fibonacci lattice and its optimized variant ahead of the e3nn grid at every sample count, and a comparison with Cartesian-tensor approaches was supplied; that reviewer raised their score. Reviewer WuCQ's concerns on memory, sampling density against accuracy, deeper models and larger systems, and applicability beyond molecules were answered with memory measurements, a resolution sweep and an LJ13 experiment, and the reviewer confirmed they were largely addressed while recording memory overhead as a limitation.\n\nAll three reviewers now sit on the accept side and none holds an unresolved major concern.\n\n**Most important reasons for the decision.** The novelty question is settled by a controlled experiment instead of by argument: swapping only the orientation-wise MLP inside SCN, everything else fixed, improves the force metrics, which isolates the mechanism the paper is proposing. The effect is not limited to one benchmark or one host model, and the module is cheap enough in compute, if not in memory, for others to adopt. The remaining weaknesses are memory cost, uneven gains on saturated benchmarks, and presentation. All three are measured or fixable, and none of them affects whether the method works.\n\n**Recommendations for the camera-ready.** The authors committed to most of the following in the discussion. I am recording it so it does not get lost.\n\n1. Revise wording that implies strict equivariance, state Theorem 3.1 for the closed sampling set it requires, and label Claim 3.2 as unproven intuition supported by the approximation argument and experiments in Appendix B.2.\n2. Bring the rebuttal evidence into the paper: both controlled ablations, the sampling-uniformity metrics, the memory numbers, and the accuracy, equivariance, expressiveness and memory trade-off with the sampling-resolution guidance.\n3. Position the method relative to SCN/eSCN and to Cartesian-tensor approaches, and situate the choice to relax exact equivariance in the existing literature on doing so.\n4. State the attenuated gains on deeper backbones as a limitation with the saturation explanation from the rebuttal, reorganize the appendix, and condense the tangential mixture-of-experts background."
+ "metareview": "I read the authors' response, the discussion and the revised claims, and I went back through the paper.\n\n**Summary.** EST is a plug-in module for SO(3)-equivariant networks. Steerable spherical-harmonic features on a node are mapped by a spherical Fourier transform onto a finite set of sampled orientations, Transformer self-attention runs across those orientations, and the result is mapped back. The attention is the design point: prior spatial-domain models such as SCN and eSCN process each sampled orientation independently through a pointwise MLP, whereas EST lets the orientations interact. Two components make that workable. A relative orientation embedding supplies positional information without the conventional positional encoding that would break equivariance, and Fibonacci-lattice sampling keeps the sample set near-uniform so that the departure from exact equivariance stays small. The claim is that attention across orientations captures angular correlations beyond the degree bound limiting Clebsch-Gordan tensor products, raising expressiveness without raising the maximum degree. EST is inserted into the update blocks of Equiformer, EquiformerV2 and GotenNet and evaluated on OC20 (S2EF, IS2RE), MPtrj and QM9, with state-of-the-art results reported and small EST models matching or beating larger baselines and baselines trained on extra data. The reviewers describe the contribution the same way, but had disagreements over how much of the gain the attention itself explains.\n\n**Strengths.** The paper addresses a real challenge: Clebsch-Gordan tensor products are expressiveness-bounded by the maximum degree, and raising the degree is expensive. The module is a genuine plug-in, dropping into the update block of several existing architectures, so others can adopt it without changing models. The empirical work is broad, validated on OC20 S2EF, IS2RE-OOD and MPtrj. The authors also measure the point where their own theory stops holding, instead of leaving it unexamined. Reviewer RgUU rated significance and originality excellent, and I agree.\n\n**Weaknesses.** Memory might be a problem: attention is quadratic in the number of sampled orientations, peak memory on the QM9 setting grows from 2538 MiB at 128 samples to 12424 MiB at 512, and the MPtrj global batch size was halved partly for this reason. The gains are uneven, small or absent on several QM9 energy targets and largely gone on the deepest GotenNet variant; the authors attribute this to QM9 saturation plus equivariance error accumulating with depth, which is consistent with their depth ablation but is offered after the observation rather than tested. Claim 3.2 is intuition supported by a universal-approximation argument and fitting experiments, not a proof, which is fine once labeled as such. Presentation is the weakest dimension: clarity drew the lowest scores, the appendix mixes unrelated material, and the rebuttal added a great deal that now needs integrating rather than appending. For the direct force head, Jacobian asymmetry rises relative to the baseline (0.258 to 0.464), so non-conservativity is measurably worse, though both models stay inside the range the reported tasks require.\n\n**Author response and discussion with the reviewers.** My initial meta-review found no critical flaws and put the decision on one question: whether the novelty and the size of the improvements justify acceptance. The rebuttal was aimed at that question and, in my judgment, succeeded.\n\nThe central objection was Reviewer ymhd's, that EST is an incremental variant of SCN/eSCN-style spherical-channel processing and that the OC20 gains conflate backbone, parameter count, depth and training setup. The authors ran the experiment the objection called for. In the original SCN implementation on OC20-S2EF-200K they replace only the orientation-wise grid MLP, holding maximum degree, blocks, channels, neighbors, cutoff and training budget fixed, at an 8.9% parameter increase: force MAE improves from 0.0517 to 0.0493, force cosine from 0.269 to 0.295 and force magnitude error from 0.0815 to 0.0760, with energy MAE slightly worse. A parameter-matched EquiformerV2 experiment on QM9, replacing only S2Activation, points the same way. That attributes the gain to cross-orientation interaction rather than to the spherical projection, which SCN already had. Reviewer ymhd confirmed the additions substantially addressed their main concerns, stated that none remain, and moved to the accept side, asking that the approximate-equivariance limitation be put more plainly.\n\nThe second objection, that finite sampling leaves equivariance approximate and that this matters for interatomic potentials, was answered with force-level equivariance error against depth and resolution, NVE drift on MPtrj and MD17, Jacobian-asymmetry conservativity, relaxation convergence, and finite-difference Hessians showing no spurious imaginary modes. Errors are small and shrink with resolution, and the physical checks track the baselines.\n\nI will add my own assessment here, since this was the main reason a reviewer initially leaned reject. I do not regard approximate equivariance as a defect. Other work in the literature has shown that compromising exact equivariance, whether through numerically approximate constructions or deliberate symmetry breaking, can match or improve on strictly equivariant designs, and the trade-off against expressiveness is by now a recognized design axis rather than a flaw. What matters is that the departure is measured and disclosed, which the authors now do. The paper would be stronger for situating its choice in that literature instead of treating the finite-sampling gap only as a shortcoming of its own construction.\n\nReviewer RgUU's concerns were about precision: Theorem 3.1 is stated for a finite point set but holds only for a closed one, and Claim 3.2's status was unclear. Both were clarified, uniformity was quantified with three standard sphere-sampling metrics that put the Fibonacci lattice and its optimized variant ahead of the e3nn grid at every sample count, and a comparison with Cartesian-tensor approaches was supplied; that reviewer raised their score. Reviewer WuCQ's concerns on memory, sampling density against accuracy, deeper models and larger systems, and applicability beyond molecules were answered with memory measurements, a resolution sweep and an LJ13 experiment, and the reviewer confirmed they were largely addressed while recording memory overhead as a limitation.\n\nAll three reviewers now sit on the accept side and none holds an unresolved major concern.\n\n**Most important reasons for the decision.** The novelty question is settled by a controlled experiment instead of by argument: swapping only the orientation-wise MLP inside SCN, everything else fixed, improves the force metrics, which isolates the mechanism the paper is proposing. The effect is not limited to one benchmark or one host model, and the module is cheap enough in compute, if not in memory, for others to adopt. The remaining weaknesses are memory cost, uneven gains on saturated benchmarks, and presentation. All three are measured or fixable, and none of them affects whether the method works.\n\n**Recommendations for the camera-ready.** The authors committed to most of the following in the discussion. I am recording it so it does not get lost.\n\n1. Revise wording that implies strict equivariance, state Theorem 3.1 for the closed sampling set it requires, and label Claim 3.2 as unproven intuition supported by the approximation argument and experiments in Appendix B.2.\n2. Bring the rebuttal evidence into the paper: both controlled ablations, the sampling-uniformity metrics, the memory numbers, and the accuracy, equivariance, expressiveness and memory trade-off with the sampling-resolution guidance.\n3. Position the method relative to SCN/eSCN and to Cartesian-tensor approaches, and situate the choice to relax exact equivariance in the existing literature on doing so.\n4. State the attenuated gains on deeper backbones as a limitation with the saturation explanation from the rebuttal, reorganize the appendix, and condense the tangential mixture-of-experts background.",
+ "final_justification": "The meta-review above has been rewritten as the final meta-review. It covers the author response, the discussion with the reviewers, and the justification for the recommendation."
},
"createdAt": "2026-07-17T16:38:13.627Z",
- "modifiedAt": "2026-11-18T15:19:16.567Z",
+ "modifiedAt": "2026-11-19T04:59:36.115Z",
"url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=4PnsR8XZCn",
"license": "CC-BY-4.0"
}

reviews/openreview/5i7kqzase3/notes/bzeqiqnclc.json added

+++ b/reviews/openreview/5i7kqzase3/notes/bzeqiqnclc.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "bZEqIqncLC",
+ "replyTo": "YlJuhOzjxT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer ymhd,\n\nWe sincerely thank you for your feedback and for recognizing our work. We also appreciate your constructive suggestions. In the future revised version, we will include a discussion in the appendix on the trade-offs among accuracy, equivariance, expressivity, and memory usage, incorporating most of the arguments from our first-round rebuttal (W1 and Q1, W2 and Q2).\n\nIn brief, previous work has shown that exactly equivariant models may have limited expressiveness, which can hinder their ability to model complex molecular systems. Increasing the maximum degree can alleviate this issue, but it leads to substantial increases in memory consumption and computational cost, thereby affecting downstream applications. Introducing appropriately unconstrained learnable modules may break equivariance to some extent, but can effectively improve expressiveness with simliar computational cost. The learning module in EST is derived from a theory that is exactly equivariant in an idealized setting, which enables EST to already exhibit strong equivariance under practical setting. In addition, we have provided multiple theoretical and empirical analyses showing that the Transformer in the spatial domain can achieve higher expressivity than conventional Clebsch–Gordan tensor-product (CG-TP) modules. This allows EST to attain a better balance in downstream tasks, thereby improving generalization accuracy.\n\nMoreover, memory usage depends on the number of sampling points in the spatial domain and the maximum degree. The number of sampling points affects equivariance, while the maximum degree affects expressivity. Therefore, users who wish to enhance a particular capability of the model for a specific task should also take memory constraints into account. In the paper and in our rebuttal, we provide an empirical configuration for the sampling points: it is sufficient to set the number of sampling points to $\\max(64, \\text{the Nyquist sampling rate})$. We set the lower bound to 64 to avoid an excessive loss of equivariance. When data are abundant, increasing the number of sampling points yields only marginal gains. When data are scarce, the number of sampling points can be moderately increased beyond this configuration.\n\nIn addition, following your suggestion, we will avoid describing EST as exactly equivariant. In the original manuscript, immediately after introducing the equivariance theory (Theorem 3.1), we pointed out that finite sampling breaks equivariance. In the revised version, we will carefully check the statements regarding EST’s equivariance prior to introducing the theory and avoid claims of exact equivariance.\n\nFinally, we thank you again for the time and effort you have devoted to reviewing our paper. We will follow the suggestions you raised in the first and second rounds, which will make our manuscript more rigorous.\n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-04T02:46:55.433Z",
+ "modifiedAt": "2026-11-19T17:17:11.848Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=bZEqIqncLC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/d9cznne1w2.json added

+++ b/reviews/openreview/5i7kqzase3/notes/d9cznne1w2.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "D9czNnE1w2",
+ "replyTo": "4uqgLq3nUS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "During the first round of the rebuttal, we added the implementation and report of the supplementary ablation studies to the anonymous repository. However, there appears to be a bug in the anonymous repository: **clicking directly on the directory link we provided does not display the files within it. Instead, one must navigate to another directory and then click back to view the contents.**\n\n**We sincerely apologize for this inconvenience. To facilitate your review, we are providing the direct link to the experiment report below:**\n\n[LJ13 experiments report](https://anonymous.4open.science/r/EST-F4FF/rebuttal/lj13_nbody_experiment/report.md)"
+ },
+ "createdAt": "2026-07-29T05:45:24.907Z",
+ "modifiedAt": "2026-11-19T17:17:12.097Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=D9czNnE1w2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/ftqg3zmrk2.json added

+++ b/reviews/openreview/5i7kqzase3/notes/ftqg3zmrk2.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "FTQG3zMRk2",
+ "replyTo": "GlMi9VpH3l",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you very much for your thoughtful feedback and for acknowledging our additional clarifications. We truly appreciate your time and constructive suggestions, which helped us improve the presentation of revised version.\n\nWe noticed that the current score shown in the system remains 4, while your comment indicates that you would raise it to 5. We understand this may simply be a system update issue, but we would appreciate it if you could kindly verify the score when convenient.\n\nThank you again for your valuable comments and suggestions."
+ },
+ "createdAt": "2026-08-02T04:03:01.243Z",
+ "modifiedAt": "2026-11-19T17:17:12.106Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=FTQG3zMRk2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/gouqwlydbn.json added

+++ b/reviews/openreview/5i7kqzase3/notes/gouqwlydbn.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "goUQWLyDBn",
+ "replyTo": "qLzr0BvZC5",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer RgUU",
+ "content": {
+ "title": "Reponse to the Rebuttal",
+ "comment": "Q1: Thank you for this investigation, I find these results convincing. Since all 3 metrics perform similarly in most cases, my recommendation would be to pick your favorite one and reference it when you are discussing this idea. Or maybe put the table in the Appendix.\n\nQ2: I see, so this is an argument about in the limit of feature dimension and sampling points, you can approximate all the functions. But you don't want to be explicit about these quantities or their relations to each other. With that context, \"tends to\" makes some sense because it is a limiting argument that it is tending towards. But without that context I just find the phrasing confusing, so yes I would find some other way to say that.\n\nQ3: Thank you, I don't have a problem with you presenting some intuition around the methods and backing them up with empirical results, rather than proofs. It just needs to be clear that this is the case.\n\nQ4: Thank you, it may be beneficial to include some parts of this comparison in your paper for readers who are more familiar with those methods.\n\nQ5: This sounds reasonable.\n\nThank you to the authors for addressing each of my concerns. I will be raising my score to a 5."
+ },
+ "createdAt": "2026-08-01T13:12:44.267Z",
+ "modifiedAt": "2026-11-19T17:17:12.096Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=goUQWLyDBn",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/mtvvh4kjcb.json added

+++ b/reviews/openreview/5i7kqzase3/notes/mtvvh4kjcb.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "MtVvH4kJCb",
+ "replyTo": "xd2PcTVX3H",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer WuCQ,\n\nThank you for your valuable review. In the first-round rebuttal, we addressed all of the concerns you raised. **Briefly, 1. we provided additional ablation results on memory usage, as well as experiments examining the effect of different sampling strategies on performance. 2. We also included a new equivariance analysis. We would like to emphasize that the trade-off between equivariance and expressiveness is one of the central concerns of this work. In our response to Reviewer ymhd (W1 and Q1), we discussed in detail the theoretical motivation for relaxing equivariance in order to improve expressiveness. If you are interested, we welcome you to refer to that discussion. 3. Finally, we greatly appreciate your recognition of the generality of EST on Euclidean data. We have additionally conducted experiments on LJ13, which further confirm this point.**\n\nThank you again for the time and effort you have devoted to reviewing our paper. **As the discussion period is drawing to a close, we would sincerely like to know whether you have any remaining concerns.**\n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-04T02:30:20.882Z",
+ "modifiedAt": "2026-11-19T17:17:11.858Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=MtVvH4kJCb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/o7ykuz8v1r.json added

+++ b/reviews/openreview/5i7kqzase3/notes/o7ykuz8v1r.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "o7YKuZ8V1R",
+ "replyTo": "GlMi9VpH3l",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer RgUU\n\nAs the discussion phase is drawing to a close, we would like to take this final opportunity to express our sincere gratitude for your time and insightful feedback. Your thoughtful comments have been invaluable in improving the quality of our manuscript, and we will follow your suggestions regarding Q1, Q2, Q3, and Q4, and rigorously refine our statements accordingly. \n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-04T02:54:31.395Z",
+ "modifiedAt": "2026-11-19T17:17:11.795Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=o7YKuZ8V1R",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/qlzr0bvzc5.json added

+++ b/reviews/openreview/5i7kqzase3/notes/qlzr0bvzc5.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "qLzr0BvZC5",
+ "replyTo": "GlMi9VpH3l",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "During the first round of the rebuttal, we added the implementation and report of the supplementary ablation studies to the anonymous repository. However, there appears to be a bug in the anonymous repository: clicking directly on the directory link we provided does not display the files within it. Instead, one must navigate to another directory and then click back to view the contents.\n\nWe sincerely apologize for this inconvenience. To facilitate your review, we are providing the direct link to the experiment report below:\n\n[uniformity test report](https://anonymous.4open.science/r/EST-F4FF/rebuttal/uniformity/report.md)"
+ },
+ "createdAt": "2026-07-29T05:45:55.221Z",
+ "modifiedAt": "2026-11-19T17:17:12.028Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=qLzr0BvZC5",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/v198rpq1nw.json added

+++ b/reviews/openreview/5i7kqzase3/notes/v198rpq1nw.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "V198rPq1NW",
+ "replyTo": "YlJuhOzjxT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer ymhd",
+ "content": {
+ "comment": "The authors have substantially addressed my main concerns. In particular, the added controlled comparison replacing spherical operations, force-level equivariance analysis, physical validity tests, and sampling-resolution ablations provide much stronger evidence that EST is not merely an incremental spherical-domain modification. The clarification that the key contribution lies in cross-orientation interaction rather than the spherical projection itself is helpful. However, finite-sampling equivariance remains approximate by design, and the method still introduces a non-trivial accuracy–equivariance–memory trade-off. I encourage the authors to make this limitation clearer and avoid overstating strict equivariance guarantees. Overall, I find the revised submission significantly improved compared with the original version, and I would be willing to raise my score from borderline reject to borderline accept. I have no remaining major concerns."
+ },
+ "createdAt": "2026-08-02T06:50:26.853Z",
+ "modifiedAt": "2026-11-19T17:17:12.099Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=V198rPq1NW",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/vntrgutb3n.json added

+++ b/reviews/openreview/5i7kqzase3/notes/vntrgutb3n.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "VNtrGUtB3N",
+ "replyTo": "YlJuhOzjxT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "During the first round of the rebuttal, we added the implementation and report of the supplementary ablation studies to the anonymous repository. However, there appears to be a bug in the anonymous repository: clicking directly on the directory link we provided does not display the files within it. Instead, one must navigate to another directory and then click back to view the contents.\n\nWe sincerely apologize for this inconvenience. To facilitate your review, we are providing the direct link to the experiment report below:\n\n[expressiveness report for novelty](https://anonymous.4open.science/r/EST-F4FF/rebuttal/expressiveness/report.md)\n\n[force-level equivariance report](https://anonymous.4open.science/r/EST-F4FF/rebuttal/force_equivariance/report.md)\n\n[physical validity test report](https://anonymous.4open.science/r/EST-F4FF/rebuttal/physical_validity_test/report.md)"
+ },
+ "createdAt": "2026-07-29T05:46:10.566Z",
+ "modifiedAt": "2026-11-19T17:17:11.950Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=VNtrGUtB3N",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/vzua9dziyq.json added

+++ b/reviews/openreview/5i7kqzase3/notes/vzua9dziyq.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "vzua9dziyq",
+ "replyTo": "xd2PcTVX3H",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer WuCQ",
+ "content": {
+ "comment": "Thank you for the authors' clear responses and efforts. My concerns have largely been addressed. That said, as the authors acknowledge, the memory overhead remains a limitation. Overall, I will keep my score of 4, which I would emphasize is on the accept side."
+ },
+ "createdAt": "2026-08-04T10:43:14.095Z",
+ "modifiedAt": "2026-11-19T17:17:11.902Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=vzua9dziyq",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/5i7kqzase3/notes/zihdqjqol9.json added

+++ b/reviews/openreview/5i7kqzase3/notes/zihdqjqol9.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "zihdqJQoL9",
+ "replyTo": "4PnsR8XZCn",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Area Chair,\n\nThank you very much for the time you have devoted to our submission despite your busy reviewing schedule. As the discussion period is coming to an end, we would like to briefly summarize the main clarifications and additional evidence provided during the rebuttal. In your meta-review, you highlighted the novelty of the work and whether its contributions and improvements are sufficiently meaningful. We therefore focused our rebuttal on clarifying these points from both theoretical and practical perspectives. \n\n* For **Reviewer WuCQ**, we added analyses of GPU memory, the sampling–accuracy–equivariance trade-off, equivariance behavior with increasing depth, and an additional LJ13 experiment demonstrating applicability beyond molecular benchmarks.\n* For **Reviewer RgUU**, we clarified sampling uniformity, the theoretical status of Claim 3.2, and the distinction from Cartesian-tensor approaches. The reviewer subsequently acknowledged these clarifications and raised the score to 5. \n* For **Reviewer ymhd**, we focused particularly on the novelty and contribution of EST relative to SCN/eSCN, adding controlled ablations, expressiveness analysis, force-level equivariance evaluation, physical-validity tests, and sampling-resolution ablations. The reviewer stated that these additions had substantially addressed the main concerns, expressed willingness to raise the score from borderline reject to borderline accept, and noted no remaining major concerns. \n\nWe believe these additions have helped clarify the novelty, practical contribution, and limitations of the method more precisely. Thank you again for your time and for the constructive guidance from you and the reviewers throughout the discussion.\n\n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-04T06:13:04.938Z",
+ "modifiedAt": "2026-11-19T17:17:11.899Z",
+ "url": "https://openreview.net/forum?id=5i7KqZASE3&noteId=zihdqJQoL9",
+ "license": "CC-BY-4.0"
+}